{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T15:02:40Z","timestamp":1773414160808,"version":"3.50.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2023,3,30]],"date-time":"2023-03-30T00:00:00Z","timestamp":1680134400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,3,30]],"date-time":"2023-03-30T00:00:00Z","timestamp":1680134400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","award":["CGS-D"],"award-info":[{"award-number":["CGS-D"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005247","name":"University of British Columbia","doi-asserted-by":"publisher","award":["C.A. Lazlo Chair"],"award-info":[{"award-number":["C.A. Lazlo Chair"]}],"id":[{"id":"10.13039\/501100005247","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"DOI":"10.1007\/s11548-023-02869-3","type":"journal-article","created":{"date-parts":[[2023,3,30]],"date-time":"2023-03-30T13:09:48Z","timestamp":1680181788000},"page":"1093-1099","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Robotically controlled three-dimensional micro-ultrasound for prostate biopsy guidance"],"prefix":"10.1007","volume":"18","author":[{"given":"Reid","family":"Vassallo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tajwar Abrar","family":"Aleef","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qi","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian","family":"Wodlinger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter C.","family":"Black","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Septimiu E.","family":"Salcudean","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,3,30]]},"reference":[{"issue":"3","key":"2869_CR1","doi-asserted-by":"publisher","first-page":"209","DOI":"10.3322\/caac.21660","volume":"71","author":"H Sung","year":"2021","unstructured":"Sung H, Ferlay J, Siegel RL, Laversanne M, Soerjomataram I, Jemal A, Bray F (2021) Global cancer statistics 2020: Globocan estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 71(3):209\u2013249","journal-title":"CA Cancer J Clin"},{"issue":"4","key":"2869_CR2","doi-asserted-by":"publisher","first-page":"235","DOI":"10.5489\/cuaj.11134","volume":"5","author":"JI Izawa","year":"2011","unstructured":"Izawa JI, Klotz L, Siemens DR, Kassouf W, So A, Jordan J, Chetner M, Iansavichene AE (2011) Prostate cancer screening: Canadian guidelines 2011. Can Urol Assoc J 5(4):235","journal-title":"Can Urol Assoc J"},{"issue":"2","key":"2869_CR3","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1097\/01.ju.0000131621.61732.6b","volume":"172","author":"R Onur","year":"2004","unstructured":"Onur R, Littrup PJ, Pontes JE, Bianco FJ Jr (2004) Contemporary impact of transrectal ultrasound lesions for prostate cancer detection. J Urol 172(2):512\u2013514","journal-title":"J Urol"},{"issue":"5\u20136","key":"2869_CR4","doi-asserted-by":"publisher","first-page":"e293","DOI":"10.5489\/cuaj.1248","volume":"7","author":"EC Serefoglu","year":"2013","unstructured":"Serefoglu EC, Altinova S, Ugras NS, Akincioglu E, Asil E, Balbay D (2013) How reliable is 12-core prostate biopsy procedure in the detection of prostate cancer? Can Urol Assoc J 7(5\u20136):e293-8","journal-title":"Can Urol Assoc J"},{"issue":"4","key":"2869_CR5","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1016\/j.eururo.2018.11.040","volume":"75","author":"O Wegelin","year":"2019","unstructured":"Wegelin O, Exterkate L, van der Leest M, Kummer JA, Vreuls W, de Bruin PC, Bosch JR, Barentsz JO, Somford DM, van Melick HH (2019) The future trial: a multicenter randomised controlled trial on target biopsy techniques based on magnetic resonance imaging in the diagnosis of prostate cancer in patients with prior negative biopsies. Eur Urol 75(4):582\u2013590","journal-title":"Eur Urol"},{"key":"2869_CR6","doi-asserted-by":"crossref","unstructured":"Ameri G, Barker K, Sham D, Fenster A (2020) Mechanically-assisted 3D ultrasound scanner for urogynecological applications: preliminary results, vol 11319, pp 161\u2013166 SPIE","DOI":"10.1117\/12.2550574"},{"issue":"11","key":"2869_CR7","doi-asserted-by":"publisher","first-page":"112903","DOI":"10.1118\/1.4824326","volume":"40","author":"H Neshat","year":"2013","unstructured":"Neshat H, Cool DW, Barker K, Gardi L, Kakani