{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T18:20:24Z","timestamp":1770834024653,"version":"3.50.1"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2021,7,24]],"date-time":"2021-07-24T00:00:00Z","timestamp":1627084800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,7,24]],"date-time":"2021-07-24T00:00:00Z","timestamp":1627084800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Syst Assur Eng Manag"],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The purpose of this paper is to describe the design of a Hybrid Series Active Power Filter (HSeAPF) system to improve the quality of power on three-phase power distribution grids. The system controls are comprise of Pulse Width Modulation (PWM) based on the Synchronous Reference Frame (SRF) theory, and supported by Phase Locked Loop (PLL) for generating the switching pulses to control a Voltage Source Converter (VSC). The DC link voltage is controlled by Non-Linear Sliding Mode Control (SMC) for faster response and to ensure that it is maintained at a constant value. When this voltage is compared with Proportional Integral (PI), then the improvements made can be shown. The function of HSeAPF control is to eliminate voltage fluctuations, voltage swell\/sag, and prevent voltage\/current harmonics are produced by both non-linear loads and small inverters connected to the distribution network. A digital Phase Locked Loop that generates frequencies and an oscillating phase-locked output signal controls the voltage. The results from the simulation indicate that the HSeAPF can effectively suppress the dynamic and harmonic reactive power compensation system. Also, the distribution network has a low Total Harmonic Distortion (&lt;\u20095%), demonstrating that the designed system is efficient, which is an essential requirement when it comes to the IEEE-519 and IEC 61,000\u20133-6 standards.<\/jats:p>","DOI":"10.1007\/s13198-021-01185-w","type":"journal-article","created":{"date-parts":[[2021,7,24]],"date-time":"2021-07-24T13:02:51Z","timestamp":1627131771000},"page":"976-989","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Distribution system power quality compensation using a HSeAPF based on SRF and SMC features"],"prefix":"10.1007","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1369-3358","authenticated-orcid":false,"given":"Akram","family":"Qashou","sequence":"first","affiliation":[]},{"given":"Sufian","family":"Yousef","sequence":"additional","affiliation":[]},{"given":"Abdallah A.","family":"Smadi","sequence":"additional","affiliation":[]},{"given":"Amani A.","family":"AlOmari","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2021,7,24]]},"reference":[{"key":"1185_CR1","doi-asserted-by":"publisher","unstructured":"Altawil IA, Mahafzah KA, Smadi AA (2012) Hybrid active power filter based on diode clamped inverter and hysteresis band current controller, In: 2012 2nd International Conference on Advances in Computational Tools for Engineering Applications (ACTEA), Beirut, pp. 198\u2013203, https:\/\/doi.org\/10.1109\/ICTEA.2012.6462865.","DOI":"10.1109\/ICTEA.2012.6462865"},{"issue":"22","key":"1185_CR3","doi-asserted-by":"publisher","first-page":"4387","DOI":"10.3390\/en12224387","volume":"12","author":"HMK Al-Masri","year":"2019","unstructured":"Al-Masri HMK, Al-Quraan A, AbuElrub A, Ehsani M (2019) Optimal coordination of wind power and pumped hydro energy storage. Energies 12(22):4387","journal-title":"Energies"},{"key":"1185_CR4","doi-asserted-by":"crossref","unstructured":"Al-Soeidat M, Khawaldeh H, Aljarajreh H, Lu D (2018) A Compact Three-Port DC-DC Converter for Integrated PV-Battery System,and quot, In: 2018 IEEE International Power Electronics and Application Conference and Exposition (PEAC) Shenzhen 1 6","DOI":"10.1109\/PEAC.2018.8590624"},{"key":"1185_CR5","doi-asserted-by":"publisher","unstructured":"Allehyani M, Samkari H and Johnson BK, (2016) Modeling and simulation of the impacts of STATCOM control schemes on distance elements. North American Power Symposium (NAPS) Denver, CO 2016: 1- 6 https:\/\/doi.org\/10.1109\/NAPS.2016.7747905","DOI":"10.1109\/NAPS.2016.7747905"},{"issue":"1","key":"1185_CR6","doi-asserted-by":"publisher","first-page":"1309518","DOI":"10.1155\/2018\/1309518","volume":"2018","author":"SR Das","year":"2018","unstructured":"Das SR, Ray PK, Mohanty A (2018) Fuzzy sliding mode based series hybrid active power filter for power quality enhancement. Adv Fuzzy Syst 2018(1):1309518. https:\/\/doi.org\/10.1155\/2018\/1309518","journal-title":"Adv Fuzzy Syst"},{"key":"1185_CR7","doi-asserted-by":"crossref","unstructured":"Dash, Santanu Kumar, and Pravat Kumar Ray. (2018) Investigation on the performance of PV-UPQC under distorted current and voltage conditions. In\u00a02018 5th International Conference on Renewable Energy: Generation and Applications (ICREGA), pp. 305\u2013309. IEEE","DOI":"10.1109\/ICREGA.2018.8337610"},{"issue":"1","key":"1185_CR8","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1109\/TIA.2017.2754983","volume":"54","author":"S Devassy","year":"2017","unstructured":"Devassy S, Singh B (2017) Design and performance analysis of three-phase solar PV integrated UPQC. IEEE Trans Ind Appl 54(1):73\u201381","journal-title":"IEEE Trans Ind Appl"},{"key":"1185_CR2","unstructured":"Emin T, Akram Q, Nezihe Y (2013) Shunt active power filters based on diode clamped multilevel inverter and hysteresis band current Controller. Innovative Systems Design and Engineering, ISSN 2222\u20131727, 4(14)."