{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T02:29:26Z","timestamp":1793500166497,"version":"4.5.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T00:00:00Z","timestamp":1780617600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T00:00:00Z","timestamp":1780617600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"German Federal Ministry of Research, Technology, and Space","award":["13GW0473A"],"award-info":[{"award-number":["13GW0473A"]}],"id":[{"id":"https:\/\/ror.org\/04pz7b180","id-type":"ROR","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100008530","name":"European Regional Development Fund","doi-asserted-by":"publisher","award":["ZS\/2023\/12\/182010"],"award-info":[{"award-number":["ZS\/2023\/12\/182010"]}],"id":[{"id":"10.13039\/501100008530","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>Accurate needle tracking is critical for the success of computed tomography (CT)-guided interventions, where even minor deviations may compromise procedural safety and clinical outcomes. However, existing image-guided tracking systems typically lack mechanisms to quantify and communicate the reliability of their predictions in real time, leaving clinicians to act on guidance of uncertain trustworthiness.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      We propose a\n                      <jats:italic>Dynamic Uncertainty Level Assessment Framework<\/jats:italic>\n                      that provides a quantitative, real-time estimate of tracking reliability by linearly linking a predicted uncertainty score to spatial tracking error. The framework consists of three different approaches: (1) a classic method based on dynamically weighted, interpretable reliability metrics; (2) a lightweight convolutional neural network (CNN) that predicts uncertainty directly from multi-view image data; and (3) a hybrid CNN that adaptively optimizes metric weights while preserving interpretability. The uncertainty level is defined on a fixed scale, with\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$0\\%$$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:mrow>\n                              <mml:mn>0<\/mml:mn>\n                              <mml:mo>%<\/mml:mo>\n                            <\/mml:mrow>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      corresponding to ideal tracking (error of 0\u00a0mm) and\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$100\\%$$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:mrow>\n                              <mml:mn>100<\/mml:mn>\n                              <mml:mo>%<\/mml:mo>\n                            <\/mml:mrow>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      to a tracking error of 10\u00a0mm.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Experimental validation on clinical and clinically realistic laboratory datasets of\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$\\sim $$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:mo>\u223c<\/mml:mo>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      30,000 frames demonstrates a strong positive correlation between uncertainty and error (Pearson\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$r &gt; 0.82$$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:mrow>\n                              <mml:mi>r<\/mml:mi>\n                              <mml:mo>&gt;<\/mml:mo>\n                              <mml:mn>0.82<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      ) and achieves a stable tracking error estimation (error difference\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$&lt;0.6$$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:mrow>\n                              <mml:mo>&lt;<\/mml:mo>\n                              <mml:mn>0.6<\/mml:mn>\n                            <\/mml:mrow>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      \u00a0mm) with real-time performance (5\u00a0ms per frame).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>By enabling an intuitive uncertainty-to-error mapping, the proposed framework supports more informed intra-procedural decision-making, enhances operator trust in guidance data, and establishes a practical basis for integration into uncertainty-aware CT-guided intervention systems.