{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,3,29]],"date-time":"2022-03-29T01:43:42Z","timestamp":1648518222416},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1-2","license":[{"start":{"date-parts":[[1993,3,1]],"date-time":"1993-03-01T00:00:00Z","timestamp":730944000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta neurochir"],"published-print":{"date-parts":[[1993,3]]},"DOI":"10.1007\/bf02001470","type":"journal-article","created":{"date-parts":[[2005,8,11]],"date-time":"2005-08-11T12:37:02Z","timestamp":1123763822000},"page":"53-58","source":"Crossref","is-referenced-by-count":1,"title":["The acrylic-wire option in cervical spine fixation"],"prefix":"10.1007","volume":"120","author":[{"given":"A.","family":"Raco","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Di Lorenzo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Delfini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Ciappetta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Cantore","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"BF02001470_CR1","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1093\/neurosurgery\/27.CN_suppl_1.401","volume":"27","author":"E Alexander Jr","year":"1980","unstructured":"Alexander E Jr (1980) Decompression and fixation in cervical spine fractures: indications and techniques. Clin Neurosurg 27: 401\u2013413","journal-title":"Clin Neurosurg"},{"key":"BF02001470_CR2","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.2106\/00004623-197961080-00001","volume":"61","author":"LD Anderson","year":"1979","unstructured":"Anderson LD, D'Alonzo RT (1979) Fractures of the odontoid process of the axis. J Bone Joint Surg (Am) 61: 1119\u20131142","journal-title":"J Bone Joint Surg (Am)"},{"key":"BF02001470_CR3","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1227\/00006123-198910000-00002","volume":"25","author":"C Branch","year":"1989","unstructured":"Branch C, Kelly D, Davis C, McWhorter J (1989) Fixation of fractures of the lower cervical spine using methylmethacrylate and wire: technique and results in 99 patients. Neurosurgery 25: 503\u2013513","journal-title":"Neurosurgery"},{"key":"BF02001470_CR4","unstructured":"Cantore GP, Guidetti B, Moscatelli G (1969) A new antibiotic \u201cmastic\u201d in neurosurgery. IV. International Congress of Neurological Surgery, IX. International Congress of Neurology, New York, 20\u201327 Sept. 1969. Excerpta Medica International Congress Series 193, p46"},{"key":"BF02001470_CR5","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.3171\/jns.1984.60.5.1104","volume":"60","author":"GP Cantore","year":"1984","unstructured":"Cantore GP, Ciappetta P, Delfini R (1984) New steel device for occipital-cervical fixation. J Neurosurg 60: 1104\u20131106","journal-title":"J Neurosurg"},{"key":"BF02001470_CR6","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1227\/00006123-198910000-00001","volume":"25","author":"W Caspar","year":"1989","unstructured":"Caspar W, Barbier DD, Klara PM (1989) Anterior cervical fusion and Caspar plate stabilization for cervical trauma. Neurosurgery 25: 491\u2013502","journal-title":"Neurosurgery"},{"key":"BF02001470_CR7","doi-asserted-by":"crossref","first-page":"40","DOI":"10.2106\/00004623-198466010-00006","volume":"66","author":"CR Clark","year":"1984","unstructured":"Clark CR, Kegg KJ, Panjabi MM (1984) Methylmethacrylate stabilization of the cervical spine. J Bone Joint Surg (AM) 66: 40\u201346","journal-title":"J Bone Joint Surg (AM)"},{"key":"BF02001470_CR8","doi-asserted-by":"crossref","first-page":"603","DOI":"10.3171\/jns.1979.50.5.0603","volume":"50","author":"PR Cooper","year":"1979","unstructured":"Cooper PR, Maravilla KR, Sklar FH, Moddy SF, Clark WK (1979) Halo immobilization of cervical spine fractures. Indications and results. J Neurosurg 50: 603\u2013610","journal-title":"J