},{"issue":"16","key":"1185_CR9","doi-asserted-by":"publisher","first-page":"3383","DOI":"10.3390\/app9163383","volume":"9","author":"J Fei","year":"2019","unstructured":"Fei J, Wang H, Cao Di (2019) Adaptive backstepping fractional fuzzy sliding mode control of active power filter. Appl Sci 9(16):3383","journal-title":"Appl Sci"},{"issue":"4","key":"1185_CR10","doi-asserted-by":"publisher","first-page":"3558","DOI":"10.1109\/TPEL.2019.2937936","volume":"35","author":"S Golestan","year":"2020","unstructured":"Golestan S, Guerrero JM, Vasquez JC, Abusorrah AM, Al-Turki Y (2020) All-pass-filter-based PLL systems: linear modeling, analysis, and comparative evaluation. IEEE Trans Power Electron 35(4):3558\u20133572","journal-title":"IEEE Trans Power Electron"},{"key":"1185_CR11","unstructured":"IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems, In:\u00a0IEEE Std 519\u20132014 (Revision of IEEE Std 519\u20131992)\u00a0, vol., no., pp.1\u201329, 11 June (2014)."},{"issue":"7","key":"1185_CR13","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1049\/iet-pel.2011.0300","volume":"5","author":"C-S Lam","year":"2012","unstructured":"Lam C-S, Wong M-C, Han Y-D (2012) Hysteresis current control of hybrid active power filters. IET Power Electron 5(7):1175\u20131187","journal-title":"IET Power Electron"},{"issue":"4","key":"1185_CR15","doi-asserted-by":"publisher","first-page":"3387","DOI":"10.1016\/j.aej.2018.02.002","volume":"57","author":"Y Mojtaba","year":"2018","unstructured":"Mojtaba Y, Edjtahed SH, Taher SA, (2018) A non-linear controller design for UPQC in distribution systems. Alex Eng J 57(4):3387\u20133404","journal-title":"Alex Eng J"},{"issue":"2","key":"1185_CR16","first-page":"689","volume":"81","author":"S Narayan","year":"2018","unstructured":"Narayan S, Lakshminarayana C (2018) Performance enhancement in active power filter (APF) by FPGA implementation. Int J Electr Comp Eng 81(2):689\u2013698","journal-title":"Int J Electr Comp Eng"},{"key":"1185_CR17","doi-asserted-by":"publisher","unstructured":"Patjoshi RK, Mahapatra K (2014) Non-linear sliding mode control with SRF based method of UPQC for power quality enhancement, In: 2014 9th International Conference on Industrial and Information Systems (ICIIS), pp. 1\u20136, https:\/\/doi.org\/10.1109\/ICIINFS.2014.7036539.","DOI":"10.1109\/ICIINFS.2014.7036539"},{"key":"1185_CR18","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1016\/j.ijepes.2018.02.042","volume":"100","author":"A Safa","year":"2018","unstructured":"Safa A et al (2018) A robust control algorithm for a multifunctional grid tied inverter to enhance the power quality of a microgrid under unbalanced conditions. Int J Electr Power Energy Syst 100:253\u2013264","journal-title":"Int J Electr Power Energy Syst"},{"key":"1185_CR19","doi-asserted-by":"crossref","DOI":"10.1002\/9781118922064","volume-title":"Power Quality: Problems and Mitigation Techniques","author":"B Singh","year":"2015","unstructured":"Singh B, Chandra A, Haddad KA (2015) Power Quality: Problems and Mitigation Techniques. Wiley, London"},{"key":"1185_CR20","doi-asserted-by":"crossref","unstructured":"Smadi AA, Hangtian L, Brian KJ (2019) Distribution system harmonic mitigation using a pv system with hybrid active filter features. In:\u00a02019 North American Power Symposium (NAPS), pp. 1\u20136. IEEE","DOI":"10.1109\/NAPS46351.2019.9000238"}],"container-title":["International Journal of System Assurance Engineering and Management"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13198-021-01185-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13198-021-01185-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13198-021-01185-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,6]],"date-time":"2023-11-06T12:21:15Z","timestamp":1699273275000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13198-021-01185-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,24]]},"references-count":18,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["1185"],"URL":"https:\/\/doi.org\/10.1007\/s13198-021-01185-w","relation":{},"ISSN":["0975-6809","0976-4348"],"issn-type":[{"value":"0975-6809","type":"print"},{"value":"0976-4348","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7,24]]},"assertion":[{"value":"26 March 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 June 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 June 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 July 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of Interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. All applicable international, national, and\/or institutional guidelines for the care and use of animals were followed.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}