{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T03:40:34Z","timestamp":1775014834223,"version":"3.50.1"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2025,5,23]],"date-time":"2025-05-23T00:00:00Z","timestamp":1747958400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,23]],"date-time":"2025-05-23T00:00:00Z","timestamp":1747958400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","award":["[EP\/T029404\/1]"],"award-info":[{"award-number":["[EP\/T029404\/1]"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100009127","name":"Invention for Innovation Programme","doi-asserted-by":"publisher","award":["NIHR II-LA-1116-20005"],"award-info":[{"award-number":["NIHR II-LA-1116-20005"]}],"id":[{"id":"10.13039\/501100009127","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100009127","name":"Invention for Innovation Programme","doi-asserted-by":"publisher","award":["[203145Z\/16\/Z]"],"award-info":[{"award-number":["[203145Z\/16\/Z]"]}],"id":[{"id":"10.13039\/501100009127","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>\n              <jats:bold>Purpose<\/jats:bold>\n            <\/jats:title>\n            <jats:p>Registration of computed tomography (CT) to laparoscopic video images is vital to enable augmented reality (AR), a technology that holds the promise of minimising the risk of complications during laparoscopic liver surgery. Although several solutions have been presented in the literature, they always rely on an accurate initialisation of the registration that is either obtained manually or automatically estimated on very specific views of the liver. These limitations pose a challenge to the clinical translation of AR.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>\n              <jats:bold>Methods<\/jats:bold>\n            <\/jats:title>\n            <jats:p>We propose the use of a content-based image retrieval (CBIR) framework to obtain an automatic robust initialisation to the registration. Instead of directly registering video and CT, we render a dense set of possible views of the liver from CT and extract liver contour features. To reduce feature maps to lower dimension vectors, we use a deep hashing (DH) network that is trained in a triplet scheme. Registration is obtained by matching the intra-operative image hashing encoding to the closest encodings found in the pre-operative renderings.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>\n              <jats:bold>Results<\/jats:bold>\n            <\/jats:title>\n            <jats:p>We validate our method on synthetic and real data from a phantom and real patient data from eight surgeries. Phantom experiments show that registration errors acceptable for an initial registration are obtained if sufficient pre-operative solutions are considered. In seven out of eight patients, the method is able to obtain a clinically relevant alignment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>\n              <jats:bold>Conclusion<\/jats:bold>\n            <\/jats:title>\n            <jats:p>We present the first work to adapt DH to the CT to video registration problem. Our results indicate that this framework can effectively replace manual initialisations in multiple views, potentially increasing the translation of these techniques.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s11548-025-03418-w","type":"journal-article","created":{"date-parts":[[2025,5,23]],"date-time":"2025-05-23T00:36:37Z","timestamp":1747960597000},"page":"1461-1469","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Deep hashing for global registration of preoperative CT and video images for laparoscopic liver surgery"],"prefix":"10.1007","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-1232-2608","authenticated-orcid":false,"given":"Hanyuan","family":"Zhang","sequence":"first","affiliation":[]},{"given":"Sandun","family":"Bulathsinhala","sequence":"additional","affiliation":[]},{"given":"Brian R.","family":"Davidson","sequence":"additional","affiliation":[]},{"given":"Matthew J.","family":"Clarkson","sequence":"additional","affiliation":[]},{"given":"Jo\u00e3o","family":"Ramalhinho","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2025,5,23]]},"reference":[{"key":"3418_CR1","doi-asserted-by":"publisher","first-page":"4702","DOI":"10.1007\/s00464-020-07807-x","volume":"34","author":"C Schneider","year":"2020","unstructured":"Schneider C, Thompson S, Totz J, Song Y, Allam M, Sodergren M, Desjardins A, Barratt D, Ourselin S, Gurusamy K (2020) Comparison of manual and semi-automatic registration in augmented reality image-guided liver surgery: a clinical feasibility study. Surg. Endosc. 