{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T18:00:24Z","timestamp":1792864824434,"version":"4.5.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2024,3,22]],"date-time":"2024-03-22T00:00:00Z","timestamp":1711065600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,3,22]],"date-time":"2024-03-22T00:00:00Z","timestamp":1711065600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"SERB-DST, India","award":["SRG\/2019\/001888"],"award-info":[{"award-number":["SRG\/2019\/001888"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Syst Assur Eng Manag"],"published-print":{"date-parts":[[2024,6]]},"DOI":"10.1007\/s13198-024-02289-9","type":"journal-article","created":{"date-parts":[[2024,3,22]],"date-time":"2024-03-22T04:16:22Z","timestamp":1711080982000},"page":"2677-2688","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Power quality enhancement in utility grid using distributed energy resources integrated BBC-VSI based DSTATCOM"],"prefix":"10.1007","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9934-0184","authenticated-orcid":false,"given":"Jogeswara","family":"Sabat","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mrutyunjaya","family":"Mangaraj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajit Kumar","family":"Barisal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,3,22]]},"reference":[{"issue":"5","key":"2289_CR1","doi-asserted-by":"publisher","first-page":"1598","DOI":"10.1109\/TNNLS.2017.2677961","volume":"29","author":"RK Agarwal","year":"2018","unstructured":"Agarwal RK, Hussain I, Singh B (2018) Application of LMS-based NN structure for power quality enhancement in a distribution network under abnormal conditions. IEEE Trans Neural Netw Learning Syst 29(5):1598\u20131607","journal-title":"IEEE Trans Neural Netw Learning Syst"},{"key":"2289_CR2","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.1007\/s13198-021-01392-5","volume":"13","author":"M Ahmad","year":"2022","unstructured":"Ahmad M, Kirmani S (2022) Simulation and analysis of a grid integrated distribution system based on LMS algorithm for hybrid types of load. Int J Syst Assur Eng Manag 13:1082\u20131092. https:\/\/doi.org\/10.1007\/s13198-021-01392-5","journal-title":"Int J Syst Assur Eng Manag"},{"issue":"2","key":"2289_CR3","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1109\/JESTPE.2014.2359205","volume":"3","author":"MM Baggu","year":"2015","unstructured":"Baggu MM, Chowdhury BH, Kimball JW (2015) Comparison of advanced control techniques for grid side converter of doubly-fed induction generator back-to-back converters to improve power quality performance during unbalanced voltage dips. IEEE J Emerg Sel Top Power Electr 3(2):516\u2013524","journal-title":"IEEE J Emerg Sel Top Power Electr"},{"issue":"1","key":"2289_CR4","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1109\/JESTPE.2015.2507203","volume":"4","author":"RN Beres","year":"2016","unstructured":"Beres RN, Wang X, Liserre M, Blaabjerg F, Bak CL (2016) A review of passive filters for three-phase grid-connected voltage-source converters. IEEE J Emerg Sel Top Power Electron 4(1):54\u201369","journal-title":"IEEE J Emerg Sel Top Power Electron"},{"key":"2289_CR5","doi-asserted-by":"publisher","first-page":"0378","DOI":"10.1016\/j.epsr.2019.106014","volume":"177","author":"M B\u00fcy\u00fck","year":"2019","unstructured":"B\u00fcy\u00fck M, \u0130nci M, Tan A, T\u00fcmay M (2019) Improved instantaneous power theory based current harmonic extraction for unbalanced electrical grid conditions. Electr Power Syst Res 177:0378\u20137796. https:\/\/doi.org\/10.1016\/j.epsr.2019.106014","journal-title":"Electr Power Syst Res"},{"issue":"3","key":"2289_CR6","doi-asserted-by":"publisher","first-page":"1994","DOI":"10.1109\/TIE.2020.2972467","volume":"68","author":"M Car","year":"2021","unstructured":"Car M, Le\u0161i\u0107 V, Va\u0161ak M (2021) Cascaded control of back-to-back converter DC link voltage robust to grid parameters variation. IEEE Trans Industr Electron 68(3):1994\u20132004","journal-title":"IEEE Trans Industr Electron"},{"key":"2289_CR7","doi-asserted-by":"publisher","DOI":"10.1007\/s13198-022-01826-8","author":"A Chebabhi","year":"2022","unstructured":"Chebabhi A, Al-dwa A, Barkat S et al (2022) Backstepping control of a grid-connected four-leg PWM rectifier under both balanced and unbalanced grid conditions. Int J Syst