{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T03:37:44Z","timestamp":1792121864737,"version":"4.4.0"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[1996,8,1]],"date-time":"1996-08-01T00:00:00Z","timestamp":838857600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neuroradiology"],"published-print":{"date-parts":[[1996,8]]},"DOI":"10.1007\/bf00626097","type":"journal-article","created":{"date-parts":[[2004,11,26]],"date-time":"2004-11-26T08:29:53Z","timestamp":1101457793000},"page":"555-559","source":"Crossref","is-referenced-by-count":25,"title":["Visualisation of intracranial aneurysms by transcranial duplex sonography"],"prefix":"10.1007","volume":"38","author":[{"given":"C.","family":"Kl\ufffdtzsch","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H. C.","family":"Nahser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B.","family":"Fischer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.","family":"Henkes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"K\ufffdhne","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Berlit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"CR1","doi-asserted-by":"crossref","first-page":"395","DOI":"10.7863\/jum.1993.12.7.395","volume":"12","author":"G Becker","year":"1993","unstructured":"Becker G, Lindner A, Bogdahn U (1993) Imaging of the vertebrobasilar system by transcranial colour-coded real-time sonography. J Ultrasound Med 12:395?401","journal-title":"J Ultrasound Med"},{"key":"CR2","doi-asserted-by":"crossref","first-page":"776","DOI":"10.3171\/jns.1993.78.5.0776","volume":"78","author":"M Sch\u00f6ning","year":"1993","unstructured":"Sch\u00f6ning M, Buchholz R, Walter J (1993) Comparative study of transcranial colour duplex sonography and transcranial Doppler sonography in adults. J Neurosurg 78:776?784","journal-title":"J Neurosurg"},{"key":"CR3","doi-asserted-by":"crossref","first-page":"1680","DOI":"10.1161\/01.STR.21.12.1680","volume":"21","author":"U Bogdahn","year":"1990","unstructured":"Bogdahn U, Becker G, Winkler J, Greiner K, Perez J, Meurers B (1990) Transcranial colour-coded real time sonography in adults. Stroke 21:1680?1688","journal-title":"Stroke"},{"key":"CR4","first-page":"497","volume":"12","author":"T Tsuchiya","year":"1991","unstructured":"Tsuchiya T, Yasaka M, Yamaguchi T, Kimura K, Omae T (1991) Imaging of the basal cerebral arteries and measurement of blood velocity in adults by using transcranial real-time colour flow Doppler sonography. AJNR 12:497?502","journal-title":"AJNR"},{"key":"CR5","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1161\/01.STR.25.2.390","volume":"25","author":"PJ Martin","year":"1994","unstructured":"Martin PJ, Evans DH, Naylor AR (1994) Transcranial colour-coded sonography of the basal cerebral circulation. Reference data from 115 volunteers. Stroke 25:390?396","journal-title":"Stroke"},{"key":"CR6","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1007\/BF00593046","volume":"32","author":"GM Becker","year":"1990","unstructured":"Becker GM, Winkler J, Hoffmann E, Bogdahn U (1990) Imaging of cerebral arteriovenous malformations by transcranial colour-coded real-time sonography. Neuroradiology 32:280?288","journal-title":"Neuroradiology"},{"key":"CR7","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1227\/00006123-199209000-00006","volume":"31","author":"G Becker","year":"1992","unstructured":"Becker G, Perez J, Krone A, Demuth K, Lindner A, Hofmann E, Winkler J, Bogdahn U (1992) Transcranial colourcoded real time sonography in the evaluation of intracranial neoplasms and arteriovenous malformations. Neurosurgery 31:420?428","journal-title":"Neurosurgery"},{"key":"CR8","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1227\/00006123-199106000-00005","volume":"28","author":"G Becker","year":"1991","unstructured":"Becker G, Greiner K, Kaune B, Winkler J, Brawanski A, Warmuth-Metz M, Bogdahn U (1991) Diagnosis and monitoring of subarachnoidal hemorrhage by transcranial colour-coded real-time sonography. Neurosurgery 