{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,7]],"date-time":"2026-04-07T13:02:07Z","timestamp":1775566927060,"version":"3.50.1"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T00:00:00Z","timestamp":1657843200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T00:00:00Z","timestamp":1657843200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100011937","name":"Nieders\u00e4chsische Ministerium f\u00fcr Wissenschaft und Kultur","doi-asserted-by":"publisher","award":["11-76251-12-10\/19 ZN3491"],"award-info":[{"award-number":["11-76251-12-10\/19 ZN3491"]}],"id":[{"id":"10.13039\/100011937","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100019559","name":"Carl von Ossietzky Universit\u00e4t Oldenburg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100019559","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["SN COMPUT. SCI."],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Caregivers experience high musculoskeletal loads during their daily work, which leads to back complaints and a high rate of absenteeism at work. This reinforces the already existing discrepancy between the supply and demand of caregivers. Ergonomically correct working can significantly reduce musculoskeletal load. Therefore, we developed a system that recognizes potentially harmful body postures. In a study with 13 caregiver students, we analyzed the body postures, as well as muscle activities, and loads during the transfer of a patient from bed to wheelchair. The body postures were measured by a full-body motion capture system and a Multi-Kinect System. Muscle activities and loads were recorded via surface electromyography and a force plate. The posture analysis system is based on the motion capture data and considers the recommendations for ergonomic working in the care sector. The system generates a result report visualizing the skeleton model as well as color-coded information about inclination and torsion angles. The motion capture data were also related to EMG and force data and analyzed according to biomechanical assumptions.<\/jats:p>","DOI":"10.1007\/s42979-022-01263-1","type":"journal-article","created":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T13:04:36Z","timestamp":1657890276000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Posture and Mechanical Load Assessment During Patient Transfers"],"prefix":"10.1007","volume":"3","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1686-6752","authenticated-orcid":false,"given":"Sandra","family":"Hellmers","sequence":"first","affiliation":[]},{"given":"Anna","family":"Brinkmann","sequence":"additional","affiliation":[]},{"given":"Conrad Fifelski-von","family":"B\u00f6hlen","sequence":"additional","affiliation":[]},{"given":"Sandra","family":"Lau","sequence":"additional","affiliation":[]},{"given":"Rebecca","family":"Diekmann","sequence":"additional","affiliation":[]},{"given":"Andreas","family":"Hein","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2022,7,15]]},"reference":[{"key":"1263_CR1","unstructured":"Statistisches Bundesamt (Destatis): Koordinierte Bev\u00f6lkerungsberechnung, Wiesbaden, Germany; 2015."},{"key":"1263_CR2","doi-asserted-by":"publisher","first-page":"1717","DOI":"10.1136\/bmj.e1717","volume":"344","author":"LH Aiken","year":"2012","unstructured":"Aiken LH, Sermeus W, Van den Heede K, Sloane DM, Busse R, McKee M, Bruyneel L, Rafferty AM, Griffiths P, Moreno-Casbas MT, et al. Patient safety, satisfaction, and quality of hospital care: cross sectional surveys of nurses and patients in 12 countries in europe and the united states. BMJ. 2012;344:1717. https:\/\/doi.org\/10.1136\/bmj.e1717.","journal-title":"BMJ"},{"key":"1263_CR3","unstructured":"H\u00f6hmann U, Lautenschl\u00e4ger M, Schwarz L. Belastungen im pflegeberuf: Bedingungsfaktoren, folgen und desiderate. Pflege-Report, 2016:73\u201389."},{"issue":"4","key":"1263_CR4","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1093\/annhyg\/mes088","volume":"57","author":"M J\u00e4ger","year":"2013","unstructured":"J\u00e4ger M, Jordan C, Theilmeier A, Wortmann N, Kuhn S, Nienhaus A, Luttmann A. Lumbar-load analysis of manual patient-handling activities for biomechanical overload prevention among healthcare workers. Ann Occup Hygiene. 