{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T16:59:38Z","timestamp":1777654778260,"version":"3.51.4"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T00:00:00Z","timestamp":1657670400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T00:00:00Z","timestamp":1657670400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100005632","name":"Narodowe Centrum Bada\u0144 i Rozwoju","doi-asserted-by":"publisher","award":["STRATEGMED1\/233624\/4\/NCBR\/2014"],"award-info":[{"award-number":["STRATEGMED1\/233624\/4\/NCBR\/2014"]}],"id":[{"id":"10.13039\/501100005632","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>The \u201cimage to patient\u201d registration procedure is crucial for the accuracy of surgical instrument tracking relative to the medical image while computer-aided surgery. The main aim of this work was to create an equal-resolution surface registration algorithm (ERSR) and analyze its efficiency.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The ERSR algorithm provides two datasets with equal, high resolution and approximately corresponding points. The registered sets are obtained by projection of a user-designed rectangle(s)-shaped uniform clouds of points on DICOM and surface scanner datasets. The tests of the algorithm were performed on a phantom with titanium microscrews. We analyzed the influence of DICOM resolution on the effect of the ERSR algorithm and compared the ERSR to standard paired-points landmark transform registration. The methods of analysis were Target Registration Error, distance maps, and their histogram evaluation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The mean TRE in case of ERSR equaled 0.8\u2009\u00b1\u20090.3\u00a0mm (resolution A), 0.8\u2009\u00b1\u20090.5\u00a0mm (resolution B), and 1.0\u2009\u00b1\u20090.7\u00a0mm (resolution C). The mean values were at least 0.4\u00a0mm lower than in the case of landmark transform registration. The distance maps between the model achieved from the scanner and the CT-based model were analyzed by histogram. The frequency of the first bin in a histogram of the distance map for ERSR was about 0.6 for all three resolutions of DICOM dataset and three times higher than in the case of landmark transform registration. The results were statistically analyzed using the Wilcoxon signed-rank test (alpha\u2009=\u20090.05).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The tests proved a statistically significant higher efficiency of equal resolution surface registration related to the landmark transform algorithm. It was proven that the lower resolution of the CT DICOM dataset did not degrade the efficiency of the ERSR algorithm. We observed a significantly lower response to decreased resolution than in the case of paired-points landmark transform registration.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-022-02704-1","type":"journal-article","created":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T16:16:24Z","timestamp":1657728984000},"page":"319-328","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["\u201cImage to patient\u201d equal-resolution surface registration supported by a surface scanner: analysis of algorithm efficiency for computer-aided surgery"],"prefix":"10.1007","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0368-8587","authenticated-orcid":false,"given":"Ewelina","family":"\u015awi\u0105tek-Najwer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2831-3538","authenticated-orcid":false,"given":"Marcin","family":"Majak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Micha\u0142","family":"Popek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3849-570X","authenticated-orcid":false,"given":"Magdalena","family":"\u017buk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,13]]},"reference":[{"issue":"7","key":"2704_CR1","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.1016\/j.jcms.2015.06.012","volume":"43","author":"P Pietruski","year":"2015","unstructured":"Pietruski P, Majak M, \u015awi\u0105tek-Najwer E, Popek M, Jaworowski J, \u017buk M, Nowakowski F (2015) Image-guided bone resection as a prospective alternative to cutting templates\u2014a preliminary study. J Craniomaxillofac Surg 43(7):1021\u20131027","journal-title":"J Craniomaxillofac Surg"},{"key":"2704_CR2","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1016\/j.tripleo.2009.02.011","volume":"107","author":"G Widmann","year":"2009","unstructured":"Widmann G, Stoffner R, Bale R (2009) Errors and error management in image-guided craniomaxillofacial surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 107:701\u2013715","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"2704_CR3","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1146\/annurev-bioeng-070909-105249","volume":"12","author":"K