{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T16:42:32Z","timestamp":1779381752812,"version":"3.53.1"},"reference-count":70,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2024,6,11]],"date-time":"2024-06-11T00:00:00Z","timestamp":1718064000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,6,11]],"date-time":"2024-06-11T00:00:00Z","timestamp":1718064000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neuroinform"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Pooling data across diverse sources acquired by multisite consortia requires compliance with a predefined reference protocol <jats:italic>i.e.<\/jats:italic>, ensuring different sites and scanners for a given project have used identical or compatible MR physics parameter values. Traditionally, this has been an arduous and manual process due to difficulties in working with the complicated DICOM standard and lack of resources allocated towards protocol compliance. Moreover, issues of protocol compliance is often overlooked for lack of realization that parameter values are routinely improvised\/modified locally at various sites. The inconsistencies in acquisition protocols can reduce SNR, statistical power, and in the worst case, may invalidate the results altogether. An open-source tool, mrQA was developed to automatically assess protocol compliance on standard dataset formats such as DICOM and BIDS, and to study the patterns of non-compliance in over 20 open neuroimaging datasets, including the large ABCD study. The results demonstrate that the lack of compliance is rather pervasive. The frequent sources of non-compliance include but are not limited to deviations in Repetition Time, Echo Time, Flip Angle, and Phase Encoding Direction. It was also observed that GE and Philips scanners exhibited higher rates of non-compliance relative to the Siemens scanners in the ABCD dataset. Continuous monitoring for protocol compliance is strongly recommended before any pre\/post-processing, ideally right after the acquisition, to avoid the silent propagation of severe\/subtle issues. Although, this study focuses on neuroimaging datasets, the proposed tool mrQA can work with any DICOM-based datasets.<\/jats:p>","DOI":"10.1007\/s12021-024-09668-4","type":"journal-article","created":{"date-parts":[[2024,6,11]],"date-time":"2024-06-11T08:01:56Z","timestamp":1718092916000},"page":"297-315","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Solving the Pervasive Problem of Protocol Non-Compliance in MRI using an Open-Source tool mrQA"],"prefix":"10.1007","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8498-8559","authenticated-orcid":false,"given":"Harsh","family":"Sinha","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4662-0558","authenticated-orcid":false,"given":"Pradeep Reddy","family":"Raamana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,6,11]]},"reference":[{"key":"9668_CR1","doi-asserted-by":"publisher","unstructured":"Allison, J., & Yanasak, N. (2015, August). What MRI Sequences Produce the Highest Specific Absorption Rate (SAR), and Is There Something We Should Be Doing to Reduce the SAR During Standard Examinations? American Journal of Roentgenology, 205(2), W140\u2013W140. https:\/\/doi.org\/10.2214\/AJR.14.14173. [2022-08-12] https:\/\/www.ajronline.org\/doi\/10.2214\/AJR.14.14173","DOI":"10.2214\/AJR.14.14173"},{"key":"9668_CR2","doi-asserted-by":"publisher","unstructured":"Ammari, S., Pitre-Champagnat, S., Dercle, L., Chouzenoux, E., Moalla, S., Reuze, S., ... & Bidault, F. (2021, January). Influence of Magnetic Field Strength on Magnetic Resonance Imaging Radiomics Features in Brain Imaging, an In Vitro and In Vivo Study. Frontiers in Oncology, 10, 541663. https:\/\/doi.org\/10.3389\/fonc.2020.541663. [2022-08-01] https:\/\/www.frontiersin.org\/articles\/10.3389\/fonc.2020.541663\/full","DOI":"10.3389\/fonc.2020.541663"},{"key":"9668_CR3","doi-asserted-by":"crossref","unstructured":"Balezeau, F., Eliat, P. -A., Cayamo, A. B., & Saint-Jalmes, H. (2011, October). Mapping of low flip angles in magnetic resonance.