{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T02:30:49Z","timestamp":1782354649833,"version":"3.54.5"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2024,8,10]],"date-time":"2024-08-10T00:00:00Z","timestamp":1723248000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,8,10]],"date-time":"2024-08-10T00:00:00Z","timestamp":1723248000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100005713","name":"Technische Universit\u00e4t M\u00fcnchen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100005713","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>\n                           <jats:bold>Introduction<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>In robotic-assisted surgery (RAS), the input device is the primary site for the flow of information between the user and the robot. Most RAS systems remove the surgeon\u2019s console from the sterile surgical site. Beneficial for performing lengthy procedures with complex systems, this ultimately lacks the flexibility that comes with the surgeon being able to remain at the sterile site.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>\n                           <jats:bold>Methods<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>A prototype of an input device for RAS is constructed. The focus lies on intuitive control for surgeons and a seamless integration into the surgical workflow within the sterile environment. The kinematic design is translated from the kinematics of laparoscopic surgery. The input device uses three degrees of freedom from a flexible instrument as input. The prototype\u2019s performance is compared to that of a commercially available device in an evaluation. Metrics are used to evaluate the surgeons\u2019 performance with the respective input device in a virtual environment implemented for the evaluation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>\n                           <jats:bold>Results<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>The evaluation of the two input devices shows statistically significant differences in the performance metrics. With the proposed prototype, the surgeons perform the tasks faster, more precisely, and with fewer errors.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>\n                           <jats:bold>Conclusion<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>The prototype is an efficient and intuitive input device for surgeons with laparoscopic experience. The placement in the sterile working area allows for seamless integration into the surgical workflow and can potentially enable new robotic approaches.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-024-03239-3","type":"journal-article","created":{"date-parts":[[2024,8,10]],"date-time":"2024-08-10T05:01:56Z","timestamp":1723266116000},"page":"2301-2309","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Development of a human machine interface for robotically assisted surgery optimized for laparoscopic workflows"],"prefix":"10.1007","volume":"19","author":[{"given":"Luca","family":"Wegener","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dirk","family":"Wilhelm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maximilian","family":"Berlet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonas","family":"Fuchtmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,8,10]]},"reference":[{"issue":"2","key":"3239_CR1","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1002\/bjs.9711","volume":"102","author":"M Diana","year":"2015","unstructured":"Diana M, Marescaux J (2015) Robotic surgery. The Br J Surg 102(2):15\u201328. https:\/\/doi.org\/10.1002\/bjs.9711","journal-title":"The Br J Surg"},{"issue":"1","key":"3239_CR2","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/S0016-5107(04)01309-4","volume":"60","author":"AN Kalloo","year":"2004","unstructured":"Kalloo AN, Singh VK, Jagannath SB, Niiyama H, Hill SL, Vaughn CA, Magee CA, Kantsevoy SV (2004) Flexible transgastric peritoneoscopy: a novel approach to diagnostic and therapeutic interventions in the peritoneal cavity. Gastrointest Endosc 60(1):114\u2013117. https:\/\/doi.org\/10.1016\/S0016-5107(04)01309-4","journal-title":"Gastrointest Endosc"},{"issue":"2","key":"3239_CR3","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1007\/s00464-005-3006-0","volume":"20","author":"D