{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:37:47Z","timestamp":1792802267546,"version":"4.5.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T00:00:00Z","timestamp":1769731200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T00:00:00Z","timestamp":1769731200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"MCI Management Center Innsbruck \u2013 Internationale Hochschule GmbH","id":[{"id":"https:\/\/ror.org\/021kg9v06","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This study aims to evaluate the hemodynamic effect of tilting after implantation of a bioprosthetic heart valve in an enlarged aortic annulus using computational fluid dynamics (CFD). The objective is to define the cost of excessive enlargement in transprosthetical flow and identify the optimal prosthesis size and implantation angle to reduce thrombosis and early degeneration.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Virtual implantation of a 23-mm bioprosthetic model was conducted in a prespecified virtual aortic annulus of 23\u00a0mm. CFD simulations were conducted to analyze the hemodynamic parameters, including wall shear stress and turbulent kinetic energy, for bioprosthetic heart valves of the 23\u00a0mm (perpendicular implantation), 25\u00a0mm, and 27\u00a0mm (tilted implantation at different angles) after virtual annular enlargement. The simulations utilized transient flow models and mesh convergence studies, to ensure numerical accuracy and clinical relevance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The 23-mm valve implanted without annular enlargement and in an aligned fashion to the annulus exhibited higher wall shear stress (WSS) and shear stress (SS) values than the 25-mm valve implanted at 12\u00b0 tilted position and better hemodynamics than the 27-mm valve at 25\u00b0 tilted position. The 25-mm valve after annular enlargement and implantation at 12\u00b0 tilted position achieved the best hemodynamic performance together with a 23% and 7% reduction of WSS and SS as compared to the 23-mm valve.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Slight oversizing and tilting after annular enlargement yields the best performance of an aortic bioprosthetic valve with lowest WSS and balanced turbulence.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11548-026-03577-4","type":"journal-article","created":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T15:55:25Z","timestamp":1769788525000},"page":"1949-1962","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Transient numerical simulation of hemodynamics in bioprosthetic heart valves: insights into valve sizing and thrombosis risk"],"prefix":"10.1007","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5026-6251","authenticated-orcid":false,"given":"M.","family":"Berger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Golks","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Gleissner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9379-2080","authenticated-orcid":false,"given":"T.","family":"Senfter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ch.","family":"Mayerl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7656-5812","authenticated-orcid":false,"given":"N.","family":"Bonaros","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6584-3488","authenticated-orcid":false,"given":"C. G.","family":"Tepek\u00f6yl\u00fc","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9173-7336","authenticated-orcid":false,"given":"L.","family":"Stastny","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Grimm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1459-7234","authenticated-orcid":false,"given":"M.","family":"Pillei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,30]]},"reference":[{"key":"3577_CR1","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1093\/eurheartj\/ehab395","volume":"43","author":"A Vahanian","year":"2022","unstructured":"Vahanian A, Beyersdorf F, Praz F, Milojevic M, Baldus JB, Capadanno D, Conradi L, Bonis M, Pualis R, Delgado V, Freemantle N, Gilard M, Haugaa H, Jeppsson A, J\u00fcni P, Pierard L, Prendergast B, Sadaba J, Tribouilloy C, Wojakwski W (2022) 2021 ESC\/EACTS guidelines for the management of valvular heart disease. Eur Heart J 43:561\u2013632. https:\/\/doi.org\/10.1093\/eurheartj\/ehab395","journal-title":"Eur Heart J"},{"key":"3577_CR2","unstructured":"Patibandla S, Heaton J, Azzam JS (2025) Aortic insufficiency. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; Treasure Island (FL)"},{"key":"3577_CR3","doi-asserted-by":"publisher","first-page":"1022","DOI":"10.1136\/hrt.2005.067363","volume":"92","author":"P Pibarot","year":"2006","unstructured":"Pibarot P, Dumesnil JG (2006) Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart 92:1022\u20131029. https:\/\/doi.org\/10.1136\/hrt.2005.067363","journal-title":"Heart"},{"key":"3577_CR4","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.1016\/j.athoracsur.2025.01.016","volume":"119","author":"SA Chen","year":"2025","unstructured":"Chen SA, Do-Nguyen CC, Titsworth M, Yang B (2025) Aortic annular enlargement: Y-incision rationale, technique, and outcomes. Ann Thorac Surg 119:1151\u20131165. https:\/\/doi.org\/10.1016\/j.athoracsur.2025.01.016","journal-title":"Ann Thorac Surg"},{"key":"3577_CR5","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1136\/thx.25.3.339","volume":"25","author":"R Nicks","year":"1970","unstructured":"Nicks R, Cartmill T, Bernstein L (1970) Hypoplasia of the aortic root. The problem of aortic valve replacement. Thorax 25:339\u2013346. https:\/\/doi.org\/10.1136\/thx.25.3.339","journal-title":"Thorax"},{"key":"3577_CR6","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1016\/S0022-5223(19)39673-4","volume":"70","author":"S Konno","year":"1975","unstructured":"Konno S, Imai Y, Iida Y, Nakajima M, Tatsuno K (1975) A new method for prosthetic valve replacement in congenital aortic stenosis associated with hypoplasia of the aortic valve ring. J Thorac Cardiovasc Surg 70:909\u2013917","journal-title":"J Thorac Cardiovasc Surg"},{"key":"3577_CR7","doi-asserted-by":"publisher","first-page":"2044","DOI":"10.1016\/j.athoracsur.2007.01.059","volume":"83","author":"MD Peterson","year":"2007","unstructured":"Peterson MD, Borger MA, Feindel CM, David TE (2007) Aortic annular enlargement during aortic valve replacement: improving results with time. Ann Thorac Surg 83:2044\u20132049. https:\/\/doi.org\/10.1016\/j.athoracsur.2007.01.059","journal-title":"Ann Thorac Surg"},{"key":"3577_CR8","doi-asserted-by":"publisher","first-page":"103595","DOI":"10.1016\/j.rineng.2024.103595","volume":"24","author":"RSVN Murty","year":"2024","unstructured":"Murty RSVN, Pabsetti P, Harish R (2024) CFD investigation of mechanical heart valve orientations in modulating left ventricular hemodynamics. Results Eng 24:103595. https:\/\/doi.org\/10.1016\/j.rineng.2024.103595","journal-title":"Results Eng"},{"key":"3577_CR9","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1136\/heartjnl-2015-308044","volume":"102","author":"PD Morris","year":"2016","unstructured":"Morris PD, Narracott A, von Tengg-Kobligk H, Soto D, Hsiao S, Lugu A, Evans P, Bressloff N, Lawford P, Hose D, Gunn J (2016) Computational fluid dynamics modelling in cardiovascular medicine. Heart 102:18\u201328. https:\/\/doi.org\/10.1136\/heartjnl-2015-308044","journal-title":"Heart"},{"key":"3577_CR10","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1016\/j.medengphy.2010.07.008","volume":"32","author":"KD Lau","year":"2010","unstructured":"Lau KD, Diaz V, Scambler P, Burriesci G (2010) Mitral valve dynamics in structural and fluid-structure interaction models. Med Eng Phys 32:1057\u20131064. https:\/\/doi.org\/10.1016\/j.medengphy.2010.07.008","journal-title":"Med Eng Phys"},{"key":"3577_CR11","doi-asserted-by":"publisher","DOI":"10.3390\/fluids4010019","author":"ME James","year":"2019","unstructured":"James ME, Papavassiliou DV, O\u2019Rear EA (2019) Use of computational fluid dynamics to analyze blood flow, hemolysis and sublethal damage to red blood cells in a bileaflet artificial heart valve. Fluids. https:\/\/doi.org\/10.3390\/fluids4010019"},{"key":"3577_CR12","first-page":"39","volume":"1","author":"G Ranjith","year":"2014","unstructured":"Ranjith G, Muraleedharan CV (2014) Computational fluid dynamics simulation of the dynamics of a tilting disc heart valve prosthesis during the opening and fully open phases. J Agric Life Sci 1:39\u201344","journal-title":"J Agric Life Sci"},{"key":"3577_CR13","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1007\/s40846-016-0106-3","volume":"36","author":"F Zhou","year":"2016","unstructured":"Zhou F, Cui YY, Wu LL, Cui YY, Wu LL, Yang J, Liu L, Maitz M, Brown I, Huang N (2016) Analysis of flow field in mechanical aortic bileaflet heart valves using finite volume method. J Med Biol Eng 36:110\u2013120. https:\/\/doi.org\/10.1007\/s40846-016-0106-3","journal-title":"J Med Biol Eng"},{"key":"3577_CR14","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.athoracsur.2017.12.044","volume":"106","author":"AG Cerillo","year":"2018","unstructured":"Cerillo AG, Amoretti F, Mariani M, Cigala E, Murzi M, Gasbarri T, Solinas M, Chiappino D (2018) Increased gradients after aortic valve replacement with the Perceval valve: the role of oversizing. Ann Thorac Surg 106:121\u2013128. https:\/\/doi.org\/10.1016\/j.athoracsur.2017.12.044","journal-title":"Ann Thorac Surg"},{"key":"3577_CR15","doi-asserted-by":"crossref","unstructured":"Berger M, Golks J, Gleissner L, Senfter T, Mayerl C, Gollmann-Tepek\u00f6yl\u00fc C, Stastmy L, Krapf C, Grimm M, Bonaros N, Pillei M (2025) Computational Fluid dynamics analysis of artificial aortic valves: impact of tilted implantation on hemodynamics. In: 39th EACTS Annual Meeting, Copenhagen, Denmark","DOI":"10.1093\/ejcts\/ezag041"},{"key":"3577_CR16","unstructured":"Golks J (2023) Comparative hemodynamic analysis of medtronic avalus heart valves using computational fluid dynamics. Master thesis, Management Center Innsbruck"},{"key":"3577_CR17","unstructured":"Gleissner L (2025) Computational fluid dynamic analysis of pulsatile flow in aortic