{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T16:32:03Z","timestamp":1783528323443,"version":"3.55.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T00:00:00Z","timestamp":1739404800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T00:00:00Z","timestamp":1739404800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100005609","name":"University of Turku","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100005609","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["SIViP"],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>\n            <jats:italic>Background:<\/jats:italic> Measurement of full width at half maximum (FWHM) is used in multiple important applications related to the evaluation of the image resolution and the performance assessment of different scanner devices especially in positron emission tomography (PET) imaging, but little research has been performed about different methods for estimating FWHM.<jats:italic>Materials and methods<\/jats:italic>: We study seven different methods for estimating FWHM, including measuring FWHM according to its definition, four methods based on estimation of the standard deviation, the standard method of National Electrical Manufacturers Association (NEMA), and a new method utilizing an optimization algorithm to fit a Gaussian curve to the data. We compare their performance with several simulations. We also apply these techniques on two real data sets created by PET images of an <jats:inline-formula>\n              <jats:alternatives>\n                <jats:tex-math>$$^{18}$$<\/jats:tex-math>\n                <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                  <mml:mmultiscripts>\n                    <mml:mrow\/>\n                    <mml:mrow\/>\n                    <mml:mn>18<\/mml:mn>\n                  <\/mml:mmultiscripts>\n                <\/mml:math>\n              <\/jats:alternatives>\n            <\/jats:inline-formula>F-fluorodeoxyglucose resolution phantom imaged with High Resolution Research Tomograph concept camera and Biograph Vision Quadra and a sodium-22 point source imaged with RAYCAN X5 PET\/CT system. <jats:italic>Results and conclusion<\/jats:italic>: According to our results from both simulated and real data, the most accurate methods are the first method based on the definition of FWHM and the NEMA standard method. In particular, both of these methods work in a reliable way in real data experiments, even when there is a very limited number of points available for FWHM computation.<\/jats:p>","DOI":"10.1007\/s11760-025-03820-6","type":"journal-article","created":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T10:52:14Z","timestamp":1739443934000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Methods for estimating full width at half maximum"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7775-7656","authenticated-orcid":false,"given":"Oona","family":"Rainio","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johanna","family":"H\u00e4llil\u00e4","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9401-0725","authenticated-orcid":false,"given":"Jarmo","family":"Teuho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0982-8360","authenticated-orcid":false,"given":"Riku","family":"Kl\u00e9n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,2,13]]},"reference":[{"issue":"16","key":"3820_CR1","doi-asserted-by":"crossref","first-page":"3245","DOI":"10.1063\/1.1621088","volume":"83","author":"F Chen","year":"2003","unstructured":"Chen, F., Itagi, A., Bain, J., Stancil, D., Schlesinger, T., Stebounova, L., Walker, G., Akhremitchev, B.: Imaging of optical field confinement in ridge waveguides fabricated on very-small-aperture laser. Appl. Phys. Lett. 83(16), 3245\u20133247 (2003)","journal-title":"Appl. Phys. Lett."},{"key":"3820_CR2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s11082-016-0766-9","volume":"48","author":"S Chiangga","year":"2016","unstructured":"Chiangga, S., Suwanarat, S., Phatharacorn, P., Yupapin, P.: Super-continuum generation of an optical pulse in a silicon micro-ring resonator. Opt. Quant. Electron. 48, 1\u201313 (2016)","journal-title":"Opt. Quant. Electron."},{"issue":"13","key":"3820_CR3","doi-asserted-by":"crossref","first-page":"1687","DOI":"10.1063\/1.111832","volume":"64","author":"S Nakamura","year":"1994","unstructured":"Nakamura, S., Mukai, T., Senoh, M.: Candela-class high-brightness ingan\/algan double-heterostructure blue-light-emitting diodes. Appl. Phys. Lett. 64(13), 1687\u20131689 (1994)","journal-title":"Appl. Phys. Lett."},{"issue":"15","key":"3820_CR4","doi-asserted-by":"crossref","first-page":"2067","DOI":"10.1063\/1.119344","volume":"71","author":"J Wu","year":"1997","unstructured":"Wu, J., Yaguchi, H., Onabe, K., Ito, R., Shiraki, Y.: Photoluminescence properties of cubic gan grown on gaas (100) substrates by metalorganic vapor phase epitaxy. Appl. Phys. Lett. 71(15), 2067\u20132069 (1997)","journal-title":"Appl. Phys. Lett."},{"key":"3820_CR5","unstructured":"Anisimova, E., Bedn\u00e1\u0159, J., P\u00e1ta, P.: Efficiency of wavelet coefficients thresholding techniques used for multimedia and astronomical image denoising. In: 2013 International Conference on Applied Electronics, pp. 1\u20134 (2013). IEEE"},{"issue":"21","key":"3820_CR6","doi-asserted-by":"crossref","first-page":"18643","DOI":"10.1364\/OE.17.018643","volume":"17","author":"N Cvetojevic","year":"2009","unstructured":"Cvetojevic, N., Lawrence, J., Ellis, S., Bland-Hawthorn, J., Haynes, R., Horton, A.: Characterization and on-sky demonstration of an integrated photonic spectrograph for astronomy. Opt. Express 17(21), 18643\u201318650 (2009)","journal-title":"Opt. Express"},{"issue":"12","key":"3820_CR7","doi-asserted-by":"crossref","first-page":"1914","DOI":"10.2967\/jnumed.111.092726","volume":"52","author":"G Delso","year":"2011","unstructured":"Delso, G., F\u00fcrst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S.G., Schwaiger, M., Ziegler, S.I.: Performance measurements of the siemens mmr integrated whole-body pet\/mr scanner. J. Nucl. Med. 52(12), 1914\u20131922 (2011)","journal-title":"J. Nucl. Med."