34:4702\u20134711","journal-title":"Surg. Endosc."},{"key":"3418_CR2","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2023.102943","volume":"90","author":"J Ramalhinho","year":"2023","unstructured":"Ramalhinho J, Yoo S, Dowrick T, Koo B, Somasundaram M, Gurusamy K, Hawkes DJ, Davidson B, Blandford A, Clarkson MJ (2023) The value of augmented reality in surgery\u2013a usability study on laparoscopic liver surgery. Med. Imag. Anal. 90:102943","journal-title":"Med. Imag. Anal."},{"key":"3418_CR3","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2024.103371","volume":"99","author":"S Ali","year":"2025","unstructured":"Ali S, Espinel Y, Jin Y, Liu P, G\u00fcttner B, Zhang X, Zhang L, Dowrick T, Clarkson MJ, Xiao S (2025) An objective comparison of methods for augmented reality in laparoscopic liver resection by preoperative-to-intraoperative image fusion from the miccai2022 challenge. Medical image analysis 99:103371","journal-title":"Medical image analysis"},{"key":"3418_CR4","first-page":"1499","volume":"11","author":"M Fusaglia","year":"2016","unstructured":"Fusaglia M, Hess H, Schwalbe M, Peterhans M, Tinguely P, Weber S, Lu H (2016) A clinically applicable laser-based image-guided system for laparoscopic liver procedures. IJCARS 11:1499\u20131513","journal-title":"IJCARS"},{"key":"3418_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2020.101946","volume":"69","author":"E Pelanis","year":"2021","unstructured":"Pelanis E, Teatini A, Eigl B, Regensburger A, Alzaga A, Kumar RP, Rudolph T, Aghayan DL, Riediger C, Kvarnstr\u00f6m N (2021) Evaluation of a novel navigation platform for laparoscopic liver surgery with organ deformation compensation using injected fiducials. Med. Imag. Anal. 69:101946","journal-title":"Med. Imag. Anal."},{"key":"3418_CR6","first-page":"947","volume":"13","author":"MR Robu","year":"2018","unstructured":"Robu MR, Ramalhinho J, Thompson S, Gurusamy K, Davidson B, Hawkes D, Stoyanov D, Clarkson MJ (2018) Global rigid registration of ct to video in laparoscopic liver surgery. IJCARS 13:947\u2013956","journal-title":"IJCARS"},{"key":"3418_CR7","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2019.105099","volume":"187","author":"H Luo","year":"2020","unstructured":"Luo H, Yin D, Zhang S, Xiao D, He B, Meng F, Zhang Y, Cai W, He S, Zhang W (2020) Augmented reality navigation for liver resection with a stereoscopic laparoscope. Comp. Methods Programs Biomed. 187:105099","journal-title":"Comp. Methods Programs Biomed."},{"issue":"6","key":"3418_CR8","first-page":"1025","volume":"18","author":"Z Yang","year":"2023","unstructured":"Yang Z, Simon R, Linte CA (2023) Learning feature descriptors for pre-and intra-operative point cloud matching for laparoscopic liver registration. IJCARS 18(6):1025\u20131032","journal-title":"IJCARS"},{"key":"3418_CR9","doi-asserted-by":"crossref","unstructured":"Zhang Y, Zou Y, Liu PX (2024) Point cloud registration in laparoscopic liver surgery using keypoint correspondence registration network. IEEE TMI","DOI":"10.1109\/TMI.2024.3457228"},{"key":"3418_CR10","doi-asserted-by":"crossref","unstructured":"Koo B, \u00d6zg\u00fcr E, Le Roy B, Buc E, Bartoli A (2017) Deformable registration of a preoperative 3d liver volume to a laparoscopy image using contour and shading cues. In: Proceedings of MICCAI, pp. 326\u2013334. Springer","DOI":"10.1007\/978-3-319-66182-7_38"},{"issue":"12","key":"3418_CR11","first-page":"2211","volume":"17","author":"Y Espinel","year":"2022","unstructured":"Espinel Y, Calvet L, Botros K, Buc E, Tilmant C, Bartoli A (2022) Using multiple images and contours for deformable 3d\u20132d registration of a preoperative ct in laparoscopic liver surgery. IJCARS 17(12):2211\u20132219","journal-title":"IJCARS"},{"key":"3418_CR12","doi-asserted-by":"crossref","unstructured":"Koo B, Robu MR, Allam M, Pfeiffer M, Thompson S, Gurusamy K, Davidson B, Speidel S, Hawkes D, Stoyanov D, et al. (2022) Automatic, global registration in laparoscopic liver surgery. IJCARS, 1\u201310","DOI":"10.1007\/s11548-021-02518-7"},{"issue":"8","key":"3418_CR13","first-page":"1429","volume":"17","author":"M Labrunie","year":"2022","unstructured":"Labrunie M, Ribeiro M, Mourthadhoi F, Tilmant C, Le Roy B, Buc E, Bartoli A (2022) Automatic preoperative 3d model registration in laparoscopic liver resection. IJCARS 17(8):1429\u20131436","journal-title":"IJCARS"},{"key":"3418_CR14","unstructured":"Labrunie M, Pizarro D, Tilmant C, Bartoli A (2023) Automatic 3d\/2d deformable registration in minimally invasive