{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:24:46Z","timestamp":1740144286743,"version":"3.37.3"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2024,1,18]],"date-time":"2024-01-18T00:00:00Z","timestamp":1705536000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,1,18]],"date-time":"2024-01-18T00:00:00Z","timestamp":1705536000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Grant-in-Aid for Scientific Research","award":["JSPS KAKENHI Grant Number JP 20H04553"],"award-info":[{"award-number":["JSPS KAKENHI Grant Number JP 20H04553"]}]},{"DOI":"10.13039\/501100004721","name":"The University of Tokyo","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004721","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Considering vessel deformation, endovascular navigation requires intraoperative geometric information. Mechanical intravascular ultrasound (IVUS) with an electromagnetic (EM) sensor can be used to reconstruct blood vessels with thin diameter. However, the integration design should be evaluated based on the factors affecting the reconstruction error.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The interference between the mechanical IVUS and EM sensor was measured in different relative positions. Two designs of the integrated catheter were evaluated by measuring the reconstruction errors using a rigid vascular phantom.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>When the distance from the EM sensor to the field generator was 75\u00a0mm, the interference from mechanical IVUS to an EM sensor was negligible, with position and rotation errors less than 0.1\u00a0mm and 0.6\u00b0, respectively. The reconstructed vessel model for proximal IVUS transducer had a smooth surface but an inaccurate shape at large curvature of the vascular phantom. When the distance to the field generator was 175\u00a0mm, the error increased significantly.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Placing the IVUS transducer on the proximal side of the EM sensor is superior in terms of interference reduction but inferior in terms of mechanical stability compared to a distal transducer. The distal side is preferred due to better mechanical stability during catheter manipulation at larger curvature. With this configuration, surface reconstruction errors less than 1.7\u00a0mm (with RMS 0.57\u00a0mm) were achieved when the distance to the field generator was less than 175\u00a0mm.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-024-03059-5","type":"journal-article","created":{"date-parts":[[2024,1,18]],"date-time":"2024-01-18T18:01:41Z","timestamp":1705600901000},"page":"1545-1554","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Design consideration on integration of mechanical intravascular ultrasound and electromagnetic tracking sensor for intravascular reconstruction"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4676-4383","authenticated-orcid":false,"given":"Wenran","family":"Cai","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7291-6825","authenticated-orcid":false,"given":"Kazuaki","family":"Hara","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7631-0940","authenticated-orcid":false,"given":"Naoki","family":"Tomii","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1794-0173","authenticated-orcid":false,"given":"Etsuko","family":"Kobayashi","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0094-2722","authenticated-orcid":false,"given":"Takashi","family":"Ohya","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4919-9466","authenticated-orcid":false,"given":"Ichiro","family":"Sakuma","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2024,1,18]]},"reference":[{"issue":"3\u20134","key":"3059_CR1","first-page":"101","volume":"68","author":"I Tohnai","year":"2006","unstructured":"Tohnai I (2006) Chemotherapy using intra-arterial infusion for oral cancer. Nagoya J Med Sci 68(3\u20134):101\u2013108","journal-title":"Nagoya J Med Sci"},{"key":"3059_CR2","doi-asserted-by":"publisher","first-page":"3806","DOI":"10.1109\/IROS.2012.6386139","volume":"2012","author":"A Dore","year":"2012","unstructured":"Dore A, Smoljkic G, Poorten EV, Sette M, Sloten