\u00a0Physics in Medicine and Biology, 56(20), 6635\u20136647.","DOI":"10.1088\/0031-9155\/56\/20\/008"},{"key":"9668_CR4","doi-asserted-by":"publisher","unstructured":"Bandettini, P. A. (2012, August). Twenty years of functional MRI: The science and the stories. NeuroImage, 62(2), 575\u2013588. https:\/\/doi.org\/10.1016\/j.neuroimage.2012.04.026. [2022-12-01] https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053811912004223","DOI":"10.1016\/j.neuroimage.2012.04.026"},{"key":"9668_CR5","volume-title":"Clinical MR spectroscopy: techniques and applications","author":"PB Barker","year":"2010","unstructured":"Barker, P. B., Bizzi, A., De Stefano, N., Lin, D. D., & Gullapalli, R. (2010). Clinical MR spectroscopy: techniques and applications. Cambridge University Press."},{"key":"9668_CR6","doi-asserted-by":"publisher","unstructured":"Bologna, M., Corino, V., & Mainardi, L. (2019, November). Technical Note: Virtual phantom analyses for preprocessing evaluation and detection of a robust feature set for MRI-radiomics of the brain. Medical Physics, 46(11), 5116\u20135123. https:\/\/doi.org\/10.1002\/mp.13834. [2022-08-02] https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mp.13834","DOI":"10.1002\/mp.13834"},{"key":"9668_CR7","doi-asserted-by":"publisher","unstructured":"Button, K. S., Ioannidis, J. P. A., Mokrysz, C., Nosek, B. A., Flint, J., Robinson, E. S. J., & Munaf\u00f3, M. R. (2013, May). Power failure: why small sample size undermines the reliability of neuroscience. Nature Reviews Neuroscience, 14(5), 365\u2013376. https:\/\/doi.org\/10.1038\/nrn3475. [2023-02-14] http:\/\/www.nature.com\/articles\/nrn3475","DOI":"10.1038\/nrn3475"},{"key":"9668_CR8","doi-asserted-by":"publisher","unstructured":"Carr\u00e9, A., Klausner, G., Edjlali, M., Lerousseau, M. , Briend-Diop, J., Sun, R. ... & Robert, C. (2020, December). Standardization of brain MR images across machines and protocols: bridging the gap for MRI-based radiomics. Scientific Reports, 10(1), 12340. https:\/\/doi.org\/10.1038\/s41598-020-69298-z. [2022-08-02] http:\/\/www.nature.com\/articles\/s41598-020-69298-z","DOI":"10.1038\/s41598-020-69298-z"},{"key":"9668_CR9","doi-asserted-by":"crossref","unstructured":"Casey, B., Cannonier, T., Conley, M. I., Cohen, A. O., Barch, D. M., Heitzeg, M. M., ... & Dale, A. M. (2018, August). The Adolescent Brain Cognitive Development (ABCD) study: Imaging acquisition across 21 sites. Developmental Cognitive Neuroscience, 32, 43\u201354.","DOI":"10.1016\/j.dcn.2018.03.001"},{"key":"9668_CR10","doi-asserted-by":"publisher","unstructured":"Chen, J. E., & Glover, G. H. (2015, Sep). Functional magnetic resonance imaging methods. Neuropsychology Review, 25(3), 289-313. https:\/\/doi.org\/10.1007\/s11065-015-9294-9","DOI":"10.1007\/s11065-015-9294-9"},{"key":"9668_CR11","doi-asserted-by":"publisher","unstructured":"Chirra, P., Leo, P., Yim, M., Bloch, B. N., Rastinehad, A. R., Purysko, A., ... & Viswanath, S. E. (2019, June). Multisite evaluation of radiomic feature reproducibility and discriminability for identifying peripheral zone prostate tumors on MRI. Journal of Medical Imaging, 6(02), 1. https:\/\/doi.org\/10.1117\/1.JMI.6.2.024502. [2022-08-02] https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-medical-imaging\/volume-6\/issue-02\/024502\/Multisite-evaluation-of-radiomic-feature-reproducibility-and-discriminability-for-identifying\/10.1117\/1.JMI.6.2.024502.full","DOI":"10.1117\/1.JMI.6.2.024502"},{"key":"9668_CR12","doi-asserted-by":"publisher","unstructured":"Clark, K., Vendt, B., Smith, K., Freymann, J., Kirby, J., Koppel, P., ... & Prior, F. (2013, December). The Cancer Imaging Archive (TCIA): Maintaining and Operating a Public Information Repository. Journal of Digital Imaging, 26(6), 