{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T02:22:49Z","timestamp":1779416569148,"version":"3.53.1"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T00:00:00Z","timestamp":1767657600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T00:00:00Z","timestamp":1767657600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Think Surgical Inc"},{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"DOI":"10.1007\/s11548-025-03566-z","type":"journal-article","created":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T19:23:08Z","timestamp":1767727388000},"page":"827-836","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Statistical shape model-based estimation of registration error in computer-assisted total knee arthroplasty"],"prefix":"10.1007","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-4683-3374","authenticated-orcid":false,"given":"Behnaz","family":"Gheflati","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Morteza","family":"Mirzaei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joel","family":"Zuhars","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunil","family":"Rottoo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hassan","family":"Rivaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,6]]},"reference":[{"key":"3566_CR1","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.jbiomech.2019.07.003","volume":"93","author":"JT Lynch","year":"2019","unstructured":"Lynch JT, Schneider MT, Perriman DM, Scarvell JM, Pickering MR, Asikuzzaman M, Galvin CR, Besier TF, Smith PN (2019) Statistical shape modelling reveals large and distinct subchondral bony differences in osteoarthritic knees. J Biomech 93:177\u2013184. https:\/\/doi.org\/10.1016\/j.jbiomech.2019.07.003","journal-title":"J Biomech"},{"issue":"1","key":"3566_CR2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ocarto.2020.100032","volume":"2","author":"N-R Klem","year":"2020","unstructured":"Klem N-R, Kent P, Smith A, Dowsey M, Fary R, Sch\u00fctze R, O\u2019Sullivan P, Choong P, Bunzli S (2020) Satisfaction after total knee replacement for osteoarthritis is usually high, but what are we measuring? A systematic review. Osteoarthr Cartil Open 2(1):100032. https:\/\/doi.org\/10.1016\/j.ocarto.2020.100032","journal-title":"Osteoarthr Cartil Open"},{"key":"3566_CR3","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/acaae9","author":"X Fan","year":"2022","unstructured":"Fan X, Zhu Q, Tu P, Joskowicz L, Chen X (2022) A review of advances in image-guided orthopedic surgery. Phys Med Biol. https:\/\/doi.org\/10.1088\/1361-6560\/acaae9","journal-title":"Phys Med Biol"},{"issue":"2","key":"3566_CR4","doi-asserted-by":"publisher","first-page":"87","DOI":"10.5435\/jaaos-d-22-00596","volume":"31","author":"A Malyavko","year":"2023","unstructured":"Malyavko A, Cohen JS, Fuller SI, Agarwal AR, Golladay GJ, Thakkar SC (2023) Reduced early revision surgery and medical complications in computer-assisted knee arthroplasty compared with non-computer-assisted arthroplasty. JAAOS-J Am Acad Orthopa Surg 31(2):87\u201396. https:\/\/doi.org\/10.5435\/jaaos-d-22-00596","journal-title":"JAAOS-J Am Acad Orthopa Surg"},{"key":"3566_CR5","doi-asserted-by":"publisher","first-page":"3565","DOI":"10.1007\/s00167-016-4337-1","volume":"24","author":"F Picard","year":"2016","unstructured":"Picard F, Deep K, Jenny JY (2016) Current state of the art in total knee arthroplasty computer navigation. Knee Surg Sports Traumatol Arthrosc 24:3565\u20133574. https:\/\/doi.org\/10.1007\/s00167-016-4337-1","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"3","key":"3566_CR6","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1016\/j.media.2010.03.005","volume":"16","author":"P Markelj","year":"2012","unstructured":"Markelj P, Toma\u017eevi\u010d D, Likar B, Pernu\u0161 F (2012) A review of 3d\/2d registration methods for image-guided interventions. Med Image