{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T18:46:57Z","timestamp":1769021217652,"version":"3.49.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,9,23]],"date-time":"2022-09-23T00:00:00Z","timestamp":1663891200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,9,23]],"date-time":"2022-09-23T00:00:00Z","timestamp":1663891200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["JP20H04553"],"award-info":[{"award-number":["JP20H04553"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"DOI":"10.1007\/s11548-022-02746-5","type":"journal-article","created":{"date-parts":[[2022,9,23]],"date-time":"2022-09-23T08:03:30Z","timestamp":1663920210000},"page":"17-27","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["A pilot study on an electromagnetic tracking system using tunneling magnetoresistance (TMR) sensors applicable to a 4F catheter (1.4\u00a0mm in diameter)"],"prefix":"10.1007","volume":"18","author":[{"given":"Rina","family":"Nagano","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuaki","family":"Hara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Etsuko","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Ohya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4919-9466","authenticated-orcid":false,"given":"Ichiro","family":"Sakuma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,9,23]]},"reference":[{"key":"2746_CR1","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1016\/S1368-8375(98)00018-9","volume":"34","author":"I Tohnai","year":"1998","unstructured":"Tohnai I, Fuwa N, Hayashi Y, Kaneko R, Tomaru Y, Hibino Y, Ueda M (1998) New superselective intra-arterial infusion via superficial temporal artery for cancer of the tongue and tumour tissue platinum concentration after carboplatin (CBDCA) infusion. Oral Oncol 34:387\u2013390. https:\/\/doi.org\/10.1016\/S1368-8375(98)00018-9","journal-title":"Oral Oncol"},{"issue":"12","key":"2746_CR2","doi-asserted-by":"publisher","first-page":"860","DOI":"10.1016\/j.oraloncology.2010.10.001","volume":"46","author":"W Kobayashi","year":"2010","unstructured":"Kobayashi W, Teh BG, Sakaki H, Sato H, Kimura H, Kakehata S, Nagahata M (2010) Superselective intra-arterial chemoradiotherapy with docetaxel\u2013nedaplatin for advanced oral cancer. Oral Oncol 46(12):860\u2013863. https:\/\/doi.org\/10.1016\/j.oraloncology.2010.10.001","journal-title":"Oral Oncol"},{"issue":"6","key":"2746_CR3","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1016\/j.tripleo.2007.07.031","volume":"105","author":"N Fuwa","year":"2008","unstructured":"Fuwa N, Kodaira T, Furutani K, Tachibana H, Nakamura T (2008) A new method of selective intra-arterial infusion therapy via the superficial temporal artery for head and neck cancer. Oral Surg, Oral Med, Oral Pathol, Oral Radiol Endodontol 105(6):783\u2013789. https:\/\/doi.org\/10.1016\/j.tripleo.2007.07.031","journal-title":"Oral Surg, Oral Med, Oral Pathol, Oral Radiol Endodontol"},{"issue":"8","key":"2746_CR4","doi-asserted-by":"publisher","first-page":"1702","DOI":"10.1109\/TMI.2014.2321777","volume":"33","author":"AM Franz","year":"2014","unstructured":"Franz AM, Haidegger T, Birkfellner W, Cleary K, Peters TM, Maier-Hein L (2014) Electromagnetic tracking in medicine\u2014a review of technology, validation, and applications. IEEE Trans Med Imag 33(8):1702\u20131725. https:\/\/doi.org\/10.1109\/TMI.2014.2321777","journal-title":"IEEE Trans Med Imag"},{"issue":"6","key":"2746_CR5","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1136\/heart.87.6.575","volume":"87","author":"PA Friedman","year":"2002","unstructured":"Friedman PA (2002) Novel mapping techniques for cardiac electrophysiology. Heart 87(6):575\u2013582. https:\/\/doi.org\/10.1136\/heart.87.6.575","journal-title":"Heart"},{"issue":"4","key":"2746_CR6","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1097\/01.RVI.0000148827.62296.B4","volume":"16","author":"B Wood","year":"2005","unstructured":"Wood B, Zhang H, Durrani A, Glossop N, Ranjan S, Lindisch D, Levy E, Banovac F, Borgert J, Krueger S (2005) Navigation with electromagnetic tracking for interventional radiology procedures: a feasibility study. J Vasc Interv Radiol 16(4):493\u2013505. https:\/\/doi.org\/10.1097\/01.RVI.0000148827.62296.B4","journal-title":"J Vasc Interv Radiol"},{"issue":"9","key":"2746_CR7","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1016\/j.jvir.2007.06.014","volume":"18","author":"J Kr\u00fccker","year":"2007","unstructured":"Kr\u00fccker J, Xu S, Glossop N, Viswanathan A, Borgert J, Schulz H, Wood BJ (2007) Electromagnetic tracking for thermal ablation and biopsy guidance: clinical evaluation of spatial accuracy. J Vasc Interv Radiol 18(9):1141\u20131150. https:\/\/doi.org\/10.1016\/j.jvir.2007.06.014","journal-title":"J Vasc Interv Radiol"},{"issue":"3","key":"2746_CR8","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1002\/rcs.1417","volume":"8","author":"S Condino","year":"2012","unstructured":"Condino S, Ferrari V, Freschi C, Alberti A, Berchiolli R, Mosca F, Ferrari M (2012) Electromagnetic navigation platform for endovascular surgery: how to develop sensorized catheters and guidewires. Int J Med Robot Comp Assist Surg 8(3):300\u2013310. https:\/\/doi.org\/10.1002\/rcs.1417","journal-title":"Int J Med Robot Comp Assist Surg"},{"key":"2746_CR9","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1002\/rcs.392","volume":"7","author":"J