28:814?820","journal-title":"Neurosurgery"},{"key":"CR9","doi-asserted-by":"crossref","first-page":"636","DOI":"10.3171\/jns.1988.68.4.0635","volume":"68","author":"KL Black","year":"1988","unstructured":"Black KL, Rubin JM, Chandler WF, McGillicuddy JE (1988) Intraoperative colour-flow Doppler imaging of AVM's and aneurysms. J Neurosurgery 68:636?639","journal-title":"J Neurosurgery"},{"key":"CR10","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1159\/000108510","volume":"4","author":"C Kl\u00f6tzsch","year":"1994","unstructured":"Kl\u00f6tzsch C, K\u00fchne D, Berlit P (1994) Diagnosis of giant fusiform basilar aneurysm by colour-coded transcranial duplex sonography. Cerebrovasc Dis 4: 371?372","journal-title":"Cerebrovasc Dis"},{"key":"CR11","doi-asserted-by":"crossref","first-page":"2429","DOI":"10.1161\/01.STR.25.12.2429","volume":"25","author":"RW Baumgartner","year":"1994","unstructured":"Baumgartner RW, Mattle HP, Kothbauer K, Schroth G (1994) Transcranial colour-coded Duplex sonography in cerebral aneurysms. Stroke 25:2429?2434","journal-title":"Stroke"},{"key":"CR12","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1055\/s-2008-1032408","volume":"160","author":"J Rieger","year":"1994","unstructured":"Rieger J, Hosten N, Lemke AJ, Langer R, Lanksch WR, Felix R (1994) Zerebrale Aneurysmen: dreidimensionale Darstellung mit der Spiral-CT. Fortschr R\u00f6ntgenstr 160:204?209","journal-title":"Fortschr R\u00f6ntgenstr"},{"key":"CR13","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1007\/BF00588131","volume":"36","author":"T Horikoshi","year":"1994","unstructured":"Horikoshi T, Fukamachi A, Nishi H, Fukasawa I (1994) Detection of intracranial aneurysms by three-dimensional time-of-flight magnetic resonance angiography. Neuroradiology 36:203?207","journal-title":"Neuroradiology"},{"key":"CR14","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/0090-3019(94)90394-8","volume":"42","author":"F Ikawa","year":"1994","unstructured":"Ikawa F, Sumida M, Uozumi T, Kuwabara S, Kiya K, Kurisu K, Arita K, Satoh H (1994) Comparison of three-dimensional phase-contrast magnetic resonance angiography with three-dimensional time-of-flight magnetic resonance angiography in cerebral aneurysms. Surg Neurol 42:287?292","journal-title":"Surg Neurol"},{"key":"CR15","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1007\/BF00612115","volume":"36","author":"N Bontozoglou","year":"1994","unstructured":"Bontozoglou N, Spanos H, Lasjaunias P, Zarifis G (1994) Three-dimensional display of the orifice of intracranial ancurysms: a new potential application for magnetic resonance angiography. Neuroradiology 36:346?349","journal-title":"Neuroradiology"},{"key":"CR16","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1161\/01.STR.24.5.676","volume":"24","author":"U Bogdahn","year":"1993","unstructured":"Bogdahn U, Becker G, Schlief R, Reddig J, Hassel W (1993) Contrast-enhanced transcranial colour-coded realtime sonography. Results of a phasetwo study. Stroke 24:676?684","journal-title":"Stroke"},{"key":"CR17","first-page":"721","volume":"26","author":"B Griewing","year":"1995","unstructured":"Griewing B, Doherty C, Kessler C (1995) Power-Doppler ? A new tool for transcranial duplex assessment of intracranial vasculature (abstract). Stroke 26:721","journal-title":"Stroke"}],"container-title":["Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF00626097.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF00626097\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF00626097","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,4]],"date-time":"2020-04-04T09:18:25Z","timestamp":1585991905000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF00626097"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,8]]},"references-count":17,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1996,8]]}},"alternative-id":["BF00626097"],"URL":"https:\/\/doi.org\/10.1007\/bf00626097","relation":{},"ISSN":["0028-3940","1432-1920"],"issn-type":[{"value":"0028-3940","type":"print"},{"value":"1432-1920","type":"electronic"}],"subject":[],"published":{"date-parts":[[1996,8]]}}}