{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T23:03:39Z","timestamp":1778281419114,"version":"3.51.4"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2025,2,8]],"date-time":"2025-02-08T00:00:00Z","timestamp":1738972800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,2,8]],"date-time":"2025-02-08T00:00:00Z","timestamp":1738972800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100018703","name":"HORIZON EUROPE European Innovation Council","doi-asserted-by":"publisher","award":["101070443"],"award-info":[{"award-number":["101070443"]}],"id":[{"id":"10.13039\/100018703","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>Pars plana vitrectomy (PPV) is the most common surgical procedure performed by retinal specialists, highlighting the need for model-based assistance and automation in surgical treatment. An intraoperative retinal model provides precise anatomical information relative to the surgical instrument, enhancing surgical precision and safety.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This work focuses on the intraoperative parametrization of retinal shape using 1D instrument-integrated optical coherence tomography distance measurements combined with a surgical robot. Our approach accommodates variability in eye geometries by transitioning from an initial spherical model to an ellipsoidal representation, improving accuracy as more data is collected through sensor motion.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>We demonstrate that ellipsoid fitting outperforms sphere fitting for regular eye shapes, achieving a mean absolute error of less than 40\u00a0<jats:inline-formula>\n                <jats:alternatives>\n                  <jats:tex-math>$$\\upmu \\hbox {m}$$<\/jats:tex-math>\n                  <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>\u03bc<\/mml:mi>\n                      <mml:mtext>m<\/mml:mtext>\n                    <\/mml:mrow>\n                  <\/mml:math>\n                <\/jats:alternatives>\n              <\/jats:inline-formula> in simulation and below 200\u00a0<jats:inline-formula>\n                <jats:alternatives>\n                  <jats:tex-math>$$\\upmu \\hbox {m}$$<\/jats:tex-math>\n                  <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>\u03bc<\/mml:mi>\n                      <mml:mtext>m<\/mml:mtext>\n                    <\/mml:mrow>\n                  <\/mml:math>\n                <\/jats:alternatives>\n              <\/jats:inline-formula> on 3D printed models and ex vivo porcine eyes. The model reliably transitions from a spherical to an ellipsoidal representation across all six tested eye shapes when specific criteria are satisfied.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The adaptive eye model developed in this work meets the accuracy requirements for clinical application in PPV within the central retina. Additionally, the global model effectively extrapolates beyond the scanned area to encompass the retinal periphery.This capability enhances PPV procedures, particularly through virtual boundary assistance and improved surgical navigation, ultimately contributing to safer surgical outcomes.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s11548-025-03325-0","type":"journal-article","created":{"date-parts":[[2025,2,8]],"date-time":"2025-02-08T14:47:28Z","timestamp":1739026048000},"page":"881-889","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Intraoperative adaptive eye model based on instrument-integrated OCT for robot-assisted vitreoretinal surgery"],"prefix":"10.1007","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-1452-6607","authenticated-orcid":false,"given":"Marius","family":"Briel","sequence":"first","affiliation":[]},{"given":"Ludwig","family":"Haide","sequence":"additional","affiliation":[]},{"given":"Maximilian","family":"Hess","sequence":"additional","affiliation":[]},{"given":"Jan","family":"Schimmelpfennig","sequence":"additional","affiliation":[]},{"given":"Philipp","family":"Matten","sequence":"additional","affiliation":[]},{"given":"Rebekka","family":"Peter","sequence":"additional","affiliation":[]},{"given":"Matthias","family":"Hillenbrand","sequence":"additional","affiliation":[]},{"given":"Eleonora","family":"Tagliabue","sequence":"additional","affiliation":[]},{"given":"Franziska","family":"Mathis-Ullrich","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2025,2,8]]},"reference":[{"issue":"8","key":"3325_CR1","doi-asserted-by":"publisher","first-page":"2698","DOI":"10.1167\/iovs.04-1506","volume":"46","author":"DA Atchison","year":"2005","unstructured":"Atchison DA, Pritchard N, Schmid KL, Scott DH, Jones CE, Pope JM (2005) Shape of the retinal surface in emmetropia and myopia. Investig Ophthalmol Visual Sci 