2013;57(4):528\u201344. https:\/\/doi.org\/10.1093\/annhyg\/mes088.","journal-title":"Ann Occup Hygiene"},{"issue":"3","key":"1263_CR5","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1007\/BF03374443","volume":"68","author":"M Wei\u00dfert-Horn","year":"2014","unstructured":"Wei\u00dfert-Horn M, Meyer MD, Jacobs M, Stern H, Raske H-W, Landau K. Ergonomisch richtige arbeitsweise beim transfer von schwerstpflegebed\u00fcrftigen. Zeitschrift f\u00fcr Arbeitswissenschaft. 2014;68(3):175\u201384.","journal-title":"Zeitschrift f\u00fcr Arbeitswissenschaft"},{"key":"1263_CR6","unstructured":"Kliner K, Rennert D, Richter M. Gesundheit und arbeit-blickpunkt gesundheitswesen: Bkk gesundheitsatlas, 2017; 2017."},{"issue":"7","key":"1263_CR7","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1177\/0018720819827208","volume":"61","author":"J Hwang","year":"2019","unstructured":"Hwang J, Kuppam VA, Chodraju SSR, Chen J, Kim JH. Commercially available friction-reducing patient-transfer devices reduce biomechanical stresses on caregivers\u2019 upper extremities and low back. Human Factors. 2019;61(7):1125\u201340. https:\/\/doi.org\/10.1177\/0018720819827208.","journal-title":"Human Factors"},{"issue":"2","key":"1263_CR8","doi-asserted-by":"publisher","first-page":"439","DOI":"10.3233\/WOR-152222","volume":"53","author":"SD Choi","year":"2016","unstructured":"Choi SD, Brings K. Work-related musculoskeletal risks associated with nurses and nursing assistants handling overweight and obese patients: A literature review. Work. 2016;53(2):439\u201348. https:\/\/doi.org\/10.3233\/WOR-152222.","journal-title":"Work"},{"key":"1263_CR9","unstructured":"Michaelis M, Hermann S. Evaluation des pflegekonzepts r\u00fcckengerechter patiententransfer in der kranken-und altenpflege. Langzeit-Follow-up zur Ermittlung der Nachhaltigkeit pr\u00e4ventiver Effekte. Schriftenreihe der Bundesanstalt f\u00fcr Arbeitsschutz und Arbeitsmedizin (F2196). Dortmund; 2010."},{"key":"1263_CR10","doi-asserted-by":"publisher","unstructured":"Hellmers S, Brinkmann A, B\u00f6hlen C, Lau S, Diekmann R, Hein A. Assessing Postures and Mechanical Loads During Patient Transfers. In: Proceedings of the 14th International Joint Conference on Biomedical Engineering Systems and Technologies, pp. 2021:21\u201329. SciTePress, HEALTHINF . https:\/\/doi.org\/10.5220\/0010155300210029. INSTICC.","DOI":"10.5220\/0010155300210029"},{"key":"1263_CR11","doi-asserted-by":"crossref","unstructured":"Sharan D, Rajkumar JS. The burden of caregiving: musculoskeletal disorders in caregivers of children with cerebral palsy. In: Congress of the International Ergonomics Association; 2018:717\u2013718. Springer.","DOI":"10.1007\/978-3-319-96098-2_87"},{"key":"1263_CR12","first-page":"130","volume":"31","author":"S Freitag","year":"2007","unstructured":"Freitag S, Fincke I, Dulon M, Ellegast R, Nienhaus A. Messtechnische analyse von belastenden k\u00f6rperhaltungen bei pflegekr\u00e4ften: eine geriatrische station im vergleich mit anderen krankenhausstationen. ErgoMed. 2007;31:130\u201340.","journal-title":"ErgoMed"},{"issue":"1","key":"1263_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40648-019-0139-9","volume":"6","author":"N Kudo","year":"2019","unstructured":"Kudo N, Yamada Y, Ito D. Age-related injury risk curves for the lumbar spine for use in low-back-pain prevention in manual handling tasks. Robomech J. 2019;6(1):1\u201310.","journal-title":"Robomech J."},{"key":"1263_CR14","unstructured":"Kushariyadi Hakam M, Nabilah N. Impact of work posture on musculoskeletal disorder in nurses. In: The 3rd Joint International Conference, 2021;3:278\u2013282."},{"issue":"10","key":"1263_CR15","doi-asserted-by":"publisher","first-page":"131","DOI":"10.3991\/ijoe.v17i10.25161","volume":"17","author":"K Kitagawa","year":"2021","unstructured":"Kitagawa K, Yamamoto K, Wada C. Relationship between foot position and lumbar loads while turning patients on a bed: an investigation via computational simulation and electromyography. Int J Online Biomed Eng. 2021;17(10):131\u201343.","journal-title":"Int J Online Biomed Eng."