{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T09:22:48Z","timestamp":1759483368237},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2003,5,1]],"date-time":"2003-05-01T00:00:00Z","timestamp":1051747200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Can J Anesth\/J Can Anesth"],"published-print":{"date-parts":[[2003,5]]},"DOI":"10.1007\/bf03021063","type":"journal-article","created":{"date-parts":[[2009,5,3]],"date-time":"2009-05-03T20:16:39Z","timestamp":1241381799000},"page":"495-500","source":"Crossref","is-referenced-by-count":5,"title":["The PAxpress\u2122 is an effective ventilatory device but has an 18% failure rate for flexible lightwandguided tracheal intubation in anesthetized paralyzed patients","Le PAxpress\u2122 est un appareil de ventilation efficace, mais pr\u00e9sente un taux d\u2019\u00e9chec de 18 % pour l\u2019intubation trach\u00e9ale sous guidage lumineux flexible chez les patients anesth\u00e9si\u00e9s paralys\u00e9s"],"prefix":"10.1007","volume":"50","author":[{"given":"Vasilios","family":"Dimitriou","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gregory S.","family":"Voyagis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christos","family":"Iatrou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph","family":"Brimacombe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"BF03021063_CR1","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1080\/10903120090941452","volume":"4","author":"HV Genzwuerker","year":"2000","unstructured":"Genzwuerker HV, Hilker T, Hohner E, Kuhnert-Frey B. The laryngeal tube: a new adjunct for airway management. Prehosp Emerg Care 2000; 4: 168\u201372.","journal-title":"Prehosp Emerg Care"},{"key":"BF03021063_CR2","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1046\/j.1365-2044.2000.01479-11.x","volume":"55","author":"R Johnson","year":"2000","unstructured":"Johnson R, Bailie R. Airway management device (AMD\u2122) for airway control in percutaneous dilatational tracheostomy (Letter). Anaesthesia 2000; 55: 596\u20137.","journal-title":"Anaesthesia"},{"key":"BF03021063_CR3","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1093\/bja\/82.2.286","volume":"82","author":"C Keller","year":"1999","unstructured":"Keller C, Brimacombe JR, Keller K, Morris R. A comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth 1999; 82: 286\u20137.","journal-title":"Br J Anaesth"},{"key":"BF03021063_CR4","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1093\/bja\/88.1.127","volume":"88","author":"J Brimacombe","year":"2002","unstructured":"Brimacombe J, Keller C, Kurian S, Myles J. Reliability of epigastric auscultation to detect gastric insufflation. Br J Anaesth 2002; 88: 127\u20139.","journal-title":"Br J Anaesth"},{"key":"BF03021063_CR5","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1213\/00000539-199907000-00052","volume":"89","author":"V Dimitriou","year":"1999","unstructured":"Dimitriou V, Voyagis GS. Use of a prototype flexible lighted catheter for guided tracheal intubation through the intubating laryngeal mask (Letter). Anesth Analg 1999; 89: 257\u20138.","journal-title":"Anesth Analg"},{"key":"BF03021063_CR6","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1097\/00000542-199211000-00003","volume":"77","author":"I Smith","year":"1992","unstructured":"Smith I, White PF. Use of the laryngeal mask airway as an alternative to a face mask during outpatient arthroscopy. Anesthesiology 1992; 77: 850\u20135.","journal-title":"Anesthesiology"},{"key":"BF03021063_CR7","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1007\/BF03016840","volume":"48","author":"S Kihara","year":"2001","unstructured":"Kihara S, Yaguchi Y, Brimacombe J, Watanabe S, Taguchi N. Routine use of the intubating laryngeal mask airway results in increased upper airway morbidity. Can J Anesth 2001; 48: 604\u20138.","journal-title":"Can J Anesth"},{"key":"BF03021063_CR8","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1097\/00000542-200007000-00019","volume":"93","author":"J