46(8):2698\u20132707. https:\/\/doi.org\/10.1167\/iovs.04-1506","journal-title":"Investig Ophthalmol Visual Sci"},{"issue":"5","key":"3325_CR2","doi-asserted-by":"publisher","first-page":"2386","DOI":"10.1364\/BOE.8.002386","volume":"8","author":"JM Pope","year":"2017","unstructured":"Pope JM, Verkicharla PK, Sepehrband F, Suheimat M, Schmid KL, Atchison DA (2017) Three-dimensional MRI study of the relationship between eye dimensions, retinal shape and myopia. Biomed Opt Express 8(5):2386\u20132395. https:\/\/doi.org\/10.1364\/BOE.8.002386","journal-title":"Biomed Opt Express"},{"key":"3325_CR3","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/503645","author":"I Bekerman","year":"2014","unstructured":"Bekerman I, Gottlieb P, Vaiman M (2014) Variations in eyeball diameters of the healthy adults. J Ophthalmol. https:\/\/doi.org\/10.1155\/2014\/503645","journal-title":"J Ophthalmol"},{"issue":"9","key":"3325_CR4","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1167\/iovs.15-18886","volume":"57","author":"AN Kuo","year":"2016","unstructured":"Kuo AN, Verkicharla PK, McNabb RP et al (2016) Posterior eye shape measurement with retinal OCT compared to MRI. Investig Ophthalmol Visual Sci 57(9):196\u2013203. https:\/\/doi.org\/10.1167\/iovs.15-18886","journal-title":"Investig Ophthalmol Visual Sci"},{"key":"3325_CR5","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-67940-4","author":"K Breher","year":"2020","unstructured":"Breher K, Ohlendorf A, Wahl S (2020) Myopia induces meridional growth asymmetry of the retina: a pilot study using wide-field swept-source OCT. Sci Rep. https:\/\/doi.org\/10.1038\/s41598-020-67940-4","journal-title":"Sci Rep"},{"issue":"1","key":"3325_CR6","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1109\/LRA.2017.2778020","volume":"3","author":"T Probst","year":"2018","unstructured":"Probst T, Maninis K-K, Chhatkuli A, Ourak M, Poorten EV, Gool LV (2018) Automatic tool landmark detection for stereo vision in robot-assisted retinal surgery. IEEE Robot Autom Lett 3(1):612\u2013619. https:\/\/doi.org\/10.1109\/LRA.2017.2778020","journal-title":"IEEE Robot Autom Lett"},{"key":"3325_CR7","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1186\/s40942-019-0165-z","volume":"5","author":"RS Ajlan","year":"2019","unstructured":"Ajlan RS, Desai AA, Mainster MA (2019) Endoscopic vitreoretinal surgery: principles, applications and new directions. Int J Retina Vitr 5:15. https:\/\/doi.org\/10.1186\/s40942-019-0165-z","journal-title":"Int J Retina Vitr"},{"issue":"2","key":"3325_CR8","doi-asserted-by":"publisher","first-page":"846","DOI":"10.1364\/BOE.477386","volume":"14","author":"A Britten","year":"2023","unstructured":"Britten A, Matten P, Weiss J et al (2023) Surgical microscope integrated MHz SS-OCT with live volumetric visualization. Biomed Opt Express 14(2):846\u2013865. https:\/\/doi.org\/10.1364\/BOE.477386","journal-title":"Biomed Opt Express"},{"key":"3325_CR9","doi-asserted-by":"publisher","unstructured":"Zhang P, Kim JW, Gehlbach PL, Iordachita II, Kobilarov M (2023) Autonomous needle navigation in retinal microsurgery: evaluation in ex vivo porcine eyes. In: 2023 IEEE International Conference on Robotics and Automation (ICRA), pp 4661\u20134667 . https:\/\/doi.org\/10.1109\/icra48891.2023.10161151","DOI":"10.1109\/icra48891.2023.10161151"},{"key":"3325_CR10","doi-asserted-by":"publisher","unstructured":"Zhou D, Takeyama H, Nakao S, Sonoda K, Tadano K (2023) Real-time fundus reconstruction and intraocular mapping using an ophthalmic endoscope. Int J Med Robot Comput Assist Surg 19(3):2496. https:\/\/doi.org\/10.1002\/rcs.2496","DOI":"10.1002\/rcs.2496"},{"key":"3325_CR11","doi-asserted-by":"publisher","unstructured":"Sommersperger M, Weiss J, Nasseri MA, Gehlbach P, Iordachita I, Navab N (2021) Real-time tool to layer distance estimation for robotic subretinal injection using intraoperative 4D OCT. Biomed Opt Express 12(2):1085\u20131104. https:\/\/doi.org\/10.1364\/BOE.415477","DOI":"10.1364\/BOE.415477"},{"issue":"4","key":"3325_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.xops.2021.100085","volume":"1","author":"MG Cereda","year":"2021","unstructured":"Cereda MG, Parrulli S, Douven YGM et al (2021) Clinical evaluation of an instrument-integrated OCT-based distance sensor for robotic vitreoretinal surgery. Ophthalmol Sci 1(4):100085. https:\/\/doi.org\/10.1016\/j.xops.2021.100085","journal-title":"Ophthalmol Sci"},{"key":"3325_CR13","doi-asserted-by":"publisher","unstructured":"Balicki M, Han J, Iordachita I (2009) et al.: Single fiber optical coherence tomography microsurgical instruments for computer and robot-assisted retinal surgery. In: Medical image computing and computer-assisted intervention\u2013MICCAI 2009, pp. 