{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T13:17:17Z","timestamp":1773148637839,"version":"3.50.1"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2002,12,1]],"date-time":"2002-12-01T00:00:00Z","timestamp":1038700800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Can J Anesth\/J Can Anesth"],"published-print":{"date-parts":[[2002,12]]},"DOI":"10.1007\/bf03017908","type":"journal-article","created":{"date-parts":[[2009,5,3]],"date-time":"2009-05-03T20:07:26Z","timestamp":1241381246000},"page":"1084-1087","source":"Crossref","is-referenced-by-count":22,"title":["Large cuff volumes impede posterior pharyngeal mucosal perfusion with the laryngeal tube airway","Un ballonnet de grand volume g\u00eane la perfusion de la muqueuse pharyngienne post\u00e9rieure r\u00e9alis\u00e9e avec le tube d\u2019intubation laryng\u00e9e"],"prefix":"10.1007","volume":"49","author":[{"given":"Joseph","family":"Brimacombe","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Keller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Winfried","family":"Roth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alex","family":"Loeckinger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"BF03017908_CR1","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/S0300-9572(99)00066-0","volume":"41","author":"F Agro","year":"1999","unstructured":"Agro F, Cataldo R, Alfano A, Galli B. A new prototype for airway management in an emergency: the Laryngeal Tube. Resuscitation 1999; 41: 284\u20136.","journal-title":"Resuscitation"},{"key":"BF03017908_CR2","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.1097\/00000539-200005000-00042","volume":"90","author":"V Dorges","year":"2000","unstructured":"Dorges V, Ocker H, Wenzel V, Schmucker P. The laryngeal tube: a new simple airway device. Anesth Analg 2000; 90: 1220\u20132.","journal-title":"Anesth Analg"},{"key":"BF03017908_CR3","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1046\/j.1365-2044.2000.01710.x","volume":"55","author":"T Asai","year":"2000","unstructured":"Asai T, Murao K, Shingu K. Efficacy of the laryngeal tube during intermittent positive-pressure ventilation. Anaesthesia 2000; 55: 1099\u20131102.","journal-title":"Anaesthesia"},{"key":"BF03017908_CR4","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1046\/j.1365-2346.2001.00895.x","volume":"18","author":"DM Miller","year":"2001","unstructured":"Miller DM, Youkhana I, Pearce AC. The laryngeal mask and VBM laryngeal tube compared during spontanoeus ventilation. A pilot study. Eur J Anaesthesiol 2001; 18: 593\u20138.","journal-title":"Eur J Anaesthesiol"},{"key":"BF03017908_CR5","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1093\/bja\/82.5.703","volume":"82","author":"J Brimacombe","year":"1999","unstructured":"Brimacombe J, Keller C. Laryngeal mask airway size selection in males and females: ease of insertion, oropharyngeal leak pressure, pharyngeal mucosal pressures and anatomical position. Br J Anaesth 1999; 82: 703\u20137.","journal-title":"Br J Anaesth"},{"key":"BF03017908_CR6","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1093\/bja\/82.5.708","volume":"82","author":"J Brimacombe","year":"1999","unstructured":"Brimacombe J, Keller C, Giampalmo M, Sparr HJ, Berry A. Direct measurement of mucosal pressures exerted by cuff and non-cuff portions of tracheal tubes with different cuff volumes and head and neck positions. Br J Anaesth 1999; 82: 708\u201311.","journal-title":"Br J Anaesth"},{"key":"BF03017908_CR7","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1097\/00000542-200002000-00050","volume":"92","author":"J Brimacombe","year":"2000","unstructured":"Brimacombe J, Keller C. Pharyngeal mucosa pressures (Letter). Anesthesiology 2000; 92: 620\u20131.","journal-title":"Anesthesiology"},{"key":"BF03017908_CR8","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1093\/bja\/82.2.286","volume":"82","author":"C Keller","year":"1999","unstructured":"Keller C, Brimacombe JR, Keller K, Morris R. A comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth 1999; 82: 286\u20137.","journal-title":"Br J Anaesth"},{"key":"BF03017908_CR9","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1007\/978-3-662-05747-6","volume-title":"Angewandte Statistik (German)","author":"L Sachs","year":"1992","unstructured":"Sachs L. Der kolmogoroff-smirnov-test fuer die guete der anpassung.In: Sachs L (Ed.). Angewandte Statistik (German). Berlin: Springer Verlag, 1992: 426\u201330."