{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T07:52:12Z","timestamp":1791618732730,"version":"4.3.4"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2025,8,30]],"date-time":"2025-08-30T00:00:00Z","timestamp":1756512000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,30]],"date-time":"2025-08-30T00:00:00Z","timestamp":1756512000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002839","name":"Charit\u00e9 - Universit\u00e4tsmedizin Berlin","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100002839","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Strain quantifies myocardial deformation. Despite its high diagnostic value, strain analyses using cardiovascular magnetic resonance (CMR) feature tracking (FT) have not been fully implemented into clinical routine due to lack of information on reproducibility. The purpose of this study was to assess the comparability of cardiovascular magnetic resonance CMR FT strain and ejection fraction (EF) measurements, obtained from different MR scanners and analyzed using different software platforms.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>CMR examinations were performed in 15 healthy volunteers using three different scanners (German Heart Center of the Charit\u00e9, Charit\u00e9 Campus Berlin Buch, and Theresien-Hospital Mannheim). FT was performed using Medis Suite and Circle CVI. Inter-software\/scanner agreement was determined using Bland\u2013Altman plots, Wilcoxon test, and paired Student\u2019s t test. Intra-\/inter-observer reproducibility was evaluated using intraclass correlation coefficients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Left ventricular (LV) global longitudinal (GLS) and circumferential (GCS) strain did not differ between the three centers (small bias of \u2212\u20091.27 to 1.32% for GLS and 0.91 to 0.69% for GCS). Inter-scanner agreement was lower regarding LV global radial strain (GRS) (bias of \u2212\u20092.29 to 4.53%) and good for LV EF (bias of \u2212\u20090.59 to 0.94%). Inter-software agreement was low for GLS (bias of \u2212\u20095.72 to \u2212\u20094.59%), GCS (\u2212\u20091.13 to \u2212\u20091.55%), and GRS (18.34 to 19.83%), with higher GLS\/GCS and lower GRS values in CVI than Medis. LV EF showed better inter-software agreement (biases of \u2212\u20090.07 to 0.06%). Intra- and inter-observer reproducibility was good for strain measurements across all scanners (bias of \u2212\u20090.01 to 2.05 and 0.22 to 1.92, respectively) and software packages (ICC 0.70 to 0.90 and 0.51 to 0.89, respectively).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Inter-scanner reproducibility for CMR FT measurements was high for GLS and GCS, suggesting potential use in routine CMR examinations. However, strain values between the two software vendors (CVI and Medis) were significantly different, indicating the need for standardization and implementation of software-specific cutoff values.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11548-025-03499-7","type":"journal-article","created":{"date-parts":[[2025,8,30]],"date-time":"2025-08-30T08:05:57Z","timestamp":1756541157000},"page":"319-331","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["A multicenter study on the comparability of myocardial strain values acquired with different CMR scanners and analyzed with different post-processing software: insights into the \u201cTraveling Volunteers\u201d study"],"prefix":"10.1007","volume":"21","author":[{"given":"Collin","family":"Goetze","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wensu","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Doeblin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aylin","family":"Demir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephanie","family":"Wiesemann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jochen","family":"Hansmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Volkmar","family":"Falk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeanette","family":"Schulz-Menger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4855-7698","authenticated-orcid":false,"given":"Jennifer","family":"Erley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Kelle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,30]]},"reference":[{"key":"3499_CR1","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1111\/echo.13878","volume":"35","author":"RM