{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T20:26:49Z","timestamp":1692476809185},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[1979,1,1]],"date-time":"1979-01-01T00:00:00Z","timestamp":283996800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arch Otorhinolaryngol"],"published-print":{"date-parts":[[1979]]},"DOI":"10.1007\/bf00469751","type":"journal-article","created":{"date-parts":[[2004,11,15]],"date-time":"2004-11-15T18:20:39Z","timestamp":1100542839000},"page":"119-125","source":"Crossref","is-referenced-by-count":2,"title":["New parachute cuff and positive end-expiratory pressure to minimize tracheal injury and prevent aspiration"],"prefix":"10.1007","volume":"222","author":[{"given":"U.","family":"Nordin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L.","family":"Lyttkens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"CR1","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1111\/j.1399-6576.1977.tb01261.x","volume":"64","author":"U. Borg","year":"1977","unstructured":"Borg, U., Lyttkens, L., Nilsson, L.-G., Sj\u00f6strand, U.: Physiologic evaluation of the HFPPV pneumatic valve principle and PEEP. ? An experimental study. Acta Anaesthesiol. Scand. [Suppl.] 64, 37 (1977)","journal-title":"Acta Anaesthesiol. Scand. [Suppl.]"},{"key":"CR2","first-page":"657","volume":"12","author":"T. N. Finley","year":"1973","unstructured":"Finley, T. N., Abouav, J.: Self-inflating parachute cuff. Am. J. Surg. 12, 657 (1973)","journal-title":"Am. J. Surg."},{"key":"CR3","first-page":"3","volume-title":"Current problems in surgery","author":"H. C. Grillo","year":"1970","unstructured":"Grillo, H. C.: Surgery of the trachea. Current problems in surgery, p. 3. Chicago: Year book medical publishers, Inc. 1970"},{"key":"CR4","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1001\/archsurg.1967.01330070162034","volume":"94","author":"R. R. Jackson","year":"1967","unstructured":"Jackson, R. R., Rokowski, W. J.: An endotracheal tube with a cellophane cuff. Arch. Surg. 94, 160 (1967)","journal-title":"Arch. Surg."},{"key":"CR5","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/S0022-5223(20)31520-8","volume":"47","author":"H. E. Martinez","year":"1964","unstructured":"Martinez, H. E.: An improved cuffed tracheostomy tube for use with intermittent positive pressure breathing. J. Thorac. Cardiovasc. Surg. 47, 404 (1964)","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"CR6","first-page":"1926","volume":"71","author":"A. D. Merav","year":"1971","unstructured":"Merav, A. D.: Low-pressure ?parachute? endotracheal cuff. N.Y. State J. Med. 71, 1926 (1971)","journal-title":"N.Y. State J. Med."},{"key":"CR7","first-page":"345","volume":"Suppl.","author":"U. Nordin","year":"1977","unstructured":"Nordin, U.: The trachea and cuff-induced tracheal injury. An experimental study on causative factors and prevention. Acta Otolaryngol. [Suppl.] (Stockh.) 345 (1977)","journal-title":"Acta Otolaryngol."},{"key":"CR8","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1111\/j.1399-6576.1977.tb01198.x","volume":"21","author":"U. Nordin","year":"1977","unstructured":"Nordin, U., Lindholm, C.-E., Wolgast, M.: Blood flow in the rabbit tracheal mucosa under normal conditions and under the influence of tracheal intubation. Acta Anaesthesiol. Scand. 21, 81 (1977)","journal-title":"Acta Anaesthesiol. Scand."},{"key":"CR9","doi-asserted-by":"crossref","first-page":"455","DOI":"10.3109\/00016487609120933","volume":"82","author":"U. Nordin","year":"1976","unstructured":"Nordin, U., Lyttkens, L.: New self-adjusting cuff for tracheal tubes. Acta Otolaryngol. (Stockh.) 82, 455 (1976)","journal-title":"Acta Otolaryngol. (Stockh.)"},{"key":"CR10","first-page":"12","volume":"42","author":"L. Nordstr\u00f6m","year":"1972","unstructured":"Nordstr\u00f6m, L.: On automatic ventilation. Acta Anaesthesiol. Scand. [Suppl.] 42, 12 (1972)","journal-title":"Acta Anaesthesiol. Scand. [Suppl.]"},{"key":"CR11","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1111\/j.1399-6576.1976.tb05045.x","volume":"20","author":"B. Reven\u00e4s","year":"1976","unstructured":"Reven\u00e4s, B., Lindholm, C.-E.: Pressure and volume changes in tracheal tube cuffs during anesthesia. Acta Anaesthesiol. Scand. 20, 321 (1976)","journal-title":"Acta Anaesthesiol. Scand."},{"key":"CR12","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1111\/j.1399-6576.1977.tb01259.x","volume":"64","author":"U. Sj\u00f6strand","year":"1977","unstructured":"Sj\u00f6strand, U.: Review of the physiological rationale for and development of high-frequency positivepressure ventilation ? HFPPV. Acta Anaesthesiol. Scand. [Suppl.] 64, 7 (1977)","journal-title":"Acta Anaesthesiol. Scand. [Suppl.]"},{"key":"CR13","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1097\/00000542-197505000-00035","volume":"42","author":"T. H. Stanley","year":"1975","unstructured":"Stanley, T. H.: Nitrous oxide and pressures and volumes of high and low-pressure endotracheal-tube cuffs in intubated patients. Anesthesiology 42, 637 (1975)","journal-title":"Anesthesiology"}],"container-title":["Archives of Oto-Rhino-Laryngology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF00469751.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF00469751\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF00469751","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,28]],"date-time":"2021-06-28T15:22:17Z","timestamp":1624893737000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF00469751"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1979]]},"references-count":13,"journal-issue":{"issue":"2","published-print":{"date-parts":[[1979]]}},"alternative-id":["BF00469751"],"URL":"https:\/\/doi.org\/10.1007\/bf00469751","relation":{},"ISSN":["0302-9530","1434-4726"],"issn-type":[{"value":"0302-9530","type":"print"},{"value":"1434-4726","type":"electronic"}],"subject":[],"published":{"date-parts":[[1979]]}}}