},{"issue":"6","key":"1263_CR16","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1080\/1463922X.2012.678283","volume":"14","author":"K Schaub","year":"2013","unstructured":"Schaub K, Caragnano G, Britzke B, Bruder R. The European assembly worksheet. Theoret Issues Ergon Sci. 2013;14(6):616\u201339. https:\/\/doi.org\/10.1080\/1463922X.2012.678283.","journal-title":"Theoret Issues Ergon Sci."},{"issue":"8","key":"1263_CR17","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1093\/annhyg\/meq063","volume":"54","author":"A Theilmeier","year":"2010","unstructured":"Theilmeier A, Jordan C, Luttmann A, J\u00e4ger M. Measurement of action forces and posture to determine the lumbar load of healthcare workers during care activities with patient transfers. Annals Occup Hygiene. 2010;54(8):923\u201333. https:\/\/doi.org\/10.1093\/annhyg\/meq063.","journal-title":"Annals Occup Hygiene"},{"key":"1263_CR18","unstructured":"Wei L, Tsai C-Y, Koontz AM. The relationship between joint ranges of motion and joint kinetics during sitting pivot wheelchair transfers. Proceedings of the Conference of the Rehabilitation Engineering and Assistive Technology Society of North America; 2018."},{"key":"1263_CR19","unstructured":"Agrawal A, Ertel W. Automatic nursing care trainer based on machine learning. In: KHD@ IJCAI, pp. 2018:53\u201359."},{"issue":"9","key":"1263_CR20","doi-asserted-by":"publisher","first-page":"2975","DOI":"10.3390\/s18092975","volume":"18","author":"C Lin","year":"2018","unstructured":"Lin C, Kanai-Pak M, Maeda J, Kitajima Y, Nakamura M, Kuwahara N, Ogata T, Ota J. Translational acceleration, rotational speed, and joint angle of patients related to correct\/incorrect methods of transfer skills by nurses. Sensors. 2018;18(9):2975. https:\/\/doi.org\/10.3390\/s18092975.","journal-title":"Sensors"},{"key":"1263_CR21","doi-asserted-by":"publisher","unstructured":"Ding J, Lim Y-J, Solano M, Shadle K, Park C, Lin C, Hu J. Giving patients a lift-the robotic nursing assistant (rona). In: 2014 IEEE International Conference on Technologies for Practical Robot Applications (TePRA), pp. 2014:1\u20135 . https:\/\/doi.org\/10.1109\/TePRA.2014.6869137. IEEE.","DOI":"10.1109\/TePRA.2014.6869137"},{"key":"1263_CR22","unstructured":"Safety of machinery - Human physical performance - Part 4: Evaluation of working postures and movements in relation to machinery; German version. DIN EN 1005-4:2005; 2005."},{"key":"1263_CR23","volume-title":"Pr\u00e4vention von r\u00fcckenbeschwerden; topas\\_r-konzept der bgw f\u00fcr pflege und betreuung","author":"F Baum","year":"2012","unstructured":"Baum F, Beck B, Fischer B, Gl\u00fcsing R, Graupner I, et al. Pr\u00e4vention von r\u00fcckenbeschwerden; topas_r-konzept der bgw f\u00fcr pflege und betreuung. Hamburg, Germany: Berufsgenossenschaft f\u00fcr Gesundheitsdienst und Wohlfahrtspflege; 2012."},{"issue":"4","key":"1263_CR24","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1007\/s10039-015-0093-6","volume":"17","author":"B Kusma","year":"2015","unstructured":"Kusma B, Glaesener J-J, Brandenburg S, Pietsch A, Fischer K, Schmidt J, Behl-Sch\u00f6n S, Pohrt U. Der pflege das kreuz st\u00e4rken - individualpr\u00e4vention r\u00fccken bei der berufsgenossenschaft f\u00fcr gesundheitsdienst und wohlfahrtspflege. Trauma und Berufskrankheit. 2015;17(4):244\u20139. https:\/\/doi.org\/10.1007\/s10039-015-0093-6.","journal-title":"Trauma und Berufskrankheit"},{"key":"1263_CR25","doi-asserted-by":"publisher","unstructured":"Fifelski C, Brinkmann A, Ortmann SM, Isken M, Hein A. Multi depth camera system for 3d data recording for training and education of nurses. In: 2018 International Conference on Computational Science and Computational Intelligence (CSCI), pp. 2018:679\u2013684 . https:\/\/doi.org\/10.1109\/CSCI46756.2018.00137. IEEE","DOI":"10.1109\/CSCI46756.2018.00137"},{"key":"1263_CR26","unstructured":"Shadow Motion Workshop, Motion Capture System, www.motionshadow.com, accessed: 28.04.2020 2020. http:\/\/www.motionshadow.com"},{"key":"1263_CR27","unstructured":"3D4Medical: Essential Anatomy 5 (5.0.8). 