{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T13:24:58Z","timestamp":1762953898507,"version":"3.37.3"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2023,4,14]],"date-time":"2023-04-14T00:00:00Z","timestamp":1681430400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,4,14]],"date-time":"2023-04-14T00:00:00Z","timestamp":1681430400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003542","name":"Ministerium f\u00fcr Wissenschaft, Forschung und Kunst Baden-W\u00fcrttemberg","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003542","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001661","name":"Ruprecht-Karls-Universit\u00e4t Heidelberg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100001661","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>A robotic assistive device is developed for needle-based percutaneous interventions. The aim is a hybrid system using both manual and actuated robotic operation in order to obtain a device that has a large workspace but can still fit in the gantry opening of a CT scanner. This will enable physicians to perform precise and time-efficient CT-guided percutaneous interventions. The concept of the mechanics and software of the device is presented in this work.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The approach is a semi-automated robotic assistive device, which combines manual and robotic positioning to reduce the number and size of necessary motors. The system consists of a manual rough positioning unit, a robotic fine positioning unit and an optical needle tracking unit. The resulting system has eight degrees of freedom, of which four are manual, which comprise encoders to monitor the position of each axis. The remaining four axes are actuated axes for fine positioning of the needle. Cameras are attached to the mechanical structure for 3D tracking of the needle pose. The software is based on open-source software, mainly ROS2 as robotic middleware, Moveit2 for trajectory calculation and 3D Slicer for needle path planning.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The communication between the components was successfully tested with a clinical CT scanner. In a first experiment, four needle insertions were planned and the deviation of the actual needle path from the planned path was measured. The mean deviation from the needle path to the target point was 21.9\u00a0mm, which is mainly caused both by translational deviation (15.4\u00a0mm) and angular deviation (6.8\u00b0) of the needle holder. The optical tracking system was able to detect the needle position with a mean deviation of 3.9\u00a0mm.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The first validation of the system was successful which proves that the proposed concept for both the hardware and software is feasible. In a next step, an automatic position correction based on the optical tracking system will be integrated, which is expected to significantly improve the system accuracy.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-023-02882-6","type":"journal-article","created":{"date-parts":[[2023,4,14]],"date-time":"2023-04-14T12:01:56Z","timestamp":1681473716000},"page":"1571-1575","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A semi-automated robotic system for percutaneous interventions"],"prefix":"10.1007","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2736-3683","authenticated-orcid":false,"given":"Marius","family":"Siegfarth","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6477-8941","authenticated-orcid":false,"given":"Raffael","family":"Lutz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6242-5122","authenticated-orcid":false,"given":"Nils-Christian","family":"Iseke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3939-5893","authenticated-orcid":false,"given":"Javier","family":"Moviglia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7052-844X","authenticated-orcid":false,"given":"Fabian","family":"Sadi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Stallkamp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,4,14]]},"reference":[{"issue":"4","key":"2882_CR1","doi-asserted-by":"publisher","first-page":"427","DOI":"10.15386\/cjmed-1145","volume":"91","author":"A