liver resection using a mesh recovery network. In: MIDL, pp. 1104\u20131123"},{"key":"3418_CR15","doi-asserted-by":"crossref","unstructured":"Mhiri I, Pizarro D, Bartoli A (2024) Neural patient-specific 3d\u20132d registration in laparoscopic liver resection. IJCARS, 1\u20138","DOI":"10.1007\/s11548-024-03231-x"},{"issue":"1","key":"3418_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1145\/3532624","volume":"17","author":"X Luo","year":"2023","unstructured":"Luo X, Wang H, Wu D, Chen C, Deng M, Huang J, Hua X-S (2023) A survey on deep hashing methods. ACM Trans. Knowl. Discovery Data 17(1):1\u201350","journal-title":"ACM Trans. Knowl. Discovery Data"},{"issue":"8","key":"3418_CR17","first-page":"1461","volume":"17","author":"J Ramalhinho","year":"2022","unstructured":"Ramalhinho J, Koo B, Monta\u00f1a-Brown N, Saeed SU, Bonmati E, Gurusamy K, Pereira SP, Davidson B, Hu Y, Clarkson MJ (2022) Deep hashing for global registration of untracked 2d laparoscopic ultrasound to ct. IJCARS 17(8):1461\u20131468","journal-title":"IJCARS"},{"key":"3418_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2021.101981","volume":"69","author":"J Fang","year":"2021","unstructured":"Fang J, Fu H, Liu J (2021) Deep triplet hashing network for case-based medical image retrieval. Med. Imag. Anal. 69:101981","journal-title":"Med. Imag. Anal."},{"key":"3418_CR19","doi-asserted-by":"crossref","unstructured":"Numata S, Koeda M, Onishi K, Watanabe K, Noborio H (2020) A hashing algorithm of depth image matching for liver surgery. In: Human-Computer Interaction. Design and User Experience: Thematic Area, HCI 2020, Held as Part of the 22nd International Conference, HCII 2020, Copenhagen, Denmark, July 19\u201324, 2020, Proceedings, Part I 22, pp. 625\u2013634. Springer","DOI":"10.1007\/978-3-030-49059-1_46"},{"key":"3418_CR20","first-page":"1075","volume":"15","author":"S Thompson","year":"2020","unstructured":"Thompson S, Dowrick T, Ahmad M, Xiao G, Koo B, Bonmati E, Kahl K, Clarkson MJ (2020) Scikit-surgery: compact libraries for surgical navigation. IJCARS 15:1075\u20131084","journal-title":"IJCARS"},{"issue":"5","key":"3418_CR21","doi-asserted-by":"publisher","first-page":"2695","DOI":"10.1002\/mp.16310","volume":"50","author":"T Dowrick","year":"2023","unstructured":"Dowrick T, Xiao G, Nikitichev D, Dursun E, Berkel N, Allam M, Koo B, Ramalhinho J, Thompson S, Gurusamy K (2023) Evaluation of a calibration rig for stereo laparoscopes. Med. Phys. 50(5):2695\u20132704","journal-title":"Med. Phys."},{"key":"3418_CR22","doi-asserted-by":"crossref","unstructured":"Pei J, Cui R, Li Y, Si W, Qin J, Heng P-A (2024) Depth-driven geometric prompt learning for laparoscopic liver landmark detection. In: Proceedings of MICCAI, pp. 154\u2013164. Springer","DOI":"10.1007\/978-3-031-72089-5_15"}],"updated-by":[{"DOI":"10.1007\/s11548-025-03488-w","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2025,8,31]],"date-time":"2025-08-31T00:00:00Z","timestamp":1756598400000}}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03418-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-025-03418-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03418-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,6]],"date-time":"2025-09-06T15:18:26Z","timestamp":1757171906000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-025-03418-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,23]]},"references-count":22,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2025,7]]}},"alternative-id":["3418"],"URL":"https:\/\/doi.org\/10.1007\/s11548-025-03418-w","relation":{"correction":[{"id-type":"doi","id":"10.1007\/s11548-025-03488-w","asserted-by":"object"}]},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,23]]},"assertion":[{"value":"11 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 August 2025","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The sixth sentence under the section \u201cPose generation and rendering\" has been updated","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 August 2025","order":7,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":8,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":9,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1007\/s11548-025-03488-w","URL":"https:\/\/doi.org\/10.1007\/s11548-025-03488-w","order":10,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All data involving human participants was acquired in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards, under the study \u201cREC=14\/LO\/1264, IRAS=158321\u201d.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}