Assur Eng Manag. https:\/\/doi.org\/10.1007\/s13198-022-01826-8","journal-title":"Int J Syst Assur Eng Manag"},{"issue":"1","key":"2289_CR8","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1109\/TII.2020.2986308","volume":"17","author":"SK Dash","year":"2021","unstructured":"Dash SK, Ray PK (2021) A new PV-open-UPQC configuration for voltage sensitive loads utilizing novel adaptive controllers. IEEE Trans Industr Inf 17(1):421\u2013429","journal-title":"IEEE Trans Industr Inf"},{"issue":"3","key":"2289_CR9","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1109\/TPEL.2008.2008441","volume":"24","author":"N Flourentzou","year":"2009","unstructured":"Flourentzou N, Agelidis VG, Demetriades GD (2009) Vsc-based hvdc power transmission systems: an overview. IEEE Trans on Power Electronics 24(3):592\u2013602","journal-title":"IEEE Trans on Power Electronics"},{"issue":"12","key":"2289_CR10","doi-asserted-by":"publisher","first-page":"4487","DOI":"10.1109\/TIE.2011.2179278","volume":"59","author":"T Friedli","year":"2012","unstructured":"Friedli T, Kolar JW, Rodriguez J, Wheeler PW (2012) Comparative evaluation of three-phase ac-ac matrix converter and voltage dc-link back-to-back converter systems. IEEE Trans on Ind Electr 59(12):4487\u20134510","journal-title":"IEEE Trans on Ind Electr"},{"issue":"21","key":"2289_CR11","first-page":"42","volume":"5","author":"S Ganesan","year":"2023","unstructured":"Ganesan S, David PW, Murugesan P, Balachandran PK (2023) Solar photovoltaic system performance improvement using a new fault identification technique. Electr Power Compon Syst 5(21):42\u201354","journal-title":"Electr Power Compon Syst"},{"key":"2289_CR12","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1007\/s00202-016-0422-1","volume":"99","author":"M \u0130nci","year":"2017","unstructured":"\u0130nci M, Bayindir K\u00c7, mT\u00fcmay, M. (2017) The performance improvement of dynamic voltage restorer based on bidirectional dc\u2013dc converter. Electr Eng 99:285\u2013300. https:\/\/doi.org\/10.1007\/s00202-016-0422-1","journal-title":"Electr Eng"},{"issue":"6","key":"2289_CR13","doi-asserted-by":"publisher","first-page":"7176","DOI":"10.1109\/TIA.2020.3025520","volume":"56","author":"VN Jayasankar","year":"2020","unstructured":"Jayasankar VN, Vinatha U (2020) Backstepping controller with dual self-tuning filter for single-phase shunt active power filters under distorted grid voltage condition. IEEE Trans Ind Appl 56(6):7176\u20137184. https:\/\/doi.org\/10.1109\/TIA.2020.3025520","journal-title":"IEEE Trans Ind Appl"},{"key":"2289_CR14","doi-asserted-by":"publisher","unstructured":"Kalyan CN, Goud BS, Kishan H, Ramineni P, Kumar BP & Anil Kumar T (2022) Donkey and smuggler optimization algorithm-based degree of freedom controller for stability of two area power system with AC-DC links. In: 2022 IEEE 7th international conference on recent advances and innovations in engineering (ICRAIE), Mangalore, India, 461\u2013466, https:\/\/doi.org\/10.1109\/ICRAIE56454.2022.10054318","DOI":"10.1109\/ICRAIE56454.2022.10054318"},{"key":"2289_CR15","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/j.ijepes.2014.04.018","volume":"62","author":"P Karuppanan","year":"2014","unstructured":"Karuppanan P, Mahapatra KK (2014) Active harmonic current compensation to enhance power quality. Int J Elect Power Energy Syst 62:144\u2013151","journal-title":"Int J Elect Power Energy Syst"},{"key":"2289_CR16","doi-asserted-by":"publisher","unstructured":"Koroglu T et al. (2015) Performance evaluation of a new hybrid unified power quality conditioner (HUPQC). In: 2015 IEEE 6th international symposium on power electronics for distributed generation systems (PEDG). 1\u20136. https:\/\/doi.org\/10.1109\/PEDG.2015.7223023","DOI":"10.1109\/PEDG.2015.7223023"},{"issue":"6","key":"2289_CR17","doi-asserted-by":"publisher","first-page":"3732","DOI":"10.1109\/TII.2019.2901516","volume":"15","author":"N Kumar","year":"2019","unstructured":"Kumar N, Singh B, Panigrahi BK (2019) PNKLMF-based neural network control and learning-based HC MPPT technique for multiobjective grid integrated solar PV based distributed generating system. IEEE Trans Industr Inf 15(6):3732\u20133742","journal-title":"IEEE Trans Industr Inf"},{"issue":"2","key":"2289_CR18","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1109\/TII.2017.2766890","volume":"14","author":"B