Inciardi","year":"2018","unstructured":"Inciardi RM, Galderisi M, Nistri S, Santoro C, Cicoira M, Rossi A (2018) Echocardiographic advances in hypertrophic cardiomyopathy: three-dimensional and strain imaging echocardiography. Echocardiography 35:716\u2013726. https:\/\/doi.org\/10.1111\/echo.13878","journal-title":"Echocardiography"},{"key":"3499_CR2","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1001\/jamacardio.2019.0052","volume":"4","author":"TH Marwick","year":"2019","unstructured":"Marwick TH, Shah SJ, Thomas JD (2019) Myocardial strain in the assessment of patients with heart failure: a review. JAMA Cardiol 4:287\u2013294","journal-title":"JAMA Cardiol"},{"key":"3499_CR3","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/s12968-020-00610-6","volume":"22","author":"J Schulz-Menger","year":"2020","unstructured":"Schulz-Menger J, Bluemke DA, Bremerich J, Flamm SD, Fogel MA, Friedrich MG, Kim RJ, von Knobelsdorff-Brenkenhoff F, Kramer CM, Pennell DJ, Plein S, Nagel E (2020) Standardized image interpretation and post-processing in cardiovascular magnetic resonance\u20142020 update. J Cardiovasc Magn Reson 22:19. https:\/\/doi.org\/10.1186\/s12968-020-00610-6","journal-title":"J Cardiovasc Magn Reson"},{"key":"3499_CR4","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1002\/jmri.21612","volume":"29","author":"M Neizel","year":"2009","unstructured":"Neizel M, Lossnitzer D, Korosoglou G, Sch\u00e4ufele T, Lewien A, Steen H, Katus HA, Osman NF, Giannitsis E (2009) Strain-encoded (SENC) magnetic resonance imaging to evaluate regional heterogeneity of myocardial strain in healthy volunteers: comparison with conventional tagging. J Magn Reson Imaging 29:99\u2013105. https:\/\/doi.org\/10.1002\/jmri.21612","journal-title":"J Magn Reson Imaging"},{"key":"3499_CR5","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1006\/jmre.1998.1676","volume":"137","author":"AH Aletras","year":"1999","unstructured":"Aletras AH, Ding S, Balaban RS, Wen H (1999) DENSE: displacement encoding with stimulated echoes in cardiac functional MRI. J Magn Reson 137:247\u2013252. https:\/\/doi.org\/10.1006\/jmre.1998.1676","journal-title":"J Magn Reson"},{"key":"3499_CR6","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s12968-018-0448-9","volume":"20","author":"JJ Cao","year":"2018","unstructured":"Cao JJ, Ngai N, Duncanson L, Cheng J, Gliganic K, Chen Q (2018) A comparison of both DENSE and feature tracking techniques with tagging for the cardiovascular magnetic resonance assessment of myocardial strain. J Cardiovasc Magn Reson 20:26. https:\/\/doi.org\/10.1186\/s12968-018-0448-9","journal-title":"J Cardiovasc Magn Reson"},{"key":"3499_CR7","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1007\/s10741-017-9621-8","volume":"22","author":"A Scatteia","year":"2017","unstructured":"Scatteia A, Baritussio A, Bucciarelli-Ducci C (2017) Strain imaging using cardiac magnetic resonance. Heart Fail Rev 22:465\u2013476. https:\/\/doi.org\/10.1007\/s10741-017-9621-8","journal-title":"Heart Fail Rev"},{"key":"3499_CR8","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1093\/ehjci\/jez041","volume":"20","author":"MS Amzulescu","year":"2019","unstructured":"Amzulescu MS, De Craene M, Langet H, Pasquet A, Vancraeynest D, Pouleur AC, Vanoverschelde JL, Gerber BL (2019) Myocardial strain imaging: review of general principles, validation, and sources of discrepancies. Eur Heart J Cardiovasc Imaging 20:605\u2013619. https:\/\/doi.org\/10.1093\/ehjci\/jez041","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"3499_CR9","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.1016\/j.echo.2015.06.011","volume":"28","author":"KE Farsalinos","year":"2015","unstructured":"Farsalinos KE, Daraban AM, \u00dcnl\u00fc S, Thomas JD, Badano LP, Voigt J-U (2015) Head-to-head comparison of global