JV, Yang GZ (2012) Catheter navigation based on probabilistic fusion of electromagnetic tracking and physically-based simulation. IEEE\/RSJ Int Conf Intell Robots Syst 2012:3806\u20133811. https:\/\/doi.org\/10.1109\/IROS.2012.6386139","journal-title":"IEEE\/RSJ Int Conf Intell Robots Syst"},{"issue":"8","key":"3059_CR3","doi-asserted-by":"publisher","first-page":"1702","DOI":"10.1109\/TMI.2014.2321777","volume":"33","author":"AM Franz","year":"2014","unstructured":"Franz AM, Haidegger T, Birkfellner W, Cleary K, Peters TM, Maier-Hein L (2014) Electromagnetic tracking in medicine\u2013a review of technology, validation, and applications. IEEE Trans Med Imaging 33(8):1702\u20131725. https:\/\/doi.org\/10.1109\/TMI.2014.2321777","journal-title":"IEEE Trans Med Imaging"},{"issue":"3","key":"3059_CR4","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1007\/s11517-021-02326-w","volume":"59","author":"K Yanagida","year":"2021","unstructured":"Yanagida K, Ohya T, Wang J, Iwai T, Izumi T, Kobayashi E, Sakuma I, Mitsudo K (2021) Applicability of a single camera-based catheter navigation system using teeth arch as an anatomical landmark for superselective intraarterial infusion in advanced oral cancer treatment. Med Biol Eng Comput 59(3):663\u2013672. https:\/\/doi.org\/10.1007\/s11517-021-02326-w","journal-title":"Med Biol Eng Comput"},{"issue":"2","key":"3059_CR5","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.compmedimag.2013.01.007","volume":"37","author":"K Luan","year":"2013","unstructured":"Luan K, Ohya T, Liao H, Kobayashi E, Sakuma I (2013) Vessel bifurcation localization based on intraoperative three-dimensional ultrasound and catheter path for image-guided catheter intervention of oral cancers. Comput Med Imaging Graph 37(2):113\u2013122. https:\/\/doi.org\/10.1016\/j.compmedimag.2013.01.007","journal-title":"Comput Med Imaging Graph"},{"issue":"1","key":"3059_CR6","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1007\/s12928-019-00603-y","volume":"35","author":"S Sonoda","year":"2020","unstructured":"Sonoda S, Hibi K, Okura H, Fujii K, Honda Y, Kobayashi Y (2020) Current clinical use of intravascular ultrasound imaging to guide percutaneous coronary interventions. Cardiovasc Interv Ther 35(1):30\u201336. https:\/\/doi.org\/10.1007\/s12928-019-00603-y","journal-title":"Cardiovasc Interv Ther"},{"issue":"4","key":"3059_CR7","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1002\/rcs.1736","volume":"12","author":"C Shi","year":"2016","unstructured":"Shi C, Tercero C, Wu X, Ikeda S, Komori K, Yamamoto K, Arai F, Fukuda T (2016) Real-time in vitro intravascular reconstruction and navigation for endovascular aortic stent grafting. Int J Med Robot 12(4):648\u2013657. https:\/\/doi.org\/10.1002\/rcs.1736","journal-title":"Int J Med Robot"},{"issue":"2","key":"3059_CR8","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1109\/lra.2016.2524984","volume":"1","author":"L Zhao","year":"2016","unstructured":"Zhao L, Giannarou S, Lee S-L, Yang G-Z (2016) SCEM+: real-time robust simultaneous catheter and environment modeling for endovascular navigation. IEEE Robot Autom Lett 1(2):961\u2013968. https:\/\/doi.org\/10.1109\/lra.2016.2524984","journal-title":"IEEE Robot Autom Lett"},{"issue":"3","key":"3059_CR9","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1109\/JBHI.2017.2703903","volume":"22","author":"C Shi","year":"2018","unstructured":"Shi C, Luo X, Guo J, Najdovski Z, Fukuda T, Ren H (2018) Three-dimensional intravascular reconstruction techniques based on intravascular ultrasound: a technical review. IEEE J Biomed Health Inform 22(3):806\u2013817. https:\/\/doi.org\/10.1109\/JBHI.2017.2703903","journal-title":"IEEE J Biomed Health Inform"},{"issue":"03","key":"3059_CR10","doi-asserted-by":"publisher","first-page":"1640009","DOI":"10.1142\/s2424905x16400092","volume":"01","author":"C Gruijthuijsen","year":"2016","unstructured":"Gruijthuijsen C, Rosa B, Tran PT, Sloten JV, Poorten EV, Reynaerts D (2016) An automatic registration method for radiation-free catheter navigation guidance. J Med Robot Res 01(03):1640009. https:\/\/doi.org\/10.1142\/s2424905x16400092","journal-title":"J Med Robot