3D4Medical, Dublin, Ireland. accessed 10.05.2019 2020. https:\/\/3d4medical.com\/apps\/essential-anatomy-5"},{"issue":"2","key":"1263_CR28","first-page":"13","volume":"8","author":"HJ Hermens","year":"1999","unstructured":"Hermens HJ, Freriks B, Merletti R, Stegeman D, Blok J, Rau G, Disselhorst-Klug C, H\u00e4gg G. European recommendations for surface electromyography. Roessingh Res Dev. 1999;8(2):13\u201354.","journal-title":"Roessingh Res Dev."},{"issue":"4","key":"1263_CR29","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1016\/S0021-9290(01)00222-6","volume":"35","author":"G Wu","year":"2002","unstructured":"Wu G, Siegler S, Allard P, Kirtley C, Leardini A, Rosenbaum D, Whittle M, D\u2019Lima D, Cristofolini L, Witte H, et al. Isb recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion-part i: ankle, hip, and spine. J Biomech. 2002;35(4):543\u20138.","journal-title":"J Biomech."},{"key":"1263_CR30","unstructured":"Van Minnen JH. Kapitel 3: Biomechanik der wirbels\u00e4ule. In: Westerhuis, R. Pieter und\u00a0Wiesner (ed.) Klinische Muster in der Manuellen Therapie, pp. 106\u2013107. Georg Thieme Verlag, Stuttgart, 2nd edn; 2014."},{"key":"1263_CR31","unstructured":"Panjabi MM, White A. Clinical biomechanics of the spine; 1990."},{"key":"1263_CR32","doi-asserted-by":"publisher","DOI":"10.1016\/B978-044310178-6.50010-4","author":"A Vleeming","year":"2007","unstructured":"Vleeming A, Stoeckart R. The role of the pelvic girdle in coupling the spine and the legs: a clinical-anatomical perspective on pelvic stability. Movement Stability Lumbopelvic Pain. 2007. https:\/\/doi.org\/10.1016\/B978-044310178-6.50010-4.","journal-title":"Movement Stability Lumbopelvic Pain"},{"issue":"4","key":"1263_CR33","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1097\/00007632-200202150-00015","volume":"27","author":"CA Richardson","year":"2002","unstructured":"Richardson CA, Snijders CJ, Hides JA, Damen L, Pas MS, Storm J. The relation between the transversus abdominis muscles, sacroiliac joint mechanics, and low back pain. Spine. 2002;27(4):399\u2013405. https:\/\/doi.org\/10.1097\/00007632-200202150-00015.","journal-title":"Spine"},{"issue":"3","key":"1263_CR34","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1007\/s00586-003-0575-2","volume":"13","author":"J-P van Wingerden","year":"2004","unstructured":"van Wingerden J-P, Vleeming A, Buyruk H, Raissadat K. Stabilization of the sacroiliac joint in vivo: verification of muscular contribution to force closure of the pelvis. Eur Spine J. 2004;13(3):199\u2013205. https:\/\/doi.org\/10.1007\/s00586-003-0575-2.","journal-title":"Eur Spine J."},{"key":"1263_CR35","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0136375","author":"N Hammer","year":"2015","unstructured":"Hammer N, M\u00f6bius R, Schleifenbaum S, Hammer K-H, Klima S, Lange JS, Soisson O, Winkler D, Milani TL. Pelvic belt effects on health outcomes and functional parameters of patients with sacroiliac joint pain. PloS One. 2015. https:\/\/doi.org\/10.1371\/journal.pone.0136375.","journal-title":"PloS One"},{"key":"1263_CR36","unstructured":"Garrett WE, Kirkendall DT. Exercise and sport science; 2000."},{"key":"1263_CR37","unstructured":"Mansfield PJ, Neumann DA. Essentials of kinesiology for the physical therapist assistant; 2008."},{"issue":"1","key":"1263_CR38","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1680\/jnaen.19.00021","volume":"9","author":"A Brinkmann","year":"2020","unstructured":"Brinkmann A, Fifelski C, Lau S, Kowalski C, Meyer O, Diekmann R, Isken M, Fudickar S, Hein A. The aal\/care laboratory - a healthcare prevention system for caregivers. Nanomater Energy. 2020;9(1):1\u201310. https:\/\/doi.org\/10.1680\/jnaen.19.00021.","journal-title":"Nanomater Energy"},{"issue":"1","key":"1263_CR39","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.jelekin.2014.08.013","volume":"25","author":"HS Longpr\u00e9","year":"2015","unstructured":"Longpr\u00e9 HS, Acker SM, Maly MR. Muscle activation and knee biomechanics during squatting and lunging after lower extremity fatigue in healthy young women. J Electromyograp Kinesiol. 