{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T21:59:59Z","timestamp":1740175199515,"version":"3.37.3"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2021,8,22]],"date-time":"2021-08-22T00:00:00Z","timestamp":1629590400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,8,22]],"date-time":"2021-08-22T00:00:00Z","timestamp":1629590400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int. J. Fuzzy Syst."],"published-print":{"date-parts":[[2022,3]]},"DOI":"10.1007\/s40815-021-01154-2","type":"journal-article","created":{"date-parts":[[2021,8,22]],"date-time":"2021-08-22T13:02:21Z","timestamp":1629637341000},"page":"855-866","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Actuator Fault Compensation Based on a Takagi-Sugeno PI Observer: Application to a Thermoelectric Steam Generator"],"prefix":"10.1007","volume":"24","author":[{"given":"J.","family":"Reyes-Mart\u00ednez","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4678-9006","authenticated-orcid":false,"given":"C.-M.","family":"Astorga-Zaragoza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Madrigal-Espinosa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Chadli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.-A.","family":"Vargas-M\u00e9ndez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.-L.","family":"Osorio-Gordillo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Reyes-Reyes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,8,22]]},"reference":[{"issue":"6","key":"1154_CR1","doi-asserted-by":"publisher","first-page":"1756","DOI":"10.1007\/s40815-018-0481-8","volume":"20","author":"CM Astorga-Zaragoza","year":"2018","unstructured":"Astorga-Zaragoza, C.M., Osorio-Gordillo, G.L., Reyes-Martinez, J., Madrigal-Espinosa, G., Chadli, M.: Takagi\u2013sugeno observers as an alternative to nonlinear observers for analytical redundancy, application to a steam generator of a thermal power plant. Int. J. Fuzzy Syst. 20(6), 1756\u20131766 (2018)","journal-title":"Int. J. Fuzzy Syst."},{"issue":"1","key":"1154_CR2","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1080\/00207177208932249","volume":"16","author":"KJ \u00c5str\u00f6m","year":"2007","unstructured":"\u00c5str\u00f6m, K.J., Eklund, K.: A simplified non-linear model of a drum boiler-turbine unit. Int. J. Control 16(1), 145\u2013169 (2007)","journal-title":"Int. J. Control"},{"issue":"2","key":"1154_CR3","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1109\/TCST.2015.2458775","volume":"24","author":"W Birk","year":"2015","unstructured":"Birk, W., Dudarenko, N.: Reconfiguration of the air control system of a bark boiler. IEEE Trans. Control Syst. Technol. 24(2), 565\u2013577 (2015)","journal-title":"IEEE Trans. Control Syst. Technol."},{"key":"1154_CR4","doi-asserted-by":"crossref","unstructured":"Chandrasekharan, S., Panda, R.C., Swaminathan, B.N.: Statistical modeling of an integrated boiler for coal fired thermal power plant. Heliyon 3(6), e00,322 (2017)","DOI":"10.1016\/j.heliyon.2017.e00322"},{"key":"1154_CR5","unstructured":"Eborn, J.: Modelling and simulation of thermal power plants. Ph.D. thesis, Department of Automatic Control, Lund Institute of Technology (1998)"},{"key":"1154_CR6","doi-asserted-by":"crossref","unstructured":"Fadda, G., Pilloni, A., Pisano, A., Usai, E., Marjanovi\u0107, A., Vujnovi\u0107, S.: Sensor fault diagnosis in water-steam power plant: A combined observer-based\/pattern-recognition approach. In: 2015 International Workshop on Recent Advances in Sliding Modes (RASM), pp. 1\u20137. IEEE (2015)","DOI":"10.1109\/RASM.2015.7154643"},{"key":"1154_CR7","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.isatra.2018.11.045","volume":"88","author":"J Han","year":"2019","unstructured":"Han, J., Liu, X., Wei, X., Hu, X., Zhang, H.: Reduced-order observer based fault estimation and fault-tolerant control for switched stochastic systems with actuator and sensor faults. ISA Trans. 88, 91\u2013101 (2019)","journal-title":"ISA Trans."},{"key":"1154_CR8","doi-asserted-by":"crossref","unstructured":"Kazemi, A., Menhaj, M.B., Karrai, M., Daneshnia, A.: Control reconfiguration of a boiler-turbine unit after actuator faults. In: 2016 4th International Conference on Control, Instrumentation, and Automation (ICCIA), pp. 439\u2013444. IEEE (2016)","DOI":"10.1109\/ICCIAutom.2016.7483203"},{"key":"1154_CR9","volume-title":"Robust Integration of Model-Based Fault Estimation and Fault-Tolerant Control","author":"J Lan","year":"2020","unstructured":"Lan, J., Patton, R.J.: Robust Integration of Model-Based Fault Estimation and Fault-Tolerant Control. Springer, Berlin (2020)"},{"key":"1154_CR10","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-16776-8","volume-title":"Stability Analysis and Nonlinear Observer Design Using Takagi-Sugeno Fuzzy Models","author":"Z Lendek","year":"2011","unstructured":"Lendek, Z., Guerra, T.M., Babuska, R., De Schutter, B.: Stability Analysis and Nonlinear Observer Design Using Takagi-Sugeno Fuzzy Models. Springer, Berlin (2011). https:\/\/doi.org\/10.1007\/978-3-642-16776-8"},{"issue":"1","key":"1154_CR11","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1007\/s40815-019-00778-9","volume":"22","author":"S Li","year":"2020","unstructured":"Li, S., Kang, W., Ding, D.W.: Observer-based fuzzy fault-tolerant control for nonlinear parabolic pdes. Int. J. Fuzzy Syst. 22(1), 111\u2013121 (2020)","journal-title":"Int. J. Fuzzy Syst."