Anal 16(3):642\u2013661. https:\/\/doi.org\/10.1016\/j.media.2010.03.005","journal-title":"Med Image Anal"},{"key":"3566_CR7","unstructured":"Simon D, O\u2019toole R, Blackwell M, Morgan F, DiGioia A, Kanade T (1995) Accuracy validation in image-guided orthopaedic surgery. In: Proceedings of the 2nd international symposium on medical robotics and computer assisted surgery, vol 6. Citeseer, pp 185\u2013192"},{"key":"3566_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2025.02.061","author":"TD Luo","year":"2025","unstructured":"Luo TD, Martensson N, Howard JL, Stevens D, McIsaac KA, Lanting BA (2025) Identifying sources of error in computer-navigated total knee arthroplasty using sensitivity analyses in knee models. J Arthroplasty. https:\/\/doi.org\/10.1016\/j.arth.2025.02.061","journal-title":"J Arthroplasty"},{"issue":"4","key":"3566_CR9","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1016\/j.otsr.2013.12.029","volume":"100","author":"B Schlatterer","year":"2014","unstructured":"Schlatterer B, Linares J-M, Chabrand P, Sprauel J-M, Argenson J-N (2014) Influence of the optical system and anatomic points on computer-assisted total knee arthroplasty. Orthop Traumatol Surg Res 100(4):395\u2013402. https:\/\/doi.org\/10.1016\/j.otsr.2013.12.029","journal-title":"Orthop Traumatol Surg Res"},{"issue":"10","key":"3566_CR10","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1002\/jor.21139","volume":"28","author":"YS Brin","year":"2010","unstructured":"Brin YS, Livshetz I, Antoniou J, Greenberg-Dotan S, Zukor DJ (2010) Precise landmarking in computer assisted total knee arthroplasty is critical to final alignment. J Orthop Res 28(10):1355\u20131359. https:\/\/doi.org\/10.1002\/jor.21139","journal-title":"J Orthop Res"},{"issue":"5","key":"3566_CR11","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1016\/j.arth.2005.02.011","volume":"20","author":"W Yau","year":"2005","unstructured":"Yau W, Leung A, Chiu K, Tang W, Ng T (2005) Intraobserver errors in obtaining visually selected anatomic landmarks during registration process in nonimage-based navigation-assisted total knee arthroplasty: a cadaveric experiment. J Arthroplast 20(5):591\u2013601. https:\/\/doi.org\/10.1016\/j.arth.2005.02.011","journal-title":"J Arthroplast"},{"issue":"6","key":"3566_CR12","doi-asserted-by":"publisher","first-page":"938","DOI":"10.1016\/j.arth.2012.12.013","volume":"28","author":"DF Amanatullah","year":"2013","unstructured":"Amanatullah DF, Di Cesare PE, Meere PA, Pereira GC (2013) Identification of the landmark registration safe zones during total knee arthroplasty using an imageless navigation system. J Arthroplast 28(6):938\u2013942. https:\/\/doi.org\/10.1016\/j.arth.2012.12.013","journal-title":"J Arthroplast"},{"issue":"4","key":"3566_CR13","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1016\/j.arth.2013.06.034","volume":"29","author":"ET Davis","year":"2014","unstructured":"Davis ET, Pagkalos J, Gallie PA, Macgroarty K, Waddell JP, Schemitsch EH (2014) Defining the errors in the registration process during imageless computer navigation in total knee arthroplasty: a cadaveric study. J Arthroplast 29(4):698\u2013701. https:\/\/doi.org\/10.1016\/j.arth.2013.06.034","journal-title":"J Arthroplast"},{"issue":"1","key":"3566_CR14","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1006\/cviu.1995.1004","volume":"61","author":"TF Cootes","year":"1995","unstructured":"Cootes TF, Taylor CJ, Cooper DH, Graham J (1995) Active shape models-their training and application. Comput Vis Image Underst 61(1):38\u201359. https:\/\/doi.org\/10.1006\/cviu.1995.1004","journal-title":"Comput Vis Image Underst"},{"issue":"9","key":"3566_CR15","doi-asserted-by":"publisher","first-page":"2733","DOI":"10.1109\/tbme.2022.3152833","volume":"69","author":"A Boutillon","year":"2022","unstructured":"Boutillon A, Salhi A, Burdin V, Borotikar B (2022) Anatomically parameterized