longitudinal strain measurements among nine different vendors. J Am Soc Echocardiogr 28:1171-1181.e2. https:\/\/doi.org\/10.1016\/j.echo.2015.06.011","journal-title":"J Am Soc Echocardiogr"},{"key":"3499_CR10","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1016\/j.jacc.2016.12.012","volume":"69","author":"P Collier","year":"2017","unstructured":"Collier P, Phelan D, Klein A (2017) A test in context: myocardial strain measured by speckle-tracking echocardiography. J Am Coll Cardiol 69:1043\u20131056","journal-title":"J Am Coll Cardiol"},{"key":"3499_CR11","doi-asserted-by":"publisher","first-page":"6846","DOI":"10.1007\/s00330-019-06315-4","volume":"29","author":"M Dobrovie","year":"2019","unstructured":"Dobrovie M, Barreiro-P\u00e9rez M, Curione D, Symons R, Claus P, Voigt JU, Bogaert J (2019) Inter-vendor reproducibility and accuracy of segmental left ventricular strain measurements using CMR feature tracking. Eur Radiol 29:6846\u20136857. https:\/\/doi.org\/10.1007\/s00330-019-06315-4","journal-title":"Eur Radiol"},{"key":"3499_CR12","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1186\/s12872-019-1031-5","volume":"19","author":"T Lapinskas","year":"2019","unstructured":"Lapinskas T, Zieschang V, Erley J, Stoiber L, Schnackenburg B, Stehning C, Gebker R, Patel AR, Kawaji K, Steen H, Zaliunas R, Backhaus SJ, Schuster A, Makowski M, Giusca S, Korosoglou G, Pieske B, Kelle S (2019) Strain-encoded cardiac magnetic resonance imaging: a new approach for fast estimation of left ventricular function. BMC Cardiovasc Disord 19:52. https:\/\/doi.org\/10.1186\/s12872-019-1031-5","journal-title":"BMC Cardiovasc Disord"},{"key":"3499_CR13","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1136\/hrt.2007.125039","volume":"94","author":"T Dill","year":"2008","unstructured":"Dill T (2008) Contraindications to magnetic resonance imaging. Heart 94:943\u2013948. https:\/\/doi.org\/10.1136\/hrt.2007.125039","journal-title":"Heart"},{"key":"3499_CR14","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.27804","author":"A Demir","year":"2022","unstructured":"Demir A, Wiesemann S, Erley J, Schmitter S, Trauzeddel RF, Pieske B, Hansmann J, Kelle S, Schulz-Menger J (2022) Traveling volunteers: a multi-vendor, multi-center study on reproducibility and comparability of 4D flow derived aortic hemodynamics in cardiovascular magnetic resonance. J Magn Reson Imaging. https:\/\/doi.org\/10.1002\/jmri.27804","journal-title":"J Magn Reson Imaging"},{"key":"3499_CR15","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1007\/s10554-020-01775-y","volume":"36","author":"J Erley","year":"2020","unstructured":"Erley J, Zieschang V, Lapinskas T, Demir A, Wiesemann S, Haass M, Osman NF, Simonetti OP, Liu Y, Patel AR, Mor-Avi V, Unal O, Johnson KM, Pieske B, Hansmann J, Schulz-Menger J, Kelle S (2020) A multi-vendor, multi-center study on reproducibility and comparability of fast strain-encoded cardiovascular magnetic resonance imaging. Int J Cardiovasc Imaging 36:899\u2013911. https:\/\/doi.org\/10.1007\/s10554-020-01775-y","journal-title":"Int J Cardiovasc Imaging"},{"key":"3499_CR16","doi-asserted-by":"publisher","DOI":"10.1016\/J.JOCMR.2024.101081","volume":"26","author":"C Manini","year":"2024","unstructured":"Manini C, H\u00fcllebrand M, Walczak L, Nordmeyer S, Jarmatz L, Kuehne T, Stern H, Meierhofer C, Harloff A, Erley J, Kelle S, Bannas P, Trauzeddel RF, Schulz-Menger J, Hennemuth A (2024) Impact of training data composition on the generalizability of convolutional neural network aortic cross-section segmentation in four-dimensional magnetic resonance flow imaging. J Cardiovasc Magn Reson 26:101081. https:\/\/doi.org\/10.1016\/J.JOCMR.2024.101081","journal-title":"J Cardiovasc Magn Reson"},{"key":"3499_CR17","doi-asserted-by":"publisher","first-page":"14100","DOI":"10.1038\/s41598-018-32226-3","volume":"8","author":"S Giusca","year":"2018","unstructured":"Giusca S, Korosoglou G, Zieschang V, Stoiber L, Schnackenburg B, Stehning C, Gebker R, Pieske B, Schuster A, Backhaus S, Pieske-Kraigher E, Patel A, Kawaji K, Steen H, Lapinskas T, Kelle S (2018) Reproducibility