{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T20:58:41Z","timestamp":1771880321015,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T00:00:00Z","timestamp":1757721600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T00:00:00Z","timestamp":1757721600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003483","name":"Hebrew University of Jerusalem","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100003483","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Manual detection and measurement of structures in volumetric scans is routine in clinical practice but is time-consuming and subject to observer variability. Automatic deep learning-based solutions are effective but require a large dataset of manual annotations by experts. We present a novel annotation-efficient semi-supervised deep learning method for automatic detection, segmentation, and measurement of the short axis length (SAL) of mediastinal lymph nodes (LNs) in contrast-enhanced CT (ceCT) scans.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Our semi-supervised method combines the precision of expert annotations with the quantity advantages of pseudolabeled data. It uses an ensemble of 3D nnU-Net models trained on a few expert-annotated scans to generate pseudolabels on a large dataset of unannotated scans. The pseudolabels are then filtered to remove false positive LNs by excluding LNs outside the mediastinum and LNs overlapping with other anatomical structures. Finally, a single 3D nnU-Net model is trained using the filtered pseudo-labels. Our method optimizes the ratio of annotated\/non-annotated dataset sizes to achieve the desired performance, thus reducing manual annotation effort.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Experimental studies on three chest ceCT datasets with a total of 268 annotated scans (1817 LNs), of which 134 scans were used for testing and the remaining for ensemble training in batches of 17, 34, 67, and 134 scans, as well as 710 unannotated scans, show that the semi-supervised models\u2019 recall improvements were 11\u201324% (0.72\u20130.87) while maintaining comparable precision levels. The best model achieved mean SAL differences of 1.65\u2009\u00b1\u20090.92\u00a0mm for normal LNs and 4.25\u2009\u00b1\u20094.98\u00a0mm for enlarged LNs, both within the observer variability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Our semi-supervised method requires one-fourth to one-eighth less annotations to achieve a performance to supervised models trained on the same dataset for the automatic measurement of mediastinal LNs in chest ceCT. Using pseudolabels with anatomical filtering may be effective to overcome the challenges of the development of AI-based solutions in radiology.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11548-025-03513-y","type":"journal-article","created":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T03:43:51Z","timestamp":1757735031000},"page":"103-113","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Annotation-efficient deep learning detection and measurement of mediastinal lymph nodes in CT"],"prefix":"10.1007","volume":"21","author":[{"given":"Alon","family":"Olesinski","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard","family":"Lederman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yusef","family":"Azraq","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacob","family":"Sosna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3010-4770","authenticated-orcid":false,"given":"Leo","family":"Joskowicz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,9,13]]},"reference":[{"key":"3513_CR1","volume-title":"Medical image computing and computer-assisted intervention. Lecture notes in computer science 9351","author":"O Ronneberger","year":"2015","unstructured":"Ronneberger O, Fischer P, Brox T (2015) U-Net: convolutional networks for biomedical image segmentation. In: Navab N, Hornegger J, Wells W, Frangi A (eds) Medical image computing