heart valves: investigating hemodynamics under transient conditions. Master thesis, Management Center Innsbruck"},{"key":"3577_CR18","unstructured":"Sinnott MD, Cleary PW, Prakash M (2006) An investigation of pulsatile blood flow in a bifurcation artery using a grid-free method"},{"key":"3577_CR19","doi-asserted-by":"publisher","first-page":"Q33","DOI":"10.1186\/1532-429x-17-s1-q33","volume":"17","author":"D Giese","year":"2015","unstructured":"Giese D, Baessler B, Madershahian N, Choi YH, Maintz D, Brunck A (2015) In vitro evaluation of flow patterns and turbulent kinetic energy in trans-catheter aortic valve prostheses. J Cardiovasc Magn Reson 17:Q33. https:\/\/doi.org\/10.1186\/1532-429x-17-s1-q33","journal-title":"J Cardiovasc Magn Reson"},{"key":"3577_CR20","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1016\/j.jaccas.2022.01.009","volume":"4","author":"S Toggweiler","year":"2022","unstructured":"Toggweiler S, De Boeck B, Karakas O, G\u00fclan U (2022) Turbulent kinetic energy loss and shear stresses before and after transcatheter aortic valve replacement. JACC Case Rep 4:318\u2013320. https:\/\/doi.org\/10.1016\/j.jaccas.2022.01.009","journal-title":"JACC Case Rep"},{"key":"3577_CR21","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1007\/s13239-021-00536-9","volume":"12","author":"EL Manchester","year":"2021","unstructured":"Manchester EL, Pirola S, Salmasi MY, O\u2019Regan DP, Athanasiou T, Xu XY (2021) Analysis of turbulence effects in a patient-specific aorta with aortic valve stenosis. Cardiovasc Eng Technol 12:438\u2013453. https:\/\/doi.org\/10.1007\/s13239-021-00536-9","journal-title":"Cardiovasc Eng Technol"},{"key":"3577_CR22","doi-asserted-by":"publisher","first-page":"577188","DOI":"10.3389\/fphys.2020.577188","volume":"11","author":"B Becsek","year":"2020","unstructured":"Becsek B, Pietrasanta L, Obrist D (2020) Turbulent systolic flow downstream of a bioprosthetic aortic valve: velocity spectra, wall shear stresses, and turbulent dissipation rates. Front Physiol 11:577188. https:\/\/doi.org\/10.3389\/fphys.2020.577188","journal-title":"Front Physiol"},{"key":"3577_CR23","doi-asserted-by":"publisher","DOI":"10.3390\/fluids6080287","author":"HE Salman","year":"2021","unstructured":"Salman HE, Saltik L, Yalcin HC (2021) Computational analysis of wall shear stress patterns on calcified and bicuspid aortic valves: focus on radial and coaptation patterns. Fluids. https:\/\/doi.org\/10.3390\/fluids6080287"},{"key":"3577_CR24","doi-asserted-by":"publisher","first-page":"e005486","DOI":"10.1161\/CIRCIMAGING.116.005486","volume":"10","author":"C Binter","year":"2017","unstructured":"Binter C, Gotschy A, S\u00fcndermann SH, Frank M, Tanner FC, L\u00fcscher T, Manka R, Kozerke S (2017) Turbulent kinetic energy assessed by multipoint 4-dimensional flow magnetic resonance imaging provides additional information relative to echocardiography for the determination of aortic stenosis severity. Circ Cardiovasc Imaging 10:e005486. https:\/\/doi.org\/10.1161\/CIRCIMAGING.116.005486","journal-title":"Circ Cardiovasc Imaging"},{"key":"3577_CR25","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.imu.2017.09.001","volume":"9","author":"A Amindari","year":"2017","unstructured":"Amindari A, Saltik L, Kirkkopru K, Yacoub M, Yalcin HC (2017) Assessment of calcified aortic valve leaflet deformations and blood flow dynamics using fluid-structure interaction modeling. Inform Med Unlocked 9:191\u2013199. https:\/\/doi.org\/10.1016\/j.imu.2017.09.001","journal-title":"Inform Med Unlocked"},{"key":"3577_CR26","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1080\/14733315.2019.1667558","volume":"19","author":"N Baker","year":"2020","unstructured":"Baker N, Kelly G, O\u2019Sullivan PD (2020) A grid convergence index study of mesh style effect on the accuracy of the numerical results for an indoor airflow profile. Int J Vent 19:300\u2013314. https:\/\/doi.org\/10.1080\/14733315.2019.1667558","journal-title":"Int J Vent"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03577-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-026-03577-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03577-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:02:14Z","timestamp":1792800134000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-026-03577-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,30]]},"references-count":26,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["3577"],"URL":"https:\/\/doi.org\/10.1007\/s11548-026-03577-4","relation":{"references":[{"id-type":"doi","id":"10.3390\/fluids4010019","asserted-by":"subject"},{"id-type":"doi","id":"10.3390\/fluids6080287","asserted-by":"subject"}]},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,30]]},"assertion":[{"value":"13 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no conflict of interest.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"There were no human or animal studies involved.","order":2,"name":"Ethics","label":"Human and animal rights","group":{"name":"EthicsHeading","label":"Declarations"}}]}}