{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T15:16:00Z","timestamp":1791645360100,"version":"4.3.4"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[1994,6,1]],"date-time":"1994-06-01T00:00:00Z","timestamp":770428800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diabetologia"],"published-print":{"date-parts":[[1994,6]]},"DOI":"10.1007\/bf00403381","type":"journal-article","created":{"date-parts":[[2004,10,23]],"date-time":"2004-10-23T23:16:01Z","timestamp":1098573361000},"page":"610-616","source":"Crossref","is-referenced-by-count":42,"title":["Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: demonstration in rats and man"],"prefix":"10.1007","volume":"37","author":[{"given":"D.","family":"Moatti-Sirat","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"Poitout","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"Thom\ufffd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. N.","family":"Gangnerau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Y.","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Y.","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. S.","family":"Wilson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Lemonnier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. C.","family":"Klein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Reach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"CR1","volume-title":"Biosensors: a practical approach","author":"GS Wilson","year":"1980","unstructured":"Wilson GS, Th\u00e9venot DR (1980) Unmediated amperometric enzyme electrodes. In: Cass AEG (ed) Biosensors: a practical approach. IRL Press, Oxford University Press, Oxford"},{"key":"CR2","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/0009-8981(89)90301-X","volume":"93","author":"Y Yamasaki","year":"1989","unstructured":"Yamasaki Y, Ueda N, Nao K et al. (1989) Direct measurements of whole blood glucose by a needle-type glucose sensor. Clin Chim Acta 93: 93?98","journal-title":"Clin Chim Acta"},{"issue":"11 &12","key":"CR3","doi-asserted-by":"crossref","first-page":"2403","DOI":"10.1080\/00032718908052362","volume":"22","author":"K Amine","year":"1989","unstructured":"Amine K, Kauffman JM, Patriarche GJ, Guilbault GG (1989) Electrochemical behaviour of a lipid modified enzyme electrode. Anal Lett 22 (11 &12): 2403?2411","journal-title":"Anal Lett"},{"key":"CR4","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/0956-5663(92)85030-E","volume":"7","author":"D Moatti-Sirat","year":"1991","unstructured":"Moatti-Sirat D, Velho G, Reach G (1991) Evaluating in vitro and in vito the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor. Biosens Bioelectron 7: 345?352","journal-title":"Biosens Bioelectron"},{"key":"CR5","first-page":"885","volume":"50","author":"S Saeger","year":"1991","unstructured":"Saeger S, Preidel W, Lucadou IV, Luprecht L, Lager W (1991) Influence of urea on the glucose measurement by electrocatalytic sensor in the extracorporeal blood circulation of a sheep. Biomed Biochim Acta 50;7: 885?891","journal-title":"Biomed Biochim Acta"},{"key":"CR6","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1055\/s-2007-1003375","volume":"24","author":"S Saeger","year":"1992","unstructured":"Saeger S, Preidel W, Luprecht L (1992) Influence of paracetamol, sulfanilamide and ascorbic acid on the electrocatalytic glucose sensor. Horm Metab Res 24: 504?507","journal-title":"Horm Metab Res"},{"key":"CR7","doi-asserted-by":"crossref","first-page":"1692","DOI":"10.1021\/ac00017a008","volume":"63","author":"DS Bindra","year":"1991","unstructured":"Bindra DS, Zhang Y, Wilson GS et al. (1991) Design and in vitro studies of a needle type glucose sensor for subcutaneous monitoring. Anal Chem 63: 1692?1696","journal-title":"Anal Chem"},{"key":"CR8","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/0265-928X(89)80032-X","volume":"4","author":"R Sternberg","year":"1988","unstructured":"Sternberg R, Barrau MB, Gangiotti L et al. (1988) Study and development of needle-type multilayer enzyme-based glucose microsensor. Biosensors 4: 27?40","journal-title":"Biosensors"},{"key":"CR9","doi-asserted-by":"crossref","first-page":"93","DOI":"10.2165\/00003088-198207020-00001","volume":"7","author":"JAH Forrest","year":"1982","unstructured":"Forrest JAH, Clements JA, Prescott LF (1982) Pharmacokinetics of paracetamol. Clin Pharmacokin 7: 93?107","journal-title":"Clin Pharmacokin"},{"key":"CR10","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1111\/j.2042-7158.1963.tb12812.x","volume":"15","author":"JR Gwlit","year":"1963","unstructured":"Gwlit JR, Robertson A, Goldman L, Blanchard AW (1963) The absorption characteristics of paracetamol tablets in man. J Pharm Pharmacol 15: 445?453","journal-title":"J Pharm Pharmacol"},{"key":"CR11","first-page":"957","volume":"48","author":"G Velho","year":"1989","unstructured":"Velho G, Froguel Ph, Th\u00e9venot DR, Reach G (1989) Strategies for calibrating a subcutaneous glucose sensor. Biochem Biomed Acta 48: 957?964","journal-title":"Biochem Biomed Acta"},{"key":"CR12","doi-asserted-by":"crossref","first-page":"9004","DOI":"10.1021\/ja00023a091","volume":"113","author":"R Maidan","year":"1991","unstructured":"Maidan R, Heller A (1991) Elimination of electrooxidizable interferants in glucose electrodes. J Am Chem Soc 113: 9004?9006","journal-title":"J Am Chem Soc"},{"key":"CR13","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1007\/BF00400921","volume":"35","author":"D Moatti-Sirat","year":"1992","unstructured":"Moatti-Sirat D, Capron F, Poitout V et al. (1992) Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Diabetologia 35: 224?230","journal-title":"Diabetologia"},{"key":"CR14","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/0141-5425(92)90033-H","volume":"14","author":"K Rebrin","year":"1992","unstructured":"Rebrin K, Fischer U, Hahn von Dorsche H, von Woetke T, Abel P, Brunstein E (1992) Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality? J Biomed Eng 14: 33?40","journal-title":"J Biomed Eng"},{"key":"CR15","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1016\/0956-5663(92)85010-8","volume":"7","author":"V Poitout","year":"1992","unstructured":"Poitout V, Moatti-Sirat D, Reach G (1992) Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination. Biosens Bioelectron 7: 587?592","journal-title":"Biosens Bioelectron"},{"key":"CR16","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1007\/BF00404077","volume":"36","author":"V Poitout","year":"1993","unstructured":"Poitout V, Moatti-Sirat D, Reach G et al. (1993) A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue, and a wearable control unit. Diabetologia 36: 658?663","journal-title":"Diabetologia"},{"key":"CR17","doi-asserted-by":"crossref","first-page":"2072","DOI":"10.1021\/ac00063a023","volume":"65","author":"F Moussy","year":"1993","unstructured":"Moussy F, Harrison DJ, O'Brien DW, Rajotte RV (1993) Peformance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating. Anal Chem 65: 2072?2077","journal-title":"Anal Chem"}],"container-title":["Diabetologia"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF00403381.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF00403381\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF00403381","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,4,3]],"date-time":"2019-04-03T22:18:54Z","timestamp":1554329934000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF00403381"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1994,6]]},"references-count":17,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1994,6]]}},"alternative-id":["BF00403381"],"URL":"https:\/\/doi.org\/10.1007\/bf00403381","relation":{},"ISSN":["0012-186X","1432-0428"],"issn-type":[{"value":"0012-186X","type":"print"},{"value":"1432-0428","type":"electronic"}],"subject":[],"published":{"date-parts":[[1994,6]]}}}