{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,17]],"date-time":"2026-01-17T20:58:01Z","timestamp":1768683481119,"version":"3.49.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T00:00:00Z","timestamp":1717113600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T00:00:00Z","timestamp":1717113600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["465189657"],"award-info":[{"award-number":["465189657"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["13GW0473A"],"award-info":[{"award-number":["13GW0473A"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose:<\/jats:title>\n                <jats:p>The contour neurovascular system (CNS) is a novel device to treat intracranial wide-necked bifurcation aneurysms, with few studies assessing its long-term effects. Particularly its impact on aneurysm morphology has not been explored yet. We present a preliminary study to explore this impact for the first time, focusing on the neck curve and ostium of the aneurysm.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods:<\/jats:title>\n                <jats:p>We investigated seven aneurysms treated with the CNS to assess ostium deformation after CNS deployment by comparing models extracted from in vivo medical pre-treatment and follow-up scans via morphological analysis. Time between pre- and follow-up scans was ten months on average. Size and shape indices like area, neck diameter, ellipticity index, undulation index, and more were assessed.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results:<\/jats:title>\n                <jats:p>Ostium size was reduced after treatment. On average, ostium area was reduced at a rate of <jats:inline-formula><jats:alternatives><jats:tex-math>$$-$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mo>-<\/mml:mo>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula>0.58 (\u00b1 4.88)\u00a0mm<jats:sup>2<\/jats:sup> per year, from 15.52 (\u00b1 3.51)\u00a0mm<jats:sup>2<\/jats:sup> to 13.30 (\u00b1 2.27)\u00a0mm<jats:sup>2<\/jats:sup>, and ostium width from 5.01 (\u00b1 0.54)\u00a0mm to 4.49 (\u00b1 0.45)\u00a0mm, with an average reduction of <jats:inline-formula><jats:alternatives><jats:tex-math>$$-$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mo>-<\/mml:mo>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula>0.59 (\u00b1 0.87)\u00a0mm. This shrinking positively correlated with time passing. Shape deformation was low, though notably mean ellipticity index was reduced by 0.06 (\u00b1 0.15) on average, indicating ostia were less elongated after treatment.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion:<\/jats:title>\n                <jats:p>We interpret the shrinking of the ostium as part of the healing process. Shape changes were found to be small enough to conclude no shape deformation of the ostium from CNS deployment, but the analysis of more cases with more parameters and information is necessary.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-024-03189-w","type":"journal-article","created":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T12:02:27Z","timestamp":1717156947000},"page":"2321-2327","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Assessment of intracranial aneurysm neck deformation after contour deployment"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4108-6918","authenticated-orcid":false,"given":"Lena","family":"Spitz","sequence":"first","affiliation":[]},{"given":"Jana","family":"Korte","sequence":"additional","affiliation":[]},{"given":"Franziska","family":"Gaidzik","sequence":"additional","affiliation":[]},{"given":"Naomi","family":"Larsen","sequence":"additional","affiliation":[]},{"given":"Bernhard","family":"Preim","sequence":"additional","affiliation":[]},{"given":"Sylvia","family":"Saalfeld","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2024,5,31]]},"reference":[{"issue":"2","key":"3189_CR1","doi-asserted-by":"publisher","first-page":"141","DOI":"10.26443\/mjm.v9i2.672","volume":"9","author":"A Keedy","year":"2006","unstructured":"Keedy A (2006) An overview of intracranial aneurysms. Mcgill J Med 9(2):141\u2013146. https:\/\/doi.org\/10.26443\/mjm.v9i2.672","journal-title":"Mcgill J Med"},{"issue":"1","key":"3189_CR2","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1056\/NEJM199701023360106","volume":"336","author":"WI Schievink","year":"1997","unstructured":"Schievink WI (1997) Intracranial aneurysms. N Engl J Med 336(1):28\u201340. https:\/\/doi.org\/10.1056\/NEJM199701023360106","journal-title":"N Engl J Med"},{"issue":"9969","key":"3189_CR3","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1016\/S0140-6736(14)60975-2","volume":"385","author":"AJ Molyneux","year":"2015","unstructured":"Molyneux AJ, Birks J, Clarke A, Sneade M, Kerr RSC (2015) The durability of endovascular coiling versus neurosurgical clipping of ruptured cerebral aneurysms: 18 year follow-up of the UK cohort of the international subarachnoid aneurysm trial (isat). Lancet 385(9969):691\u2013697. https:\/\/doi.org\/10.1016\/S0140-6736(14)60975-2","journal-title":"Lancet"},{"issue":"2","key":"3189_CR4","doi-asserted-by":"publisher","first-page":"279","DOI":"10.3174\/ajnr.A4540","volume":"37","author":"J Caroff","year":"2016","unstructured":"Caroff J, Neki H, Mihalea C, D\u2019Argento F, Khalek HA, Ikka L, Moret J, Spelle L (2016) Flow-diverter stents for the treatment of saccular middle cerebral artery bifurcation aneurysms. AJNR Am J Neuroradiol 37(2):279\u2013284. https:\/\/doi.org\/10.3174\/ajnr.A4540","journal-title":"AJNR Am J Neuroradiol"},{"issue":"12","key":"3189_CR5","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1136\/neurintsurg-2017-013223","volume":"9","author":"D Fiorella","year":"2017","unstructured":"Fiorella D, Arthur AS, Emery E, Molyneux A, Pierot LA (2017) How safe and effective