{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T02:56:11Z","timestamp":1792032971056,"version":"4.4.0"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2003,11,1]],"date-time":"2003-11-01T00:00:00Z","timestamp":1067644800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Can J Anesth\/J Can Anesth"],"published-print":{"date-parts":[[2003,11]]},"DOI":"10.1007\/bf03018734","type":"journal-article","created":{"date-parts":[[2009,5,3]],"date-time":"2009-05-03T19:58:54Z","timestamp":1241380734000},"page":"891-894","source":"Crossref","is-referenced-by-count":25,"title":["Unexpected surgical difficulties leading to hemorrhage and gas embolus during laparoscopic donor nephrectomy: a case report","Difficult\u00e9s chirurgicales inattendues conduisant \u00e0 une h\u00e9morragie et \u00e0 une embolie gazeuse pendant une n\u00e9phrectomie laparoscopique chez un donneur : une \u00e9tude de cas"],"prefix":"10.1007","volume":"50","author":[{"given":"Kenneth","family":"Martay","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Greg","family":"Dembo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Youri","family":"Vater","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Charpentier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adam","family":"Levy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramasamy","family":"Bakthavatsalam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter R.","family":"Freund","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"BF03018734_CR1","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1097\/00007890-199701270-00009","volume":"63","author":"LE Ratner","year":"1997","unstructured":"Ratner LE, Kavoussi LR, Sroka M, et al. Laparoscopic assisted live donor nephrectomy \u2014 a comparison with the open approach. Transplantation 1997; 63: 229\u201333.","journal-title":"Transplantation"},{"key":"BF03018734_CR2","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1097\/00000658-198211000-00015","volume":"196","author":"PK Harman","year":"1982","unstructured":"Harman PK, Kron IL, McLachlan HD, Freedlander AE, Nolan SP. Elevated intra-abdominal pressure and renal function. Ann Surg 1982; 196: 594\u20137.","journal-title":"Ann Surg"},{"key":"BF03018734_CR3","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1097\/00000658-199710000-00009","volume":"226","author":"JL Flowers","year":"1997","unstructured":"Flowers JL, Jacobs S, Cho E, et al. Comparison of open and laparoscopic live donor nephrectomy. Ann Surg 1997; 226: 483\u201390.","journal-title":"Ann Surg"},{"key":"BF03018734_CR4","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1097\/00007890-199908150-00019","volume":"68","author":"L Knoepp","year":"1999","unstructured":"Knoepp L, Smith M, Huey J, Mancino A, Barber H. Complication after laparoscopic donor nephrectomy. A case report and review. Transplantation 1999; 68: 449\u201351.","journal-title":"Transplantation"},{"key":"BF03018734_CR5","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1136\/pmj.78.917.153","volume":"78","author":"JR Waller","year":"2002","unstructured":"Waller JR, Hiley AL, Mullin EJ, Veitch PS, Nicholson ML. Living kidney donation: a comparison of laparoscopic and conventional open operations. Postgrad Med J 2002; 78: 153\u20137.","journal-title":"Postgrad Med J"},{"key":"BF03018734_CR6","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1007\/BF03015425","volume":"31","author":"D Shulman","year":"1984","unstructured":"Shulman D, Aronson HB. Capnography in the early diagnosis of carbon dioxide embolism during laparoscopy. Can Anaesth Soc J 1984; 31: 455\u20139.","journal-title":"Can Anaesth Soc J"},{"key":"BF03018734_CR7","first-page":"87","volume":"74","author":"R McKenzie","year":"1971","unstructured":"McKenzie R. Laparoscopy. N Z Med J 1971; 74: 87\u201391.","journal-title":"N Z Med J"},{"key":"BF03018734_CR8","first-page":"119","volume":"82","author":"M Derouin","year":"1996","unstructured":"Derouin M, Couture P, Boudreault D, Girard D, Gravel D. Detection of gas embolism by transesophageal echocardiography during laparoscopic cholecystectomy. Anesth Analg 1996; 82: 119\u201324.","journal-title":"Anesth Analg"},{"key":"BF03018734_CR9","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1213\/00000539-199903000-00006","volume":"88","author":"BG