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11548-026-03725-w","type":"journal-article","created":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T13:12:33Z","timestamp":1780665153000},"page":"2135-2145","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Dynamic uncertainty-level assessment framework for real-time needle tracking in CT-guided surgical environments"],"prefix":"10.1007","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0979-0905","authenticated-orcid":false,"given":"Max","family":"Steiger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1810-6511","authenticated-orcid":false,"given":"Mohammad","family":"Rezapourian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marko","family":"Rak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5734-7529","authenticated-orcid":false,"given":"Christian","family":"Hansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,5]]},"reference":[{"key":"3725_CR1","doi-asserted-by":"publisher","unstructured":"Lastrucci A, Iosca N, Wandael Y, Barra A, Lepri G, Forini N, Ricci R, Miele V, Giansanti D (2025) AI and interventional radiology: a narrative review of reviews on opportunities, challenges, and future directions. Diagnostics 15(7):893. https:\/\/doi.org\/10.3390\/diagnostics15070893. PMID: 40218243; PMCID: PMC11988467","DOI":"10.3390\/diagnostics15070893"},{"key":"3725_CR2","doi-asserted-by":"publisher","first-page":"493","DOI":"10.2174\/1874325001711010493","volume":"11","author":"KR Gundle","year":"2017","unstructured":"Gundle KR, White JK, Conrad EU, Ching RP (2017) Accuracy and precision of a surgical navigation system: effect of camera and patient tracker position and number of active markers. Open Orthop J 11:493\u2013501. https:\/\/doi.org\/10.2174\/1874325001711010493","journal-title":"Open Orthop J"},{"issue":"3","key":"3725_CR3","doi-asserted-by":"publisher","DOI":"10.1016\/j.tvir.2023.100911","volume":"26","author":"AM Sorensen","year":"2023","unstructured":"Sorensen AM, Zlevor AM, Kisting MA, Couillard AB, Ziemlewicz TJ, Toia GV, Hinshaw JL, Woods M, Stratchko LM, Pickhardt PJ, Foltz ML, Peppler WW, Lee FTJ, Knavel Koepsel EM (2023) CT navigation for percutaneous needle placement: How i do it. Tech Vasc Interv Radiol 26(3):100911. https:\/\/doi.org\/10.1016\/j.tvir.2023.100911","journal-title":"Tech Vasc Interv Radiol"},{"issue":"10","key":"3725_CR4","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.1007\/s11548-020-02226-8","volume":"15","author":"X Li","year":"2020","unstructured":"Li X, Young AS, Raman SS, Lu DS, Lee YH, Tsao TC, Wu HH (2020) Automatic needle tracking using mask R-CNN for MRI-guided percutaneous interventions. Int J Comput Assist Radiol Surg 15(10):1673\u20131684. https:\/\/doi.org\/10.1007\/s11548-020-02226-8","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"1","key":"3725_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.metrad.2023.100003","volume":"1","author":"K Zou","year":"2023","unstructured":"Zou K, Chen Z, Yuan X, Shen X, Wang M, Fu H (2023) A review of uncertainty estimation and its application in medical imaging. Meta-Radiology 1(1):100003. https:\/\/doi.org\/10.1016\/j.metrad.2023.100003","journal-title":"Meta-Radiology"},{"key":"3725_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2020.101855","volume":"68","author":"FC Ghesu","year":"2021","unstructured":"Ghesu FC, Georgescu B, Mansoor A, Yoo Y, Gibson E, Vishwanath RS, Balachandran A, Balter JM, Cao Y, Singh R, Digumarthy SR, Kalra MK, Grbic S, Comaniciu D (2021) Quantifying and leveraging predictive uncertainty for medical image assessment. Med Image Anal 68:101855. https:\/\/doi.org\/10.1016\/j.media.2020.101855","journal-title":"Med Image Anal"},{"issue":"8","key":"3725_CR7","doi-asserted-by":"publisher","first-page":"1702","DOI":"10.1109\/TMI.2014.2321777","volume":"33","author":"AM Franz","year":"2014","unstructured":"Franz AM, Haidegger T, Birkfellner W, Cleary K, Peters TM, Maier-Hein L (2014) Electromagnetic tracking in medicine-a review of technology, validation, and applications. IEEE Trans Med Imaging 33(8):1702\u20131725. https:\/\/doi.org\/10.1109\/TMI.2014.2321777. (Epub 2014 May 5)","journal-title":"IEEE Trans Med Imaging"},{"key":"3725_CR8","doi-asserted-by":"publisher","unstructured":"Wang Y, Perez SAH, Harada K (2025) Monocular suture needle pose detection using synthetic data augmented convolutional neural network. Int J Comput Assist Radiol Surg https:\/\/doi.org\/10.1007\/s11548-025-03467-1","DOI":"10.1007\/s11548-025-03467-1"},{"issue":"12","key":"3725_CR9","doi-asserted-by":"publisher","first-page":"3868","DOI":"10.1109\/TMI.2020.3006437","volume":"39","author":"A Mehrtash","year":"2020","unstructured":"Mehrtash A, Wells WM, Tempany CM, Abolmaesumi P, Kapur T (2020) Confidence calibration and predictive uncertainty estimation for deep medical image segmentation. IEEE Trans Med Imaging 39(12):3868\u20133878. https:\/\/doi.org\/10.1109\/TMI.2020.3006437","journal-title":"IEEE Trans Med Imaging"},{"key":"3725_CR10","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2022.102655","volume":"83","author":"J Linmans","year":"2023","unstructured":"Linmans