Cleary","year":"2010","unstructured":"Cleary K, Peters TM (2010) Image-guided interventions: technology review and clinical applications. Annu Rev Biomed Eng 12:119\u2013142","journal-title":"Annu Rev Biomed Eng"},{"key":"2704_CR4","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1002\/rcs.1509","volume":"10","author":"AI Omara","year":"2014","unstructured":"Omara AI, Wang MN, Fan YF, Song ZJ (2014) Anatomical landmarks for point-matching registration in image-guided neurosurgery. Int J Med Robot Comput Assist Surg 10:55\u201364","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"4","key":"2704_CR5","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1016\/j.bjps.2019.01.026","volume":"72","author":"P Pietruski","year":"2019","unstructured":"Pietruski P, Majak M, \u015awi\u0105tek-Najwer E, \u017buk M, Popek M, Mazurek M, \u015awiecka M, Jaworowski J (2019) Navigation-guided fibula free flap for mandibular reconstruction: a proof of concept study. J Plast Reconstr Aesthet Surg 72(4):572\u2013580","journal-title":"J Plast Reconstr Aesthet Surg"},{"issue":"12","key":"2704_CR6","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.1016\/j.ijom.2006.09.015","volume":"35","author":"G Eggers","year":"2006","unstructured":"Eggers G, M\u00fchling J, Marmulla R (2006) Image-to-patient registration techniques in head surgery. Int J Oral Maxillofac Surg 35(12):1081\u20131095","journal-title":"Int J Oral Maxillofac Surg"},{"key":"2704_CR7","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1097\/SCS.0000000000003283","volume":"28","author":"Y Fan","year":"2017","unstructured":"Fan Y, Xu X, Wang M (2017) A surface-based spatial registration method based on sense three- dimensional scanner. J Craniofac SURG 28:157\u2013160","journal-title":"J Craniofac SURG"},{"issue":"7","key":"2704_CR8","doi-asserted-by":"publisher","first-page":"e0180975","DOI":"10.1371\/journal.pone.0180975","volume":"12","author":"TD Grauvogel","year":"2017","unstructured":"Grauvogel TD, Engelskirchen P, Semper-Hogg W, Grauvogel J, Laszig R (2017) Navigation accuracy after automatic- and hybrid-surface registration in sinus and skull base surgery. PLoS ONE 12(7):e0180975","journal-title":"PLoS ONE"},{"issue":"7","key":"2704_CR9","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1007\/s11548-022-02608-0","volume":"17","author":"M de Boutray","year":"2022","unstructured":"de Boutray M, Cavalcanti Santos J, Bourgeade A, Ohayon M, Chammas P-E, Garrel R, Poignet P, Zemiti N (2022) Fibular registration using surface matching in navigation-guided osteotomies: a proof of concept study on 3D-printed models. Int J Comput Assist Radiol Surg 17(7):1321\u20131331","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2704_CR10","doi-asserted-by":"publisher","first-page":"e1977","DOI":"10.1002\/rcs.1977","volume":"15","author":"G Diakov","year":"2019","unstructured":"Diakov G, Freysinger W (2019) Vector field analysis for surface registration in computer-assisted ENT surgery. Int J Med Robot Comput Assist Surg 15:e1977","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"2704_CR11","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2020.2986470","author":"P Li","year":"2020","unstructured":"Li P, Wang R, Wang Y, Tao W (2020) Evaluation of the ICP algorithm in 3D point cloud registration. IEEE Access. https:\/\/doi.org\/10.1109\/ACCESS.2020.2986470","journal-title":"IEEE Access"},{"key":"2704_CR12","doi-asserted-by":"crossref","unstructured":"\u015awi\u0105tek-Najwer E, \u017buk M, Majak M, Popek M (2018) The rigid registration of CT and scanner dataset for computer aided surgery In: Tavares J, Natal Jorge R. (eds) VipIMAGE 2017 ECCOMAS 2017 Lecture Notes in Computational Vision and Biomechanics, 2018, vol 27 Springer, Cham","DOI":"10.1007\/978-3-319-68195-5_38"},{"issue":"4","key":"2704_CR13","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1016\/j.measurement.2011.12.020","volume":"45","author":"E \u015awi\u0105tek-Najwer","year":"2012","unstructured":"\u015awi\u0105tek-Najwer E, Krysztoforski K, Dragan S\u0141, B\u0119dzi\u0144ski R (2012) The investigation of the lower limb geometry using 3D sonography and magnetic resonance. Measurement 45(4):702\u2013710","journal-title":"Measurement"},{"key":"2704_CR14","doi-asserted-by":"publisher","first-page":"2667","DOI":"10.1007\/s12206-020-0540-6","volume":"34","author":"H Yoo","year":"2020","unstructured":"Yoo H, Choi A, Mun JH (2020) Acquisition of point cloud in CT image space to improve accuracy of surface registration: application to neurosurgical navigation system. J Mech Sci Technol 34:2667\u20132677","journal-title":"J Mech Sci