{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T16:23:53Z","timestamp":1759335833695,"version":"3.37.3"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,1,13]],"date-time":"2024-01-13T00:00:00Z","timestamp":1705104000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,1,13]],"date-time":"2024-01-13T00:00:00Z","timestamp":1705104000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100007601","name":"Horizon 2020","doi-asserted-by":"publisher","award":["825429"],"award-info":[{"award-number":["825429"]}],"id":[{"id":"10.13039\/501100007601","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004270","name":"Royal Institute of Technology","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004270","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["SN COMPUT. SCI."],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A Stewart platform is a six-degree-of-freedom parallel manipulator widely used as the motion base for flight simulators and antenna positioning systems, among others. This work presents a novel mechatronics-twin framework that integrates such a manipulator with advanced biomechanical models and simulations for effective exploration of operational behaviors of prosthetic sockets with amputees. By means of the biomechanical models and simulations, the framework allows the users to first analyze the fundamental operational characteristics of individual amputees according to their specific body geometries, pelvis-femur structures, and sizes of transfemoral sockets. Such operational characteristics are then fed to one Stewart platform as the reference control signals for the generation of dynamic loads and behaviors of prosthetic sockets that are otherwise difficult to observe or realize with the real amputees. Experiments in form of integration testing show that the proposed control strategy is capable of generating expected dynamic operational conditions. Currently, the mechatronics-twin framework supports a wide range of biomechanical configurations and the quantification of the respective intra-socket load conditions for socket design optimization and anomaly detection.<\/jats:p>","DOI":"10.1007\/s42979-023-02485-7","type":"journal-article","created":{"date-parts":[[2024,1,13]],"date-time":"2024-01-13T11:02:16Z","timestamp":1705143736000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Developing a Mechatronics-Twin Framework for Effective Exploration of Operational Behaviors of Prosthetic Sockets"],"prefix":"10.1007","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7048-0108","authenticated-orcid":false,"given":"Dejiu","family":"Chen","sequence":"first","affiliation":[]},{"given":"Suranjan","family":"Ottikkutti","sequence":"additional","affiliation":[]},{"given":"Kaveh Nazem","family":"Tahmasebi","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2024,1,13]]},"reference":[{"key":"2485_CR1","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1097\/MD.0000000000012296","volume":"97","author":"EC Baars","year":"2018","unstructured":"Baars EC, Schrier E, Dijkstra PU, Geertzen JH. Prosthesis satisfaction in lower limb amputees: a systematic review of associated factors and questionnaires. Medicine. 2018;97:39.","journal-title":"Medicine"},{"key":"2485_CR2","volume-title":"Handbook of sensors and actuators","author":"M Bao","year":"2000","unstructured":"Bao M. Micro mechanical transducers: pressure sensors, mechanical transducers: pressure sensors, accelerometers and gyroscopes. In: Handbook of sensors and actuators. Amsterdam: Elsevier; 2000."},{"key":"2485_CR3","first-page":"59","volume-title":"Mechatronic futures","author":"S Boschert","year":"2016","unstructured":"Boschert S, Rosen R. Digital twin - the simulation aspect. In: Mechatronic futures. Berlin: Springer; 2016. p. 59\u201374."},{"key":"2485_CR4","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1109\/4233.809169","volume":"3","author":"G Brandt","year":"1999","unstructured":"Brandt G, Zimolong A, Carrat L, Merloz P, Staudte HW, Lavall\u00e9e S, Radermacher K, Rau G. Crigos: a compact robot for image-guided orthopedic surgery. IEEE Trans Inf Technol Biomed. 1999;3:252\u201360.","journal-title":"IEEE Trans Inf Technol Biomed"},{"key":"2485_CR5","doi-asserted-by":"publisher","first-page":"3","DOI":"10.3109\/03093649709164552","volume":"21","author":"W Buis","year":"1997","unstructured":"Buis W, Convery P. Calibration problems encountered while monitoring stump\/socket interface pressures with force sensing resistors: techniques adopted to minimise inaccuracies. Prosthet Orthot Int. 1997;21:3.","journal-title":"Prosthet Orthot Int"},{"issue":"11","key":"2485_CR6","doi-asserted-by":"publisher","first-page":"3764","DOI":"10.3390\/s21113764","volume":"21","author":"V Dejke","year":"2021","unstructured":"Dejke V, Eng MP, Brinkfeldt K, Charnley J, Lussey D, Lussey C. Development of prototype low-cost qtss$$^{{\\rm TM}}$$ wearable flexible more enviro-friendly pressure, shear, and friction sensors for dynamic prosthetic fit monitoring. Sensors. 