are existing treatments for wide-necked bifurcation aneurysms? Literature-based objective performance criteria for safety and effectiveness. J Neurointerv Surg 9(12):1197\u20131201. https:\/\/doi.org\/10.1136\/neurintsurg-2017-013223","journal-title":"J Neurointerv Surg"},{"key":"3189_CR6","doi-asserted-by":"publisher","DOI":"10.1177\/15910199221139546","author":"S Ghozy","year":"2022","unstructured":"Ghozy S, Lashin BI, Elfil M, Bilgin C, Kobeissi H, Shehata M, Kadirvel R, Kallmes DF (2022) The safety and effectiveness of the contour neurovascular system for the treatment of wide-necked aneurysms: a systematic review and meta-analysis of early experience. Interv Neuroradiol. https:\/\/doi.org\/10.1177\/15910199221139546","journal-title":"Interv Neuroradiol"},{"issue":"10","key":"3189_CR7","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1136\/neurintsurg-2019-015628","volume":"12","author":"CY Akhunbay-Fudge","year":"2020","unstructured":"Akhunbay-Fudge CY, Deniz K, Tyagi AK, Patankar T (2020) Endovascular treatment of wide-necked intracranial aneurysms using the novel contour neurovascular system: a single-center safety and feasibility study. J Neurointerv Surg 12(10):987\u2013992. https:\/\/doi.org\/10.1136\/neurintsurg-2019-015628","journal-title":"J Neurointerv Surg"},{"issue":"1","key":"3189_CR8","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1007\/s00062-020-00876-4","volume":"31","author":"P Bhogal","year":"2021","unstructured":"Bhogal P, Lylyk I, Chudyk J, Perez N, Bleise C, Lylyk P (2021) The contour-early human experience of a novel aneurysm occlusion device. Clin Neuroradiol 31(1):147\u2013154. https:\/\/doi.org\/10.1007\/s00062-020-00876-4","journal-title":"Clin Neuroradiol"},{"key":"3189_CR9","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1177\/15910199211069782","volume":"29","author":"F Wodarg","year":"2023","unstructured":"Wodarg F, Ozpeynirci Y, Hensler J, Jansen O, Liebig T (2023) Contour-assisted coiling with jailed microcatheter may result in better occlusion (cocojambo) in wide-necked intracranial aneurysms: proof of principle and immediate angiographic results. Interv Neuroradiol 29:79\u201387. https:\/\/doi.org\/10.1177\/15910199211069782","journal-title":"Interv Neuroradiol"},{"key":"3189_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1136\/jnis-2023-020403","volume":"55","author":"J Korte","year":"2023","unstructured":"Korte J, Gaidzik F, Larsen N, Sch\u00fctz E, Damm T, Wodarg F, H\u00f6vener J-B, Jansen O, Janiga G, Berg P, Pravdivtseva MS (2023) In vitro and in silico assessment of flow modulation after deploying the contour neurovascular system in intracranial aneurysm models. J NeuroIntervent Surg 55:1\u20139. https:\/\/doi.org\/10.1136\/jnis-2023-020403","journal-title":"J NeuroIntervent Surg"},{"issue":"1","key":"3189_CR11","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1515\/cdbme-2022-0033","volume":"8","author":"L Spitz","year":"2022","unstructured":"Spitz L, Allgaier M, Mpotsaris A, Behme D, Preim B, Saalfeld S (2022) Segmentation of circle of Willis from 7T TOF-MRI data and immersive exploration using VR. Curr Dir Biomed Eng 8(1):129\u2013132. https:\/\/doi.org\/10.1515\/cdbme-2022-0033","journal-title":"Curr Dir Biomed Eng"},{"key":"3189_CR12","doi-asserted-by":"publisher","unstructured":"Saalfeld S, Berg P, Niemann A, Luz M, Preim B, Beuing O (2018) Semiautomatic neck curve reconstruction for intracranial aneurysm rupture risk assessment based on morphological parameters. Int J Comput Assist Radiol Surg 13(11):1781\u20131793. https:\/\/doi.org\/10.1007\/s11548-018-1848-x","DOI":"10.1007\/s11548-018-1848-x"},{"issue":"2","key":"3189_CR13","doi-asserted-by":"publisher","first-page":"355","DOI":"10.3171\/jns.2005.102.2.0355","volume":"102","author":"ML Raghavan","year":"2005","unstructured":"Raghavan ML, Ma B, Harbaugh RE (2005) Quantified aneurysm shape and rupture risk. J Neurosurg 102(2):355\u2013362. https:\/\/doi.org\/10.3171\/jns.2005.102.2.0355","journal-title":"J Neurosurg"},{"key":"3189_CR14","doi-asserted-by":"publisher","unstructured":"Mittenentzwei S, Beuing O, Neyazi B, Sandalcioglu IE, Larsen N, Preim B, Saalfeld S (2021) Definition and extraction of 2d shape indices of intracranial aneurysm necks for rupture risk assessment. Int J Comput Assist Radiol Surg 16(11):1977\u20131984. https:\/\/doi.org\/10.1007\/s11548-021-02469-z","DOI":"10.1007\/s11548-021-02469-z"},{"issue":"4","key":"3189_CR15","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1007\/s00062-019-00854-5","volume":"30","author":"N Larsen","year":"2020","unstructured":"Larsen N, Fl\u00fch C, Madjidyar J, Synowitz M, Jansen O, Wodarg F (2020) Visualization of aneurysm healing: enhancement patterns and reperfusion in intracranial aneurysms after embolization on 3t vessel wall MRI. Clin Neuroradiol 30(4):811\u2013815. https:\/\/doi.org\/10.1007\/s00062-019-00854-5","journal-title":"Clin Neuroradiol"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03189-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-024-03189-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03189-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,29]],"date-time":"2024-11-29T15:14:01Z","timestamp":1732893241000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-024-03189-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,31]]},"references-count":15,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["3189"],"URL":"https:\/\/doi.org\/10.1007\/s11548-024-03189-w","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,31]]},"assertion":[{"value":"12 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 May 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 May 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors state no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}