1045\u20131057. https:\/\/doi.org\/10.1007\/s10278-013-9622-7. [2022-12-05] http:\/\/link.springer.com\/10.1007\/s10278-013-9622-7","DOI":"10.1007\/s10278-013-9622-7"},{"key":"9668_CR13","doi-asserted-by":"publisher","unstructured":"Clement, P., Castellaro, M., Okell, T. W., Thomas, D. L., Vandemaele, P., Elgayar, S., ... & Mutsaerts, H. J. M. M. (2022, Sep). Asl-bids, the brain imaging data structure extension for arterial spin labeling. Scientific Data, 9(11), 543. https:\/\/doi.org\/10.1038\/s41597-022-01615-9","DOI":"10.1038\/s41597-022-01615-9"},{"key":"9668_CR14","doi-asserted-by":"publisher","unstructured":"Covitz, S., Tapera, T. M., Adebimpe, A., Alexander-Bloch, A. F., Bertolero, M. A., Feczko, E., ... & Satterthwaite, T. D. (2022, Nov). Curation of bids (cubids): A workflow and software package for streamlining reproducible curation of large bids datasets. NeuroImage, 263, 119609. https:\/\/doi.org\/10.1016\/j.neuroimage.2022.119609","DOI":"10.1016\/j.neuroimage.2022.119609"},{"key":"9668_CR15","doi-asserted-by":"publisher","unstructured":"Esteban, O., Birman, D., Schaer, M., Koyejo, O. O., Poldrack, R. A., & Gorgolewski, K. J. (2017, September). Mriqc: Advancing the automatic prediction of image quality in mri from unseen sites. PLOS ONE, 12(9), e0184661. https:\/\/doi.org\/10.1371\/journal.pone.0184661","DOI":"10.1371\/journal.pone.0184661"},{"key":"9668_CR16","doi-asserted-by":"crossref","unstructured":"Feczko, E., Conan, G., Marek, S., Tervo-Clemmens, B., Cordova, M., Doyle, O., ... & others. (2021). Adolescent brain cognitive development (abcd) community mri collection and utilities. BioRxiv, 2021\u201307.","DOI":"10.1101\/2021.07.09.451638"},{"key":"9668_CR17","doi-asserted-by":"publisher","unstructured":"Feinberg, D. A., & Setsompop, K. (2013, Apr). Ultra-fast mri of the human brain with simultaneous multi-slice imaging. Journal of Magnetic Resonance, 229, 90\u2013100. https:\/\/doi.org\/10.1016\/j.jmr.2013.02.002","DOI":"10.1016\/j.jmr.2013.02.002"},{"key":"9668_CR18","doi-asserted-by":"crossref","unstructured":"Fortin, J. -P., Cullen, N., Sheline, Y. I., Taylor, W. D., Aselcioglu, I., Cook, P. A., ... & Shinohara, R. T. (2018, February). Harmonization of cortical thickness measurements across scanners and sites. NeuroImage, 167, 104\u2013120.","DOI":"10.1016\/j.neuroimage.2017.11.024"},{"key":"9668_CR19","doi-asserted-by":"publisher","unstructured":"Friedman, L., Stern, H., Brown, G. G., Mathalon, D. H., Turner, J., Glover, G. H., ... & Potkin, S.G. (2008, August). Test-retest and between-site reliability in a multicenter fMRI study. Human Brain Mapping, 29(8), 958\u2013972. https:\/\/doi.org\/10.1002\/hbm.20440. [2022-08-07]. https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/hbm.20440","DOI":"10.1002\/hbm.20440"},{"key":"9668_CR20","doi-asserted-by":"publisher","unstructured":"Geirhos, R., Jacobsen, J. -H., Michaelis, C., Zemel, R., Brendel, W., Bethge, M., & Wichmann, F. A. (2020, Nov) Shortcut learning in deep neural networks. Nature Machine Intelligence, 2(1111), 665\u2013673. https:\/\/doi.org\/10.1038\/s42256-020-00257-z","DOI":"10.1038\/s42256-020-00257-z"},{"key":"9668_CR21","doi-asserted-by":"publisher","unstructured":"George, A., Kuzniecky, R., Rusinek, H., Pardoe, H. R. & for the Human Epilepsy Project Investigators. (2020, January). Standardized Brain MRI Acquisition Protocols Improve Statistical Power in Multicenter Quantitative Morphometry Studies. Journal of Neuroimaging, 30(1), 126\u2013133. https:\/\/doi.org\/10.1111\/jon.12673. [2022-08-07] https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/jon.12673","DOI":"10.1111\/jon.12673"},{"key":"9668_CR22","doi-asserted-by":"publisher","unstructured":"Glen, D. R., Taylor, P. A., Buchsbaum, B. R., Cox, R. W., & Reynolds, R. C. (2020, May). Beware (Surprisingly Common) Left-Right Flips in Your MRI Data: An Efficient and Robust Method to Check MRI Dataset Consistency Using AFNI. Frontiers in Neuroinformatics, 14, 18. https:\/\/doi.org\/10.3389\/fninf.2020.00018. [2023-02-02]. https:\/\/www.frontiersin.org\/article\/10.3389\/fninf.2020.00018\/full","DOI":"10.3389\/fninf.2020.00018"},{"key":"9668_CR23","doi-asserted-by":"publisher","unstructured":"Gold, G. E., Han, E., Stainsby, J., Wright, G., Brittain, J. & Beaulieu, C. (2004, August). Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast. American Journal of Roentgenology, 183(2), 343\u2013351. https:\/\/doi.org\/10.2214\/ajr.183.2.1830343. [2022-08-11]. https:\/\/www.ajronline.org\/doi\/10.2214\/ajr.183.2.1830343","DOI":"10.2214\/ajr.183.2.1830343"},{"key":"9668_CR24","doi-asserted-by":"publisher","unstructured":"Gonzalez-Castillo, J., Roopchansingh, V., Bandettini, P., & Bodurka, J. (2011, February). Physiological noise effects on the flip angle selection in BOLD fMRI. NeuroImage, 54(4), 2764\u20132778. https:\/\/doi.org\/10.1016\/j.neuroimage.2010.11.020. [2023-02-23] https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053811910014503","DOI":"10.1016\/j.neuroimage.2010.11.020"},{"key":"9668_CR25","doi-asserted-by":"crossref","unstructured":"Gouttard, S., Styner, M., Prastawa, M., Piven, J., & Gerig, G. (2008, September). Assessment of Reliability of Multi-site Neuroimaging Via Traveling Phantom Study. Springer, 5242, 263\u2013270.","DOI":"10.1007\/978-3-540-85990-1_32"},{"key":"9668_CR26","first-page":"3","volume":"2","author":"J Graessner","year":"2013","unstructured":"Graessner, J. (2013). Bandwidth in mri. Magnetom Flash, 2, 3\u20138.","journal-title":"Bandwidth in mri. Magnetom Flash"},{"key":"9668_CR27","doi-asserted-by":"publisher","unstructured":"Gruetter, R. (1993, June). Automatic, localizedin Vivo adjustment of all first-and second-order shim coils. Magnetic Resonance in Medicine, 29(6), 804\u2013811. https:\/\/doi.org\/10.1002\/mrm.1910290613. [2022-12-06]. https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.1910290613","DOI":"10.1002\/mrm.1910290613"},{"key":"9668_CR28","doi-asserted-by":"publisher","unstructured":"Inglis, B. (2015). A checklist for fMRI acquisition methods reporting in the literature. The Winnower. https:\/\/doi.org\/10.15200\/winn.143191.17127. [2023-04-19] https:\/\/thewinnower.com\/papers\/a-checklist-for-fmri-acquisition-methods-reporting-in-the-literature","DOI":"10.15200\/winn.143191.17127"},{"key":"9668_CR29","doi-asserted-by":"publisher","unstructured":"Irfanoglu, M. O., Walker, L., Sarlls, J., Marenco, S., & Pierpaoli, C. (2012, May). Effects of image distortions originating from susceptibility variations and concomitant fields on diffusion MRI tractography results. NeuroImage, 61(1), 275\u2013288. https:\/\/doi.org\/10.1016\/j.neuroimage.2012.02.054. [2022-08-12] https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053811912002327","DOI":"10.1016\/j.neuroimage.2012.02.054"},{"key":"9668_CR30","doi-asserted-by":"publisher","unstructured":"Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., ... & ADNI Study. (2008, April). The Alzheimer\u2019s disease neuroimaging initiative (ADNI): MRI methods. Journal of Magnetic Resonance Imaging, 27(4), 685\u2013691. https:\/\/doi.org\/10.1002\/jmri.21049. [2022-08-07] https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.21049","DOI":"10.1002\/jmri.21049"},{"key":"9668_CR31","unstructured":"Jernigan, T. L. (2017, January). Adolescent Brain Cognitive Development Study (ABCD). https:\/\/nda.nih.gov\/edit_collection.html?id=2573"},{"key":"9668_CR32","doi-asserted-by":"crossref","unstructured":"Jezzard, P. (2012, August). Correction of geometric distortion in fMRI data. NeuroImage, 62(2), 648\u2013651.","DOI":"10.1016\/j.neuroimage.2011.09.010"},{"key":"9668_CR33","doi-asserted-by":"publisher","unstructured":"Jones, D. K., & Cercignani, M. (2010, September). Twenty-five pitfalls in the analysis of diffusion MRI data. NMR in Biomedicine, 23(7), 803\u2013820. https:\/\/doi.org\/10.1002\/nbm.1543. [2022-08-12] https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/nbm.1543","DOI":"10.1002\/nbm.1543"},{"key":"9668_CR34","doi-asserted-by":"publisher","unstructured":"Jovicich, J., Czanner, S., Greve, D., Haley, E., van\u00a0der Kouwe, A., Gollub, R., ... & Dale, A. (2006, April). Reliability in multi-site structural MRI studies: Effects of gradient non-linearity correction on phantom and human data. NeuroImage, 30(2), 436\u2013443. https:\/\/doi.org\/10.1016\/j.neuroimage.2005.09.046. [2022-08-07] https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053811905007299","DOI":"10.1016\/j.neuroimage.2005.09.046"},{"key":"9668_CR35","doi-asserted-by":"publisher","unstructured":"Jovicich, J., Czanner, S., Han, X., Salat, D., van\u00a0der Kouwe, A., Quinn, B., ... & Blacker, D. (2009, May). MRI-derived measurements of human subcortical, ventricular and intracranial brain volumes: Reliability effects of scan sessions, acquisition sequences, data analyses, scanner upgrade, scanner vendors and field strengths. NeuroImage, 46(1), 177\u2013192. https:\/\/doi.org\/10.1016\/j.neuroimage.2009.02.010. [2022-11-27] https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053811909001505","DOI":"10.1016\/j.neuroimage.2009.02.010"},{"key":"9668_CR36","doi-asserted-by":"publisher","unstructured":"Kennis, M., van Rooij, S., Kahn, R., Geuze, E., & Leemans, A. (2016). Choosing the polarity of the phase-encoding direction in diffusion MRI: Does it matter for group analysis? NeuroImage: Clinical, 11, 539\u2013547. https:\/\/doi.org\/10.1016\/j.nicl.2016.03.022. [2022-08-12] https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2213158216300638","DOI":"10.1016\/j.nicl.2016.03.022"},{"issue":"3","key":"9668_CR37","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1002\/jmri.20683","volume":"24","author":"D Le Bihan","year":"2006","unstructured":"Le Bihan, D., Poupon, C., Amadon, A., & Lethimonnier, F. (2006). September) Artifacts and pitfalls in diffusion MRI. Journal of Magnetic Resonance Imaging, 24(3), 478\u2013488.","journal-title":"Journal of Magnetic Resonance Imaging"},{"key":"9668_CR38","doi-asserted-by":"publisher","unstructured":"Li, Y., Ammari, S., Balleyguier, C., Lassau, N., & Chouzenoux, E. (2021, June). Impact of Preprocessing and Harmonization Methods on the Removal of Scanner Effects in Brain MRI Radiomic Features. Cancers, 13(12), 3000. https:\/\/doi.org\/10.3390\/cancers13123000. [2022-08-11] https:\/\/www.mdpi.com\/2072-6694\/13\/12\/3000","DOI":"10.3390\/cancers13123000"},{"key":"9668_CR39","volume-title":"Principles of functional Magnetic Resonance Imaging","author":"MA Lindquist","year":"2015","unstructured":"Lindquist, M. A., & Wager, T. D. (2015). Principles of functional Magnetic Resonance Imaging. London: CRC Press."},{"key":"9668_CR40","doi-asserted-by":"publisher","unstructured":"Lutterbey, G., Wattjes, M. P., Kandyba, J., Harzheim, M., Falkenhausen, M. V., Morakkabati, N. , ... & Gieseke, J. (2007, August). Clinical evaluation of a speed optimized T$$_{2}$$ weighted fast spin echo sequence at 3.0 T using variable flip angle refocusing, half-Fourier acquisition and parallel imaging. The British Journal of Radiology, 80(956), 668\u2013673. https:\/\/doi.org\/10.1259\/bjr\/88996134. [2022-08-12] http:\/\/www.birpublications.org\/doi\/10.1259\/bjr\/88996134","DOI":"10.1259\/bjr\/88996134"},{"key":"9668_CR41","doi-asserted-by":"publisher","unstructured":"Mali, S. A., Ibrahim, A., Woodruff, H. C., Andrearczyk, V., M\u00fcller, H., Primakov, S., ... & Lambin, P. (2021, August). Making radiomics more reproducible across scanner and imaging protocol variations: A review of harmonization methods. Journal of Personalized Medicine, 11(9), 842. https:\/\/doi.org\/10.3390\/jpm11090842","DOI":"10.3390\/jpm11090842"},{"key":"9668_CR42","doi-asserted-by":"publisher","unstructured":"Markiewicz, C. J., Gorgolewski, K. J., Feingold, F., Blair, R., Halchenko, Y. O., Miller, E., ... & Poldrack, R. (2021, Oct). The openneuro resource for sharing of neuroscience data. eLife, 10, e71774. https:\/\/doi.org\/10.7554\/eLife.71774.","DOI":"10.7554\/eLife.71774"},{"key":"9668_CR43","unstructured":"Mason, D., Scaramallion, Mrbean-Bremen, Rhaxton, Suever, J., Vanessasaurus, ... & Wada, M. (2022, November). pydicom\/pydicom: pydicom 