},{"issue":"11","key":"3820_CR8","doi-asserted-by":"crossref","first-page":"1768","DOI":"10.2967\/jnumed.118.209593","volume":"59","author":"MA Lodge","year":"2018","unstructured":"Lodge, M.A., Leal, J.P., Rahmim, A., Sunderland, J.J., Frey, E.C.: Measuring pet spatial resolution using a cylinder phantom positioned at an oblique angle. J. Nucl. Med. 59(11), 1768\u20131775 (2018)","journal-title":"J. Nucl. Med."},{"issue":"8","key":"3820_CR9","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.2967\/jnumed.108.060079","volume":"50","author":"MA Lodge","year":"2009","unstructured":"Lodge, M.A., Rahmim, A., Wahl, R.L.: A practical, automated quality assurance method for measuring spatial resolution in pet. J. Nucl. Med. 50(8), 1307\u20131314 (2009)","journal-title":"J. Nucl. Med."},{"key":"3820_CR10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40658-015-0132-1","volume":"2","author":"I Rausch","year":"2015","unstructured":"Rausch, I., Cal-Gonz\u00e1lez, J., Dapra, D., Gallowitsch, H.J., Lind, P., Beyer, T., Minear, G.: Performance evaluation of the biograph mct flow pet\/ct system according to the nema nu2-2012 standard. EJNMMI Phys. 2, 1\u201317 (2015)","journal-title":"EJNMMI Phys."},{"issue":"6","key":"3820_CR11","doi-asserted-by":"crossref","first-page":"861","DOI":"10.2967\/jnumed.120.250597","volume":"62","author":"BA Spencer","year":"2021","unstructured":"Spencer, B.A., Berg, E., Schmall, J.P., Omidvari, N., Leung, E.K., Abdelhafez, Y.G., Tang, S., Deng, Z., Dong, Y., Lv, Y., et al.: Performance evaluation of the uexplorer total-body pet\/ct scanner based on nema nu 2\u20132018 with additional tests to characterize pet scanners with a long axial field of view. J. Nucl. Med. 62(6), 861\u2013870 (2021)","journal-title":"J. Nucl. Med."},{"key":"3820_CR12","unstructured":"National Electrical Manufacturers\u00a0Association, N.N.: Performance Measures of Positron Emission Tomographs (2013)"},{"issue":"1","key":"3820_CR13","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/0168-9002(89)91258-8","volume":"283","author":"N Markevich","year":"1989","unstructured":"Markevich, N., Gertner, I.: Comparison among methods for calculating fwhm. Nuclear Instrument Methods Phys Res Sect A Accelerators Spectrometers Detectors Assoc Equipment 283(1), 72\u201377 (1989)","journal-title":"Nuclear Instrument Methods Phys Res Sect A Accelerators Spectrometers Detectors Assoc Equipment"},{"key":"3820_CR14","unstructured":"Team, R.C.: R: A language and environment for statistical computing, r foundation for statistical computing (2020)"},{"key":"3820_CR15","doi-asserted-by":"crossref","unstructured":"De Jong, H.W., Van Velden, F.H., Kloet, R.W., Buijs, F.L., Boellaard, R., Lammertsma, A.A.: Performance evaluation of the ecat hrrt: an lso-lyso double layer high resolution, high sensitivity scanner. Phys. Med. Biol. 52(5), 1505 (2007)","DOI":"10.1088\/0031-9155\/52\/5\/019"},{"issue":"3","key":"3820_CR16","doi-asserted-by":"crossref","first-page":"476","DOI":"10.2967\/jnumed.121.261972","volume":"63","author":"GA Prenosil","year":"2022","unstructured":"Prenosil, G.A., Sari, H., F\u00fcrstner, M., Afshar-Oromieh, A., Shi, K., Rominger, A., Hentschel, M.: Performance characteristics of the biograph vision quadra pet\/ct system with a long axial field of view using the nema nu 2\u20132018 standard. J. Nucl. Med. 63(3), 476\u2013484 (2022)","journal-title":"J. Nucl. Med."},{"issue":"4","key":"3820_CR17","doi-asserted-by":"crossref","first-page":"1885","DOI":"10.1007\/s10278-023-00812-1","volume":"36","author":"O Rainio","year":"2023","unstructured":"Rainio, O., Han, C., Teuho, J., Nesterov, S.V., Oikonen, V., Piirola, S., Laitinen, T., T\u00e4tt\u00e4l\u00e4inen, M., Knuuti, J., Kl\u00e9n, R.: Carimas: an extensive medical imaging data processing tool for research. J. Digit. Imaging 36(4), 1885\u20131893 (2023)","journal-title":"J. Digit. Imaging"},{"key":"3820_CR18","unstructured":"H\u00e4llil\u00e4, J.: Cross-calibration of human PET scanners with phantom studies. Master\u2019s thesis, University of Turku (2023)"}],"container-title":["Signal, Image and Video Processing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11760-025-03820-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11760-025-03820-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11760-025-03820-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,2]],"date-time":"2025-04-02T01:01:52Z","timestamp":1743555712000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11760-025-03820-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,13]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["3820"],"URL":"https:\/\/doi.org\/10.1007\/s11760-025-03820-6","relation":{},"ISSN":["1863-1703","1863-1711"],"issn-type":[{"value":"1863-1703","type":"print"},{"value":"1863-1711","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,13]]},"assertion":[{"value":"4 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 November 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 February 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"On behalf of all authors, the corresponding author states that there is no Conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"289"}}