J, Elfwing S, Laak J, Litjens G (2023) Predictive uncertainty estimation for out-of-distribution detection in digital pathology. Med Image Anal 83:102655. https:\/\/doi.org\/10.1016\/j.media.2022.102655. (Epub 2022 Oct 17)","journal-title":"Med Image Anal"},{"key":"3725_CR11","unstructured":"Blundell C, Cornebise J, Kavgukcuoglu K, Wierstra D. Weight uncertainty in neural network. In: Bach F, Blei D. (eds.) Proceedings of the 32nd International conference on machine learning. Proceedings of machine learning Research, vol 37, p 1613\u20131622. PMLR, Lille, France (2015). https:\/\/proceedings.mlr.press\/v37\/blundell15.html"},{"key":"3725_CR12","doi-asserted-by":"publisher","DOI":"10.5281\/zenodo.18188564","author":"M Steiger","year":"2026","unstructured":"Steiger M, Rezapourian M, Rak M, Hansen C (2026) Dynamic uncertainty level assessment framework for real-time needle tracking in ct-guided surgical environments - dataset. Zenodo. https:\/\/doi.org\/10.5281\/zenodo.18188564","journal-title":"Zenodo"},{"key":"3725_CR13","doi-asserted-by":"publisher","DOI":"10.1109\/CVPR52688.2022.01167","author":"Z Liu","year":"2022","unstructured":"Liu Z, Mao H, Wu C-Y, Feichtenhofer C, Darrell T, Xie S (2022) A convnet for the 2020s. Proceedings of the IEEE\/CVF conference on computer vision and pattern recognition (CVPR). https:\/\/doi.org\/10.1109\/CVPR52688.2022.01167","journal-title":"Proceedings of the IEEE\/CVF conference on computer vision and pattern recognition (CVPR)"},{"key":"3725_CR14","doi-asserted-by":"crossref","unstructured":"Hartley RI, Zisserman A (2004) Multiple view geometry in computer vision, 2nd edn. Cambridge University Press, Cambridge, UK","DOI":"10.1017\/CBO9780511811685"},{"key":"3725_CR15","doi-asserted-by":"publisher","unstructured":"Howard A, Sandler M, Chu G, Chen L.-C, Chen B, Tan M, Wang W, Zhu Y, Pang R, Vasudevan V, Le QV, Adam H (2019) Searching for MobileNetV3 . https:\/\/doi.org\/10.48550\/arXiv.1905.02244 . arxiv:1905.02244","DOI":"10.48550\/arXiv.1905.02244"},{"key":"3725_CR16","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1164\/rccm.200612-1866OC","volume":"176","author":"R Eberhardt","year":"2007","unstructured":"Eberhardt R, Anantham D, Ernst A, Feller-Kopman D, Herth F (2007) Multimodality bronchoscopic diagnosis of peripheral lung lesions. Am J Respir Crit Care Med 176:36\u201341","journal-title":"Am J Respir Crit Care Med"},{"issue":"9","key":"3725_CR17","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1164\/rccm.200603-344OC","volume":"174","author":"TR Gildea","year":"2006","unstructured":"Gildea TR, Mazzone PJ, Karnak D, Meziane M, Mehta AC (2006) Electromagnetic navigation diagnostic bronchoscopy: A prospective study. Am J Respir Crit Care Med 174(9):982\u2013989. https:\/\/doi.org\/10.1164\/rccm.200603-344OC","journal-title":"Am J Respir Crit Care Med"},{"key":"3725_CR18","doi-asserted-by":"crossref","unstructured":"Smits MLJ et al (2019) Robotic versus freehand needle positioning in ct-guided ablation of liver tumors: a randomized controlled trial. Radiology 290(3):826\u2013832","DOI":"10.1148\/radiol.2018181698"},{"issue":"1","key":"3725_CR19","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1053\/j.semradonc.2003.10.008","volume":"14","author":"H Shirato","year":"2004","unstructured":"Shirato H, Seppenwoolde Y, Kitamura K, Onimura R, Shimizu S (2004) Intrafractional tumor motion: lung and liver. Semin Radiat Oncol 14(1):10\u201318. https:\/\/doi.org\/10.1053\/j.semradonc.2003.10.008","journal-title":"Semin Radiat Oncol"},{"key":"3725_CR20","doi-asserted-by":"crossref","unstructured":"Pritchett MA, Bhadra K, Calcutt M, Folch E (2020) Virtual or reality: divergence between preprocedural computed tomography scans and lung anatomy during guided bronchoscopy. J Thorac Dis 12(4):1595\u20131611","DOI":"10.21037\/jtd.2020.01.35"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03725-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-026-03725-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-026-03725-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T02:02:15Z","timestamp":1793498535000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-026-03725-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,5]]},"references-count":20,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2026,10]]}},"alternative-id":["3725"],"URL":"https:\/\/doi.org\/10.1007\/s11548-026-03725-w","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,5]]},"assertion":[{"value":"10 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no known competing financial interests or personal relationships that could have influenced the work reported in this paper.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}}]}}