{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T22:29:47Z","timestamp":1767652187326},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[1989,1,1]],"date-time":"1989-01-01T00:00:00Z","timestamp":599616000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neuroradiology"],"published-print":{"date-parts":[[1989]]},"DOI":"10.1007\/bf00698843","type":"journal-article","created":{"date-parts":[[2004,11,30]],"date-time":"2004-11-30T07:04:22Z","timestamp":1101798262000},"page":"148-150","source":"Crossref","is-referenced-by-count":9,"title":["High-dose contrast-enhanced computed tomography (CECT) with iopamidol in the detection of cerebral metastases"],"prefix":"10.1007","volume":"31","author":[{"given":"M.","family":"Leonardi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Lavaroni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E.","family":"Biasizzo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Fabris","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Penco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Zappoli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"CR1","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1259\/0007-1285-46-552-1023","volume":"46","author":"J Ambrose","year":"1972","unstructured":"Ambrose J (1972) Computerized transverse axial scanning (tomography). Part 2: Clinical application. Br J Radiol 46: 1023","journal-title":"Br J Radiol"},{"key":"CR2","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1259\/0007-1285-47-561-530","volume":"47","author":"R Paxton","year":"1974","unstructured":"Paxton R, Ambrose J (1974) The EMI scanner. A brief review of the first 650 patients Br J Radiol 47: 530","journal-title":"Br J Radiol"},{"key":"CR3","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1148\/110.1.109","volume":"110","author":"PF New","year":"1974","unstructured":"New PF, Scott WR, Schnur JA, Davies KR, Taveras JM (1974) Computerized axial tomography with EMI scanner. Radiology 110: 109","journal-title":"Radiology"},{"key":"CR4","first-page":"51","volume-title":"Contrast media: Biologic effects and clinical application, vol III","author":"A-K Behrooz","year":"1987","unstructured":"Behrooz A-K, Fine M (1987) Application and complications of contrast media in cerebral computed tomography. In: Parvez Z, Moncada R, Sovak M (eds) Contrast media: Biologic effects and clinical application, vol III. CRC Press, Boca Raton, p 51"},{"key":"CR5","unstructured":"Ethier R, Scerwin A, Taylor S (1974) Comuterized angiotomography. The use of 100 cc hypaque 60%. Clinical and experimental results. Presented at First Int Symp Comput Axial Tomogr, Montreal"},{"key":"CR6","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1148\/116.3.641","volume":"116","author":"RA Kramer","year":"1975","unstructured":"Kramer RA, Janetos GP, Perlstein G (1975) An approach to contrast enhancement in computed tomography of the brain. Radiology 116: 641","journal-title":"Radiology"},{"key":"CR7","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1097\/00004728-198202000-00007","volume":"6","author":"R Raimoko","year":"1982","unstructured":"Raimoko R, Majurin ML, Virtama P, Kangasneimi P (1982) Value of high contrast medium dose in brain CT. J Comput Assist Tomogr 6: 54","journal-title":"J Comput Assist Tomogr"},{"key":"CR8","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1148\/radiology.139.2.7220885","volume":"139","author":"PK Shalen","year":"1981","unstructured":"Shalen PK, Hayman CA, Wallace S, Handel SF (1981) Protocol for delayed contrast enhancement in computed tomography of cerebral neoplasia. Radiology 139: 397","journal-title":"Radiology"},{"key":"CR9","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1007\/BF00395357","volume":"16","author":"Y Inaba","year":"1978","unstructured":"Inaba Y, Hiratsuku H, Tsuyumu M, Fujiwara K, Takei H, Oie K, Yamaguchi T, Takasato Y (1978) Sequential delayed enhanced CT in brain tumors. Neuroradiology 16: 549","journal-title":"Neuroradiology"},{"key":"CR10","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1259\/0007-1285-52-620-620","volume":"52","author":"MR Paling","year":"1979","unstructured":"Paling MR (1979) Contrast