{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T15:33:34Z","timestamp":1760888014124},"reference-count":50,"publisher":"Springer Science and Business Media LLC","issue":"S1","license":[{"start":{"date-parts":[[1999,1,1]],"date-time":"1999-01-01T00:00:00Z","timestamp":915148800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Infection"],"published-print":{"date-parts":[[1999,1]]},"DOI":"10.1007\/bf02561611","type":"journal-article","created":{"date-parts":[[2007,2,8]],"date-time":"2007-02-08T08:46:34Z","timestamp":1170924394000},"page":"S11-S15","source":"Crossref","is-referenced-by-count":16,"title":["Prevention of infections caused by central venous catheters-established and novel measures"],"prefix":"10.1007","volume":"27","author":[{"given":"A.","family":"Bach","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"BF02561611_CR1","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1172\/JCI111305","volume":"73","author":"W. Zimmerli","year":"1984","unstructured":"Zimmerli, W., Lew, P. D., Waldvogel, F. A.: Pathogenesis of foreign body infections: evidence for a local granulocyte defect. J. Clin. Invest. 73 (1984) 1191\u20131200.","journal-title":"J. Clin. Invest."},{"issue":"Suppl. 3b","key":"BF02561611_CR2","doi-asserted-by":"crossref","first-page":"197S","DOI":"10.1016\/0002-9343(91)90369-9","volume":"91","author":"L. A. Mermel","year":"1991","unstructured":"Mermel, L. A., McCormick R. D., Springman, S. R., Maki, D. G.: The pathogenesis and epidemiology of catheter-related infection with pulmonary artery Swan-Ganz catheters: a prospective study utilizing molecular subtyping. Am. J. Med. 91 (1991) (Suppl. 3b) 197S-205S.","journal-title":"Am. J. Med."},{"key":"BF02561611_CR3","first-page":"161","volume-title":"Infections associated with indwelling medical devices","author":"D. G. Maki","year":"1989","unstructured":"Maki, D. G.: Pathogenesis, prevention, and management of infections due to intravascular devices used for infusion therapy. In:Bisno, A. L., Waldvogel, F. A. (eds.): Infections associated with indwelling medical devices. American Society for Microbiology, Washington 1989, 161\u2013177."},{"key":"BF02561611_CR4","first-page":"355","volume":"97","author":"A. Sitges-Serra","year":"1985","unstructured":"Sitges-Serra, A., Linares, J., Garau, J.: Catheter sepsis; the clue is the hub. Surgery 97 (1985) 355\u2013357.","journal-title":"Surgery"},{"key":"BF02561611_CR5","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1177\/0148607191015002173","volume":"15","author":"J. H. Chuang","year":"1991","unstructured":"Chuang, J. H., Chuang, S. F.: Implication of a distant septic focus in parenteral nutrition catheter colonization. J. Parenteral Enteral Nutr. 15 (1991) 173\u2013175.","journal-title":"J. Parenteral Enteral Nutr."},{"key":"BF02561611_CR6","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1056\/NEJM197706092962301","volume":"296","author":"D. G. Maki","year":"1977","unstructured":"Maki, D. G., Weise, C. E., Sarafin, H. W.: A semiquantitative culture method for identifying intravenous catheter-related infection. N. Engl. J. Med. 296 (1977) 1305\u20131309.","journal-title":"N. Engl. J. Med."},{"key":"BF02561611_CR7","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/0732-8893(92)90052-U","volume":"15","author":"I. I. Raad","year":"1992","unstructured":"Raad, I. I., Sabbagh, M. F., Rand, K. H., Sherertz, R. J.: Quantitative tip culture methods and the diagnosis of central venous catheter-related infections. Diagn. Microbiol. Infect. Dis. 15 (1992) 13\u201320.","journal-title":"Diagn. Microbiol. Infect. Dis."