Neurosurg"},{"key":"BF02001470_CR9","doi-asserted-by":"crossref","first-page":"39","DOI":"10.3171\/jns.1986.64.1.0039","volume":"64","author":"TA Duff","year":"1986","unstructured":"Duff TA (1986) Surgical stabilization of traumatic cervical spine dislocations using methylmethacrylate. Long-term results in 26 patients. J Neurosurg 64: 39\u201344","journal-title":"J Neurosurg"},{"key":"BF02001470_CR10","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1097\/00007632-197703000-00002","volume":"2","author":"EJ Dunn","year":"1977","unstructured":"Dunn EJ (1977) The role of methylmethacrylate in the stabilization and replacement of tumors of the cervical spine. Spine 2: 15\u201324","journal-title":"Spine"},{"key":"BF02001470_CR11","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1097\/00007632-198107000-00004","volume":"6","author":"FJ Eismont","year":"1981","unstructured":"Eismont FJ, Bohlman HH (1981) Posterior methylmethacrylate fixation of cervical trauma. Spine 6: 347\u2013353","journal-title":"Spine"},{"key":"BF02001470_CR12","doi-asserted-by":"crossref","first-page":"762","DOI":"10.3171\/jns.1986.65.6.0762","volume":"65","author":"JA Glaser","year":"1986","unstructured":"Glaser JA, Whitehill R, Stamp WG, Jane JA (1986) Complications associated with the halo-vest. A review of 245 cases. J Neurosurg 65: 762\u2013769","journal-title":"J Neurosurg"},{"key":"BF02001470_CR13","doi-asserted-by":"crossref","first-page":"380","DOI":"10.2106\/00004623-197557030-00017","volume":"57","author":"SS Haas","year":"1975","unstructured":"Haas SS, Brauer GH, Dickson G (1975) A characterization of polymethylmethacrylate bone cement. J Bone Joint Surg (Am) 57: 380\u2013391","journal-title":"J Bone Joint Surg (Am)"},{"key":"BF02001470_CR14","doi-asserted-by":"crossref","first-page":"606","DOI":"10.3171\/jns.1980.53.5.0606","volume":"53","author":"RR Hausebout","year":"1980","unstructured":"Hausebout RR, Blomquist GA Jr (1980) Acrylic spinal fusion. A 20 year clincal series and technical note. J Neurosurg 53: 606\u2013612","journal-title":"J Neurosurg"},{"key":"BF02001470_CR15","doi-asserted-by":"crossref","first-page":"366","DOI":"10.3171\/jns.1972.36.3.0366","volume":"36","author":"DL Kelly Jr","year":"1972","unstructured":"Kelly DL Jr, Alexander E Jr, Davis CH Jr, Smith JM (1972) Acrylic fixation of atlanto-axial dislocations. Technical note. J Neurosurg 36: 366\u2013367","journal-title":"J Neurosurg"},{"key":"BF02001470_CR16","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/S0140-6736(59)90560-4","volume":"2","author":"G Knight","year":"1959","unstructured":"Knight G (1959) Paraspinal acrylic inlays in the treatment of cervical and lumbar spondylosis and other conditions. Lancet 2: 147\u2013149","journal-title":"Lancet"},{"key":"BF02001470_CR17","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1007\/BF01401159","volume":"71","author":"F Lesoin","year":"1984","unstructured":"Lesoin F, Combelles G, Bouasakao N, Cama A, Dalandsheer JM, Jomin M (1984) Use of acrylic prosthesis in cervical spine pathology. Acta Neurochir (Wien) 71: 141\u2013149","journal-title":"Acta Neurochir (Wien)"},{"key":"BF02001470_CR18","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.2106\/00004623-198668080-00003","volume":"68","author":"PC McAfee","year":"1986","unstructured":"McAfee PC, Bohlman HH, Ducker T, Eismont FJ (1986) Failure of stabilization of the spine with methylmethacrylate. J Bone Joint Surg (Am) 68: 1145\u20131157","journal-title":"J Bone Joint Surg (Am)"},{"key":"BF02001470_CR19","first-page":"2847","volume-title":"Osteosynthese du rachis cervical superieur","author":"R Roy-Camille","year":"1972","unstructured":"Roy-Camille R, Saillant G (1972) Chirurgie du rachis cervical 4. Osteosynthese du rachis cervical superieur. Nouv Press Med (Paris), pp 2847\u20132849"},{"key":"BF02001470_CR20","doi-asserted-by":"crossref","first-page":"274","DOI":"10.3171\/jns.1967.27.3.0274","volume":"27","author":"WB