{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:38:11Z","timestamp":1792802291545,"version":"4.5.0"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2026,4,25]],"date-time":"2026-04-25T00:00:00Z","timestamp":1777075200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,25]],"date-time":"2026-04-25T00:00:00Z","timestamp":1777075200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002745","name":"Bayerische Forschungsstiftung","doi-asserted-by":"publisher","award":["AZ-1592-23-ForNeRo"],"award-info":[{"award-number":["AZ-1592-23-ForNeRo"]}],"id":[{"id":"10.13039\/501100002745","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>While laparoscopic procedures offer considerable advantages for the patient, they pose substantial challenges for the surgeon, whose hand-eye coordination is impaired. One reason for this is the surgeon\u2019s lost visual access to the surgical field, who is instead provided with an endoscopic image on a stationary monitor. In the present study, an optical see-through head-mounted display (OST-HMD) was used to display a virtual endoscope monitor. Unlike stationary monitors, this allows the endoscope image to be projected at arbitrary positions in the room.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      The benefits of this approach were evaluated in a user study.\n                      <jats:italic>N<\/jats:italic>\n                      = 10 surgeons carried out a threading task in a pelvic trainer integrated in an operating room setup. Four positions of the endoscope image were compared: frontal view (\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$0^{\\circ }$$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:msup>\n                              <mml:mn>0<\/mml:mn>\n                              <mml:mo>\u2218<\/mml:mo>\n                            <\/mml:msup>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      ), offset by\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$60^{\\circ }$$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:msup>\n                              <mml:mn>60<\/mml:mn>\n                              <mml:mo>\u2218<\/mml:mo>\n                            <\/mml:msup>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      to the left and right, and projected directly onto the surgical field.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The results show that for complex bimanual tasks, projecting the endoscope image onto the surgical field led to a halving of execution times in the study. In addition, the forces applied during threading were measured, but no significant effects of perspective were found. More experienced surgeons also reported significantly lower mental workload with the frontal view (\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$0^{\\circ }$$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:msup>\n                              <mml:mn>0<\/mml:mn>\n                              <mml:mo>\u2218<\/mml:mo>\n                            <\/mml:msup>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      ) and the projection onto the surgical field compared to the other conditions.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This study provides first evidence that an OST-HMD could be a suitable way for flexibly displaying endoscopic images in laparoscopy and could help improve the surgeon\u2019s hand-eye coordination, while at the same time being easily integrated into the clinical environment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11548-026-03620-4","type":"journal-article","created":{"date-parts":[[2026,4,25]],"date-time":"2026-04-25T11:12:53Z","timestamp":1777115573000},"page":"1973-1980","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Improving hand-eye-coordination in laparoscopy using a virtual endoscope monitor"],"prefix":"10.1007","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7857-0201","authenticated-orcid":false,"given":"Bernhard