2015;25(1):40\u20136. https:\/\/doi.org\/10.1016\/j.jelekin.2014.08.013.","journal-title":"J Electromyograp Kinesiol."},{"issue":"1","key":"1263_CR40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1152\/ajplegacy.1907.20.1.1","volume":"20","author":"WP Lombard","year":"1907","unstructured":"Lombard WP, Abbott F. The mechanical effects produced by the contraction of individual muscles of the thigh of the frog. American J Physiol-Legacy Content. 1907;20(1):1\u201360. https:\/\/doi.org\/10.1152\/ajplegacy.1907.20.1.1.","journal-title":"American J Physiol-Legacy Content"},{"issue":"1","key":"1263_CR41","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/j.jelekin.2006.07.010","volume":"18","author":"VC Dionisio","year":"2008","unstructured":"Dionisio VC, Almeida GL, Duarte M, Hirata RP. Kinematic, kinetic and emg patterns during downward squatting. J Electromyogr Kinesiol. 2008;18(1):134\u201343. https:\/\/doi.org\/10.1016\/j.jelekin.2006.07.010.","journal-title":"J Electromyogr Kinesiol."},{"issue":"3","key":"1263_CR42","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1519\/JSC.0000000000001323","volume":"31","author":"LV Slater","year":"2017","unstructured":"Slater LV, Hart JM. Muscle activation patterns during different squat techniques. J Strength Conditioning Res. 2017;31(3):667\u201376. https:\/\/doi.org\/10.1519\/JSC.0000000000001323.","journal-title":"J Strength Conditioning Res"},{"key":"1263_CR43","doi-asserted-by":"publisher","unstructured":"Brinkmann A, B\u00f6hlen C, Hellmers S, Meyer O, Diekmann R, Hein A. Physical burden in manual patient handling: Quantification of lower limb emg muscle activation patterns of healthy individuals lifting different loads ergonomically. In: Proceedings of the 14th International Joint Conference on Biomedical Engineering Systems and Technologies, pp. 2021:451\u2013458. SciTePress, HEALTHINF . https:\/\/doi.org\/10.5220\/0010247804510458. INSTICC.","DOI":"10.5220\/0010247804510458"},{"issue":"1","key":"1263_CR44","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s10237-011-0290-6","volume":"11","author":"M Christophy","year":"2012","unstructured":"Christophy M, Faruk Senan NA, Lotz JC, O\u2019Reilly OM. A musculoskeletal model for the lumbar spine. Biomech Model Mechanobiol. 2012;11(1):19\u201334.","journal-title":"Biomech Model Mechanobiol"},{"key":"1263_CR45","doi-asserted-by":"publisher","unstructured":"Bassani T, Galbusera F. Chapter 15 - musculoskeletal modeling. In: Galbusera, F., Wilke, H.-J. (eds.) Biomechanics of the Spine, pp. 257\u2013277. Academic Press, United States 2018. https:\/\/doi.org\/10.1016\/B978-0-12-812851-0.00015-X","DOI":"10.1016\/B978-0-12-812851-0.00015-X"},{"key":"1263_CR46","first-page":"00331","volume":"21","author":"N Kudo","year":"2022","unstructured":"Kudo N, Yamada Y, Xiang X, Nakamura H, Akiyama Y. Concept of mathematical modeling of lumbar and thoracic spine based on elastic beam theory. J Biomech Sci Eng. 2022;21:00331.","journal-title":"J Biomech Sci Eng."}],"container-title":["SN Computer Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s42979-022-01263-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s42979-022-01263-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s42979-022-01263-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,19]],"date-time":"2022-09-19T19:23:18Z","timestamp":1663615398000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s42979-022-01263-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,15]]},"references-count":46,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2022,9]]}},"alternative-id":["1263"],"URL":"https:\/\/doi.org\/10.1007\/s42979-022-01263-1","relation":{},"ISSN":["2661-8907"],"issn-type":[{"value":"2661-8907","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,15]]},"assertion":[{"value":"12 October 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the ethics committee (ethical vote: Carl von Ossietzky University Oldenburg No. Drs. EK\/2019\/004) and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}}],"article-number":"375"}}