statistical shape model: explaining morphometry through statistical learning. IEEE Trans Biomed Eng 69(9):2733\u20132744. https:\/\/doi.org\/10.1109\/tbme.2022.3152833","journal-title":"IEEE Trans Biomed Eng"},{"key":"3566_CR16","doi-asserted-by":"crossref","unstructured":"Gheflati, B., Mirzaei, M., Rottoo, S., & Rivaz, H. (2025). Leveraging deep learning for nonlinear shape representation in anatomically parameterized statistical shape models. International Journal of Computer Assisted Radiology and Surgery, 1\u201312","DOI":"10.1007\/s11548-025-03330-3"},{"issue":"3","key":"3566_CR17","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.3390\/app12031020","volume":"12","author":"I Dupraz","year":"2022","unstructured":"Dupraz I, Bollinger A, Deckx J, Schierjott RA, Utz M, Jacobs M (2022) Using statistical shape models to optimize tka implant design. Appl Sci 12(3):1020. https:\/\/doi.org\/10.3390\/app12031020","journal-title":"Appl Sci"},{"issue":"6","key":"3566_CR18","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1016\/j.media.2011.04.001","volume":"15","author":"N Baka","year":"2011","unstructured":"Baka N, Kaptein BL, Bruijne M, Walsum T, Giphart J, Niessen WJ, Lelieveldt BP (2011) 2d\u20133d shape reconstruction of the distal femur from stereo x-ray imaging using statistical shape models. Med Image Anal 15(6):840\u2013850. https:\/\/doi.org\/10.1016\/j.media.2011.04.001","journal-title":"Med Image Anal"},{"issue":"2","key":"3566_CR19","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.media.2006.05.001","volume":"11","author":"KT Rajamani","year":"2007","unstructured":"Rajamani KT, Styner MA, Talib H, Zheng G, Nolte LP, Ballester MAG (2007) Statistical deformable bone models for robust 3d surface extrapolation from sparse data. Med Image Anal 11(2):99\u2013109. https:\/\/doi.org\/10.1016\/j.media.2006.05.001","journal-title":"Med Image Anal"},{"key":"3566_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.media.2017.09.004","volume":"43","author":"C Tycowicz","year":"2018","unstructured":"Tycowicz C, Ambellan F, Mukhopadhyay A, Zachow S (2018) An efficient Riemannian statistical shape model using differential coordinates: With application to the classification of data from the osteoarthritis initiative. Med Image Anal 43:1\u20139. https:\/\/doi.org\/10.1016\/j.media.2017.09.004","journal-title":"Med Image Anal"},{"key":"3566_CR21","doi-asserted-by":"publisher","first-page":"253","DOI":"10.3389\/fbioe.2020.00253","volume":"8","author":"P Cerveri","year":"2020","unstructured":"Cerveri P, Belfatto A, Manzotti A (2020) Predicting knee joint instability using a tibio-femoral statistical shape model. Front Bioeng Biotechnol 8:253. https:\/\/doi.org\/10.3389\/fbioe.2020.00253","journal-title":"Front Bioeng Biotechnol"},{"issue":"11","key":"3566_CR22","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.1109\/iccv.1999.791245","volume":"23","author":"Y Boykov","year":"2001","unstructured":"Boykov Y, Veksler O, Zabih R (2001) Fast approximate energy minimization via graph cuts. IEEE Trans Pattern Anal Mach Intell 23(11):1222\u20131239. https:\/\/doi.org\/10.1109\/iccv.1999.791245","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"3566_CR23","doi-asserted-by":"publisher","unstructured":"Fonov V, Evans AC, Botteron K, Almli CR, McKinstry RC, Collins DL, Group BDC, et al (2011) Unbiased average age-appropriate atlases for pediatric studies. Neuroimage 54(1):313\u2013327. https:\/\/doi.org\/10.1016\/j.neuroimage.2010.07.033","DOI":"10.1016\/j.neuroimage.2010.07.033"},{"issue":"5","key":"3566_CR24","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1016\/j.medengphy.2016.02.003","volume":"38","author":"J Zhang","year":"2016","unstructured":"Zhang J, Hislop-Jambrich J, Besier TF (2016) Predictive statistical models of baseline variations in 3-d femoral cortex morphology. Med Eng Phys 