{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,29]],"date-time":"2026-03-29T00:59:42Z","timestamp":1774745982575,"version":"3.50.1"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2023,5,17]],"date-time":"2023-05-17T00:00:00Z","timestamp":1684281600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,5,17]],"date-time":"2023-05-17T00:00:00Z","timestamp":1684281600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100007316","name":"Klaus Tschira Stiftung","doi-asserted-by":"publisher","award":["00.021.2019"],"award-info":[{"award-number":["00.021.2019"]}],"id":[{"id":"10.13039\/501100007316","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Endovascular interventions require intense practice to develop sufficient dexterity in catheter handling within the human body. Therefore, we present a modular training platform, featuring 3D-printed vessel phantoms with patient-specific anatomy and integrated piezoresistive impact force sensing of instrument interaction at clinically relevant locations for feedback-based skill training to detect and reduce damage to the delicate vascular wall.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The platform was fabricated and then evaluated in a user study by medical (<jats:inline-formula><jats:alternatives><jats:tex-math>$$n=10$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>n<\/mml:mi>\n                      <mml:mo>=<\/mml:mo>\n                      <mml:mn>10<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula>) and non-medical (<jats:inline-formula><jats:alternatives><jats:tex-math>$$n=10$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>n<\/mml:mi>\n                      <mml:mo>=<\/mml:mo>\n                      <mml:mn>10<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula>) users. The users had to navigate a set of guidewire and catheter through a parkour of 3 modules including an aneurismatic abdominal aorta, while impact force and completion time were recorded. Eventually, a questionnaire was conducted.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The platform allowed to perform more than 100 runs in which it proved capable to distinguish between users of different experience levels. Medical experts in the fields of vascular and visceral surgery had a strong performance assessment on the platform. It could be shown, that medical students could improve runtime and impact over 5 runs. The platform was well received and rated as promising for medical education despite the experience of higher friction compared to real human vessels.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>We investigated an authentic patient-specific training platform with integrated sensor-based feedback functionality for individual skill training in endovascular surgery. The presented method for phantom manufacturing is easily applicable to arbitrary patient-individual imaging data. Further work shall address the implementation of smaller vessel branches, as well as real-time feedback and camera imaging for further improved training experience.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-023-02935-w","type":"journal-article","created":{"date-parts":[[2023,5,17]],"date-time":"2023-05-17T02:01:32Z","timestamp":1684288892000},"page":"1687-1695","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["A sensorized modular training platform to reduce vascular damage in endovascular surgery"],"prefix":"10.1007","volume":"18","author":[{"given":"Nikola","family":"Fischer","sequence":"first","affiliation":[]},{"given":"Christian","family":"Marzi","sequence":"additional","affiliation":[]},{"given":"Katrin","family":"Meisenbacher","sequence":"additional","affiliation":[]},{"given":"Anna","family":"Kisilenko","sequence":"additional","affiliation":[]},{"given":"Tornike","family":"Davitashvili","sequence":"additional","affiliation":[]},{"given":"Martin","family":"Wagner","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5239-5305","authenticated-orcid":false,"given":"Franziska","family":"Mathis-Ullrich","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2023,5,17]]},"reference":[{"issue":"3","key":"2935_CR1","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1016\/j.ejvs.2015.10.011","volume":"51","author":"KWM See","year":"2016","unstructured":"See KWM, Chui KH, Chan WH, Wong KC, Chan YC (2016) Evidence for endovascular simulation training: a systematic review. Eur J Vasc Endovasc Surg 51(3):441\u2013451. https:\/\/doi.org\/10.1016\/j.ejvs.2015.10.011","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"6","key":"2935_CR2","doi-asserted-by":"publisher","first-page":"1158","DOI":"10.1016\/j.jsurg.2015.05.010","volume":"72","author":"DE Kendrick","year":"2015","unstructured":"Kendrick DE, Gosling AF, Nagavalli A, Kashyap VS, Wang JC (2015) Endovascular simulation leads to efficiency and competence in thoracic endovascular aortic repair procedures. J Surg Educ 72(6):1158\u20131164. https:\/\/doi.org\/10.1016\/j.jsurg.2015.05.010","journal-title":"J Surg Educ"},{"issue":"03","key":"2935_CR3","doi-asserted-by":"publisher","first-page":"1640010","DOI":"10.1142\/s2424905x16400109","volume":"01","author":"EB Mazomenos","year":"2016","unstructured":"Mazomenos EB, Chang P-L, Rolls A, Hawkes DJ, Bicknell CD, Poorten EV, Riga CV, Desjardins A, Stoyanov D (2016) A survey on the current status and future challenges towards objective skills assessment in endovascular surgery. J Med Robot Res 01(03):1640010. https:\/\/doi.org\/10.1142\/s2424905x16400109","journal-title":"J Med Robot Res"},{"issue":"3","key":"2935_CR4","doi-asserted-by":"publisher","first-page":"521","DOI":"10.4103\/0971-9784.185548","volume":"19","author":"S