Res"},{"issue":"10","key":"3059_CR11","doi-asserted-by":"publisher","first-page":"3540","DOI":"10.3390\/s21103540","volume":"21","author":"C Peng","year":"2021","unstructured":"Peng C, Wu H, Kim S, Dai X, Jiang X (2021) Recent advances in transducers for intravascular ultrasound (IVUS) imaging. Sensors (Basel) 21(10):3540. https:\/\/doi.org\/10.3390\/s21103540","journal-title":"Sensors (Basel)"},{"issue":"4","key":"3059_CR12","doi-asserted-by":"publisher","first-page":"1407","DOI":"10.4067\/S0717-95022013000400042","volume":"31","author":"M Acar","year":"2013","unstructured":"Acar M, Salbacak A, Sakarya ME, Zararsiz I, Ulusoy M (2013) The morphometrical analysis of the external carotid artery and its branches with multidetector computerized tomography angiography technique. Int J Morphol 31(4):1407\u20131414. https:\/\/doi.org\/10.4067\/S0717-95022013000400042","journal-title":"Int J Morphol"},{"key":"3059_CR13","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-023-02992-1","author":"T Ohya","year":"2023","unstructured":"Ohya T, Sakuma I, Cai W, Kobayashi E, Koizumi T, Mitsudo K (2023) Diameters of lingual, facial, and maxillary arteries measured according to an objective protocol on 3D computed tomography angiography images. Int J Comput Assist Radiol Surg. https:\/\/doi.org\/10.1007\/s11548-023-02992-1","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"3","key":"3059_CR14","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1002\/rcs.1416","volume":"8","author":"C Shi","year":"2012","unstructured":"Shi C, Tercero C, Ikeda S, Ooe K, Fukuda T, Komori K, Yamamoto K (2012) In vitro three-dimensional aortic vasculature modeling based on sensor fusion between intravascular ultrasound and magnetic tracker. Int J Med Robot 8(3):291\u2013299. https:\/\/doi.org\/10.1002\/rcs.1416","journal-title":"Int J Med Robot"},{"issue":"2","key":"3059_CR15","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1002\/rcs.234","volume":"5","author":"Y Fu","year":"2009","unstructured":"Fu Y, Liu H, Wang S, Deng W, Li X, Liang Z (2009) Skeleton-based active catheter navigation. Int J Med Robot 5(2):125\u2013135. https:\/\/doi.org\/10.1002\/rcs.234","journal-title":"Int J Med Robot"},{"issue":"2","key":"3059_CR16","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/s12928-015-0349-x","volume":"31","author":"Y Kobayashi","year":"2016","unstructured":"Kobayashi Y, Kitahara H, Tanaka S, Okada K, Kimura T, Ikeno F, Yock PG, Fitzgerald PJ, Honda Y (2016) Quantitative precision of optical frequency domain imaging: direct comparison with frequency domain optical coherence tomography and intravascular ultrasound. Cardiovasc Interv Ther 31(2):79\u201388. https:\/\/doi.org\/10.1007\/s12928-015-0349-x","journal-title":"Cardiovasc Interv Ther"},{"key":"3059_CR17","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1109\/Tci.2022.3194722","volume":"8","author":"BJ Li","year":"2022","unstructured":"Li BJ, Zhang PF, Cao YK, Sun LK, Feng JQ, Zhang YZ, Yang Q, Li YJ, Liu Z (2022) AIVUS: guidewire artifacts inpainting for intravascular ultrasound imaging with united spatiotemporal aggregation learning. IEEE Trans Comput Imaging 8:679\u2013692. https:\/\/doi.org\/10.1109\/Tci.2022.3194722","journal-title":"IEEE Trans Comput Imaging"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03059-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-024-03059-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03059-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,23]],"date-time":"2024-11-23T12:06:28Z","timestamp":1732363588000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-024-03059-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,18]]},"references-count":17,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2024,8]]}},"alternative-id":["3059"],"URL":"https:\/\/doi.org\/10.1007\/s11548-024-03059-5","relation":{},"ISSN":["1861-6429"],"issn-type":[{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2024,1,18]]},"assertion":[{"value":"11 January 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 January 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 January 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}