Rattner","year":"2006","unstructured":"Rattner D, Kalloo A (2006) Asge\/sages working group on natural orifice translumenal endoscopic surgery. Surg Endosc 20(2):329\u2013333. https:\/\/doi.org\/10.1007\/s00464-005-3006-0","journal-title":"Surg Endosc"},{"key":"3239_CR4","doi-asserted-by":"publisher","unstructured":"Curcillo PG, Wu AS, Podolsky ER, King SA (2011) Reduced-port-chirurgie: Entwicklung eines sicheren weges zur single-port-access-chirurgie. Der Chirurg: Zeitschrift fur alle Gebiete der operativen Medizen 82(5):391\u2013397. https:\/\/doi.org\/10.1007\/s00104-010-2003-6","DOI":"10.1007\/s00104-010-2003-6"},{"issue":"5","key":"3239_CR5","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1007\/s00464-011-1650-0","volume":"25","author":"D Renteln","year":"2011","unstructured":"Renteln D, Vassiliou MC, R\u00f6sch T, Rothstein RI (2011) Triangulation: The holy grail of endoscopic surgery? Surg Endosc 25(5):1355\u20131357. https:\/\/doi.org\/10.1007\/s00464-011-1650-0","journal-title":"Surg Endosc"},{"key":"3239_CR6","doi-asserted-by":"publisher","unstructured":"Donno A, Zorn L, Zanne P, Nageotte F, Mathelin M (2013) Introducing stras: a new flexible robotic system for minimally invasive surgery. In: 2013 IEEE International Conference on Robotics and Automation, pp 1213\u20131220. IEEE, Karlsruhe, Germany. https:\/\/doi.org\/10.1109\/ICRA.2013.6630726","DOI":"10.1109\/ICRA.2013.6630726"},{"key":"3239_CR7","doi-asserted-by":"publisher","unstructured":"Nageotte F, Zorn L, Zanne P, Mathelin M (2020) Stras: a modular and flexible telemanipulated robotic device for intraluminal surgery. In: Handbook of Robotic and Image-Guided Surgery, pp 123\u2013146. Elsevier, Amsterdam, Netherlands. https:\/\/doi.org\/10.1016\/B978-0-12-814245-5.00008-6","DOI":"10.1016\/B978-0-12-814245-5.00008-6"},{"issue":"7","key":"3239_CR8","doi-asserted-by":"publisher","first-page":"5303","DOI":"10.1007\/s00464-021-08908-x","volume":"36","author":"L Bernhard","year":"2022","unstructured":"Bernhard L, Krumpholz R, Krieger Y, Czempiel T, Meining A, Navab N, L\u00fcth T, Wilhelm D (2022) Plafokon: a new concept for a patient-individual and intervention-specific flexible surgical platform. Surg Endosc 36(7):5303\u20135312. https:\/\/doi.org\/10.1007\/s00464-021-08908-x","journal-title":"Surg Endosc"},{"issue":"8","key":"3239_CR9","doi-asserted-by":"publisher","first-page":"2117","DOI":"10.1007\/s00464-012-2182-y","volume":"26","author":"A Simorov","year":"2012","unstructured":"Simorov A, Otte RS, Kopietz CM, Oleynikov D (2012) Review of surgical robotics user interface: What is the best way to control robotic surgery? Surg Endosc 26(8):2117\u20132125. https:\/\/doi.org\/10.1007\/s00464-012-2182-y","journal-title":"Surg Endosc"},{"key":"3239_CR10","doi-asserted-by":"publisher","unstructured":"Freschi C, Ferrari V, Melfi F, Ferrari M, Mosca F, Cuschieri A (2013) Technical review of the da vinci surgical telemanipulator. The international journal of medical robotics + computer assisted surgery : MRCAS 9(4), 396\u2013406 https:\/\/doi.org\/10.1002\/rcs.1468","DOI":"10.1002\/rcs.1468"},{"issue":"3","key":"3239_CR11","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1109\/TMECH.2008.924118","volume":"13","author":"AD Greer","year":"2008","unstructured":"Greer AD, Newhook PM, Sutherland GR (2008) Human-machine interface for robotic surgery and stereotaxy. IEEE\/ASME Trans Mechatron 13(3):355\u2013361. https:\/\/doi.org\/10.1109\/TMECH.2008.924118","journal-title":"IEEE\/ASME Trans Mechatron"},{"issue":"9","key":"3239_CR12","doi-asserted-by":"publisher","first-page":"1183","DOI":"10.1177\/0278364909101795","volume":"28","author":"MJH Lum","year":"2009","unstructured":"Lum MJH, Friedman DCW, Sankaranarayanan G, King H, Fodero K, Leuschke R, Hannaford B, Rosen J, Sinanan MN (2009) The raven: design and validation of a telesurgery system. The Int J Robot Res 28(9):1183\u20131197. https:\/\/doi.org\/10.1177\/0278364909101795","journal-title":"The Int J Robot Res"},{"key":"3239_CR13","doi-asserted-by":"publisher","unstructured":"Tobergte A, Helmer P, Hagn U, Rouiller P, Thielmann S, Grange S, Albu-Schaffer A, Conti F, Hirzinger G (2011) The sigma.7 haptic interface for mirosurge: a new bi-manual surgical console. In: 2011 IEEE\/RSJ International Conference on Intelligent Robots