N, Fenster A (2013) A 3D ultrasound scanning system for image guided liver interventions. Med Phys 40(11):112903","journal-title":"Med Phys"},{"issue":"12","key":"2869_CR8","doi-asserted-by":"publisher","first-page":"5397","DOI":"10.1118\/1.3002415","volume":"35","author":"J Bax","year":"2008","unstructured":"Bax J, Cool D, Gardi L, Knight K, Smith D, Montreuil J, Sherebrin S, Romagnoli C, Fenster A (2008) Mechanically assisted 3D ultrasound guided prostate biopsy system. Med Phys 35(12):5397\u20135410","journal-title":"Med Phys"},{"issue":"5","key":"2869_CR9","doi-asserted-by":"publisher","first-page":"929","DOI":"10.1007\/s11548-022-02604-4","volume":"17","author":"TA Aleef","year":"2022","unstructured":"Aleef TA, Zeng Q, Morris WJ, Mahdavi SS, Salcudean SE (2022) Registration of trans-perineal template mapping biopsy cores to volumetric ultrasound. Int J Comput Assist Radiol Surg 17(5):929\u2013936","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"2","key":"2869_CR10","doi-asserted-by":"publisher","first-page":"1055","DOI":"10.1118\/1.3531540","volume":"38","author":"J Bax","year":"2011","unstructured":"Bax J, Smith D, Bartha L, Montreuil J, Sherebrin S, Gardi L, Edirisinghe C, Fenster A (2011) A compact mechatronic system for 3D ultrasound guided prostate interventions. Med Phys 38(2):1055\u20131069","journal-title":"Med Phys"},{"key":"2869_CR11","doi-asserted-by":"publisher","first-page":"101588","DOI":"10.1016\/j.media.2019.101588","volume":"60","author":"G Samei","year":"2020","unstructured":"Samei G, Tsang K, Kesch C, Lobo J, Hor S, Mohareri O, Chang S, Goldenberg SL, Black PC, Salcudean S (2020) A partial augmented reality system with live ultrasound and registered preoperative MRI for guiding robot-assisted radical prostatectomy. Med Image Anal 60:101588","journal-title":"Med Image Anal"},{"issue":"4","key":"2869_CR12","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1002\/mp.12148","volume":"44","author":"WT Hrinivich","year":"2017","unstructured":"Hrinivich WT, Hoover DA, Surry K, Edirisinghe C, Montreuil J, D\u2019Souza D, Fenster A, Wong E (2017) Simultaneous automatic segmentation of multiple needles using 3D ultrasound for high-dose-rate prostate brachytherapy. Med Phys 44(4):1234\u20131245","journal-title":"Med Phys"},{"issue":"1131","key":"2869_CR13","doi-asserted-by":"publisher","first-page":"20210633","DOI":"10.1259\/bjr.20210633","volume":"95","author":"AB Dias","year":"2022","unstructured":"Dias AB, O\u2019Brien C, Correas J-M, Ghai S (2022) Multiparametric ultrasound and micro-ultrasound in prostate cancer: a comprehensive review. Br J Radiol 95(1131):20210633","journal-title":"Br J Radiol"},{"issue":"5","key":"2869_CR14","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1097\/JU.0000000000001639","volume":"205","author":"P Sountoulides","year":"2021","unstructured":"Sountoulides P, Pyrgidis N, Polyzos SA, Mykoniatis I, Asouhidou E, Papatsoris A, Dellis A, Anastasiadis A, Lusuardi L, Hatzichristou D (2021) Micro-ultrasound-guided vs. multiparametric magnetic resonance imaging-targeted biopsy in the detection of prostate cancer: a systematic review and meta-analysis. J Urol 205(5):1254\u20131262","journal-title":"J Urol"},{"issue":"3","key":"2869_CR15","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1089\/end.2021.0361","volume":"36","author":"C You","year":"2022","unstructured":"You C, Li X, Du Y, Peng L, Wang H, Zhang X, Wang A (2022) The microultrasound-guided prostate biopsy in detection of prostate cancer: A systematic review and meta-analysis. J Endourol 36(3):394\u2013402","journal-title":"J Endourol"},{"key":"2869_CR16","doi-asserted-by":"publisher","first-page":"106618","DOI":"10.1016\/j.cct.2021.106618","volume":"112","author":"L Klotz","year":"2022","unstructured":"Klotz L, Andriole G, Cash H, Cooperberg M, Crawford ED, Emberton M, Gomez-Sancha F, Klein E, Lughezzani G, Marks L, Montorsi F, Salomon G, Sanchez-Salas R, Shore N, Taneja S (2022) Optimization of prostate biopsy-micro-ultrasound versus MRI (optimum): A 3-arm randomized controlled trial evaluating the role of 29 mhz micro-ultrasound in guiding prostate biopsy in men with clinical suspicion of prostate cancer. Contemp Clin Trials 112:106618","journal-title":"Contemp