Roman","year":"2018","unstructured":"Roman A, Achimas-Cadariu P, Fetica B, Gata V, Seicean A (2018) CT-guided procedures: an initial experience. Clujul Med 91(4):427\u2013434. https:\/\/doi.org\/10.15386\/cjmed-1145","journal-title":"Clujul Med"},{"issue":"4","key":"2882_CR2","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1080\/13645700701520578","volume":"16","author":"R Bale","year":"2007","unstructured":"Bale R, Widmann G (2007) Navigated CT-guided interventions. Minim Invasive Ther Allied Technol 16(4):196\u2013204. https:\/\/doi.org\/10.1080\/13645700701520578","journal-title":"Minim Invasive Ther Allied Technol"},{"issue":"sup1","key":"2882_CR3","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1080\/24699322.2018.1557907","volume":"24","author":"Z Han","year":"2019","unstructured":"Han Z, Yu K, Hu L, Li W, Yang H, Gan M, Guo N, Yang B, Liu H, Wang Y (2019) A targeting method for robot-assisted percutaneous needle placement under fluoroscopy guidance. Comput Assist Surg (Abingdon, England) 24(sup1):44\u201352. https:\/\/doi.org\/10.1080\/24699322.2018.1557907","journal-title":"Comput Assist Surg (Abingdon, England)"},{"issue":"2","key":"2882_CR4","doi-asserted-by":"publisher","first-page":"2182","DOI":"10.1002\/rcs.2182","volume":"17","author":"HC Kim","year":"2021","unstructured":"Kim HC, Jeon H, An SB, Kim H, Hwang S, Cha Y, Moon S, Shin DA, Ha Y, Kim KN, Yoon DH, Yi S (2021) Novel C-arm based planning spine surgery robot proved in a porcine model and quantitative accuracy assessment methodology. Int J Med Robot Comput Assist Surgery MRCAS 17(2):2182. https:\/\/doi.org\/10.1002\/rcs.2182","journal-title":"Int J Med Robot Comput Assist Surgery MRCAS"},{"issue":"1","key":"2882_CR5","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1007\/s00270-021-02938-7","volume":"45","author":"M Kostrzewa","year":"2022","unstructured":"Kostrzewa M, Rothfuss A, P\u00e4tz T, K\u00fchne M, Schoenberg SO, Diehl SJ, Stallkamp J, Rathmann N (2022) Robotic assistance system for cone-beam computed tomography-guided percutaneous needle placement. Cardiovasc Intervent Radiol 45(1):62\u201368. https:\/\/doi.org\/10.1007\/s00270-021-02938-7","journal-title":"Cardiovasc Intervent Radiol"},{"issue":"3","key":"2882_CR6","doi-asserted-by":"publisher","first-page":"233","DOI":"10.5152\/dir.2017.16422","volume":"23","author":"HJ Won","year":"2017","unstructured":"Won HJ, Kim N, Kim GB, Seo JB, Kim H (2017) Validation of a CT-guided intervention robot for biopsy and radiofrequency ablation: experimental study with an abdominal phantom. Diagn Interv Radiol (Ankara, Turkey) 23(3):233\u2013237. https:\/\/doi.org\/10.5152\/dir.2017.16422","journal-title":"Diagn Interv Radiol (Ankara, Turkey)"},{"issue":"3","key":"2882_CR7","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1109\/EMB.2007.910262","volume":"27","author":"I Bricault","year":"2008","unstructured":"Bricault I, Zemiti N, Jouniaux E, Fouard C, Taillant E, Dorandeu F, Cinquin P (2008) Light puncture robot for CT and MRI interventions: designing a new robotic architecture to perform abdominal and thoracic punctures. IEEE Eng Med Biol Mag 27(3):42\u201350. https:\/\/doi.org\/10.1109\/EMB.2007.910262","journal-title":"IEEE Eng Med Biol Mag"},{"key":"2882_CR8","doi-asserted-by":"publisher","unstructured":"Wang Z, Dong Y, Fang Y, Li M, Xu T, Lei Y (2022) A Light-weight High-accuracy 4-DOF Robot for CT-image guided percutaneous interventions. In: 2022 international symposium on medical robotics (ISMR). IEEE, pp\u00a01\u20136. https:\/\/doi.org\/10.1109\/ISMR48347.2022.9807576","DOI":"10.1109\/ISMR48347.2022.9807576"},{"key":"2882_CR9","doi-asserted-by":"publisher","unstructured":"Seitel A, Walsh CJ, Hanumara NC, Shepard J-A, Slocum AH, Meinzer H-P, Gupta R, Maier-Hein L (2009) Development and evaluation of a new image-based user interface for robot-assisted needle placements with the Robopsy system. In: Miga MI, Wong KH (eds) Medical imaging 