Wang","year":"2011","unstructured":"Wang J, Ohya T, Liao H, Sakuma I, Wang T, Tohnai I, Iwai T (2011) Intravascular catheter navigation using path planning and virtual visual feedback for oral cancer treatment. Int J Med Robot Comp Assist Surg 7:214\u2013224. https:\/\/doi.org\/10.1002\/rcs.392","journal-title":"Int J Med Robot Comp Assist Surg"},{"key":"2746_CR10","unstructured":"Aurora 5DOF Sensors (2022) https:\/\/www.ndigital.com\/electromagnetic-tracking-technology\/aurora\/aurora-sensors\/"},{"issue":"6","key":"2746_CR11","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1002\/hed.2890020604","volume":"2","author":"AL Stock","year":"1980","unstructured":"Stock AL, Collins HP, Davidson TM (1980) Anatomy of the superficial temporal artery. Head Neck Surg 2(6):466\u2013469. https:\/\/doi.org\/10.1002\/hed.2890020604","journal-title":"Head Neck Surg"},{"key":"2746_CR12","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1117\/12.2549764","volume":"11315","author":"R Piazza","year":"2020","unstructured":"Piazza R, Nisar H, Moore J, Condino S, Ferrari M, Ferrari V, Peters TM, Chen EC (2020) Towards electromagnetic tracking of J-tip guidewire: precision assessment of sensors during bending tests. Med Imag: Image-Guided Proced, Robot Intervent Model, SPIE 11315:37\u201346. https:\/\/doi.org\/10.1117\/12.2549764","journal-title":"Med Imag: Image-Guided Proced, Robot Intervent Model, SPIE"},{"key":"2746_CR13","unstructured":"3D Guidance 6DOF Sensors (2022) https:\/\/www.ndigital.com\/electromagnetic-tracking-technology\/3d-guidance\/3d-guidance-sensors\/"},{"issue":"6","key":"2746_CR14","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1007\/s11548-017-1568-7","volume":"12","author":"HA Jaeger","year":"2017","unstructured":"Jaeger HA, Franz AM, O\u2019Donoghue K, Seitel A, Trauzettel F, Maier-Hein L, Cantillon-Murphy P (2017) Anser EMT: the first open-source electromagnetic tracking platform for image-guided interventions. Int J Comput Assist Radiol Surg 12(6):1059\u20131067. https:\/\/doi.org\/10.1007\/s11548-017-1568-7","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"3","key":"2746_CR15","doi-asserted-by":"publisher","first-page":"1178","DOI":"10.1109\/JSEN.2017.2779560","volume":"18","author":"H Dai","year":"2017","unstructured":"Dai H, Song S, Zeng X, Su S, Lin M, Meng MQ-H (2017) 6-D electromagnetic tracking approach using uniaxial transmitting coil and tri-axial magneto-resistive sensor. IEEE Sens J 18(3):1178\u20131186. https:\/\/doi.org\/10.1109\/JSEN.2017.2779560","journal-title":"IEEE Sens J"},{"issue":"11","key":"2746_CR16","doi-asserted-by":"publisher","first-page":"12531","DOI":"10.1109\/JSEN.2020.3045660","volume":"21","author":"N Hadjigeorgiou","year":"2020","unstructured":"Hadjigeorgiou N, Asimakopoulos K, Papafotis K, Sotiriadis PP (2020) Vector: Magnetic field sensors: operating principles, calibration, and applications. IEEE Sens J 21(11):12531\u201312544. https:\/\/doi.org\/10.1109\/JSEN.2020.3045660","journal-title":"IEEE Sens J"},{"issue":"3","key":"2746_CR17","doi-asserted-by":"publisher","first-page":"L231","DOI":"10.1016\/0304-8853(95)90001-2","volume":"139","author":"T Miyazaki","year":"1995","unstructured":"Miyazaki T, Tezuka N (1995) Giant magnetic tunneling effect in Fe\/Al2O3\/Fe junction. J Magn Magn Mater 139(3):L231\u2013L234. https:\/\/doi.org\/10.1016\/0304-8853(95)90001-2","journal-title":"J Magn Magn Mater"},{"issue":"7Part1","key":"2746_CR18","doi-asserted-by":"publisher","first-page":"2371","DOI":"10.1118\/1.1944327","volume":"32","author":"JB Hummel","year":"2005","unstructured":"Hummel JB, Bax MR, Figl ML, Kang Y, Maurer C Jr, Birkfellner WW, Bergmann H, Shahidi R (2005) Design and application of an assessment protocol for electromagnetic tracking systems. Med Phys 32(7Part1):2371\u20132379. https:\/\/doi.org\/10.1118\/1.1944327","journal-title":"Med Phys"},{"issue":"9","key":"2746_CR19","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","volume":"30","author":"A Fedorov","year":"2012","unstructured":"Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin J-C, Pujol S, Bauer C, Jennings D, Fennessy F, Sonka M (2012) 3D Slicer as an image computing platform for the quantitative imaging network. Magn Reson Imag 30(9):1323\u20131341. https:\/\/doi.org\/10.1016\/j.mri.2012.05.001","journal-title":"Magn Reson Imag"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02746-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-022-02746-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02746-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,27]],"date-time":"2023-01-27T19:53:35Z","timestamp":1674849215000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-022-02746-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,23]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["2746"],"URL":"https:\/\/doi.org\/10.1007\/s11548-022-02746-5","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,23]]},"assertion":[{"value":"31 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 October 2022","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The \u2018#\u2019 symbol at the end of the equation 3 has been removed","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no other conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal rights"}},{"value":"This article does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}