Michael","family":"Weber","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathilde","family":"Connan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Kirst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominik","family":"Schneider","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Wegener","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maximilian","family":"Berlet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonas","family":"Fuchtmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dirk","family":"Wilhelm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julian","family":"Klodmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,25]]},"reference":[{"key":"3620_CR1","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2021.799442","volume":"8","author":"I Alkatout","year":"2021","unstructured":"Alkatout I, Mechler U, Mettler L, Pape J, Maass N, Biebl M, Gitas G, Lagan\u00e0 AS, Freytag D (2021) The development of laparoscopy-a historical overview. Front Surg 8:799442. https:\/\/doi.org\/10.3389\/fsurg.2021.799442","journal-title":"Front Surg"},{"issue":"5","key":"3620_CR2","doi-asserted-by":"publisher","first-page":"2677","DOI":"10.1007\/s00464-024-10774-2","volume":"38","author":"D Ferrari","year":"2024","unstructured":"Ferrari D, Violante T, Novelli M, Starlinger PP, Smoot RL, Reisenauer JS, Larson DW (2024) The death of laparoscopy. Surg Endosc 38(5):2677\u20132688. https:\/\/doi.org\/10.1007\/s00464-024-10774-2","journal-title":"Surg Endosc"},{"issue":"3","key":"3620_CR3","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1080\/136457001753192277","volume":"10","author":"B Wentink","year":"2001","unstructured":"Wentink B (2001) Eye-hand coordination in laparoscopy-an overview of experiments and supporting aids. Minim Invasive Ther Allied Technol 10(3):155\u2013162. https:\/\/doi.org\/10.1080\/136457001753192277","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"3620_CR4","unstructured":"Xin H, Zelek J, Carnahan H (2006) Laparoscopic surgery, perceptual limitations and force: a review. In: First canadian student conference on biomedical computing, vol 144. Queen\u2019s University Kingston, ON, Canada"},{"issue":"4","key":"3620_CR5","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1097\/00019509-199608000-00006","volume":"6","author":"WC Meng","year":"1996","unstructured":"Meng WC, Kwok SP, Leung K, Chung C, Lau W, Li AK (1996) Optimal position of working ports in laparoscopic surgery: an in vitro study. Surg Laparosc Endosc Percutaneous Tech 6(4):278\u2013281","journal-title":"Surg Laparosc Endosc Percutaneous Tech"},{"issue":"4","key":"3620_CR6","first-page":"331","volume":"1","author":"M Medina","year":"1997","unstructured":"Medina M (1997) Image rotation and reversal-major obstacles in learning intracorporeal suturing and knot-tying. JSLS J Soc Laparoendosc Surg 1(4):331","journal-title":"JSLS J Soc Laparoendosc Surg"},{"issue":"6","key":"3620_CR7","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1007\/s00464-007-9360-3","volume":"21","author":"LA Haveran","year":"2007","unstructured":"Haveran LA, Novitsky YW, Czerniach DR, Kaban GK, Taylor M, Gallagher-Dorval K, Schmidt R, Kelly JJ, Litwin DE (2007) Optimizing laparoscopic task efficiency: the role of camera and monitor positions. Surg Endosc 21(6):980\u2013984. https:\/\/doi.org\/10.1007\/s00464-007-9360-3","journal-title":"Surg Endosc"},{"issue":"4","key":"3620_CR8","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1097\/00000658-199804000-00005","volume":"227","author":"GB Hanna","year":"1998","unstructured":"Hanna GB, Shimi SM, Cuschieri A (1998) Task performance in endoscopic surgery is influenced by location of the image display. Ann Surg 227(4):481\u2013484","journal-title":"Ann Surg"},{"key":"3620_CR9","doi-asserted-by":"publisher","unstructured":"Matern U, Kehl K, Giebmeyer C, Faist M (2002) Monitor-position in laparoscopic surgery. In: Proceedings of the human factors and ergonomics society annual meeting, vol 46, pp 1506\u20131510. https:\/\/doi.org\/10.1177\/154193120204601621 . SAGE Publications Sage CA: Los Angeles, CA","DOI":"10.1177\/154193120204601621"},{"issue":"1","key":"3620_CR10","doi-asserted-by":"publisher","first-page":"87","DOI":"10.5114\/wiitm.2014.47434","volume":"10","author":"DA Walczak","year":"2015","unstructured":"Walczak DA, Pawe\u0142czak D, Piotrowski P, Trzeciak PW, J\u0119drzejczyk A, Pasieka Z (2015) Video display during laparoscopy-where should it be placed? Videosurg Other Miniinvasive Tech 