},{"key":"BF02561611_CR8","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1055\/s-2007-998954","volume":"28","author":"A. Bach","year":"1993","unstructured":"Bach, A., B\u00f6hrer, H.: Infektionen durch intravasale Katheter. An\u00e4sthesiol. Intensivmed. Notfallmed. Schmerzther. 28 (1993) 404\u2013414.","journal-title":"Intensivmed. Notfallmed. Schmerzther."},{"key":"BF02561611_CR9","first-page":"150","volume":"193","author":"A. Bach","year":"1992","unstructured":"Bach, A., Geiss, H. K.: Microbiologic risk of replacing venous catheters by the guide-wire technique. Zentralbl. Hyg. 193 (1992) 150\u2013159.","journal-title":"Zentralbl. Hyg."},{"key":"BF02561611_CR10","first-page":"90","volume":"33","author":"C. A. DaRif","year":"1983","unstructured":"DaRif, C. A., Rush, H. G.: Management of septicemia in rhesus monkeys with chronic indwelling venous catheters. Lab. Anim. Sci. 33 (1983) 90\u201394.","journal-title":"Lab. Anim. Sci."},{"key":"BF02561611_CR11","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.1056\/NEJM199210083271505","volume":"327","author":"D. K. Cobb","year":"1992","unstructured":"Cobb, D. K., High, K. P., Sawyer, R. G., Sable, C. A., Adams, R. B., Lindley, D. A., Pruett, T. L., Schwenzer, K. J., Farr, B. M.: A controlled trial of scheduled replacement of central venous and pulmonary-artery catheters. N. Engl. J. Med. 327 (1992) 1062\u20131068.","journal-title":"N. Engl. J. Med."},{"key":"BF02561611_CR12","first-page":"104","volume":"21","author":"A. Bach","year":"1994","unstructured":"Bach, A., Motsch, J.: Praventionen von Infektionen durch intravasale Katheter\u2014Eine Literaturrecherche. Infusionsther. Transfusionmed. 21 (1994) 104\u2013114.","journal-title":"Infusionsther. Transfusionmed."},{"key":"BF02561611_CR13","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/0196-6553(83)90079-2","volume":"11","author":"B. P. Simmons","year":"1983","unstructured":"Simmons, B. P.: CDC guidelines for the prevention and control of nosocomial infections. Guideline for prevention of intravascular infections. Am. J. Infect. Control. 11 (1983) 183\u2013199.","journal-title":"Am. J. Infect. Control."},{"key":"BF02561611_CR14","doi-asserted-by":"crossref","first-page":"13","DOI":"10.2105\/AJPH.80.1.13","volume":"80","author":"W. Litsky","year":"1990","unstructured":"Litsky, W.: Wanted: plastics with antimicrobial properties. Am. J. Public Health 80 (1990) 13\u201315.","journal-title":"Am. J. Public Health"},{"key":"BF02561611_CR15","first-page":"33","volume":"7","author":"D. P. Halpin","year":"1991","unstructured":"Halpin, D. P., O'Byme, P., McEntee, G., Hennessy, T. P., Stephens, R. B.: Effect of betadine connection shield on central venous catheter sepsis. Nutrition 7 (1991) 33\u201334.","journal-title":"Nutrition"},{"key":"BF02561611_CR16","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1177\/0148607192016006581","volume":"16","author":"Y. Inoue","year":"1992","unstructured":"Inoue, Y., Nezu, R., Matsuda, H., Fujii, M., Nakai, S., Wasa, M., Takagi, Y., Okada, A.: Prevention of catheter-related sepsis during parenteral nutrition\u2014effect of a new connection device. J. Parenteral Enteral Nutr. 16 (1992) 581\u2013585.","journal-title":"J. Parenteral Enteral Nutr."},{"key":"BF02561611_CR17","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1128\/JCM.31.3.475-479.1993","volume":"31","author":"M. B. Salzman","year":"1993","unstructured":"Salzman, M. B., Isenberg, H. D., Rubin, L. G.: Use of disinfectants to reduce microbial contamination of hubs of vascular catheters. J. Clin. Microbiol. 