dose for enhancement of computed tomograms of the brain. Br J Radiol 52: 62","journal-title":"Br J Radiol"},{"key":"CR11","unstructured":"Leonardi M, Zappoli F, Biasizzo E (1987) Lo studio CT per la ricerca di metastasi con alte dosi di mezzo di contrasto. L'efficacia. Proc Meet Tomografia computerizzata e mezzi di contrasto oggi: quando e perch\u00e8. Milano, October 23?24, 1987"},{"key":"CR12","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1148\/radiology.137.2.7433668","volume":"137","author":"WR Scott","year":"1980","unstructured":"Scott WR (1980) Seizures: a reaction to contrast media for computed tomography of the brain. Radiology 137: 359","journal-title":"Radiology"},{"key":"CR13","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1001\/archneur.1977.00500220083019","volume":"34","author":"JC Lozito","year":"1977","unstructured":"Lozito JC (1977) Convulsions: a complication of contrast enhancement and computerized tomography. Arch Neurol 34: 649","journal-title":"Arch Neurol"},{"key":"CR14","doi-asserted-by":"crossref","first-page":"832","DOI":"10.2214\/ajr.119.4.832","volume":"119","author":"DM Witten","year":"1973","unstructured":"Witten DM, Hirsch FD, Hartman GW (1973) Acute reactions to urographic contrast medium. AJR 119: 832","journal-title":"AJR"},{"key":"CR15","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1148\/radiology.137.2.7433693","volume":"137","author":"HW Fischer","year":"1980","unstructured":"Fischer HW (1980) Occurrence of seizures during cranial computed tomography. Radiology 137: 563","journal-title":"Radiology"},{"key":"CR16","first-page":"25","volume":"7","author":"M Langer","year":"1987","unstructured":"Langer M, Felix L, Behrends B, Eichstadt H (1987) Anwendung nichtomscher Kontrastmittel in der Computertomographie. Digit Bilddiagn 7: 25","journal-title":"Digit Bilddiagn"},{"key":"CR17","first-page":"141","volume":"30","author":"HW Fischer","year":"1981","unstructured":"Fischer HW, Plewes D, Violante M (1981) Contrast media, the blood-brain barrier, and cerebrail flow. Adv Neurol 30: 141","journal-title":"Adv Neurol"},{"key":"CR18","first-page":"72","volume":"366","author":"IO Skalpe","year":"1983","unstructured":"Skalpe IO (1983) Enhancement with water-soluble contrast media in computed tomography of the brain and abdomen. Survey and present state. Acta Radiol [Suppl] 366: 72","journal-title":"Acta Radiol [Suppl]"},{"key":"CR19","first-page":"326","volume":"4","author":"IO Skalpe","year":"1983","unstructured":"Skalpe IO, Hordvik M (1983) Comparison of side effects during cerebral computed tomography with a non ionic (iohexol) and an ionic (metrizoate) contrast medium AJNR 4: 326","journal-title":"AJNR"},{"key":"CR20","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1007\/BF00399773","volume":"24","author":"S Holtes","year":"1983","unstructured":"Holtes S, Cronqvist S, Renaa T (1983) Contrast enhanced brain CT. Comparison between iohexol and metrizoate. Neuroradiology 24: 213","journal-title":"Neuroradiology"},{"key":"CR21","first-page":"156","volume":"118","author":"H Tschakrt","year":"1983","unstructured":"Tschakrt H (1983) Contrast medium tolerance in computed tomography. Rofo [Suppl] 118: 156","journal-title":"Rofo [Suppl]"},{"key":"CR22","doi-asserted-by":"crossref","first-page":"185","DOI":"10.2214\/ajr.147.1.185","volume":"147","author":"MN Bagg","year":"1986","unstructured":"Bagg MN, Horwitz TA, Berter L (1986) Comparison of patient responses to high-and low-osmolality contrast agents injected intravenously. AJR 147: 185","journal-title":"AJR"},{"key":"CR23","first-page":"81","volume":"6","author":"P Bonati","year":"1981","unstructured":"Bonati P, Porrati GC, Rolandi G (1981) Iopamiro and uromiro 300 in brain CAT: a double-blind study. Rays 6: 81","journal-title":"Rays"},{"key":"CR24","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1097\/00004424-198701000-00008","volume":"22","author":"RG Ramsey","year":"1987","unstructured":"Ramsey RG, Czervionke L, Dommers M, James ME, Huckman MS, Russel EJ (1987) Safety and efficacy of sodium and meglumine ioxaglate (hexabrix) and hypaque M 60% in contrast enhanced computed cranial tomographic scanning. A