Liu","year":"2018","unstructured":"Liu B, Wei Q, Zou C, Duan S (2018) Stability analysis of LCL-type grid-connected inverter under single-loop inverter-side current control with capacitor voltage feedforward. IEEE Trans Ind Inform 14(2):691\u2013702","journal-title":"IEEE Trans Ind Inform"},{"issue":"12","key":"2289_CR19","doi-asserted-by":"publisher","first-page":"1617","DOI":"10.1049\/iet-pel.2017.0129","volume":"10","author":"M Mangaraj","year":"2017","unstructured":"Mangaraj M, Panda AK (2017) NBP-based icos\u03d5 control strategy for DSTATCOM\u201d. IET Power Electr 10(12):1617\u20131625","journal-title":"IET Power Electr"},{"issue":"9","key":"2289_CR20","doi-asserted-by":"publisher","first-page":"2304","DOI":"10.1049\/iet-pel.2018.5625","volume":"12","author":"M Mangaraj","year":"2019","unstructured":"Mangaraj M, Panda AK (2019) Modelling and simulation of KHLMS algorithm-based DSTATCOM. IET Power Electronics 12(9):2304\u20132311","journal-title":"IET Power Electronics"},{"key":"2289_CR21","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1049\/gtd2.12014","volume":"15","author":"M Mangaraj","year":"2021","unstructured":"Mangaraj M, Panda AK (2021) Sparse LMS algorithm for two-level DSTATCOM. IET Gener Transm Distrib 15:86\u201396. https:\/\/doi.org\/10.1049\/gtd2.12014","journal-title":"IET Gener Transm Distrib"},{"key":"2289_CR22","doi-asserted-by":"publisher","DOI":"10.1080\/03772063.2021.1920850","author":"M Mangaraj","year":"2021","unstructured":"Mangaraj M, Sabat J (2021) MVSI and AVSI-supported DSTATCOM for PQ analysis. IETE J Res. https:\/\/doi.org\/10.1080\/03772063.2021.1920850","journal-title":"IETE J Res"},{"issue":"4","key":"2289_CR23","doi-asserted-by":"publisher","first-page":"3575","DOI":"10.1109\/TPEL.2017.2707398","volume":"33","author":"M Merai","year":"2018","unstructured":"Merai M, Naouar MW, Slama-Belkhodja I (2018) An improved dc-link voltage control strategy for grid connected converters. IEEE Tran on Power Electr 33(4):3575\u20133582","journal-title":"IEEE Tran on Power Electr"},{"issue":"6","key":"2289_CR24","doi-asserted-by":"publisher","first-page":"4395","DOI":"10.1109\/TPEL.2016.2602219","volume":"32","author":"D Pan","year":"2017","unstructured":"Pan D, Ruan X, Wang X, Yu H, Xing Z (2017) Analysis and design of current control schemes for LCL-type grid-connected inverter based on a general mathematical model. IEEE Trans Power Electron 32(6):4395\u20134410","journal-title":"IEEE Trans Power Electron"},{"issue":"4","key":"2289_CR25","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1049\/iet-pel.2016.0556","volume":"10","author":"AK Panda","year":"2017","unstructured":"Panda AK, Mangaraj M (2017) DSTATCOM employing hybrid neural network control technique for power quality improvement. IET Power Electron 10(4):480\u2013489","journal-title":"IET Power Electron"},{"key":"2289_CR26","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1007\/s13198-021-01185-w","volume":"12","author":"A Qashou","year":"2021","unstructured":"Qashou A, Yousef S, Smadi AA et al (2021) Distribution system power quality compensation using a HSeAPF based on SRF and SMC features. Int J Syst Assur Eng Manag 12:976\u2013989. https:\/\/doi.org\/10.1007\/s13198-021-01185-w","journal-title":"Int J Syst Assur Eng Manag"},{"key":"2289_CR27","doi-asserted-by":"publisher","DOI":"10.1155\/2023\/3355124","author":"A Ramadevi","year":"2023","unstructured":"Ramadevi A, Srilakshmi K, Balachandran PK, Colak I, Dhanamjayulu C, Khan B (2023) Optimal design and performance investigation of artificial neural network controller for solar- and battery-connected unified power quality conditioner. Int J Energy Res. https:\/\/doi.org\/10.1155\/2023\/3355124","journal-title":"Int J Energy Res"},{"key":"2289_CR28","doi-asserted-by":"publisher","DOI":"10.1155\/2023\/4057091","author":"BN Reddy","year":"2023","unstructured":"Reddy BN, Goud BS, Kalyan ChNS, Balachandran PK, Aljafari B, Sangeetha K (2023) The Design of 2S2L-Based Buck-Boost Converter with a Wide Conversion Range. Int Trans Electr Energy Syst. https:\/\/doi.org\/10.1155\/2023\/4057091","journal-title":"Int Trans Electr Energy Syst"},{"issue":"2","key":"2289_CR29","doi-asserted-by":"publisher","first-page":"854","DOI":"10.1109\/TII.2014.2308437","volume":"10","author":"B Singh","year":"2014","unstructured":"Singh B, Jayaprakash P, Kothari DP, Chandra A, Haddad