and computer-assisted intervention. Lecture notes in computer science 9351. Springer, Cham"},{"issue":"2","key":"3513_CR2","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1038\/s41592-020-01008-z","volume":"18","author":"F Isensee","year":"2021","unstructured":"Isensee F, Jaeger PF, Kohl SA, Petersen J, Maier-Hein KH (2021) nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation. Nat Methods 18(2):203\u2013211","journal-title":"Nat Methods"},{"issue":"12","key":"3513_CR3","doi-asserted-by":"publisher","first-page":"10076","DOI":"10.1109\/TPAMI.2024.3435571","volume":"46","author":"R Azad","year":"2024","unstructured":"Azad R, Aghdam EK, Rauland A, Jia Y, Haddadi A (2024) Medical image segmentation review: the success of U-net. IEEE Trans Pattern Anal Mach Intell 46(12):10076\u201310095","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"3513_CR4","doi-asserted-by":"publisher","DOI":"10.1148\/ryai.230024","author":"J Wasserthal","year":"2023","unstructured":"Wasserthal J, Breit HC, Meyer MT, Pradella M, Hinck D, Sauter AW, Heye T, Boll DT, Cyriac J, Yang S, Bach M (2023) TotalSegmentator: robust segmentation of 104 anatomic structures in CT images. Radiol Artif Intell. https:\/\/doi.org\/10.1148\/ryai.230024","journal-title":"Radiol Artif Intell"},{"key":"3513_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2024.103268","volume":"97","author":"B Di Veroli","year":"2024","unstructured":"Di Veroli B, Lederman R, Shoshan Y, Sosna J, Joskowicz L (2024) A graph-theoretic approach for the analysis of lesion changes and lesions detection review in longitudinal oncological imaging. Med Image Anal 97:103268","journal-title":"Med Image Anal"},{"issue":"3","key":"3513_CR6","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1007\/s11060-024-04580-y","volume":"166","author":"Y Hammer","year":"2024","unstructured":"Hammer Y, Najjar W, Kahanov L, Shoshan Y, Joskowicz L (2024) Two is better than one: longitudinal detection and volumetric evaluation of brain metastases after stereotactic radiosurgery with a deep learning pipeline. J Neuro-Oncol 166(3):547\u2013555","journal-title":"J Neuro-Oncol"},{"issue":"2","key":"3513_CR7","first-page":"e0808","volume":"40","author":"N Kenneth","year":"2025","unstructured":"Kenneth N, Rochman S, Lederman R, Sosna J, Joskowicz L (2025) Metastatic lung lesion changes in follow-up chest CT: the advantage of simultaneous analysis with SimU-Net. J Thorac Imaging 40(2):e0808","journal-title":"J Thorac Imaging"},{"key":"3513_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2022.102675","volume":"83","author":"A Szeskin","year":"2023","unstructured":"Szeskin A, Rochman S, Lederman R, Sosna J, Joskowicz L (2023) Liver lesion changes analysis in longitudinal CECT scans by simultaneous deep learning voxel classification with SimU-Net. Med Image Anal 83:102675","journal-title":"Med Image Anal"},{"issue":"6","key":"3513_CR9","doi-asserted-by":"publisher","first-page":"1718","DOI":"10.1378\/chest.111.6.1718","volume":"111","author":"CF Mountain","year":"1997","unstructured":"Mountain CF, Dresler CM (1997) Regional lymph node classification for lung cancer staging. Chest 111(6):1718\u20131723","journal-title":"Chest"},{"key":"3513_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s40134-013-0036-6","volume":"2","author":"Y Mao","year":"2014","unstructured":"Mao Y, Hedgire S, Harisinghani M (2014) Radiologic assessment of lymph nodes in oncologic patients. Curr Radiol Rep 2:1\u20133","journal-title":"Curr Radiol Rep"},{"issue":"2","key":"3513_CR11","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/j.ejca.2008.10.028","volume":"45","author":"LH Schwartz","year":"2009","unstructured":"Schwartz LH, Bogaerts J, Ford R, Shankar L, Therasse P, Gwyther S, Eisenhauer EA (2009) Evaluation of lymph nodes with RECIST 1.1. Eur J Cancer 45(2):261\u2013327","journal-title":"Eur J Cancer"},{"key":"3513_CR12","doi-asserted-by":"crossref","unstructured":"Li S, Zhang C, He X (2020) Shape-aware semi-supervised 