{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:25:04Z","timestamp":1740144304342,"version":"3.37.3"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,9,16]],"date-time":"2024-09-16T00:00:00Z","timestamp":1726444800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,9,16]],"date-time":"2024-09-16T00:00:00Z","timestamp":1726444800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100007534","name":"Nicholas and Elizabeth Slezak Super Center for Cardiac Research and Biomedical Engineering","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100007534","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>Catheter-based radiofrequency ablation for pulmonary vein isolation has become the first line of treatment for atrial fibrillation in recent years. This requires a rather accurate map of the left atrial sub-endocardial surface including the ostia of the pulmonary veins, which requires dense sampling of the surface and currently takes more than 10\u00a0min. The focus of this work is to provide left atrial visualization early in the procedure to ease procedure complexity and enable further workflows, such as using catheters that have difficulty sampling the surface.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>We propose a dense encoder\u2013decoder network with a novel regularization term to reconstruct the shape of the left atrium from partial data which is derived from simple catheter maneuvers. To train the network, we acquire a large dataset of 3D atria shapes and generate corresponding catheter trajectories, from which traversed point clouds are obtained. Once trained, we show that the suggested network can sufficiently approximate the atrium shape based on a given trajectory.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>We compare several network solutions for the 3D atrium reconstruction. We demonstrate that the solution proposed produces realistic visualization using partial acquisition within a 3-min time interval using human clinical cases.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s11548-024-03268-y","type":"journal-article","created":{"date-parts":[[2024,9,18]],"date-time":"2024-09-18T12:19:16Z","timestamp":1726661956000},"page":"405-414","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Neural network reconstruction of the left atrium using sparse catheter paths"],"prefix":"10.1007","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6643-6729","authenticated-orcid":false,"given":"Alon","family":"Baram","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Moshe","family":"Safran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomer","family":"Noy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nave","family":"Geri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hayit","family":"Greenspan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,9,16]]},"reference":[{"issue":"1","key":"3268_CR1","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1161\/CIRCRESAHA.120.316340","volume":"127","author":"J Kornej","year":"2020","unstructured":"Kornej J, B\u00f6rschel CS, Benjamin EJ, Schnabel RB (2020) Epidemiology of atrial fibrillation in the 21st century. Circ Res 127(1):4\u201320. https:\/\/doi.org\/10.1161\/CIRCRESAHA.120.316340","journal-title":"Circ Res"},{"issue":"3","key":"3268_CR2","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1111\/j.1540-8159.2008.02250.x","volume":"32","author":"GD Veenhuyzen","year":"2009","unstructured":"Veenhuyzen GD, Knecht S, O\u2019Neill MD, Phil D, Wright M, Nault I, Weerasooriya R, Miyazaki S, Sacher F, Hocini M, Ja\u00efs P, Ha\u00efssaguerre M (2009) Atrial tachycardias encountered during and after catheter ablation for atrial fibrillation: part I: classification, incidence, management. Pacing Clin Electrophysiol 32(3):393\u2013398","journal-title":"Pacing Clin Electrophysiol"},{"key":"3268_CR3","unstructured":"Sciarra L, De Ruvo E, De\u00a0Luca L, Rebecchi M, Minati M, Lanzillo C, Dottori S, Pitrone P, Lioy E, Calo L (2010) Utility of newly available carto 3 mapping system to guide catheter ablation of atrial fibrillation. In: European heart journal, vol 31, Oxford Univ Press Great Clarendon St, Oxford OX2 6DP, England, pp 560\u2013560"},{"issue":"6","key":"3268_CR4","doi-asserted-by":"publisher","first-page":"e470","DOI":"10.1016\/j.crvasa.2015.10.002","volume":"57","author":"T Sk\u00e1la","year":"2015","unstructured":"Sk\u00e1la T, T\u00e1borsk\u00fd M (2015) Electromechanical mapping in electrophysiology and beyond. Cor Vasa 57(6):e470\u2013e482. https:\/\/doi.org\/10.1016\/j.crvasa.2015.10.002","journal-title":"Cor Vasa"},{"issue":"19","key":"3268_CR5","doi-asserted-by":"publisher","first-page":"1798","DOI":"10.1016\/j.jacc.2009.02.022","volume":"53","author":"R Cappato","year":"2009","unstructured":"Cappato R, Calkins H, Chen S-A, Davies W, Iesaka Y, Kalman J, Kim Y-H, Klein G, Natale A, Packer D, Skanes A (2009) Prevalence and causes of fatal outcome in catheter ablation of atrial fibrillation. J Am Coll Cardiol 53(19):1798\u20131803. https:\/\/doi.org\/10.1016\/j.jacc.2009.02.022","journal-title":"J Am Coll Cardiol"},{"issue":"10","key":"3268_CR6","doi-asserted-by":"publisher","first-page":"1242","DOI":"10.1111\/j.1540-8159.2012.03492.x","volume":"35","author":"S-X Liu","year":"2012","unstructured":"Liu S-X, Zhang Y, Zhang X-W (2012) Impact of image integration on catheter ablation for atrial fibrillation using three-dimensional electroanatomic mapping: a meta-analysis. Pacing Clin Electrophysiol 35(10):1242\u20131247","journal-title":"Pacing Clin Electrophysiol"},{"issue":"6","key":"3268_CR7","doi-asserted-by":"publisher","first-page":"1795","DOI":"10.4022\/jafib.1795","volume":"10","author":"M Borlich","year":"2018","unstructured":"Borlich M, Iden L, Kuhnhardt K, Paetsch I, Hindricks G, Sommer P (2018) 3D mapping for PVI-geometry, image integration and incorporation of contact