KA (2014) Comprehensive study of DSTATCOM configurations. IEEE Trans Industr Inf 10(2):854\u2013870","journal-title":"IEEE Trans Industr Inf"},{"key":"2289_CR30","doi-asserted-by":"publisher","first-page":"13992","DOI":"10.3390\/su142113992","volume":"14","author":"K Srilakshmi","year":"2022","unstructured":"Srilakshmi K, Sujatha CN, Balachandran PK, Mihet-Popa L, Kumar NU (2022a) Optimal design of an artificial intelligence controller for solar-battery integrated UPQC in three phase distribution networks. Sustainability 14:13992. https:\/\/doi.org\/10.3390\/su142113992","journal-title":"Sustainability"},{"key":"2289_CR31","doi-asserted-by":"publisher","first-page":"107116","DOI":"10.1109\/ACCESS.2022.3211504","volume":"10","author":"K Srilakshmi","year":"2022","unstructured":"Srilakshmi K et al (2022b) Design of soccer league optimization based hybrid controller for solar-battery integrated UPQC. IEEE Access 10:107116\u2013107136. https:\/\/doi.org\/10.1109\/ACCESS.2022.3211504","journal-title":"IEEE Access"},{"issue":"3","key":"2289_CR32","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1109\/TIE.2011.2167117","volume":"59","author":"Y Tang","year":"2012","unstructured":"Tang Y, Loh PC, Wang P, Choo FH, Gao F, Blaabjerg F (2012) Generalized design of high performance shunt active power filter with output LCL filter. IEEE Trans Ind Electron 59(3):1443\u20131452","journal-title":"IEEE Trans Ind Electron"},{"issue":"10","key":"2289_CR33","doi-asserted-by":"publisher","first-page":"6306","DOI":"10.1109\/TIE.2015.2420671","volume":"62","author":"CY Tang","year":"2015","unstructured":"Tang CY, Chen YF, Chen YM, Chang YR (2015) Dc-link voltage control strategy for three-phase back-to-back active power conditioners. IEEE Trans on Ind Elec 62(10):6306\u20136316","journal-title":"IEEE Trans on Ind Elec"},{"issue":"12","key":"2289_CR34","doi-asserted-by":"publisher","first-page":"7349","DOI":"10.1109\/TII.2020.2976906","volume":"16","author":"MD Vijay","year":"2020","unstructured":"Vijay MD, Singh B, Bhuvaneswari GA (2020) High-performance microgrid with a mechanical sensorlessSynRG operated wind energy generating system. IEEE Trans Ind Inform 16(12):7349\u20137359","journal-title":"IEEE Trans Ind Inform"},{"key":"2289_CR35","doi-asserted-by":"publisher","first-page":"14666","DOI":"10.3390\/su142214666","volume":"14","author":"M Vijayan","year":"2022","unstructured":"Vijayan M, Udumula RR, Mahto T, Lokeshgupta B, Goud BS, Kalyan CNS, Balachandran PK, Padmanaban S, Twala B (2022) Optimal PI-controller-based hybrid energy storage system in DC microgrid. Sustainability 14:14666. https:\/\/doi.org\/10.3390\/su142214666","journal-title":"Sustainability"},{"issue":"11","key":"2289_CR36","doi-asserted-by":"publisher","first-page":"6790","DOI":"10.1109\/TIE.2016.2581761","volume":"63","author":"D Zhou","year":"2016","unstructured":"Zhou D, Zhao J, Liu Y (2016) Independent control scheme for nonredundant two-leg fault-tolerant back-to-back converter-fed induction motor drives. IEEE Trans Ind Electr 63(11):6790\u20136800","journal-title":"IEEE Trans Ind Electr"}],"container-title":["International Journal of System Assurance Engineering and Management"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13198-024-02289-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s13198-024-02289-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s13198-024-02289-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,14]],"date-time":"2024-06-14T12:25:49Z","timestamp":1718367949000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s13198-024-02289-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,22]]},"references-count":36,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["2289"],"URL":"https:\/\/doi.org\/10.1007\/s13198-024-02289-9","relation":{},"ISSN":["0975-6809","0976-4348"],"issn-type":[{"value":"0975-6809","type":"print"},{"value":"0976-4348","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,22]]},"assertion":[{"value":"20 January 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 March 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no conflict regarding the publication of this work.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Not Applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human participants and\/or animals"}},{"value":"Not Applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}