double blind clinical study. Invest Radiol 22: 56","journal-title":"Invest Radiol"},{"key":"CR25","first-page":"67","volume":"4","author":"JJ Pagani","year":"1983","unstructured":"Pagani JJ, Hayman LA, Bigelow RH, Libshitz HI, Lepke RA, Wallace S (1983) Diazepam prophylaxis of contrast media-induced seizures during computed tomography of patients with brain metastases. AJNR 4: 67","journal-title":"AJNR"},{"key":"CR26","doi-asserted-by":"crossref","first-page":"449","DOI":"10.7326\/0003-4819-94-4-449","volume":"94","author":"EA Neuwelt","year":"1981","unstructured":"Neuwelt EA, Diehler JT, Vu LH, Hill SA, Michael AJ, Frankel EP (1981) Monitoring of methotrexate delivery in patients with malignant brain tumors after osmotic blood-brain barriers disruption. Ann Int Med 94: 449","journal-title":"Ann Int Med"},{"key":"CR27","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1097\/00004424-197003000-00001","volume":"5","author":"KF Limpke","year":"1970","unstructured":"Limpke KF, James G, Erhesfeld M (1970) Cerebrovascular permeability of a water-soluble contrast material, hypaque (sodium diatrizoate). Experimental study in dogs. Invest Radiol 5: 79","journal-title":"Invest Radiol"},{"key":"CR28","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1177\/000331976001100318","volume":"11","author":"JO Hoffa","year":"1960","unstructured":"Hoffa JO, Archer S (1960) X-ray contrast media for cardiovascular angiography. Angiology 11: 244","journal-title":"Angiology"},{"key":"CR29","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1111\/j.1399-6576.1983.tb01952.x","volume":"27","author":"A Rudehili","year":"1983","unstructured":"Rudehili A, Gordon E, Grepe A, Widen L (1983) The epileptogenicity of neuroleptanaesthesia in patients during and after neuroradiological examinations with metrizamide. Acta Anaesthesiol Scand 27: 285","journal-title":"Acta Anaesthesiol Scand"},{"key":"CR30","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1136\/jnnp.50.2.221","volume":"50","author":"E Avrahami","year":"1987","unstructured":"Avrahami E, Weiss-Peretz J, Cohn DF (1987) Focal epileptic activity following intravenous contrast material injection in patients with metastatic brain disease. J Neurol Neurosurg Psychiatry 50: 221","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"CR31","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1016\/S0022-3476(87)80197-X","volume":"111","author":"HA Haslam","year":"1987","unstructured":"Haslam HA, Cochrene DD, Amundson GM, Johns RD (1987) Neurotoxic complications of contrast computed tomography in children. J Pediatr 111: 837","journal-title":"J Pediatr"},{"key":"CR32","first-page":"474","volume":"26","author":"P Nakstod","year":"1984","unstructured":"Nakstod P, Helgetreit A, Aeserud O, Ganes T, Nylerg-Hansen R (1984) Iohexol compared to metrizamide in cervical and thoracic myelography. A randomized double-blind parallel study. Neuroradiolgy 26: 474","journal-title":"Neuroradiolgy"},{"key":"CR33","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1007\/BF00341838","volume":"30","author":"E Carchietti","year":"1988","unstructured":"Carchietti E, Baldassarre M, Penco T, Leonardi M (1988) Iopamidol 300-induced epilepsy. Intensive treatment and pathogenic hypothesis. A case report. Neuroradiology 30: 256","journal-title":"Neuroradiology"}],"container-title":["Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF00698843.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF00698843\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF00698843","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,4,5]],"date-time":"2019-04-05T06:01:07Z","timestamp":1554444067000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF00698843"}},"subtitle":["Tolerance of the contrast agent"],"short-title":[],"issued":{"date-parts":[[1989]]},"references-count":33,"journal-issue":{"issue":"2","published-print":{"date-parts":[[1989]]}},"alternative-id":["BF00698843"],"URL":"https:\/\/doi.org\/10.1007\/bf00698843","relation":{},"ISSN":["0028-3940","1432-1920"],"issn-type":[{"value":"0028-3940","type":"print"},{"value":"1432-1920","type":"electronic"}],"subject":[],"published":{"date-parts":[[1989]]}}}