study on myocardial strain assessment using fast-SENC cardiac magnetic resonance imaging. Sci Rep 8:14100. https:\/\/doi.org\/10.1038\/s41598-018-32226-3","journal-title":"Sci Rep"},{"key":"3499_CR18","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1148\/radiology.208.2.9680575","volume":"208","author":"K Oppo","year":"1998","unstructured":"Oppo K, Leen E, Angerson WJ, Cooke TG, McArdle CS (1998) Doppler perfusion index: an interobserver and intraobserver reproducibility study. Radiology 208:453\u2013457. https:\/\/doi.org\/10.1148\/radiology.208.2.9680575","journal-title":"Radiology"},{"key":"3499_CR19","doi-asserted-by":"publisher","first-page":"3962","DOI":"10.1007\/s00330-020-07539-5","volume":"31","author":"C Lim","year":"2021","unstructured":"Lim C, Blaszczyk E, Riazy L, Wiesemann S, Sch\u00fcler J, von Knobelsdorff-Brenkenhoff F, Schulz-Menger J (2021) Quantification of myocardial strain assessed by cardiovascular magnetic resonance feature tracking in healthy subjects\u2014influence of segmentation and analysis software. Eur Radiol 31:3962\u20133972. https:\/\/doi.org\/10.1007\/s00330-020-07539-5","journal-title":"Eur Radiol"},{"key":"3499_CR20","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1186\/s12968-021-00742-3","volume":"23","author":"S Militaru","year":"2021","unstructured":"Militaru S, Panovsky R, Hanet V, Amzulescu MS, Langet H, Pisciotti MM, Pouleur A-C, Vanoverschelde J-LJ, Gerber BL (2021) Multivendor comparison of global and regional 2D cardiovascular magnetic resonance feature tracking strains vs tissue tagging at 3T. J Cardiovasc Magn Reson 23:54. https:\/\/doi.org\/10.1186\/s12968-021-00742-3","journal-title":"J Cardiovasc Magn Reson"},{"key":"3499_CR21","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1186\/s12933-022-01471-2","volume":"21","author":"L-T Shen","year":"2022","unstructured":"Shen L-T, Jiang L, Zhu Y-W, Shen M-T, Huang S, Shi R, Li Y, Yang Z-G (2022) Additive effect of aortic regurgitation degree on left ventricular strain in patients with type 2 diabetes mellitus evaluated via cardiac magnetic resonance tissue tracking. Cardiovasc Diabetol 21:37. https:\/\/doi.org\/10.1186\/s12933-022-01471-2","journal-title":"Cardiovasc Diabetol"},{"key":"3499_CR22","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1186\/s12968-017-0413-z","volume":"19","author":"J Cai","year":"2017","unstructured":"Cai J, Bryant JA, Le T-T, Su B, de Marvao A, O\u2019Regan DP, Cook SA, Chin CW-L (2017) Fractal analysis of left ventricular trabeculations is associated with impaired myocardial deformation in healthy Chinese. J Cardiovasc Magn Reson 19:102. https:\/\/doi.org\/10.1186\/s12968-017-0413-z","journal-title":"J Cardiovasc Magn Reson"},{"key":"3499_CR23","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1016\/j.jcmg.2023.05.019","volume":"17","author":"W Yang","year":"2024","unstructured":"Yang W, Xu J, Zhu L, Zhang Q, Wang Y, Zhao S, Lu M (2024) Myocardial strain measurements derived from MR feature-tracking: influence of sex, age, field strength, and vendor. JACC Cardiovasc Imaging 17:364\u2013379","journal-title":"JACC Cardiovasc Imaging"},{"key":"3499_CR24","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0210127","author":"SJ Backhaus","year":"2019","unstructured":"Backhaus SJ, Metschies G, Billing M, Kowallick JT, Gertz RJ, Lapinskas T, Pieske B, Lotz J, Bigalke B, Kutty S, Hasenfu\u00df G, Beerbaum P, Kelle S, Schuster A (2019) Cardiovascular magnetic resonance imaging feature tracking: impact of training on observer performance and reproducibility. PLoS ONE. https:\/\/doi.org\/10.1371\/journal.pone.0210127","journal-title":"PLoS ONE"},{"key":"3499_CR25","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2016.12.025","author":"HQ Vo","year":"2018","unstructured":"Vo HQ, Marwick TH, Negishi K (2018) MRI-derived myocardial strain measures in normal subjects. JACC Cardiovasc Imaging. https:\/\/doi.org\/10.1016\/j.jcmg.2016.12.025","journal-title":"JACC Cardiovasc Imaging"},{"key":"3499_CR26","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1093\/ehjci\/jes184","volume":"14","author":"LP