108\u2013115. Springer, Berlin, Heidelberg . https:\/\/doi.org\/10.1007\/978-3-642-04268-3_14","DOI":"10.1007\/978-3-642-04268-3_14"},{"issue":"13","key":"3325_CR14","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1167\/tvst.10.13.19","volume":"10","author":"A Abid","year":"2021","unstructured":"Abid A, Duval R, Rezende F, Boutopoulos C (2021) A smart vitrector equipped by a fiber-based OCT sensor mitigates intentional attempts at creating iatrogenic retinal breaks during vitrectomy in pigs. Transl Vision Sci Technol 10(13):19\u201319. https:\/\/doi.org\/10.1167\/tvst.10.13.19","journal-title":"Transl Vision Sci Technol"},{"key":"3325_CR15","doi-asserted-by":"publisher","unstructured":"Cornelissen P, Ourak M, Borghesan G, Reynaerts D, Poorten EV (2019) Towards real-time estimation of a spherical eye model based on a single fiber OCT. In: 2019 19th international conference on advanced robotics (ICAR), pp. 666\u2013672 . https:\/\/doi.org\/10.1109\/ICAR46387.2019.8981620","DOI":"10.1109\/ICAR46387.2019.8981620"},{"issue":"5","key":"3325_CR16","doi-asserted-by":"publisher","first-page":"1942","DOI":"10.1364\/BOE.6.001942","volume":"6","author":"GW Cheon","year":"2015","unstructured":"Cheon GW, Huang Y, Cha J-D, Gehlbach PL, Kang JU (2015) Accurate real-time depth control for CP-SSOCT distal sensor based handheld microsurgery tools. Biomed Opt Express 6(5):1942\u20131953. https:\/\/doi.org\/10.1364\/BOE.6.001942","journal-title":"Biomed Opt Express"},{"key":"3325_CR17","doi-asserted-by":"publisher","unstructured":"Li Q, Griffiths JG (2004) Least squares ellipsoid specific fitting. In: Geometric modeling and processing, 2004. Proceedings, pp. 335\u2013340 . https:\/\/doi.org\/10.1109\/GMAP.2004.1290055","DOI":"10.1109\/GMAP.2004.1290055"},{"key":"3325_CR18","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1109\/TSP.2023.3332560","volume":"72","author":"O Melikechi","year":"2024","unstructured":"Melikechi O, Dunson DB (2024) Ellipsoid fitting with the Cayley transform. IEEE Trans Signal Process 72:70\u201383. https:\/\/doi.org\/10.1109\/TSP.2023.3332560","journal-title":"IEEE Trans Signal Process"},{"issue":"3","key":"3325_CR19","doi-asserted-by":"publisher","first-page":"6598","DOI":"10.1109\/LRA.2022.3176453","volume":"7","author":"C Sifferman","year":"2022","unstructured":"Sifferman C, Mehrotra D, Gupta M, Gleicher M (2022) Geometric calibration of single-pixel distance sensors. IEEE Robot Autom Lett 7(3):6598\u20136605. https:\/\/doi.org\/10.1109\/LRA.2022.3176453","journal-title":"IEEE Robot Autom Lett"},{"issue":"8","key":"3325_CR20","doi-asserted-by":"publisher","first-page":"4510","DOI":"10.1167\/iovs.12-9426","volume":"53","author":"M Moriyama","year":"2012","unstructured":"Moriyama M, Ohno-Matsui K, Modegi T et al (2012) Quantitative analyses of high-resolution 3D MR images of highly myopic eyes to determine their shapes. Investig Ophthalmol Visual Sci 53(8):4510\u20134518. https:\/\/doi.org\/10.1167\/iovs.12-9426","journal-title":"Investig Ophthalmol Visual Sci"},{"issue":"4","key":"3325_CR21","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1080\/02713689808951218","volume":"17","author":"NC Strang","year":"1998","unstructured":"Strang NC, Schmid KL, Carney LG (1998) Hyperopia is predominantly axial in nature. Curr Eye Res 17(4):380\u2013383. https:\/\/doi.org\/10.1080\/02713689808951218","journal-title":"Curr Eye Res"},{"issue":"2","key":"3325_CR22","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1109\/TSP.2011.2172431","volume":"60","author":"F Gustafsson","year":"2012","unstructured":"Gustafsson F, Hendeby G (2012) Some relations between extended and unscented Kalman filters. IEEE Trans Signal Process 60(2):545\u2013555. https:\/\/doi.org\/10.1109\/TSP.2011.2172431","journal-title":"IEEE Trans Signal Process"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03325-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-025-03325-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03325-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,6]],"date-time":"2025-05-06T12:51:41Z","timestamp":1746535901000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-025-03325-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,8]]},"references-count":22,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2025,5]]}},"alternative-id":["3325"],"URL":"https:\/\/doi.org\/10.1007\/s11548-025-03325-0","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,8]]},"assertion":[{"value":"6 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 January 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 February 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no Conflict of interest to declare that are relevant to the content of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}