2.3.1. Zenodo. [2023-02-21] https:\/\/zenodo.org\/record\/7319790"},{"key":"9668_CR44","doi-asserted-by":"publisher","unstructured":"Mayerhoefer, M. E., Szomolanyi, P., Jirak, D., Materka, A., & Trattnig, S. (2009, March). Effects of MRI acquisition parameter variations and protocol heterogeneity on the results of texture analysis and pattern discrimination: An application-oriented study: Effects of MRI acquisition parameters on texture analysis. Medical Physics, 36(4), 1236\u20131243. https:\/\/doi.org\/10.1118\/1.3081408. [2022-08-01] http:\/\/doi.wiley.com\/10.1118\/1.3081408","DOI":"10.1118\/1.3081408"},{"key":"9668_CR45","doi-asserted-by":"publisher","unstructured":"Mugler, J. P. (2011, May). Optimized three-dimensional fast-spin-echo mri. ISMRM Annual Meeting and Exhibition, 39(4), 745\u2013767. https:\/\/doi.org\/10.1002\/jmri.24542","DOI":"10.1002\/jmri.24542"},{"key":"9668_CR46","unstructured":"Okada, T., Kanagaki, M., Yamamoto, A., Sakamoto, R., Kasahara, S., Morimoto, E., ... & Togashi, K. A. (2011, April). Which to choose for volumetry: MPRAGE or SPACE?. 2011 ISMRM Annual Meeting and Exhibition (ISMRM). Quebec, CanadaISMRM. [2022-05-13] https:\/\/ieeexplore.ieee.org\/document\/9434081\/"},{"key":"9668_CR47","doi-asserted-by":"publisher","unstructured":"Pardoe, H., Pell, G. S., Abbott, D. F., Berg, A. T., & Jackson, G. D. (2008, August). Multi-site voxel-based morphometry: Methods and a feasibility demonstration with childhood absence epilepsy. NeuroImage, 42(2), 611\u2013616. https:\/\/doi.org\/10.1016\/j.neuroimage.2008.05.007. [2022-08-07] https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053811908006174","DOI":"10.1016\/j.neuroimage.2008.05.007"},{"key":"9668_CR48","doi-asserted-by":"publisher","unstructured":"Pardoe, G., et al. (2009, January). Multisite Collaborations and Large Databases in Psychiatric Neuroimaging: Advantages, Problems, and Challenges. Schizophrenia Bulletin, 35(1), 1\u20132. https:\/\/doi.org\/10.1093\/schbul\/sbn166. [2022-08-07] https:\/\/academic.oup.com\/schizophreniabulletin\/article-lookup\/doi\/10.1093\/schbul\/sbn166","DOI":"10.1093\/schbul\/sbn166"},{"key":"9668_CR49","unstructured":"Pedano, N., Flanders, A. E., Scarpace, L., Mikkelsen, T., Eschbacher, J. M., Hermes, B., ... & Ostrom, Q. (2016). The Cancer Genome Atlas Low Grade Glioma Collection (TCGA-LGG). The Cancer Imaging Archive. [2022-12-05] https:\/\/wiki.cancerimagingarchive.net\/x\/BANR. Version Number: 3 Type: dataset"},{"key":"9668_CR50","doi-asserted-by":"publisher","unstructured":"Petersen, R. C., Aisen, P. S., Beckett, L. A., Donohue, M. C., Gamst, A. C., Harvey, D. J., ... & Weiner, M. W. (2010, January). Alzheimer\u2019s Disease Neuroimaging Initiative (ADNI): Clinical characterization. Neurology, 74(3), 201\u2013209. https:\/\/doi.org\/10.1212\/WNL.0b013e3181cb3e25. [2022-08-04] https:\/\/www.neurology.org\/lookup\/doi\/10.1212\/WNL.0b013e3181cb3e25","DOI":"10.1212\/WNL.0b013e3181cb3e25"},{"key":"9668_CR51","doi-asserted-by":"publisher","unstructured":"Poldrack, R. A., Fletcher, P. C., Henson, R. N., Worsley, K. J., Brett, M., & Nichols, T. E. (2008, Apr). Guidelines for reporting an fmri study. NeuroImage, 40(2), 409\u2013414. https:\/\/doi.org\/10.1016\/j.neuroimage.2007.11.048","DOI":"10.1016\/j.neuroimage.2007.11.048"},{"key":"9668_CR52","doi-asserted-by":"publisher","unstructured":"Provins, C., MacNicol, E., Seeley, S. H., Hagmann, P., & Esteban, O. (2023, January). Quality control in functional MRI studies with MRIQC and fMRIPrep. Frontiers in Neuroimaging, 1, 1073734. https:\/\/doi.org\/10.3389\/fnimg.2022.1073734. [2023-02-02] https:\/\/www.frontiersin.org\/articles\/10.3389\/fnimg.2022.1073734\/full","DOI":"10.3389\/fnimg.2022.1073734"},{"key":"9668_CR53","unstructured":"Raamana, P. (2018, May). Let\u2019s focus our neuroinformatics community efforts in Python and on software validation. https:\/\/crossinvalidation.com\/2018\/05\/03\/lets-focus-our-neuroinformatics-community-efforts-in-python-and-on-software-validation\/"},{"key":"9668_CR54","doi-asserted-by":"publisher","unstructured":"Reynolds, R. C., Taylor, P. A., & Glen, D. R. (2023, January). Quality