Badano","year":"2013","unstructured":"Badano LP, Cucchini U, Muraru D, Al Nono O, Sarais C, Iliceto S (2013) Use of three-dimensional speckle tracking to assess left ventricular myocardial mechanics: inter-vendor consistency and reproducibility of strain measurements. Eur Heart J Cardiovasc Imaging 14:285\u2013293. https:\/\/doi.org\/10.1093\/ehjci\/jes184","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"3499_CR27","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1002\/jmri.25894","volume":"47","author":"AM Maceira","year":"2018","unstructured":"Maceira AM, Tuset-Sanchis L, L\u00f3pez-Garrido M, San Andres M, L\u00f3pez-Lereu MP, Monmeneu JV, Garc\u00eda-Gonz\u00e1lez MP, Higueras L (2018) Feasibility and reproducibility of feature-tracking-based strain and strain rate measures of the left ventricle in different diseases and genders. J Magn Reson Imaging 47:1415\u20131425. https:\/\/doi.org\/10.1002\/jmri.25894","journal-title":"J Magn Reson Imaging"},{"key":"3499_CR28","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1186\/1532-429x-15-37","volume":"15","author":"S Donekal","year":"2013","unstructured":"Donekal S, Ambale-Venkatesh B, Berkowitz S, Wu CO, Choi EY, Fernandes V, Yan R, Harouni AA, Bluemke DA, Lima JAC (2013) Inter-study reproducibility of cardiovascular magnetic resonance tagging. J Cardiovasc Magn Reson 15:37. https:\/\/doi.org\/10.1186\/1532-429x-15-37","journal-title":"J Cardiovasc Magn Reson"},{"issue":"2","key":"3499_CR29","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1002\/ehf2.12576","volume":"7","author":"P Bucius","year":"2020","unstructured":"Bucius P, Erley J, Tanacli R, Zieschang V, Giusca S, Korosoglou G, Steen H, Stehning C, Pieske B, Pieske-Kraigher E, Schuster A, Lapinskas T, Kelle S (2020) Comparison of feature tracking, fast-SENC, and myocardial tagging for global and segmental left ventricular strain. ESC Heart Failure 7(2):523\u2013532. https:\/\/doi.org\/10.1002\/ehf2.12576","journal-title":"ESC Heart Failure"},{"key":"3499_CR30","doi-asserted-by":"publisher","DOI":"10.1093\/ehjimp\/qyae093","author":"UE Witt","year":"2024","unstructured":"Witt UE, M\u00fcller ML, Beyer RE, Wieditz J, Salem S, Hashemi D, Chen W, Cvetkovic M, Nolden AC, Doeblin P, Blum M, Thiede G, Huppertz A, Steen H, Remppis BA, Falk V, Friede T, Kelle S (2024) A simplified approach to discriminate between healthy subjects and patients with heart failure using cardiac magnetic resonance myocardial deformation imaging. Eur Heart J. https:\/\/doi.org\/10.1093\/ehjimp\/qyae093","journal-title":"Eur Heart J"},{"key":"3499_CR31","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehae666.042","author":"AE Balinisteanu","year":"2024","unstructured":"Balinisteanu AE, Duchenne J, Puvrez A, Wouters L, Bezy S, Youssef A, De Groef K, Van Langenhoven L, Papangelopoulou K, Cieplucha A, Cattapan I, Tostes P, Vinereanu D, Voigt JU (2024) Inter-vendor differences in speckle tracking strain\u2014a ten year follow-up on the strain standardization task force inter-vendor comparison study. Eur Heart J. https:\/\/doi.org\/10.1093\/eurheartj\/ehae666.042","journal-title":"Eur Heart J"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03499-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-025-03499-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03499-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T18:02:47Z","timestamp":1774375367000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-025-03499-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,30]]},"references-count":31,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["3499"],"URL":"https:\/\/doi.org\/10.1007\/s11548-025-03499-7","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,30]]},"assertion":[{"value":"12 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"There are no conflict of interest. The study was approved by the Ethics Committee of the Charite\u0301-University-Medicine in Berlin and complied with the Declaration of Helsinki. All study subjects provided written informed consent.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}