3D semantic segmentation for medical images. In: Proc. 23rd Int. Conf. Medical Image Computing and Computer Assisted Intervention, Part I-23. Springer, pp 552\u2013561","DOI":"10.1007\/978-3-030-59710-8_54"},{"key":"3513_CR13","doi-asserted-by":"crossref","unstructured":"Nie D, Gao Y, Wang L, Shen D (2018) ASDNet: Attention-based semi-supervised deep networks for medical image segmentation. In: Proc. 21st Conf. Medical image computing and computer assisted intervention Part IV-11. Springer, pp 370\u2013378","DOI":"10.1007\/978-3-030-00937-3_43"},{"key":"3513_CR14","doi-asserted-by":"crossref","unstructured":"Wu Y, Xu M, Ge Z, Cai J, Zhang L (2021) Semi-supervised left atrium segmentation with mutual consistency training. In: Proc. 24th Conf. medical image computing and computer assisted intervention, Part II. Springer, pp 297\u2013306","DOI":"10.1007\/978-3-030-87196-3_28"},{"key":"3513_CR15","doi-asserted-by":"crossref","unstructured":"Yu L, Wang S, Li X, Fu CW, Heng PA (2019) Uncertainty-aware self-ensembling model for semi-supervised 3D left atrium segmentation. In: Proc 22th Int. Conf. medical image computing and computer assisted intervention, Part II. Springer, pp 605\u2013613","DOI":"10.1007\/978-3-030-32245-8_67"},{"issue":"2","key":"3513_CR16","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1109\/TNNLS.2020.2995319","volume":"32","author":"X Li","year":"2020","unstructured":"Li X, Yu L, Chen H, Fu CW, Xing L, Heng PA (2020) Transformation-consistent self-ensembling model for semi-supervised medical image segmentation. IEEE Trans Neural Netw Learn Syst 32(2):523\u2013534","journal-title":"IEEE Trans Neural Netw Learn Syst"},{"key":"3513_CR17","doi-asserted-by":"crossref","unstructured":"Zhao X, Xie P, Wang M, Li W, Pickhardt PJ, Xia W, Xiong F, Zhang R, Xie Y, Jian J, Bai H (2020) Deep learning\u2013based fully automated detection and segmentation of lymph nodes on multiparametric MRI for rectal cancer: a multicenter study. EBioMedicine 1(56)","DOI":"10.1016\/j.ebiom.2020.102780"},{"issue":"13","key":"3513_CR18","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2023.1115258","volume":"16","author":"T Weissmann","year":"2023","unstructured":"Weissmann T, Huang Y, Fischer S, Roesch J, Mansoorian S, Ayala Gaona H, Gostian AO, Hecht M, Lettmaier S, Deloch L, Frey B (2023) Deep learning for automatic head and neck lymph node level delineation provides expert-level accuracy. Front Oncol 16(13):1115258","journal-title":"Front Oncol"},{"key":"3513_CR19","doi-asserted-by":"crossref","unstructured":"Oda H, Roth HR, Bhatia KK, Oda M, Kitasaka T, Iwano S, Homma H, Takabatake H, Mori M, Natori H, Schnabel JA (2018) Dense volumetric detection and segmentation of mediastinal lymph nodes in chest CT images. In: Proc. SPIE Conf. medical imaging: computer-aided diagnosis 10575:1057502","DOI":"10.1117\/12.2287066"},{"key":"3513_CR20","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1007\/s11548-019-01948-8","volume":"14","author":"D Bouget","year":"2019","unstructured":"Bouget D, J\u00f8rgensen A, Kiss G, Leira HO, Lang\u00f8 T (2019) Semantic segmentation and detection of mediastinal lymph nodes and anatomical structures in CT data for lung cancer staging. Int J Comput Assist Radiol Surg 14:977\u2013986","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3513_CR21","first-page":"1","volume":"13","author":"TS Mathai","year":"2024","unstructured":"Mathai TS, Liu B, Summers RM (2024) Segmentation of mediastinal lymph nodes in CT with anatomical priors. Int J Comput Assist Radiol Surg 13:1\u20138","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"4","key":"3513_CR22","doi-asserted-by":"publisher","first-page":"927","DOI":"10.2214\/ajr.170.4.9530036","volume":"170","author":"PN Cascade","year":"1998","unstructured":"Cascade PN, Gross BH, Kazerooni EA, Quint LE, Francis IR, Strawderman M, Korobkin M (1998) Variability in the detection of enlarged mediastinal lymph nodes in staging lung cancer: a comparison of