control practices in FMRI analysis: Philosophy, methods and examples using AFNI. Frontiers in Neuroscience, 16, 1073800. https:\/\/doi.org\/10.3389\/fnins.2022.1073800. [2023-02-02] https:\/\/www.frontiersin.org\/articles\/10.3389\/fnins.2022.1073800\/full","DOI":"10.3389\/fnins.2022.1073800"},{"key":"9668_CR55","doi-asserted-by":"publisher","unstructured":"Rutt, B. K., & Lee, D. H. (1996, January). The impact of field strength on image quality in MRI. Journal of Magnetic Resonance Imaging, 6(1), 57\u201362. https:\/\/doi.org\/10.1002\/jmri.1880060111. [2022-08-12] urlhttps:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.1880060111","DOI":"10.1002\/jmri.1880060111"},{"key":"9668_CR56","doi-asserted-by":"publisher","unstructured":"Sachs, P. B., Hunt, K., Mansoubi, F., & Borgstede, J. (2017, February). CT and MR Protocol Standardization Across a Large Health System: Providing a Consistent Radiologist, Patient, and Referring Provider Experience. Journal of Digital Imaging, 30(1), 11\u201316. https:\/\/doi.org\/10.1007\/s10278-016-9895-8. [2024-03-01] http:\/\/link.springer.com\/10.1007\/s10278-016-9895-8","DOI":"10.1007\/s10278-016-9895-8"},{"key":"9668_CR57","doi-asserted-by":"publisher","unstructured":"Sandmann, C., Hodneland, E., & Modersitzki, J. (2016, December). A practical guideline for T$$_{1}$$ reconstruction from various flip angles in MRI. Journal of Algorithms & Computational Technology, 10(4), 213\u2013223. https:\/\/doi.org\/10.1177\/1748301816656288. [2022-08-12] http:\/\/journals.sagepub.com\/doi\/10.1177\/1748301816656288","DOI":"10.1177\/1748301816656288"},{"key":"9668_CR58","unstructured":"Scarpace, L., Flanders, A. E., Jain, R., Mikkelsen, T., & Andrews, D. W. (2019). Data From REMBRANDT. The Cancer Imaging Archive. [2022-12-05] https:\/\/wiki.cancerimagingarchive.net\/display\/Public\/REMBRANDT. Version Number: 2 Type: dataset."},{"key":"9668_CR59","unstructured":"Scarpace, L., Mikkelsen, T., Cha, S., Rao, S., Tekchandani, S., Gutman, D., ... & Pierce, L. J. (2016). The Cancer Genome Atlas Glioblastoma Multiforme Collection (TCGA-GBM). The Cancer Imaging Archive. [2022-12-05] https:\/\/wiki.cancerimagingarchive.net\/x\/sgAe. Version Number: 4 Type: dataset."},{"key":"9668_CR60","doi-asserted-by":"publisher","unstructured":"Scheffler, M., Maturana, E., Salomir, R., Haller, S., & K\u00f6vari, E. (2018, October). Air bubble artifact reduction in post-mortem whole-brain mri: the influence of receiver bandwidth. Neuroradiology, 60(10), 1089-1092. https:\/\/doi.org\/10.1007\/s00234-018-2071-8","DOI":"10.1007\/s00234-018-2071-8"},{"key":"9668_CR61","doi-asserted-by":"publisher","unstructured":"Schlett, C. L., Hendel, T., Hirsch, J., Weckbach, S., Caspers, S., Schulz-Menger, J., ... & Bamberg, F. (2016, Apr) Quantitative, organ-specific interscanner and intrascanner variability for 3 t whole-body magnetic resonance imaging in a multicenter, multivendor study. Investigative Radiology, 51(4), 255-265. https:\/\/doi.org\/10.1097\/RLI.0000000000000237.","DOI":"10.1097\/RLI.0000000000000237"},{"key":"9668_CR62","doi-asserted-by":"publisher","unstructured":"Schnack, H. G., van Haren, N. E., Hulshoff\u00a0Pol, H. E., Picchioni, M., Weisbrod, M., Sauer, H., ... & Kahn, R. S. (2004, August). Reliability of brain volumes from multicenter MRI acquisition: A calibration study. Human Brain Mapping, 22(4), 312\u2013320. https:\/\/doi.org\/10.1002\/hbm.20040. [2022-08-07] https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/hbm.20040","DOI":"10.1002\/hbm.20040"},{"key":"9668_CR63","doi-asserted-by":"publisher","unstructured":"Schurink, N. W., van Kranen, S. R., Roberti, S., van Griethuysen, J. J. M., Bogveradze, N., Castagnoli, F., ... & Lambregts, D. M. J. (2022, March). Sources of variation in multicenter rectal MRI data and their effect on radiomics feature reproducibility. European Radiology, 32(3), 