31 (1993) 475\u2013479.","journal-title":"J. Clin. Microbiol."},{"key":"BF02561611_CR18","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1128\/AAC.33.8.1174","volume":"33","author":"R. J. Sherertz","year":"1989","unstructured":"Sherertz, R. J., Forman, D. M., Solomon, D. D.: Efficacy of dicloxacillin-coated polyurethane catheters in preventing subcutaneousStaphylococcus aureus infection in mice. Antimicrob. Agents Chemother. 33 (1989) 1174\u20131178.","journal-title":"Antimicrob. Agents Chemother."},{"key":"BF02561611_CR19","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1159\/000184366","volume":"46","author":"S. Z. Trooskin","year":"1987","unstructured":"Trooskin, S. Z., Donetz, A. P., Baxter, J., Harvey, R. A., Greco, R. S.: Infection-resistant continuous perifoneal dialysis catheters. Nephron 46 (1987) 263\u2013267.","journal-title":"Nephron"},{"key":"BF02561611_CR20","doi-asserted-by":"crossref","first-page":"2364","DOI":"10.1001\/jama.1991.03460180070035","volume":"265","author":"G. D. Kamal","year":"1991","unstructured":"Kamal, G. D., Pfaller, M. A., Rempe, L. E., Jebson, P. J.: Reduced intravascular catheter infection by antibiotic bonding. A prospective, randomized, controlled trial. JAMA 265 (1991) 2364\u20132368.","journal-title":"JAMA"},{"key":"BF02561611_CR21","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/0195-6701(91)90100-M","volume":"19","author":"B. Jansen","year":"1991","unstructured":"Jansen, B., Peters, G.: Modern strategies in the prevention of polymer-associated infections. J. Hosp. Infect. 19 (1991) 83\u201388.","journal-title":"J. Hosp. Infect."},{"key":"BF02561611_CR22","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/0195-6701(92)90093-2","volume":"22","author":"B. Jansen","year":"1992","unstructured":"Jansen, B., Jansen, S., Peters, G., Pulverer, G.:In-vitro efficacy of a central venous catheter (\u201cHydrocath\u201d) loaded with teicoplanin to prevent bacterial colonization. J. Hosp. Infect. 22 (1992) 93\u2013107.","journal-title":"J. Hosp. Infect."},{"key":"BF02561611_CR23","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1093\/infdis\/167.4.920","volume":"167","author":"L. A. Mermel","year":"1993","unstructured":"Mermel, L. A., Stolz, S. M., Marki, D. G.: Surface antimicrobial activity of heparin-bonded and antiseptic-impregnated vascular catheters. J. Infect. Dis. 167 (1993) 920\u2013924.","journal-title":"J. Infect. Dis."},{"key":"BF02561611_CR24","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/S0934-8840(11)80375-0","volume":"279","author":"G. Romano","year":"1993","unstructured":"Romano, G., Berti, M., Goldstein, B. P., Borghi, A.: Efficacy of a central venous catheter (Hydrocath\u00ae) loaded with teicoplanin in preventing subcutaneous styphylococcal infection in the mouse. Zentralbl. Bakteriol. 279 (1993) 426\u2013433.","journal-title":"Zentralbl. Bakteriol."},{"key":"BF02561611_CR25","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1093\/infdis\/167.1.98","volume":"167","author":"R. J. Sherertz","year":"1993","unstructured":"Sherertz, R. J., Carruth, W. A., Hampton, A. A., Byron, M. P., Solomon, D. D.: Efficacy of antibiotic-coated catheters in preventing subcutaneousStaphylococcus aureus infection in rabbits. J. Inf. Dis. 167 (1993) 98\u2013106.","journal-title":"J. Inf. Dis."},{"issue":"Suppl. 1","key":"BF02561611_CR26","first-page":"88","volume":"43","author":"B. Jansen","year":"1994","unstructured":"Jansen, B.: Der zentrale Venenkatheter\u2014Diagnostik und Pr\u00e4vention von Infektionen. Anaesthesist 43 (Suppl. 