2009: visualization, image-guided procedures, and modeling. SPIE, 72610X. https:\/\/doi.org\/10.1117\/12.811507","DOI":"10.1117\/12.811507"},{"issue":"3","key":"2882_CR10","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1109\/EMB.2007.910274","volume":"27","author":"A Melzer","year":"2008","unstructured":"Melzer A, Gutmann B, Remmele T, Wolf R, Lukoscheck A, Bock M, Bardenheuer H, Fischer H (2008) Innomotion for percutaneous image-guided interventions: principles and evaluation of this MR- and CT-compatible robotic system. IEEE Eng Med Biol Mag 27(3):66\u201373. https:\/\/doi.org\/10.1109\/EMB.2007.910274","journal-title":"IEEE Eng Med Biol Mag"},{"issue":"4","key":"2882_CR11","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.1109\/TBME.2014.2367233","volume":"62","author":"G Li","year":"2015","unstructured":"Li G, Su H, Cole GA, Shang W, Harrington K, Camilo A, Pilitsis JG, Fischer GS (2015) Robotic system for MRI-guided stereotactic neurosurgery. IEEE Trans Biomed Eng 62(4):1077\u20131088. https:\/\/doi.org\/10.1109\/TBME.2014.2367233","journal-title":"IEEE Trans Biomed Eng"},{"key":"2882_CR12","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1145\/3126594.3126664","volume-title":"Proceedings of the 30th annual ACM symposium on user interface software and technology","author":"P-C Wu","year":"2017","unstructured":"Wu P-C, Wang R, Kin K, Twigg C, Han S, Yang M-H, Chien S-Y (2017) DodecaPen: accurate 6dof tracking of a passive stylus. In: Gajos K, Mankoff J, Harrison C (eds) Proceedings of the 30th annual ACM symposium on user interface software and technology. ACM Press, New York, pp 365\u2013374. https:\/\/doi.org\/10.1145\/3126594.3126664"},{"key":"2882_CR13","doi-asserted-by":"publisher","DOI":"10.1126\/scirobotics.abm6074","author":"S Macenski","year":"2022","unstructured":"Macenski S, Foote T, Gerkey B, Lalancette C, Woodall W (2022) Robot operating system 2: design, architecture, and uses in the wild. Sci Robot. https:\/\/doi.org\/10.1126\/scirobotics.abm6074","journal-title":"Sci Robot"},{"key":"2882_CR14","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/978-1-4614-7657-3_19","volume-title":"Intraoperative imaging and image-guided therapy","author":"R Kikinis","year":"2014","unstructured":"Kikinis R, Pieper SD, Vosburgh KG (2014) 3D Slicer: a platform for subject-specific image analysis, visualization, and clinical support. In: Jolesz FA (ed) Intraoperative imaging and image-guided therapy. Springer, New York, pp 277\u2013289. https:\/\/doi.org\/10.1007\/978-1-4614-7657-3_19"},{"issue":"7","key":"2882_CR15","doi-asserted-by":"publisher","first-page":"4445","DOI":"10.1002\/mp.15701","volume":"49","author":"DF Bauer","year":"2022","unstructured":"Bauer DF, Rosenkranz J, Golla A-K, T\u00f6nnes C, Hermann I, Russ T, Kabelitz G, Rothfuss AJ, Schad LR, Stallkamp JL, Z\u00f6llner FG (2022) Development of an abdominal phantom for the validation of an oligometastatic disease diagnosis workflow. Med Phys 49(7):4445\u20134454. https:\/\/doi.org\/10.1002\/mp.15701","journal-title":"Med Phys"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-023-02882-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-023-02882-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-023-02882-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,8]],"date-time":"2023-09-08T11:13:54Z","timestamp":1694171634000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-023-02882-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,14]]},"references-count":15,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2023,9]]}},"alternative-id":["2882"],"URL":"https:\/\/doi.org\/10.1007\/s11548-023-02882-6","relation":{},"ISSN":["1861-6429"],"issn-type":[{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2023,4,14]]},"assertion":[{"value":"23 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 March 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 April 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no competing interests to declare that are relevant to the content of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}