{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T23:21:11Z","timestamp":1794093671402,"version":"4.8.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2024,3,16]],"date-time":"2024-03-16T00:00:00Z","timestamp":1710547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,3,16]],"date-time":"2024-03-16T00:00:00Z","timestamp":1710547200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Convergence for Health and Technology program between Erasmus MC, University Medical Center Rotterdam, The Netherlands and Delft University of Technology, Delft, The Netherlands"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>For tumor resection, surgeons need to localize the tumor. For this purpose, a magnetic seed can be inserted into the tumor by a radiologist and, during surgery, a magnetic detection probe informs the distance to the seed for localization. In this case, the surgeon still needs to mentally reconstruct the position of the tumor from the probe\u2019s information. The purpose of this study is to develop and assess a method for 3D localization and visualization of the seed, facilitating the localization of the tumor.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>We propose a method for 3D localization of the magnetic seed by extending the magnetic detection probe with a tracking-based localization. We attach a position sensor (QR-code or optical marker) to the probe in order to track its 3D pose (respectively, using a head-mounted display with a camera or optical tracker). Following an acquisition protocol, the 3D probe tip and seed position are subsequently obtained by solving a system of equations based on the distances and the 3D probe poses.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The method was evaluated with an optical tracking system. An experimental setup using QR-code tracking (resp. using an optical marker) achieves an average of 1.6\u00a0mm (resp. 0.8\u00a0mm) 3D distance between the localized seed and the ground truth. Using a breast phantom setup, the average 3D distance is 4.7\u00a0mm with a QR-code and 2.1\u00a0mm with an optical marker.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Tracking the magnetic detection probe allows 3D localization of a magnetic seed, which opens doors for augmented reality target visualization during surgery. Such an approach should enhance the perception of the localized region of interest during the intervention, especially for breast tumor resection where magnetic seeds can already be used in the protocol.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-024-03066-6","type":"journal-article","created":{"date-parts":[[2024,3,16]],"date-time":"2024-03-16T12:01:33Z","timestamp":1710590493000},"page":"723-733","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["3D magnetic seed localization for augmented reality in surgery"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4900-2501","authenticated-orcid":false,"given":"Pierre","family":"Ambrosini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara","family":"AzizianAmiri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eliane","family":"Zeestraten","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tessa","family":"van Ginhoven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ricardo","family":"Marroquim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theo","family":"van Walsum","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,3,16]]},"reference":[{"key":"3066_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.clinimag.2019.01.013","volume":"56","author":"RC Mayo III","year":"2019","unstructured":"Mayo RC III, Kalambo MJ, Parikh JR (2019) Preoperative localization of breast lesions: current techniques. Clin Imaging 56:1\u20138","journal-title":"Clin Imaging"},{"key":"3066_CR2","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1053\/j.ro.2021.12.007","volume":"57","author":"C Kasales","year":"2022","unstructured":"Kasales C (2022) Wireless localization of breast lesions: an update. Semin Roentgenol 57:139\u2013144","journal-title":"Semin Roentgenol"},{"key":"3066_CR3","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.breast.2017.03.003","volume":"33","author":"B Schermers","year":"2017","unstructured":"Schermers B, Hage JA, Loo C, Peeters MV, Winter-Warnars H, Duijnhoven F, Ten Haken B, Muller S, Ruers T (2017) Feasibility of magnetic marker localisation for non-palpable breast cancer. The Breast 33:50\u201356","journal-title":"The