1) (1994) S 88.","journal-title":"Anaesthesist"},{"key":"BF02561611_CR27","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1017\/S0022172400065955","volume":"96","author":"D. Kingston","year":"1986","unstructured":"Kingston, D., Seal, D. V., Hill, I. D.: Self-disinfecting plastics for intravenous catheters and prothetic inserts. J. Hyg. Lond. 96 (1986) 185\u2013198.","journal-title":"J. Hyg. Lond."},{"key":"BF02561611_CR28","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/0195-6701(90)90116-6","volume":"16","author":"D. Kingston","year":"1990","unstructured":"Kingston, D., Hill, I. D.: Elution of disinfectant from polyurethane cannula tubing. J. Hosp. Infect. 16 (1990) 271\u2013280.","journal-title":"J. Hosp. Infect."},{"key":"BF02561611_CR29","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/0195-6701(92)90004-6","volume":"20","author":"D. Kingston","year":"1992","unstructured":"Kingston, D., Birnie, E. D. C., Martin, J., Pearce, P. C., Manek, S., Quinn, C. M.: Experimental pathology of intravenous polyurethane cannulae containing disinfectant. J. Hosp. Infect. 20 (1992) 257\u2013270.","journal-title":"J. Hosp. Infect."},{"key":"BF02561611_CR30","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1007\/978-1-4471-3454-1_60","volume-title":"Pathogenesis of wound and biomaterial-associated infections","author":"D. V. Seal","year":"1990","unstructured":"Seal, D. V., Barrett, S. P.: The development of irgasan-impregnated intravenous cannulae. In:Wadstr\u00f6m, T., Eliasson, I., Holder, I., Ljungh, A. (eds.) Pathogenesis of wound and biomaterial-associated infections. Springer, London Berlin Heidelberg New York 1990, 501\u2013506."},{"key":"BF02561611_CR31","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1093\/jac\/30.2.135","volume":"30","author":"B. Jansen","year":"1992","unstructured":"Jansen, B., Kristinsson, K. G., Jansen, S., Peters, G., Pulverer, G.:In-vitro efficacy of a central venous catheter (Secalon-Hydrocath\u00ae) complexed with iodine to prevent bacterial colonization. J. Antimicrob. Chemother. 30 (1992) 135\u2013139.","journal-title":"J. Antimicrob. Chemother."},{"key":"BF02561611_CR32","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1093\/jac\/31.2.261","volume":"31","author":"S. E. Tebbs","year":"1993","unstructured":"Tebbs, S. E., Elliott, T. S. J.: A novel antimicrobial central venous catheter impregnated with benzalkonium choloride. J. Antimicrob. Chemother. 31 (1993) 261\u2013271.","journal-title":"J. Antimicrob. Chemother."},{"key":"BF02561611_CR33","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/0002-9343(88)90579-7","volume":"85","author":"D. G. Maki","year":"1988","unstructured":"Maki, D. G., Cobb, L., Garman, J. K., Shapiro, J. M., Ringer, M., Helgerson, R. B.: An attachable silver-impregnated cuff for prevention of infection with central venous catheters: a prospective randomized multicenter trial. Am. J. Med. 85 (1988) 307\u2013314.","journal-title":"Am. J. Med."},{"key":"BF02561611_CR34","doi-asserted-by":"crossref","first-page":"878","DOI":"10.1001\/jama.1989.03420060094039","volume":"261","author":"R. Flower","year":"1989","unstructured":"Flower, R., Schwenzer, K. J., Kopel, R. F., Fisch, M. J., Tucker, S. I., Farr, B. M.: Efficacy of an attachable subcutaneous cuff for the prevention of intravascular catheter-related infection. A randomized, controlled trial. JAMA 261 (1989) 878\u2013883.","journal-title":"JAMA"},{"key":"BF02561611_CR35","first-page":"33","volume":"175","author":"S. Norwood","year":"1992","unstructured":"Norwood, S., Hajjar, G., Jenkins, L.: The influence of an attachable subcutaneous cuff for preventing triple lumen catheter infections in critically ill surgical and trauma patients. Surg. Gynecol. Obstet. 