1506\u20131516. https:\/\/doi.org\/10.1007\/s00330-021-08251-8. [2022-08-11] https:\/\/link.springer.com\/10.1007\/s00330-021-08251-8","DOI":"10.1007\/s00330-021-08251-8"},{"key":"9668_CR64","doi-asserted-by":"publisher","unstructured":"Szczykutowicz, T. P., & Siegelman, J. (2015, August). On the same page-physicist and radiologist perspectives on protocol management and review. Journal of the American College of Radiology, 12(8), 808-814. https:\/\/doi.org\/10.1016\/j.jacr.2015.03.042","DOI":"10.1016\/j.jacr.2015.03.042"},{"key":"9668_CR65","doi-asserted-by":"publisher","unstructured":"Szucs, D., & Ioannidis, J. P. (2020, November). Sample size evolution in neuroimaging research: An evaluation of highly-cited studies (1990-2012) and of latest practices (2017-2018) in high-impact journals. NeuroImage, 221, 117164, https:\/\/doi.org\/10.1016\/j.neuroimage.2020.117164. [2023-02-14] https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1053811920306509","DOI":"10.1016\/j.neuroimage.2020.117164"},{"key":"9668_CR66","doi-asserted-by":"publisher","unstructured":"Taylor, P. A., Glen, D. R., Reynolds, R. C., Basavaraj, A., Moraczewski, D., & Etzel, J. A. (2023, May). Editorial: Demonstrating quality control (qc) procedures in fmri. Frontiers in Neuroscience, 17, 1205928. https:\/\/doi.org\/10.3389\/fnins.2023.1205928","DOI":"10.3389\/fnins.2023.1205928"},{"key":"9668_CR67","doi-asserted-by":"publisher","unstructured":"Tudela, R. , Mu\u00f1oz-Moreno, E. , L\u00f3pez-Gil, X., & Soria, G. (2017, January). Effects of Orientation and Anisometry of Magnetic Resonance Imaging Acquisitions on Diffusion Tensor Imaging and Structural Connectomes. PLOS ONE, 12(1), e0170703. https:\/\/doi.org\/10.1371\/journal.pone.0170703. [2022-08-12] https:\/\/dx.plos.org\/10.1371\/journal.pone.0170703","DOI":"10.1371\/journal.pone.0170703"},{"key":"9668_CR68","doi-asserted-by":"crossref","unstructured":"Van Essen, D. C., Smith, S. M., Barch, D. M., Behrens, T. E., Yacoub, E., & Ugurbil, K. (2013, October). The WU-Minn Human Connectome Project: An overview. NeuroImage, 80, 62\u201379.","DOI":"10.1016\/j.neuroimage.2013.05.041"},{"key":"9668_CR69","doi-asserted-by":"crossref","unstructured":"Wang, S., Peterson, D. J., Gatenby, J. C., Li, W., Grabowski, T. J., & Madhyastha, T. M. (2017). Evaluation of field map and nonlinear registration methods for correction of susceptibility artifacts in diffusion mri. Frontiers in Neuroinformatics, 11, https:\/\/www.frontiersin.org\/articles\/10.3389\/fninf.2017.00017","DOI":"10.3389\/fninf.2017.00017"},{"key":"9668_CR70","doi-asserted-by":"publisher","unstructured":"Wilkinson, M. D., Dumontier, M., Aalbersberg, I. J., Appleton, G., Axton, M., Baak, A., ... & Mons, B. (2016, March). The FAIR Guiding Principles for scientific data management and stewardship. Scientific Data, 3(1), 160018. https:\/\/doi.org\/10.1038\/sdata.2016.18. [2023-04-10] https:\/\/www.nature.com\/articles\/sdata201618","DOI":"10.1038\/sdata.2016.18"}],"container-title":["Neuroinformatics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12021-024-09668-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s12021-024-09668-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s12021-024-09668-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,16]],"date-time":"2024-08-16T08:23:11Z","timestamp":1723796591000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s12021-024-09668-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,11]]},"references-count":70,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024,7]]}},"alternative-id":["9668"],"URL":"https:\/\/doi.org\/10.1007\/s12021-024-09668-4","relation":{},"ISSN":["1559-0089"],"issn-type":[{"value":"1559-0089","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,11]]},"assertion":[{"value":"4 May 2024","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2024","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval and Consent to Participate"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Financial Interests"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}]}}