Breast"},{"issue":"3","key":"3066_CR4","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1007\/s10549-018-4709-y","volume":"169","author":"JR Harvey","year":"2018","unstructured":"Harvey JR, Lim Y, Murphy J, Howe M, Morris J, Goyal A, Maxwell AJ (2018) Safety and feasibility of breast lesion localization using magnetic seeds (Magseed): a multi-centre, open-label cohort study. Breast Cancer Res Treat 169(3):531\u2013536","journal-title":"Breast Cancer Res Treat"},{"issue":"2","key":"3066_CR5","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.ejso.2021.12.270","volume":"48","author":"H Galema","year":"2022","unstructured":"Galema H, Mulder EE, Grunhagen DJ, Gils RA, Ginhoven TM, Zeestraten EC, Verhoef C, Hilling DE (2022) Successful use of a magnetic localisation system for non-palpable malignant lesions: a single centre experience. Eur J Surg Oncol 48(2):141","journal-title":"Eur J Surg Oncol"},{"issue":"3","key":"3066_CR6","doi-asserted-by":"publisher","first-page":"1629","DOI":"10.3390\/app13031629","volume":"13","author":"S Malhotra","year":"2023","unstructured":"Malhotra S, Halabi O, Dakua SP, Padhan J, Paul S, Palliyali W (2023) Augmented reality in surgical navigation: a review of evaluation and validation metrics. Appl Sci 13(3):1629","journal-title":"Appl Sci"},{"key":"3066_CR7","doi-asserted-by":"publisher","first-page":"4574172","DOI":"10.1155\/2017\/4574172","volume":"2017","author":"P V\u00e1vra","year":"2017","unstructured":"V\u00e1vra P, Roman J, Zon\u010da P, Ihn\u00e1t P, N\u011bmec M, Kumar J, Habib N, El-Gendi A et al (2017) Recent development of augmented reality in surgery: a review. J Healthc Eng 2017:4574172","journal-title":"J Healthc Eng"},{"key":"3066_CR8","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1109\/RBME.2017.2773521","volume":"11","author":"J Zhang","year":"2017","unstructured":"Zhang J, Zhong Y, Gu C (2017) Deformable models for surgical simulation: a survey. IEEE Rev Biomed Eng 11:143\u2013164","journal-title":"IEEE Rev Biomed Eng"},{"issue":"3","key":"3066_CR9","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1109\/TBME.2017.2695587","volume":"65","author":"HP Bui","year":"2017","unstructured":"Bui HP, Tomar S, Courtecuisse H, Cotin S, Bordas SP (2017) Real-time error control for surgical simulation. IEEE Trans Biomed Eng 65(3):596\u2013607","journal-title":"IEEE Trans Biomed Eng"},{"key":"3066_CR10","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1109\/RBME.2019.2939091","volume":"13","author":"A Sorriento","year":"2019","unstructured":"Sorriento A, Porfido MB, Mazzoleni S, Calvosa G, Tenucci M, Ciuti G, Dario P (2019) Optical and electromagnetic tracking systems for biomedical applications: a critical review on potentialities and limitations. IEEE Rev Biomed Eng 13:212\u2013232","journal-title":"IEEE Rev Biomed Eng"},{"issue":"1","key":"3066_CR11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41698-019-0106-1","volume":"4","author":"EN Kok","year":"2020","unstructured":"Kok EN, Eppenga R, Kuhlmann KF, Groen HC, Veen R, Dieren JM, Wijkerslooth TR, Leerdam M, Lambregts DM, Heerink WJ, Hoetjes NJ, Ivashchenko O, Beets GL, Aalbers AG, Nijkamp J, Ruers TJ (2020) Accurate surgical navigation with real-time tumor tracking in cancer surgery. NPJ Precis Oncol 4(1):1\u20137","journal-title":"NPJ Precis Oncol"},{"issue":"3","key":"3066_CR12","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1109\/TBME.2015.2466591","volume":"63","author":"T Ungi","year":"2015","unstructured":"Ungi T, Gauvin G, Lasso A, Yeo CT, Pezeshki P, Vaughan T, Carter K, Rudan J, Engel CJ, Fichtinger G (2015) Navigated breast tumor excision using electromagnetically tracked ultrasound and surgical instruments. IEEE Trans Biomed Eng 63(3):600\u2013606","journal-title":"IEEE Trans Biomed Eng"},{"issue":"22","key":"3066_CR13","doi-asserted-by":"publisher","first-page":"6797","DOI":"10.1088\/0031-9155\/59\/22\/6797","volume":"59","author":"A Franz","year":"2014","unstructured":"Franz A, Schmitt D, Seitel A, Chatrasingh M, Echner G, Oelfke U, Nill S, Birkfellner W, Maier-Hein L (2014) Standardized accuracy assessment of the calypso wireless transponder tracking system. Phys Med Biol 59(22):6797","journal-title":"Phys Med Biol"},{"issue":"4","key":"3066_CR14","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1017\/S1460396914000223","volume":"13","author":"C Silva","year":"2014","unstructured":"Silva C, Mateus D, Eiras M, Vieira S (2014) Calypso\u00ae 4d localization system: a review. J Radiother Pract 13(4):473\u2013483","journal-title":"J Radiother