10(1):87\u201391. https:\/\/doi.org\/10.5114\/wiitm.2014.47434","journal-title":"Videosurg Other Miniinvasive Tech"},{"key":"3620_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbi.2020.103463","volume":"107","author":"ER Zorzal","year":"2020","unstructured":"Zorzal ER, Gomes JMC, Sousa M, Belchior P, Da Silva PG, Figueiredo N, Lopes DS, Jorge J (2020) Laparoscopy with augmented reality adaptations. J Biomed Inform 107:103463. https:\/\/doi.org\/10.1016\/j.jbi.2020.103463","journal-title":"J Biomed Inform"},{"key":"3620_CR12","doi-asserted-by":"publisher","unstructured":"Budjakoski N, Schneider D, Song T, Sommersperger M, Weber B, Navab N, Klodmann J (2025) Design and effectiveness of virtual monitors and AR-based endoscope control for robotically assisted laparoscopic surgery. In: 2025 IEEE International conference on robotics and automation (ICRA), pp 6882\u20136888. https:\/\/doi.org\/10.1109\/ICRA55743.2025.11128626. IEEE","DOI":"10.1109\/ICRA55743.2025.11128626"},{"issue":"9","key":"3620_CR13","doi-asserted-by":"publisher","first-page":"1961","DOI":"10.1007\/s00268-011-1141-4","volume":"35","author":"MR Wilson","year":"2011","unstructured":"Wilson MR, Poolton JM, Malhotra N, Ngo K, Bright E, Masters RS (2011) Development and validation of a surgical workload measure: the surgery task load index (SURG-TLX). World J Surg 35(9):1961\u20131969. https:\/\/doi.org\/10.1007\/s00268-011-1141-4","journal-title":"World J Surg"},{"issue":"1","key":"3620_CR14","doi-asserted-by":"publisher","first-page":"19215","DOI":"10.1038\/s41598-023-46641-8","volume":"13","author":"M Bergholz","year":"2023","unstructured":"Bergholz M, Ferle M, Weber BM (2023) The benefits of haptic feedback in robot assisted surgery and their moderators: a meta-analysis. Sci Rep 13(1):19215","journal-title":"Sci Rep"},{"key":"3620_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.artmed.2020.102007","volume":"112","author":"P Castillo-Segura","year":"2021","unstructured":"Castillo-Segura P, Fernandez-Panadero C, Alario-Hoyos C, Munoz-Merino PJ, Kloos CD (2021) Objective and automated assessment of surgical technical skills with IoT systems: a systematic literature review. Artif Intell Med 112:102007","journal-title":"Artif Intell Med"},{"issue":"6","key":"3620_CR16","doi-asserted-by":"publisher","first-page":"1279","DOI":"10.1007\/s00464-008-0148-x","volume":"23","author":"M Van Det","year":"2009","unstructured":"Van Det M, Meijerink W, Hoff C, Tott\u00e9 E, Pierie J (2009) Optimal ergonomics for laparoscopic surgery in minimally invasive surgery suites: a review and guidelines. Surg Endosc 23(6):1279\u20131285","journal-title":"Surg Endosc"},{"key":"3620_CR17","doi-asserted-by":"publisher","unstructured":"Britton CR, Francis I, Tay LJ, Krishnamoothy B (2022) The role of the bedside assistant in robot-assisted surgery: a critical synthesis. J Perioper Pract 32(9):208\u2013225. https:\/\/doi.org\/10.1177\/17504589221094136","DOI":"10.1177\/17504589221094136"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03620-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-026-03620-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03620-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:02:50Z","timestamp":1792800170000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-026-03620-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,25]]},"references-count":17,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["3620"],"URL":"https:\/\/doi.org\/10.1007\/s11548-026-03620-4","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,25]]},"assertion":[{"value":"9 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Bernhard M Weber, Mathilde Connan, Alexander Kirst, Dominik Schneider, Luca Wegener, Maximilian Berlet, Jonas Fuchtmann, Dirk Wilhelm and Julian Klodmann declare to have no financial or non-financial interests to disclose.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study has been approved by the ethics committee of the Technical University of Munich (vote nr. 2024-22-S-SB) and was in accordance with the Declaration of Helsinki. Written informed consent was obtained from all participants in the study. Furthermore, surgeons signed informed consent regarding publishing their data.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}}]}}