175 (1992) 33\u201340.","journal-title":"Surg. Gynecol. Obstet."},{"key":"BF02561611_CR36","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1177\/014860719301700161","volume":"17","author":"C. R. Babycos","year":"1993","unstructured":"Babycos, C. R., Barrocas, A., Webb, W. R.: A prospective randomized trial comparing the silver-impregnated collagen cuff with bedside tunneled subclavian catheters. J. Parenteral Enteral Nutr. 17 (1993) 61\u201363.","journal-title":"J. Parenteral Enteral Nutr."},{"key":"BF02561611_CR37","unstructured":"Clementi, E., Marie, O., Arlet, G.: Usefulness of an attachable silverimpregnated cuff for prevention of catheter-related sepsis? Abstracts of the 31st Interscience Conference on Antimicrobial Agents and Chemotherapy, Washington, 1991, abstr. 460."},{"key":"BF02561611_CR38","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1097\/00000658-199308000-00014","volume":"218","author":"J. S. Groeger","year":"1993","unstructured":"Groeger, J. S., Lucas, A. B., Coit, D., La, Quaglia, M., Brown, A. E., Turnbull, A., Exelby, P.: A prospective, randomized evauluation of the effect of silver impregnated subcutaneous cuffs for preventing tunneled chronic venous access catheter infections in cancer patients. Ann. Surg. 218 (1993) 206\u2013210.","journal-title":"Ann. Surg."},{"key":"BF02561611_CR39","first-page":"23","volume":"11","author":"S. M. Modak","year":"1992","unstructured":"Modak, S. M., Sampath, I.: Development and evaluation of a new polyurethane central venous antiseptic catheter: reducing central venous catheter infections. Complications Surgery 11 (1992) 23\u201329.","journal-title":"Complications Surgery"},{"issue":"Suppl.","key":"BF02561611_CR40","first-page":"99","volume":"19","author":"D. G. Maki","year":"1991","unstructured":"Maki, D. G., Wheeler, S. J., Stolz, S. M.: Study of a novel antisepticcoated central venous catheter. Crit. Care Med. 19 (Suppl.) (1991) S 99.","journal-title":"Crit. Care Med."},{"key":"BF02561611_CR41","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1006\/jsre.1993.1197","volume":"55","author":"A. Bach","year":"1993","unstructured":"Bach, A., B\u00f6hrer, H., Martin, E., Geiss, H. K., Sonntag, H. G.: Prevention of catheter-related infections by antiseptic surface bonding. J. Surg. Res. 55 (1993) 640\u2013646.","journal-title":"J. Surg. Res."},{"key":"BF02561611_CR42","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1093\/jac\/33.5.969","volume":"33","author":"A. Bach","year":"1994","unstructured":"Bach, A., B\u00f6hrer, H., Motsch, J., Martin, E., Geiss, H. K., Sonntag, H. G.: Prevention of bacterial colonization of intravenous catheters by antiseptic impregnation of polyurethane polymers. J. Antimicrobial Chemother. 33 (1994) 969\u2013978.","journal-title":"J. Antimicrobial Chemother"},{"key":"BF02561611_CR43","first-page":"294","volume":"76","author":"A. Bach","year":"1993","unstructured":"Bach, A., B\u00f6hrer, H., Motsch, J., Martin, E., Sonntag, H. G.: Prevention of colonization of central venous catheters by silver-sulfadiazine-chlorhexidine (SSC) bonding: a pilot study in critical care patients. Anesthesiology 76 (1993) A 294","journal-title":"Anesthesiology"},{"key":"BF02561611_CR44","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/00003246-199401000-00216","volume":"22","author":"J. Ramsay","year":"1994","unstructured":"Ramsay, J., Nolte, F., Schwarzmann, S.: Incidence of catheter colonization and catheter related infections with an antiseptic impregnanted triple lumen catheter. Crit. Care Med. 22 (1994) A 115.","journal-title":"Crit. Care Med."