Pract"},{"issue":"4","key":"3066_CR15","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1007\/s11548-017-1684-4","volume":"13","author":"N Janssen","year":"2018","unstructured":"Janssen N, Eppenga R, Vrancken Peeters M-J, Duijnhoven F, Oldenburg H, Hage J, Rutgers E, Sonke J-J, Kuhlmann K, Ruers T, Nijkamp J (2018) Real-time wireless tumor tracking during breast conserving surgery. Int J Comput Assist Radiol Surg 13(4):531\u2013539","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"2","key":"3066_CR16","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1007\/s11548-019-02088-9","volume":"15","author":"R Eppenga","year":"2020","unstructured":"Eppenga R, Kuhlmann K, Ruers T, Nijkamp J (2020) Accuracy assessment of target tracking using two 5-degrees-of-freedom wireless transponders. Int J Comput Assist Radiol Surg 15(2):369\u2013377","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"12","key":"3066_CR17","doi-asserted-by":"publisher","first-page":"1937","DOI":"10.1007\/s11548-018-1838-z","volume":"13","author":"R Eppenga","year":"2018","unstructured":"Eppenga R, Kuhlmann K, Ruers T, Nijkamp J (2018) Accuracy assessment of wireless transponder tracking in the operating room environment. Int J Comput Assist Radiol Surg 13(12):1937\u20131948","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"3","key":"3066_CR18","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1007\/s11263-012-0601-0","volume":"103","author":"R Hartley","year":"2013","unstructured":"Hartley R, Trumpf J, Dai Y, Li H (2013) Rotation averaging. Int J Comput Vis 103(3):267\u2013305","journal-title":"Int J Comput Vis"},{"key":"3066_CR19","doi-asserted-by":"crossref","unstructured":"Gsaxner C, Li J, Pepe A, Schmalstieg D, Egger J (2021) Inside-out instrument tracking for surgical navigation in augmented reality. In: Proceedings of the 27th ACM symposium on virtual reality software and technology, pp 1\u201311","DOI":"10.1145\/3489849.3489863"},{"issue":"4","key":"3066_CR20","doi-asserted-by":"publisher","first-page":"1637","DOI":"10.1007\/s10055-022-00653-3","volume":"26","author":"M Benmahdjoub","year":"2022","unstructured":"Benmahdjoub M, Niessen WJ, Wolvius EB, Tv Walsum (2022) Multimodal markers for technology-independent integration of augmented reality devices and surgical navigation systems. Virtual Real 26(4):1637\u20131650","journal-title":"Virtual Real"},{"key":"3066_CR21","unstructured":"Microsoft Mixed Reality Documentation. https:\/\/learn.microsoft.com\/en-us\/windows\/mixed-reality\/develop\/advanced-concepts\/hologram-stability"},{"issue":"5","key":"3066_CR22","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1007\/s11517-018-1929-6","volume":"57","author":"LT De Paolis","year":"2019","unstructured":"De Paolis LT, De Luca V (2019) Augmented visualization with depth perception cues to improve the surgeon\u2019s performance in minimally invasive surgery. Med Biol Eng Comput 57(5):995\u20131013","journal-title":"Med Biol Eng Comput"},{"key":"3066_CR23","doi-asserted-by":"crossref","unstructured":"Perkins SL, Lin MA, Srinivasan S, Wheeler AJ, Hargreaves BA, Daniel BL (2017) A mixed-reality system for breast surgical planning. In: 2017 IEEE international symposium on mixed and augmented reality (ISMAR-adjunct). IEEE, pp 269\u2013274","DOI":"10.1109\/ISMAR-Adjunct.2017.92"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03066-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-024-03066-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03066-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,28]],"date-time":"2024-03-28T02:22:39Z","timestamp":1711592559000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-024-03066-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,16]]},"references-count":23,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,4]]}},"alternative-id":["3066"],"URL":"https:\/\/doi.org\/10.1007\/s11548-024-03066-6","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,16]]},"assertion":[{"value":"28 June 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 January 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 March 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declaration"}},{"value":"Erasmus MC, University Medical Center Rotterdam, The Netherlands has a research agreement with Sirius Medical Systems B.V., The Netherlands. Sirius Medical Systems was not involved in the design or execution of the study. The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors. This article does not contain patient data.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}}]}}