Aggarwal","year":"2016","unstructured":"Aggarwal S, Choudhury E, Ladha S, Kapoor P, Kiran U (2016) Simulation in cardiac catheterization laboratory: need of the hour to improve the clinical skills. Ann Card Anaesth 19(3):521\u2013526. https:\/\/doi.org\/10.4103\/0971-9784.185548","journal-title":"Ann Card Anaesth"},{"issue":"1","key":"2935_CR5","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.jvir.2009.09.019","volume":"21","author":"K Ahmed","year":"2010","unstructured":"Ahmed K, Keeling AN, Fakhry M, Ashrafian H, Aggarwal R, Naughton PA, Darzi A, Cheshire N, Athanasiou T, Hamady M (2010) Role of virtual reality simulation in teaching and assessing technical skills in endovascular intervention. J Vasc Interv Radiol 21(1):55\u201366. https:\/\/doi.org\/10.1016\/j.jvir.2009.09.019","journal-title":"J Vasc Interv Radiol"},{"issue":"4","key":"2935_CR6","doi-asserted-by":"publisher","first-page":"1154","DOI":"10.1016\/j.jvs.2013.11.074","volume":"59","author":"BA Eslahpazir","year":"2014","unstructured":"Eslahpazir BA, Goldstone J, Allemang MT, Wang JC, Kashyap VS (2014) Principal considerations for the contemporary high-fidelity endovascular simulator design used in training and evaluation. J Vasc Surg 59(4):1154\u20131162. https:\/\/doi.org\/10.1016\/j.jvs.2013.11.074","journal-title":"J Vasc Surg"},{"issue":"3","key":"2935_CR7","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1515\/iss-2018-0020","volume":"3","author":"I Torres","year":"2020","unstructured":"Torres I, De Luccia N (2020) Artificial vascular models for endovascular training (3D printing). Innov Surg Sci 3(3):225\u2013234. https:\/\/doi.org\/10.1515\/iss-2018-0020","journal-title":"Innov Surg Sci"},{"key":"2935_CR8","doi-asserted-by":"publisher","DOI":"10.3390\/jfb13040301","author":"DY Kim","year":"2022","unstructured":"Kim DY, Tan X, Jeong M, Li D, Miernik A, Qiu T (2022) A high-fidelity artificial urological system for the quantitative assessment of endoscopic skills. J Funct Biomater. https:\/\/doi.org\/10.3390\/jfb13040301","journal-title":"J Funct Biomater"},{"key":"2935_CR9","doi-asserted-by":"publisher","unstructured":"Kaschwich M, Dell A, Matysiak F, Bouchagiar J, Bayer A, Scharfschwerdt M, Ernst F, Kleemann M, Horn M (2020) Development of an ultrasound-capable phantom with patient-specific 3D-printed vascular anatomy to simulate peripheral endovascular interventions. Ann Anat 232:151563. https:\/\/doi.org\/10.1016\/j.aanat.2020.151563","DOI":"10.1016\/j.aanat.2020.151563"},{"key":"2935_CR10","doi-asserted-by":"crossref","unstructured":"Payne CJ, Rafii-Tari H, Yang GZ (2012) A force feedback system for endovascular catheterisation. In: IEEE international conference on intelligent robots and systems, pp 1298\u20131304. https:\/\/doi.org\/10.1109\/IROS.2012.6386149","DOI":"10.1109\/IROS.2012.6386149"},{"key":"2935_CR11","doi-asserted-by":"crossref","unstructured":"Chi W, Rafii-Tari H, Payne CJ, Liu J, Riga C, Bicknell C, Yang GZ (2017) A learning based training and skill assessment platform with haptic guidance for endovascular catheterization. In: Proceedings: IEEE international conference on robotics and automation, pp 2357\u20132363. https:\/\/doi.org\/10.1109\/ICRA.2017.7989273","DOI":"10.1109\/ICRA.2017.7989273"},{"key":"2935_CR12","doi-asserted-by":"crossref","unstructured":"Rafii-Tari H, Payne CJ, Liu J, Riga C, Bicknell C, Yang GZ (2015) Towards automated surgical skill evaluation of endovascular catheterization tasks based on force and motion signatures. In: Proceedings: IEEE international conference on robotics and automation, pp 1789\u20131794. https:\/\/doi.org\/10.1109\/ICRA.2015.7139430","DOI":"10.1109\/ICRA.2015.7139430"},{"issue":"4","key":"2935_CR13","doi-asserted-by":"publisher","first-page":"1022","DOI":"10.1016\/j.jvs.2010.07.008","volume":"52","author":"MF Fillinger","year":"2010","unstructured":"Fillinger MF, Greenberg RK, McKinsey JF, Chaikof EL (2010) Reporting standards for thoracic endovascular aortic repair (tevar). J Vasc Surg 52(4):1022\u20131033","journal-title":"J Vasc Surg"},{"issue":"1","key":"2935_CR14","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1515\/cdbme-2021-1019","volume":"7","author":"N Fischer","year":"2021","unstructured":"Fischer N, Scheikl P, Marzi C, Galindo-Blanco B, Kisilenko A, M\u00fcller-Stich BP, Wagner M, Mathis-Ullrich F (2021) Flexible facile tactile sensor for smart vessel phantoms. Curr Direct Biomed Eng 7(1):7\u201311. https:\/\/doi.org\/10.1515\/cdbme-2021-1019","journal-title":"Curr Direct Biomed Eng"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-023-02935-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-023-02935-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-023-02935-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,8]],"date-time":"2023-09-08T11:14:17Z","timestamp":1694171657000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-023-02935-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,17]]},"references-count":14,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2023,9]]}},"alternative-id":["2935"],"URL":"https:\/\/doi.org\/10.1007\/s11548-023-02935-w","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,17]]},"assertion":[{"value":"9 January 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 April 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors state no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies on human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The vessel phantom is based on segmentation of anonymized CTA-data of a patient with an aneurysm of the abdominal aorta. The patient provided written informed consent into anonymous use of the CTA-data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}