38(5):450\u2013457. https:\/\/doi.org\/10.1016\/j.medengphy.2016.02.003","journal-title":"Med Eng Phys"},{"issue":"9","key":"3566_CR25","doi-asserted-by":"publisher","first-page":"917","DOI":"10.1109\/42.952729","volume":"20","author":"JM Fitzpatrick","year":"2001","unstructured":"Fitzpatrick JM, West JB (2001) The distribution of target registration error in rigid-body point-based registration. IEEE Trans Med Imaging 20(9):917\u2013927. https:\/\/doi.org\/10.1109\/42.952729","journal-title":"IEEE Trans Med Imaging"},{"key":"3566_CR26","doi-asserted-by":"crossref","unstructured":"Besl PJ, McKay ND (1992) Method for registration of 3-d shapes. In: Sensor fusion IV: control paradigms and data structures, vol 1611. Spie, pp 586\u2013606","DOI":"10.1117\/12.57955"},{"issue":"2","key":"3566_CR27","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1007\/s11548-022-02720-1","volume":"18","author":"C Liu","year":"2023","unstructured":"Liu C, Song Y, Ma X, Sun T (2023) Accurate and robust registration method for computer-assisted high tibial osteotomy surgery. Int J Comput Assist Radiol Surg 18(2):329\u2013337. https:\/\/doi.org\/10.1007\/s11548-022-02720-1","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"3566_CR28","doi-asserted-by":"publisher","unstructured":"Granger S, Pennec X, Roche A (2001) Rigid point-surface registration using an em variant of icp for computer guided oral implantology. In: Medical image computing and computer-assisted intervention\u2014MICCAI 2001: 4th international conference Utrecht, The Netherlands, October 14\u201317, 2001 Proceedings, vol 4. Springer, pp 752\u2013761. https:\/\/doi.org\/10.1007\/3-540-45468-3_90","DOI":"10.1007\/3-540-45468-3_90"},{"issue":"14","key":"3566_CR29","doi-asserted-by":"publisher","first-page":"3177","DOI":"10.1016\/j.jbiomech.2016.07.040","volume":"49","author":"CK Fitzpatrick","year":"2016","unstructured":"Fitzpatrick CK, Maag C, Clary CW, Metcalfe A, Langhorn J, Rullkoetter PJ (2016) Validation of a new computational 6-dof knee simulator during dynamic activities. J Biomech 49(14):3177\u20133184. https:\/\/doi.org\/10.1016\/j.jbiomech.2016.07.040","journal-title":"J Biomech"},{"key":"3566_CR30","doi-asserted-by":"publisher","unstructured":"Pavia JM (2015) Testing goodness-of-fit with the kernel density estimator: Gofkernel. J Stat Softw 66:1\u201327. https:\/\/doi.org\/10.32614\/cran.package.gofkernel","DOI":"10.32614\/cran.package.gofkernel"},{"issue":"11","key":"3566_CR31","doi-asserted-by":"publisher","first-page":"2241","DOI":"10.1109\/tpami.2015.2513405","volume":"38","author":"J Yang","year":"2015","unstructured":"Yang J, Li H, Campbell D, Jia Y (2015) Go-icp: a globally optimal solution to 3d icp point-set registration. IEEE Trans Pattern Anal Mach Intell 38(11):2241\u20132254. https:\/\/doi.org\/10.1109\/tpami.2015.2513405","journal-title":"IEEE Trans Pattern Anal Mach Intell"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03566-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-025-03566-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-025-03566-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T01:30:25Z","timestamp":1779413425000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-025-03566-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,6]]},"references-count":31,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,4]]}},"alternative-id":["3566"],"URL":"https:\/\/doi.org\/10.1007\/s11548-025-03566-z","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,6]]},"assertion":[{"value":"26 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"M.M., J.Z., and S.R. are employees of Think Surgical Inc.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by the Concordia University Institutional Review Board (IRB) under protocol number 30020154 (May 28, 2024). Data originated from the ClinicalTrials.gov registered clinical trial NCT03017261.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}