contrast-enhanced and unenhanced CT. AJR Am J Roentgenol 170(4):927\u2013931","journal-title":"AJR Am J Roentgenol"},{"key":"3513_CR23","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1007\/s00247-004-1383-5","volume":"35","author":"S Andronikou","year":"2005","unstructured":"Andronikou S, Brauer B, Galpin J, Brachmeyer S, Lucas S, Joseph E, DuToit G, Swingler G (2005) Interobserver variability in the detection of mediastinal and hilar lymph nodes on CT in children with suspected pulmonary tuberculosis. Pediatr Radiol 35:425\u2013428","journal-title":"Pediatr Radiol"},{"issue":"2","key":"3513_CR24","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1148\/radiol.13122665","volume":"269","author":"A McErlean","year":"2013","unstructured":"McErlean A, Panicek DM, Zabor EC, Moskowitz CS, Bitar R, Motzer RJ, Hricak H, Ginsberg MS (2013) Intra-and interobserver variability in CT measurements in oncology. Radiology 269(2):451\u2013459","journal-title":"Radiology"},{"issue":"4","key":"3513_CR25","doi-asserted-by":"publisher","first-page":"851","DOI":"10.2214\/ajr.167.4.8819370","volume":"167","author":"KD Hopper","year":"1996","unstructured":"Hopper KD, Kasales CJ, Van Slyke MA, Schwartz TA, TenHave TR, Jozefiak JA (1996) Analysis of interobserver and intraobserver variability in CT tumor measurements. AJR Am J Roentgenol 167(4):851\u2013854","journal-title":"AJR Am J Roentgenol"},{"key":"3513_CR26","doi-asserted-by":"publisher","first-page":"1114","DOI":"10.1007\/s00330-008-0866-4","volume":"18","author":"M Fabel","year":"2008","unstructured":"Fabel M, von Tengg-Kobligk H, Giesel FL, Bornemann L, Dicken V, Kopp-Schneider A, Moser C, Delorme S, Kauczor HU (2008) Semi-automated volumetric analysis of lymph node metastases in patients with malignant melanoma stage III\/IV: a feasibility study. Eur Radiol 18:1114\u20131122","journal-title":"Eur Radiol"},{"key":"3513_CR27","doi-asserted-by":"crossref","unstructured":"Zhao Y, Yang C, Schweidtmann A, Tao Q (2022) Efficient Bayesian uncertainty estimation for nnU-Net. In: Proc. Int. Conf. on Medical Image computing and computer-assisted intervention Part III. Springer, pp 535\u2013544","DOI":"10.1007\/978-3-031-16452-1_51"},{"key":"3513_CR28","doi-asserted-by":"crossref","unstructured":"Roth HR, Lu L, Seff A, Cherry KM, Hoffman J, Wang S, Liu J, Turkbey E, Summers RM (2014) A new 2.5 D representation for lymph node detection using random sets of deep convolutional neural network observations. In: Proc. 17th Conf. medical image computing and computer-assisted intervention, Part I. Springer, pp 520\u2013527","DOI":"10.1007\/978-3-319-10404-1_65"},{"key":"3513_CR29","doi-asserted-by":"crossref","unstructured":"Dorent R, Khajavi R, Idris T, Ziegler E, Somarouthu B, Jacene H, LaCasce A, Deissler J, Ehrhardt J, Engelson S, Fischer SM (2024) LNQ 2023 challenge: Benchmark of weakly-supervised techniques for mediastinal lymph node quantification. arXiv preprint arXiv:2408.10069","DOI":"10.59275\/j.melba.2025-d482"},{"key":"3513_CR30","doi-asserted-by":"crossref","unstructured":"Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, Gerig G (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 1116\u201328","DOI":"10.1016\/j.neuroimage.2006.01.015"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03513-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-025-03513-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03513-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T20:02:48Z","timestamp":1771876968000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-025-03513-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,13]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,1]]}},"alternative-id":["3513"],"URL":"https:\/\/doi.org\/10.1007\/s11548-025-03513-y","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,13]]},"assertion":[{"value":"10 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"There was no need for informed consent.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}