force into work flow. J Atr Fibrillation 10(6):1795","journal-title":"J Atr Fibrillation"},{"key":"3268_CR8","doi-asserted-by":"publisher","unstructured":"Baram A, Safran M, Ben-Cohen A, Greenspan H (2018) Left atria reconstruction from a series of sparse catheter paths using neural networks. In: Knoll F, Maier A, Rueckert D (eds) Machine learning for medical image reconstruction\u2014first international workshop, MLMIR 2018, held in conjunction with MICCAI 2018, proceedings, lecture notes in computer science (including subseries lecture notes in artificial intelligence and lecture notes in bioinformatics). Springer, pp 138\u2013146. https:\/\/doi.org\/10.1007\/978-3-030-00129-2_16","DOI":"10.1007\/978-3-030-00129-2_16"},{"issue":"1","key":"3268_CR9","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1145\/174462.156635","volume":"13","author":"H Edelsbrunner","year":"1994","unstructured":"Edelsbrunner H, M\u00fccke EP (1994) Three-dimensional alpha shapes. ACM Trans Graph 13(1):43\u201372. https:\/\/doi.org\/10.1145\/174462.156635","journal-title":"ACM Trans Graph"},{"key":"3268_CR10","unstructured":"Safran M,\u00a0Bar-tal M (2017) Model based reconstruction of the heart from sparse samples, US Patent 9,576,107 (Feb.\u00a021)"},{"key":"3268_CR11","first-page":"1","volume":"64","author":"AL Schwartz","year":"2021","unstructured":"Schwartz AL, Chorin E, Mann T, Hochstadt A, Margolis G, Viskin S, Banai S, Rosso R et al (2021) Reconstruction of the left atrium for atrial fibrillation ablation using the machine learning CARTO 3 m-FAM software. J Interv Card Electrophysiol 64:1\u20139","journal-title":"J Interv Card Electrophysiol"},{"key":"3268_CR12","unstructured":"Ahmed E, Saint A, Shabayek AER, Cherenkova K, Das R, Gusev G, Aouada D, Ottersten B (2019) A survey on deep learning advances on different 3D data representations. arXiv:1808.01462"},{"key":"3268_CR13","doi-asserted-by":"publisher","unstructured":"Milletari F, Navab N, Ahmadi SA (2016) V-Net: fully convolutional neural networks for volumetric medical image segmentation. In: Proceedings\u20142016 4th international conference on 3D vision, 3DV 2016. https:\/\/doi.org\/10.1109\/3DV.2016.79","DOI":"10.1109\/3DV.2016.79"},{"key":"3268_CR14","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2022.880260","volume":"13","author":"Z Xiong","year":"2022","unstructured":"Xiong Z, Stiles MK, Yao Y, Shi R, Nalar A, Hawson J, Lee G, Zhao J (2022) Automatic 3D surface reconstruction of the left atrium from clinically mapped point clouds using convolutional neural networks. Front Physiol 13:880260. https:\/\/doi.org\/10.3389\/fphys.2022.880260","journal-title":"Front Physiol"},{"key":"3268_CR15","volume-title":"Introduction to algorithms","author":"TH Cormen","year":"2009","unstructured":"Cormen TH, Leiserson CE, Rivest RL, Stein C (2009) Introduction to algorithms, 3rd edn. The MIT Press, Cambridge","edition":"3"},{"key":"3268_CR16","unstructured":"Kingma DP, Ba J (2014) Adam: a method for stochastic optimization. arXiv:1412.6980"},{"key":"3268_CR17","unstructured":"Ioffe S, Szegedy C (2015) Batch normalization: accelerating deep network training by reducing internal covariate shift. In: Proceedings of the 32nd international conference on international conference on machine learning, vol 37, ICML\u201915, JMLR.org, pp 448\u2013456"},{"key":"3268_CR18","doi-asserted-by":"crossref","unstructured":"Vincent P, Larochelle H, Bengio Y, Manzagol P-A (2008) Extracting and composing robust features with denoising autoencoders. In: Proceedings of the 25th international conference on machine learning. ACM, pp 1096\u20131103","DOI":"10.1145\/1390156.1390294"},{"issue":"12","key":"3268_CR19","doi-asserted-by":"publisher","first-page":"2262","DOI":"10.1109\/TPAMI.2010.46","volume":"32","author":"A Myronenko","year":"2010","unstructured":"Myronenko A, Song X (2010) Point set registration: coherent point drift. IEEE Trans Pattern Anal Mach Intell 32(12):2262\u20132275. https:\/\/doi.org\/10.1109\/TPAMI.2010.46","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"issue":"4","key":"3268_CR20","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1145\/37402.37422","volume":"21","author":"WE Lorensen","year":"1987","unstructured":"Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3D surface construction algorithm. SIGGRAPH Comput Graph 21(4):163\u2013169. https:\/\/doi.org\/10.1145\/37402.37422","journal-title":"SIGGRAPH Comput Graph"},{"key":"3268_CR21","unstructured":"Rockafellar R, Wets M, Wets R (2009) Variational analysis, grundlehren der mathematischen wissenschaften. Springer, Berlin, Heidelberg"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03268-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-024-03268-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03268-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,10]],"date-time":"2025-02-10T12:20:40Z","timestamp":1739190040000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-024-03268-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,16]]},"references-count":21,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,2]]}},"alternative-id":["3268"],"URL":"https:\/\/doi.org\/10.1007\/s11548-024-03268-y","relation":{},"ISSN":["1861-6429"],"issn-type":[{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2024,9,16]]},"assertion":[{"value":"21 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 August 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 September 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Alon Baram reports a relationship with Biosense Webster Inc that includes: employment. Alon Baram has patent Left Atrium Shape Reconstruction from Sparse Location Measurements using Neural Networks(20200029845) pending to Biosense Webster Inc. The authors have no other relevant financial or non-financial interests to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}