},{"key":"BF02561611_CR45","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1177\/088532829400900103","volume":"9","author":"B. Jansen","year":"1994","unstructured":"Jansen, B., Rinck, M., Wolbring, P., Strohmeier, A., Johns, T.:In vitro evaluation of the antimicrobial efficacy and biocompatibility of silver-coated central venous catheters. J. Biomater. Appl. 9 (1994) 55\u201370.","journal-title":"J. Biomater. Appl."},{"key":"BF02561611_CR46","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/S0934-8840(11)80200-8","volume":"283","author":"M. B\u00f6swald","year":"1995","unstructured":"B\u00f6swald, M., Girisch, M., Greil, J., Spies, T., Stehr, K., Krall, T., Guggenbichler, J. P.: Antimicrobial activity and biocompatibility of polyurethane and silicone catheters containing low concentrations of silver: a new perspective in prevention of polymer-associated foreign-body infections. Zentralbl. Bakteriol. 283 (1995) 187\u2013200.","journal-title":"Zentralbl. Bakteriol."},{"key":"BF02561611_CR47","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/0195-6701(95)90073-X","volume":"31","author":"B. Jansen","year":"1995","unstructured":"Jansen, B., Ruiten, D., Pulverer, G.:In-vitro activity of a catheter loaded with silver and teicoplanin to prevent bacterial and fungal colonization. J. Hosp. Infect. 31 (1995) 238\u2013241.","journal-title":"J. Hosp. Infect."},{"key":"BF02561611_CR48","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1111\/j.1464-410X.1990.tb14760.x","volume":"65","author":"H. Liedberg","year":"1990","unstructured":"Liedberg, H., Lundeberg, T.: Silver alloy coated catheters reduce catheter-associated bacteriuria. Br. J. Urol. 65 (1990) 379\u2013381.","journal-title":"Br. J. Urol."},{"key":"BF02561611_CR49","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/S0934-8840(11)80203-3","volume":"283","author":"H. Goldschmidt","year":"1995","unstructured":"Goldschmidt, H., Hahn, U., Salwender, H. J., Haas, R., Jansen, B., Wolbring, P., Rinck, M., Hunstein, W.: Prevention of catheter-related infections by silver coated catheters in oncological patients. Zentralbl. Bakteriol. 283 (1995) 215\u2013223.","journal-title":"Zentralbl. Bakteriol."},{"key":"BF02561611_CR50","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1159\/000170268","volume":"14","author":"R. Bambauer","year":"1996","unstructured":"Bambauer, R., Schiel, R., Mestres, P., Klinkmann, J., Shioshansi, P.: Scanning electron microscopic investigations of catheters for blood access. Blood Purif. 14 (1996) 249\u2013250.","journal-title":"Blood Purif."}],"container-title":["Infection"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF02561611.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF02561611\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF02561611","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,20]],"date-time":"2020-04-20T01:48:09Z","timestamp":1587347289000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF02561611"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,1]]},"references-count":50,"journal-issue":{"issue":"S1","published-print":{"date-parts":[[1999,1]]}},"alternative-id":["BF02561611"],"URL":"https:\/\/doi.org\/10.1007\/bf02561611","relation":{},"ISSN":["0300-8126","1439-0973"],"issn-type":[{"value":"0300-8126","type":"print"},{"value":"1439-0973","type":"electronic"}],"subject":[],"published":{"date-parts":[[1999,1]]}}}