Scoville","year":"1967","unstructured":"Scoville WB, Palmer AH, Samra K (1967) The use of acrylic plastic for vertebral replacement or fixation in metastatic disease of the spine. J Neurosurg 27: 274\u2013279","journal-title":"J Neurosurg"},{"key":"BF02001470_CR21","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1227\/00006123-198103000-00008","volume":"8","author":"E Six","year":"1981","unstructured":"Six E, Kelly DL Jr (1981) Technique for C1\u2013C2 and C3 fixation on cases of odontoid fracture. Neurosurgery 8: 374\u2013377","journal-title":"Neurosurgery"},{"key":"BF02001470_CR22","doi-asserted-by":"crossref","first-page":"421","DOI":"10.2106\/00004623-197759030-00028","volume":"59","author":"JP Taitsman","year":"1977","unstructured":"Taitsman JP, Saha S (1977) Tensile strength of wire reinforced bone cement and twisted stainless steel wire. J Bone Joint Surg (Am) 59: 421\u2013425","journal-title":"J Bone Joint Surg (Am)"},{"key":"BF02001470_CR23","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1097\/00003086-197506000-00011","volume":"109","author":"AA White","year":"1975","unstructured":"White AA, Johnson RM, Panjabi MM, Southwick WO (1975) Biochmechanical analysis of clinical stability in the cervical spine. Clin Orthop 109: 85\u201396","journal-title":"Clin Orthop"},{"key":"BF02001470_CR24","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1097\/00007632-198404000-00004","volume":"9","author":"R Whitehill","year":"1984","unstructured":"Whitehill R, Reger S, Fox E, Payne R, Buny J, Cole C, Richman J, Bruce J (1984) The use of methylmethacrylate cement as an instantaneous fusion mass in posterior cervical fusions: a canine in vivo experimental model. Spine 9: 246\u2013252","journal-title":"Spine"},{"key":"BF02001470_CR25","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/00007632-198501000-00006","volume":"10","author":"R Whitehill","year":"1985","unstructured":"Whitehill R, Barry JC (1985) The evolution of stability in cervical constructs using either autogenous bone graft or methylmethacrylate cement. A follow-up report on a canine in vivo model. Spine 10: 31\u201341","journal-title":"Spine"},{"key":"BF02001470_CR26","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1097\/00007632-198701000-00003","volume":"12","author":"R Whitehill","year":"1987","unstructured":"Whitehill R, Stowers SF, Fechner RE, Ruch WW, Drucker S, Gibson LR, McKernan DJ, Widemeyer JA (1987) Posterior cervical fixations using cerclage wires, methylmethacrylate cement and autogenous bone graft. An experimental study of a canine model. Spine 12: 12\u201322","journal-title":"Spine"},{"key":"BF02001470_CR27","doi-asserted-by":"crossref","first-page":"576","DOI":"10.3171\/jns.1988.68.4.0576","volume":"68","author":"R Whitehill","year":"1988","unstructured":"Whitehill R, Cicoria AD, Hooper WE, Maggio WW, Jane JA (1988) Posterior cervical reconstruction with methylmethacrylate and wire: a clinical review. J Neurosurg 68: 576\u2013584","journal-title":"J Neurosurg"}],"container-title":["Acta Neurochirurgica"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF02001470.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF02001470\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF02001470","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,14]],"date-time":"2019-05-14T11:15:43Z","timestamp":1557832543000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF02001470"}},"subtitle":["A retrospective study"],"short-title":[],"issued":{"date-parts":[[1993,3]]},"references-count":27,"journal-issue":{"issue":"1-2","published-print":{"date-parts":[[1993,3]]}},"alternative-id":["BF02001470"],"URL":"https:\/\/doi.org\/10.1007\/bf02001470","relation":{},"ISSN":["0001-6268","0942-0940"],"issn-type":[{"value":"0001-6268","type":"print"},{"value":"0942-0940","type":"electronic"}],"subject":[],"published":{"date-parts":[[1993,3]]}}}