},{"key":"BF03017908_CR10","doi-asserted-by":"crossref","first-page":"1379","DOI":"10.1213\/00000539-199812000-00032","volume":"87","author":"J Brimacombe","year":"1998","unstructured":"Brimacombe J, Keller C. A comparison of pharyngeal mucosal pressure and airway sealing pressure with the laryngeal mask airway in anesthetized adult patients. Anesth Analg 1998; 87: 1379\u201382.","journal-title":"Anesth Analg"},{"key":"BF03017908_CR11","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1093\/bja\/82.6.922","volume":"82","author":"C Keller","year":"1999","unstructured":"Keller C, Brimacombe J. Mucosal pressures from the cuffed oropharyngeal airway vs the laryngeal mask airway. Br J Anaesth 1999; 82: 922\u20134.","journal-title":"Br J Anaesth"},{"key":"BF03017908_CR12","doi-asserted-by":"crossref","first-page":"1661","DOI":"10.1097\/00000542-199912000-00018","volume":"91","author":"J Brimacombe","year":"1999","unstructured":"Brimacombe J, Keller C, Puhringer F. Pharyngeal mucosal pressure and perfusion. A fiberoptic evaluation of the posterior pharynx in anesthetized adult patients with a modified cuffed oropharyngeal airway. Anesthesiology 1999; 91: 1661\u20135.","journal-title":"Anesthesiology"},{"key":"BF03017908_CR13","first-page":"181","volume":"89","author":"JR Brimacombe","year":"1999","unstructured":"Brimacombe JR, Keller C, Gunkel AR, Puhringer F. The influence of the tonsillar gag on efficacy of seal, anatomic position, airway patency and airway protection with the flexible laryngeal mask airway: a randomized, crossover study of fresh, adult cadavers. Anesth Analg 1999; 89: 181\u20136.","journal-title":"Anesth Analg"},{"key":"BF03017908_CR14","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1111\/j.1365-2044.1992.tb03248.x","volume":"47","author":"RG Vanner","year":"1992","unstructured":"Vanner RG, Pryle BJ. Regurgitation and oesophageal rupture with cricoid pressure: a cadaver study. Anaesthesia 1992; 47: 732\u20135.","journal-title":"Anaesthesia"},{"key":"BF03017908_CR15","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.1007\/BF03013203","volume":"46","author":"J Brimacombe","year":"1999","unstructured":"Brimacombe J, Keller C. Water flow between the upper esophagus and pharynx for the LMA and COPA in fresh cadavers. Can J Anesth 1999; 46: 1064\u20136.","journal-title":"Can J Anesth"},{"key":"BF03017908_CR16","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1016\/0002-9610(77)90008-3","volume":"133","author":"P Dobrin","year":"1977","unstructured":"Dobrin P, Canfield T. Cuffed endotracheal tubes: mucosal pressures and tracheal wall blood flow. Am J Surg1977; 133: 562\u20138.","journal-title":"Am J Surg"},{"key":"BF03017908_CR17","first-page":"201","volume":"92","author":"PJ Lennarson","year":"2000","unstructured":"Lennarson PJ, Smith D, Todd MM, et al. Segmental cervical spine motion during orotracheal intubation of the intact and injured spine with and without external stabilization. J Neurosurg 2000; 92: 201\u20136.","journal-title":"J Neurosurg"}],"container-title":["Canadian Journal of Anesthesia\/Journal canadien d'anesth\u00e9sie"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03017908.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF03017908\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03017908","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,4]],"date-time":"2021-10-04T21:16:53Z","timestamp":1633382213000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF03017908"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,12]]},"references-count":17,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2002,12]]}},"alternative-id":["BF03017908"],"URL":"https:\/\/doi.org\/10.1007\/bf03017908","relation":{},"ISSN":["0832-610X","1496-8975"],"issn-type":[{"value":"0832-610X","type":"print"},{"value":"1496-8975","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,12]]}}}