},{"key":"1154_CR12","unstructured":"Liu, C., Wang, H., Ding, J., Zhen, C.: An overview of modelling and simulation of thermal power plant. In: International Conference on Advanced Mechatronic Systems, Zhengzhou, China, pp. 86\u201391 (2011)"},{"key":"1154_CR13","unstructured":"Lofberg, J.: Yalmip: A toolbox for modeling and optimization in MATLAB. In: 2004 IEEE International Conference on Robotics and Automation (IEEE Cat. No. 04CH37508), pp. 284\u2013289. IEEE (2004)"},{"issue":"5","key":"1154_CR14","doi-asserted-by":"publisher","first-page":"545","DOI":"10.6036\/8238","volume":"92","author":"G Madrigal-Espinosa","year":"2017","unstructured":"Madrigal-Espinosa, G., Astorga-Zaragoza, C., Adam-Medina, M., Osorio-Gordillo, G., V\u00e1zquez-Rom\u00e1n, M.: Diagn\u00f3stico de fallos en el control y compensaci\u00f3n de la medici\u00f3n por sensores virtuales en una central termoel\u00e9ctrica. DYNA 92(5), 545\u2013551 (2017)","journal-title":"DYNA"},{"key":"1154_CR15","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/j.epsr.2017.03.021","volume":"148","author":"G Madrigal-Espinosa","year":"2017","unstructured":"Madrigal-Espinosa, G., Osorio-Gordillo, G.L., Astorga-Zaragoza, C.M., V\u00e1zquez-Rom\u00e1n, M., Adam-Medina, M.: Fault detection and isolation system for boiler-turbine unit of a thermal power plant. Electric Power Syst. Res. 148, 237\u2013244 (2017)","journal-title":"Electric Power Syst. Res."},{"issue":"2","key":"1154_CR16","doi-asserted-by":"publisher","first-page":"10657","DOI":"10.3182\/20080706-5-KR-1001.01806","volume":"41","author":"Y Majanne","year":"2008","unstructured":"Majanne, Y.: Possibilities of fault tolerant control in thermal power plants. IFAC Proc. Vol. 41(2), 10657\u201310661 (2008)","journal-title":"IFAC Proc. Vol."},{"key":"1154_CR17","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.apm.2018.03.002","volume":"60","author":"M Moradi","year":"2018","unstructured":"Moradi, M., Chaibakhsh, A., Ramezani, A.: An intelligent hybrid technique for fault detection and condition monitoring of a thermal power plant. Appl. Math. Modell. 60, 34\u201347 (2018)","journal-title":"Appl. Math. Modell."},{"issue":"1\u20132","key":"1154_CR18","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1177\/0020294018754714","volume":"51","author":"M Pawlak","year":"2018","unstructured":"Pawlak, M.: Active fault tolerant control system for the measurement circuit in a drum boiler feed-water control system. Meas. Control 51(1\u20132), 4\u201315 (2018)","journal-title":"Meas. Control"},{"key":"1154_CR19","doi-asserted-by":"crossref","unstructured":"Stefanovski, J., Juri\u010di\u0107, \u0110.: Fault-tolerant control in presence of disturbances based on fault estimation. Syst. Control Lett. 138, 104,646 (2020)","DOI":"10.1016\/j.sysconle.2020.104646"},{"issue":"2","key":"1154_CR20","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.arcontrol.2008.03.008","volume":"32","author":"Y Zhang","year":"2008","unstructured":"Zhang, Y., Jiang, J.: Bibliographical review on reconfigurable fault-tolerant control systems. Annu. Rev. Control 32(2), 229\u2013252 (2008)","journal-title":"Annu. Rev. Control"}],"container-title":["International Journal of Fuzzy Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40815-021-01154-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s40815-021-01154-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s40815-021-01154-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,10]],"date-time":"2022-04-10T13:32:12Z","timestamp":1649597532000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s40815-021-01154-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,22]]},"references-count":20,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022,3]]}},"alternative-id":["1154"],"URL":"https:\/\/doi.org\/10.1007\/s40815-021-01154-2","relation":{},"ISSN":["1562-2479","2199-3211"],"issn-type":[{"type":"print","value":"1562-2479"},{"type":"electronic","value":"2199-3211"}],"subject":[],"published":{"date-parts":[[2021,8,22]]},"assertion":[{"value":"19 March 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 August 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}