{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T19:20:31Z","timestamp":1785612031971,"version":"3.56.0"},"reference-count":20,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[1995,7,1]],"date-time":"1995-07-01T00:00:00Z","timestamp":804556800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Knee surg. sports traumatol. arthrosc."],"published-print":{"date-parts":[[1995,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A randomized prospective study was carried out to compare one\u2010portal endoscopic carpal tunnel release with an open procedure. There were 47 patients (mean age 52.6 years): 25 underwent an endoscopic and 22 an open release. The aim of the study was to evaluate the risks against the benefits for pain, grip, key\u2010pinch strength and ability to return to work. The distribution of age, occupation, sex, neurographic findings and operated hand was similar in both groups. We detected no serious nerve complications. One \u201copen\u201d patient developed a hypertrophic scar, a second \u201copen\u201d patient a disabling reflex sympathetic dystrophy, one \u201cendo\u201d patient a transient neurapraxia. The remaining patients experienced complete relief of symptoms. Improvement of grip strength is significantly better after endoscopic release (<jats:italic>P<\/jats:italic>=0.0001 at 3\u00a0months). In contrast, the key\u2010pinch showed a similar pattern of improvement in both groups. The ability to use the operated hand as effectively as the contralateral one developed after 24\u00a0days for the endoscopic group versus 42 for the open approach (<jats:italic>P<\/jats:italic>=0.0000). The carpal arch alteration was less important for the endoscopic group (<jats:italic>P<\/jats:italic>= 0.013), but without any correlation with the grip strength. Agee's one\u2010portal technique only allows correct placement of a knife, not an inspection of the structures being operated upon. This is a major limitation, reducing the surgeon to a technician. Further development of this procedure demands a device that will enable a fruitful inspection of the carpal tunnel.<\/jats:p>","DOI":"10.1007\/bf01552386","type":"journal-article","created":{"date-parts":[[2005,4,27]],"date-time":"2005-04-27T15:29:58Z","timestamp":1114615798000},"page":"113-116","source":"Crossref","is-referenced-by-count":46,"title":["The value of one\u2010portal endoscopic carpal tunnel release: A prospective randomized study"],"prefix":"10.1002","volume":"3","author":[{"given":"G. R.","family":"Sennwald","sequence":"first","affiliation":[{"name":"<!--<label>1<\/label>--> Chirurgie St. Leonhard Pestalozzistrasse 2 CH\u20109000 St. Gallen Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Benedetti","sequence":"additional","affiliation":[{"name":"<!--<label>1<\/label>--> Chirurgie St. Leonhard Pestalozzistrasse 2 CH\u20109000 St. Gallen Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[1995,7]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(09)91044-9"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(94)90039-6"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(09)91047-4"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/0749-8063(89)90085-6"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(05)80426-8"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(94)90042-6"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(94)90038-8"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(94)90037-X"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(93)90090-P"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(09)91049-8"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(86)80144-7"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(94)90040-X"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(77)80009-9"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199402000-00015"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197355080-00019"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(09)91045-0"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-71622-5"},{"key":"e_1_2_1_19_2","first-page":"203","volume-title":"Injuries to the major branches of peripheral nerves of the forearm","author":"Spinner M","year":"1978"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(94)90041-8"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(09)91048-6"}],"container-title":["Knee Surgery, Sports Traumatology, Arthroscopy"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF01552386.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF01552386\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1007\/BF01552386","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T09:09:14Z","timestamp":1760864954000},"score":1,"resource":{"primary":{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/10.1007\/BF01552386"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1995,7]]},"references-count":20,"journal-issue":{"issue":"2","published-print":{"date-parts":[[1995,7]]}},"alternative-id":["10.1007\/BF01552386"],"URL":"https:\/\/doi.org\/10.1007\/bf01552386","archive":["Portico"],"relation":{},"ISSN":["0942-2056","1433-7347"],"issn-type":[{"value":"0942-2056","type":"print"},{"value":"1433-7347","type":"electronic"}],"subject":[],"published":{"date-parts":[[1995,7]]}}}