Clin Trials"},{"issue":"2","key":"2869_CR17","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1109\/TMI.2020.3034065","volume":"40","author":"Q Zeng","year":"2020","unstructured":"Zeng Q, Honarvar M, Schneider C, Mohammad SK, Lobo J, Pang EH, Lau KT, Hu C, Jago J, Erb SR, Rohling R, Salcudean SE (2020) Three-dimensional multi-frequency shear wave absolute vibro-elastography (3D s-wave) with a matrix array transducer: implementation and preliminary in vivo study of the liver. IEEE Trans Med Imaging 40(2):648\u2013660","journal-title":"IEEE Trans Med Imaging"},{"key":"2869_CR18","first-page":"79","volume-title":"A robotic system for intra-operative trans-rectal ultrasound and ultrasound elastography in radical prostatectomy","author":"T Adebar","year":"2011","unstructured":"Adebar T, Salcudean S, Mahdavi S, Moradi M, Nguan C, Goldenberg L (2011) A robotic system for intra-operative trans-rectal ultrasound and ultrasound elastography in radical prostatectomy. Springer, pp 79\u201389"},{"issue":"10","key":"2869_CR19","doi-asserted-by":"publisher","first-page":"2527","DOI":"10.1109\/TBME.2014.2322864","volume":"61","author":"A Lasso","year":"2014","unstructured":"Lasso A, Heffter T, Rankin A, Pinter C, Ungi T, Fichtinger G (2014) Plus: open-source toolkit for ultrasound-guided intervention systems. IEEE Trans Biomed Eng 61(10):2527\u20132537","journal-title":"IEEE Trans Biomed Eng"},{"key":"2869_CR20","unstructured":"Dance D, Christofides S, Maidment A, McLean I, Ng K (2014) Diagnostic radiology physics. Int Atom Energy Agency 299"},{"key":"2869_CR21","first-page":"277","volume-title":"In3d slicer: a platform for subject-specific image analysis, visualization, and clinical support","author":"R Kikinis","year":"2014","unstructured":"Kikinis R, Pieper SD, Vosburgh KG (2014) In3d slicer: a platform for subject-specific image analysis, visualization, and clinical support. Springer, pp 277\u2013289"},{"issue":"3","key":"2869_CR22","doi-asserted-by":"publisher","first-page":"035026","DOI":"10.1088\/2057-1976\/ab12b6","volume":"5","author":"E Lugez","year":"2019","unstructured":"Lugez E, Sadjadi H, Joshi CP, Hashtrudi-Zaad K, Akl SG, Fichtinger G (2019) Field distortion compensation for electromagnetic tracking of ultrasound probes with application in high-dose-rate prostate brachytherapy. Biomed Phys Eng Exp 5(3):035026","journal-title":"Biomed Phys Eng Exp"},{"issue":"7","key":"2869_CR23","doi-asserted-by":"publisher","first-page":"1341","DOI":"10.1016\/j.ultrasmedbio.2018.02.014","volume":"44","author":"D Rohrbach","year":"2018","unstructured":"Rohrbach D, Wodlinger B, Wen J, Mamou J, Feleppa E (2018) High-frequency quantitative ultrasound for imaging prostate cancer using a novel micro-ultrasound scanner. Ultrasound Med Biol 44(7):1341\u20131354","journal-title":"Ultrasound Med Biol"},{"issue":"10","key":"2869_CR24","doi-asserted-by":"publisher","first-page":"3148","DOI":"10.1109\/TMI.2020.2988198","volume":"39","author":"Y Shao","year":"2020","unstructured":"Shao Y, Wang J, Wodlinger B, Salcudean SE (2020) Improving prostate cancer (PCA) classification performance by using three-player minimax game to reduce data source heterogeneity. IEEE Trans Med Imaging 39(10):3148\u20133158","journal-title":"IEEE Trans Med Imaging"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-023-02869-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-023-02869-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-023-02869-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,21]],"date-time":"2023-06-21T14:39:57Z","timestamp":1687358397000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-023-02869-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,30]]},"references-count":24,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2023,6]]}},"alternative-id":["2869"],"URL":"https:\/\/doi.org\/10.1007\/s11548-023-02869-3","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,30]]},"assertion":[{"value":"7 February 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 March 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors declare that they have no competing interests. Brian Wodlinger is employed by Exact Imaging.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}