Fahy","year":"1999","unstructured":"Fahy BG, Hasnain JU, Flowers JL, Plotkin JS, Odonkor P, Ferguson MK. Transesophageal echocardiographic detection of gas embolism and cardiac valvular dysfunction during laparoscopic nephrectomy. Anesth Analg 1999; 88: 500\u20134.","journal-title":"Anesth Analg"},{"key":"BF03018734_CR10","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1093\/bja\/72.2.243","volume":"72","author":"DH Beck","year":"1994","unstructured":"Beck DH, McQuillan PJ. Fatal carbon dioxide embolism and severe haemorrhage during laparoscopic salpingectomy. Br J Anaesth 1994; 72: 243\u20135.","journal-title":"Br J Anaesth"},{"key":"BF03018734_CR11","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1093\/bja\/76.3.428","volume":"76","author":"JB Nyarwaya","year":"1996","unstructured":"Nyarwaya JB, Pierre S, Mazoit JX, et al. Effects of carbon dioxide embolism with nitrous oxide in the inspired gas in piglets. Br J Anaesth 1996; 76: 428\u201334.","journal-title":"Br J Anaesth"},{"key":"BF03018734_CR12","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/0002-8703(93)90092-N","volume":"125","author":"LL Tee","year":"1993","unstructured":"Tee LL, Williams GP, Gaither NS, Zurcher RP. Diagnosis of acute intraoperative pulmonary thromboembolism by transesophageal echocardiography. Am Heart J 1993; 125:262\u20133.","journal-title":"Am Heart J"},{"key":"BF03018734_CR13","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1097\/00000542-199408000-00030","volume":"81","author":"WC Wilson","year":"1994","unstructured":"Wilson WC, Frankville DD, Maxwell W, Carpenter T, Hastings RH. Massive intraoperative pulmonary embolus diagnosed by transesophageal echocardiography. Anesthesiology 1994; 81: 504\u20138.","journal-title":"Anesthesiology"},{"key":"BF03018734_CR14","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1097\/00000542-197610000-00018","volume":"45","author":"BA Ishak","year":"1976","unstructured":"Ishak BA, Seleny FL, Noah ZL. Venous air embolism, a possible cause of acute pulmonary edema. Anesthesiology 1976; 45: 453\u20135.","journal-title":"Anesthesiology"},{"key":"BF03018734_CR15","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1016\/S0363-5023(97)80071-8","volume":"22A","author":"RJ Cole","year":"1997","unstructured":"Cole RJ, Bindra RR, Evanoff BA, Gilula LA, Yamaguchi K, Gelberman RH. Radiographic evaluation of osseous displacement following intra-articular fractures of the distal radius: reliablility of plain radiography versus computed tomography. J Hand Surg 1997; 22A: 792\u2013800.","journal-title":"J Hand Surg"},{"key":"BF03018734_CR16","doi-asserted-by":"crossref","first-page":"1179","DOI":"10.2214\/ajr.146.6.1179","volume":"146","author":"MA Amendola","year":"1986","unstructured":"Amendola MA, Glazer GM, Grossman HB, Aisen AM, Francis IR. Staging of bladder carcinoma: MRI-CT-surgical correlation. AJR Am J Roentgenol 1986; 146: 1179\u201383.","journal-title":"AJR Am J Roentgenol"},{"key":"BF03018734_CR17","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1016\/0730-725X(90)90134-N","volume":"8","author":"DM Reker","year":"1990","unstructured":"Reker DM, Fletcher JW, Tantana S, et al. Observer reliability in CT and MRI of the abdomen\/pelvis. Magn Reson Imaging 1990; 8: 577\u201382.","journal-title":"Magn Reson Imaging"}],"container-title":["Canadian Journal of Anesthesia\/Journal canadien d'anesth\u00e9sie"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03018734.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF03018734\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03018734","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,21]],"date-time":"2019-05-21T23:09:25Z","timestamp":1558480165000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF03018734"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,11]]},"references-count":17,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2003,11]]}},"alternative-id":["BF03018734"],"URL":"https:\/\/doi.org\/10.1007\/bf03018734","relation":{},"ISSN":["0832-610X","1496-8975"],"issn-type":[{"value":"0832-610X","type":"print"},{"value":"1496-8975","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,11]]}}}