2021;21(11):3764.","journal-title":"Sensors"},{"issue":"11","key":"2485_CR7","doi-asserted-by":"publisher","first-page":"1940","DOI":"10.1109\/TBME.2007.901024","volume":"54","author":"SL Delp","year":"2007","unstructured":"Delp SL, Anderson FC, Arnold AS, Loan P, Habib A, John CT, Guendelman E, Thelen DG. Opensim: open-source software to create and analyze dynamic simulations of movement. IEEE Trans Biomed Eng. 2007;54(11):1940\u201350.","journal-title":"IEEE Trans Biomed Eng"},{"key":"2485_CR8","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1243\/09544062JMES1137","volume":"223","author":"E Fichter","year":"2008","unstructured":"Fichter E, Kerr D, Rees-Jones J. The Gough\u2013Stewart platform parallel manipulator: a retrospective appreciation. J Mech Eng Sci. 2008;223:243\u201381.","journal-title":"J Mech Eng Sci"},{"key":"2485_CR9","first-page":"4459","volume":"31","author":"M Furqan","year":"2017","unstructured":"Furqan M, Suhaib M, Ahmad N. Studies on Stewart platform manipulator: a review. J Mech Eng Sci. 2017;31:4459\u201370.","journal-title":"J Mech Eng Sci"},{"key":"2485_CR10","doi-asserted-by":"crossref","unstructured":"Geng Y, Yang P, Xu X, Chen L. Design and simulation of active transfemoral prosthesis. In: 2012 24th Chinese Control and Decision Conference (CCDC). 2012. p.\u00a03724\u20138.","DOI":"10.1109\/CCDC.2012.6243095"},{"key":"2485_CR11","unstructured":"Grace K, Colgate J, Glucksberg M, Chun J. Studies on Stewart platform manipulator: a review. In: Proceedings IEEE International Conference on Robotics and Automation, 1993."},{"key":"2485_CR12","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1017\/S0263574703005046","volume":"21","author":"K Harib","year":"2003","unstructured":"Harib K, SrinivasanHood K. Kinematic and dynamic analysis of Stewart platform-based machine tool structures. Robotica. 2003;21:541\u201354.","journal-title":"Robotica"},{"key":"2485_CR13","doi-asserted-by":"crossref","unstructured":"Jamaludin MS, Hanafusa A, Yamamoto S-I, Agarie Y, Otsuka H, Onishi K. Evaluation of the effects of geometrical changes in prosthetic socket towards transfemoral residuum via finite element method. In: 2018 IEEE-EMBS Conference on Biomedical Engineering and Sciences (IECBES). IEEE; 2018. p.\u00a0314\u20139.","DOI":"10.1109\/IECBES.2018.8626703"},{"key":"2485_CR14","doi-asserted-by":"publisher","first-page":"10","DOI":"10.3390\/s17102399","volume":"17","author":"I Khodasevych","year":"2017","unstructured":"Khodasevych I, Parmar S, Troynikov O. Flexible sensors for pressure therapy: effect of substrate curvature and stiffness on sensor performance. Sensors. 2017;17:10.","journal-title":"Sensors"},{"key":"2485_CR15","unstructured":"Mohamed A. Modeling and simulation of transfemoral amputee gait. Engineering, Medicine; 2018."},{"key":"2485_CR16","doi-asserted-by":"crossref","unstructured":"Rossell J, Palacios-Quinonero F, Rubio-Massegu J, Vicente-Rodrigo J. Tracking control for a stewart platform prototype. In: 2015 international conference on advanced mechatronics, intelligent manufacture, and industrial automation (ICAMIMIA); 2015.","DOI":"10.1109\/ICAMIMIA.2015.7508003"},{"key":"2485_CR17","doi-asserted-by":"crossref","unstructured":"Schmidt R, Singh K. Meshmixer: an interface for rapid mesh composition. ACM SIGGRAPH 2010 Talks. Article No. 6; 2010. p. 1","DOI":"10.1145\/1837026.1837034"},{"issue":"1","key":"2485_CR18","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1007\/s12206-016-1238-7","volume":"31","author":"A \u015eumnu","year":"2017","unstructured":"\u015eumnu A, G\u00fczelbey \u0130H, \u00c7akir MV. Simulation and PID control of a Stewart platform with linear motor. J Mech Sci Technol. 2017;31(1):345\u201356.","journal-title":"J Mech Sci Technol"},{"key":"2485_CR19","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1191\/0142331203tm092oa","volume":"25","author":"M Wapler","year":"2003","unstructured":"Wapler M, Urban V, Weisener T, Stallkamp J, D\u00fcrr M, Hiller A. Studies on Stewart platform manipulator: a review. Trans Inst Meas Control. 2003;25:279\u201380.","journal-title":"Trans Inst Meas Control"},{"key":"2485_CR20","unstructured":"Willson AM. A quasi-passive biarticular prosthesis and novel musculoskeletal model for transtibial amputees. Master Thesis, University of Washington; 2017."},{"key":"2485_CR21","volume-title":"Kinematics and dynamics of machinery","author":"C Wilson","year":"1993","unstructured":"Wilson C, Sadler J. Kinematics and dynamics of machinery. 3rd ed. New York: Harper Collins College Publishers; 1993.","edition":"3"},{"key":"2485_CR22","volume-title":"Lumped parameter and modal models to simulate ground reaction forces due to running","author":"LR Zanetti","year":"2021","unstructured":"Zanetti LR. Lumped parameter and modal models to simulate ground reaction forces due to running. Universidade Estadual Paulista (Unesp); 2021."}],"container-title":["SN Computer Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s42979-023-02485-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s42979-023-02485-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s42979-023-02485-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T00:33:55Z","timestamp":1731026035000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s42979-023-02485-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,13]]},"references-count":22,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,2]]}},"alternative-id":["2485"],"URL":"https:\/\/doi.org\/10.1007\/s42979-023-02485-7","relation":{},"ISSN":["2661-8907"],"issn-type":[{"type":"electronic","value":"2661-8907"}],"subject":[],"published":{"date-parts":[[2024,1,13]]},"assertion":[{"value":"20 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 January 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"205"}}