Technol"},{"issue":"8","key":"2704_CR15","doi-asserted-by":"publisher","first-page":"1303","DOI":"10.1007\/s11548-019-01990-6","volume":"14","author":"Y Dong","year":"2019","unstructured":"Dong Y, Zhang C, Ji D, Wang M, Song Z (2019) Regional-surface-based registration for image-guided neurosurgery: effects of scan modes on registration accuracy. Int J Computer Assisted Radiol Surg 14(8):1303\u20131315","journal-title":"Int J Computer Assisted Radiol Surg"},{"key":"2704_CR16","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.jcms.2007.09.002","volume":"36","author":"H-T L\u00fcbbers","year":"2008","unstructured":"L\u00fcbbers H-T, Messmer P, Obwegeser J, Zwahlen R, Kikinis R, Gr\u00e4tz K, Matthews F (2008) Comparison of different registration methods for surgical navigation in cranio-maxillofacial surgery. J Cranio-Maxillo-Facial Surg Off Publ Eur Assoc Cranio-Maxillo-Facial Surg 36:109\u2013116","journal-title":"J Cranio-Maxillo-Facial Surg Off Publ Eur Assoc Cranio-Maxillo-Facial Surg"},{"issue":"1","key":"2704_CR17","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.jcms.2004.10.001","volume":"33","author":"J Hoffmann","year":"2005","unstructured":"Hoffmann J, Westendorff C, Leitner C, Bartz D, Reinert S (2005) Validation of 3D-laser surface registration for image-guided cranio-maxillofacial surgery. J Cranio-Maxillo-Facial Surg Offic Publ Eur Assoc Cranio-Maxillo-Facial Surg 33(1):13\u201318","journal-title":"J Cranio-Maxillo-Facial Surg Offic Publ Eur Assoc Cranio-Maxillo-Facial Surg"},{"issue":"3","key":"2704_CR18","doi-asserted-by":"publisher","first-page":"602e","DOI":"10.1097\/PRS.0000000000005381","volume":"143","author":"J Lee","year":"2018","unstructured":"Lee J, Mekuria K, Son T, Jeong WS, Choi JW, Kim Y (2018) A novel non- invasive patient-specific navigation method for orbital reconstructive surgery: a phantom study using patient data. Plastic Reconstruct Surg 2019 143(3):602e\u2013612e","journal-title":"Plastic Reconstruct Surg 2019"},{"issue":"7","key":"2704_CR19","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1016\/j.joms.2004.01.014","volume":"62","author":"R Marmulla","year":"2004","unstructured":"Marmulla R, L\u00fcth T, M\u00fchling J, Hassfeld S (2004) Markerless laser registration in image-guided oral and maxillofacial surgery. J Oral Maxillofac Surg 62(7):845\u2013851","journal-title":"J Oral Maxillofac Surg"},{"key":"2704_CR20","doi-asserted-by":"publisher","first-page":"101910","DOI":"10.1118\/1.4895847","volume":"41","author":"Y Fan","year":"2014","unstructured":"Fan Y, Jiang D, Wang M, Song Z (2014) A new markerless patient-to-image registration method using a portable 3D scanner. Med Phys 41:101910","journal-title":"Med Phys"},{"key":"2704_CR21","doi-asserted-by":"publisher","first-page":"5464","DOI":"10.3390\/app11125464","volume":"11","author":"A Choi","year":"2021","unstructured":"Choi A, Chae S, Kim T-H, Jung H, Lee S-S, Lee K-Y, Mun J-H (2021) A novel patient- to-image surface registration technique for ENT- and neuro-navigation systems: proper point set in patient space. Appl Sci 11:5464","journal-title":"Appl Sci"},{"issue":"6","key":"2704_CR22","doi-asserted-by":"publisher","first-page":"854","DOI":"10.1016\/j.jcms.2019.03.004","volume":"47","author":"P Pietruski","year":"2019","unstructured":"Pietruski P, Majak M, \u015awi\u0105tek-Najwer E, \u017buk M, Popek M, Mazurek M, \u015awiecka M, Jaworowski J (2019) Supporting mandibular resection with intraoperative navigation utilizing augmented reality technology - a proof of concept study. J Craniomaxillofac Surg 47(6):854\u2013859","journal-title":"J Craniomaxillofac Surg"},{"issue":"2","key":"2704_CR23","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.1002\/lary.28090","volume":"130","author":"P Pietruski","year":"2020","unstructured":"Pietruski P, Majak M, \u015awi\u0105tek-Najwer E, \u017buk M, Popek M, Jaworowski J, Mazurek M (2020) Supporting fibula free flap harvest with augmented reality: a proof-of-concept study. Laryngoscope 130(2):1173\u20131179","journal-title":"Laryngoscope"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02704-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-022-02704-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02704-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,31]],"date-time":"2023-01-31T14:31:42Z","timestamp":1675175502000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-022-02704-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,13]]},"references-count":23,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2023,2]]}},"alternative-id":["2704"],"URL":"https:\/\/doi.org\/10.1007\/s11548-022-02704-1","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,13]]},"assertion":[{"value":"21 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}