and Systems, pp 3023\u20133030. IEEE, San Francisco, USA. https:\/\/doi.org\/10.1109\/IROS.2011.6048043","DOI":"10.1109\/IROS.2011.6048043"},{"issue":"1","key":"3239_CR14","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.jss.2011.06.034","volume":"171","author":"I Oropesa","year":"2011","unstructured":"Oropesa I, S\u00e1nchez-Gonz\u00e1lez P, Lamata P, Chmarra MK, Pagador JB, S\u00e1nchez-Margallo JA, S\u00e1nchez-Margallo FM, G\u00f3mez EJ (2011) Methods and tools for objective assessment of psychomotor skills in laparoscopic surgery. The J Surg Res 171(1):81\u201395. https:\/\/doi.org\/10.1016\/j.jss.2011.06.034","journal-title":"The J Surg Res"},{"key":"3239_CR15","doi-asserted-by":"publisher","unstructured":"Fried GM, Feldman LS (2008) Objective assessment of technical performance. World J Surg 32(2):156\u2013160. https:\/\/doi.org\/10.1007\/s00268-007-9143-y","DOI":"10.1007\/s00268-007-9143-y"},{"issue":"6","key":"3239_CR16","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1016\/S0002-9610(98)00080-4","volume":"175","author":"AM Derossis","year":"1998","unstructured":"Derossis AM, Fried GM, Abrahamowicz M, Sigman HH, Barkun JS, Meakins JL (1998) Development of a model for training and evaluation of laparoscopic skills. Am J Surg 175(6):482\u2013487. https:\/\/doi.org\/10.1016\/S0002-9610(98)00080-4","journal-title":"Am J Surg"},{"issue":"2","key":"3239_CR17","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1001\/archsurg.1997.01430260098021","volume":"132","author":"JC Rosser","year":"1997","unstructured":"Rosser JC, Rosser LE, Savalgi RS (1997) Skill acquisition and assessment for laparoscopic surgery. Archiv Surg 132(2):200\u2013204. https:\/\/doi.org\/10.1001\/archsurg.1997.01430260098021","journal-title":"Archiv Surg"},{"key":"3239_CR18","doi-asserted-by":"publisher","unstructured":"Cotin S, Stylopoulos N, Ottensmeyer M, Neumann P, Rattner D, Dawson S (2002) Metrics for laparoscopic skills trainers: The weakest link! In: Medical Image Computing and Computer-Assisted Intervention \u2014 MICCAI 2002. Lecture Notes in Computer Science, vol 2488, pp 35\u201343. Springer Berlin Heidelberg, Berlin, Heidelberg. https:\/\/doi.org\/10.1007\/3-540-45786-0_5","DOI":"10.1007\/3-540-45786-0_5"},{"issue":"3","key":"3239_CR19","doi-asserted-by":"publisher","first-page":"854","DOI":"10.1007\/s00464-012-2524-9","volume":"27","author":"EF Hofstad","year":"2013","unstructured":"Hofstad EF, V\u00e5penstad C, Chmarra MK, Lang\u00f8 T, Kuhry E, M\u00e5rvik R (2013) A study of psychomotor skills in minimally invasive surgery: what differentiates expert and nonexpert performance. Surg Endosc 27(3):854\u2013863. https:\/\/doi.org\/10.1007\/s00464-012-2524-9","journal-title":"Surg Endosc"},{"key":"3239_CR20","doi-asserted-by":"publisher","unstructured":"Despinoy F, Zemiti N, Forestier G, S\u00e1nchez A, Jannin P, Poignet P (2018) Evaluation of contactless human-machine interface for robotic surgical training. Int J Comput Assist Radiol Surg 13(1):13\u201324. https:\/\/doi.org\/10.1007\/s11548-017-1666-6","DOI":"10.1007\/s11548-017-1666-6"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03239-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-024-03239-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03239-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,29]],"date-time":"2024-11-29T15:14:50Z","timestamp":1732893290000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-024-03239-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,10]]},"references-count":20,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["3239"],"URL":"https:\/\/doi.org\/10.1007\/s11548-024-03239-3","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,10]]},"assertion":[{"value":"10 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 July 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 August 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Luca Wegener declares no conflict of interest. Jonas Fuchtmann declares no conflict of interest. Maximilian Berlet declares no conflict of interest. Dirk Wilhelm declares no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article contains no studies with patients or living animals performed by the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This article does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}