Brimacombe","year":"2000","unstructured":"Brimacombe J, Keller C. The ProSeal laryngeal mask airway. A randomized, crossover study with the standard laryngeal mask airway in paralyzed, anesthetized patients. Anesthesiology 2000; 93: 104\u20139.","journal-title":"Anesthesiology"},{"key":"BF03021063_CR9","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1046\/j.1365-2044.2000.01710.x","volume":"55","author":"T Asai","year":"2000","unstructured":"Asai T, Murao K, Shingu K. Efficacy of the laryngeal tube during intermittent positive-pressure ventilation. Anaesthesia 2000; 55: 1099\u2013102.","journal-title":"Anaesthesia"},{"key":"BF03021063_CR10","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1097\/00000542-199804000-00017","volume":"88","author":"RS Greenberg","year":"1998","unstructured":"Greenberg RS, Brimacombe J, Berry A, Gouze V, Piantadosi S, Dake EM. A randomized controlled trial comparing the cuffed oropharyngeal airway and the laryngeal mask airway in spontaneously breathing anesthetized adults. Anesthesiology 1998; 88: 970\u20137.","journal-title":"Anesthesiology"},{"key":"BF03021063_CR11","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1213\/00000539-199807000-00031","volume":"87","author":"JR Brimacombe","year":"1998","unstructured":"Brimacombe JR, Brimacombe JC, Berry AM, et al. A comparison of the laryngeal mask airway and cuffed oropharyngeal airway in anesthetized adult patients. Anesth Analg 1998; 87: 147\u201352.","journal-title":"Anesth Analg"},{"key":"BF03021063_CR12","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1097\/00000542-199905000-00014","volume":"90","author":"JM Vlymen van","year":"1999","unstructured":"van Vlymen JM, Fu W, White PF, Klein KW, Griffin JD. Use of the cuffed oropharyngeal airway as an alternative to the laryngeal mask airway with positive-pressure ventilation. Anesthesiology 1999; 90: 1306\u201310.","journal-title":"Anesthesiology"},{"key":"BF03021063_CR13","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1093\/bja\/85.2.262","volume":"85","author":"C Keller","year":"2000","unstructured":"Keller C, Brimacombe J. Mucosal pressure and oropharyngeal leak pressure with the ProSeal versus laryngeal mask airway in anaesthetized patients. Br J Anaesth 2000; 85: 262\u20136.","journal-title":"Br J Anaesth"},{"key":"BF03021063_CR14","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1093\/bja\/82.5.703","volume":"82","author":"J Brimacombe","year":"1999","unstructured":"Brimacombe J, Keller C. Laryngeal mask airway size selection in males and females: ease of insertion, oropharyngeal leak pressure, pharyngeal mucosal pressures and anatomical position. Br J Anaesth 1999; 82: 703\u20137.","journal-title":"Br J Anaesth"},{"key":"BF03021063_CR15","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1007\/BF03013204","volume":"46","author":"C Keller","year":"1999","unstructured":"Keller C, Brimacombe J. The intubating laryngeal mask airway in fresh cadavers vs paralysed anesthetised patients. Can J Anesth 1999; 46: 1067\u20139.","journal-title":"Can J Anesth"},{"key":"BF03021063_CR16","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1097\/00000542-199904000-00012","volume":"90","author":"C Keller","year":"1999","unstructured":"Keller C, Brimacombe J. Pharyngeal mucosal pressures, airway sealing pressures and fiberoptic position with the intubating versus the standard laryngeal mask airway. Anesthesiology 1999; 90: 1001\u20136.","journal-title":"Anesthesiology"},{"key":"BF03021063_CR17","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1097\/00000539-200111000-00064","volume":"93","author":"J Brimacombe","year":"2001","unstructured":"Brimacombe J, Keller C, Boehler M, Puhringer F. Positive pressure ventilation with the ProSeal versus classic laryngeal mask airway: a randomized, crossover study of healthy female patients. Anesth Analg 2001; 93: 1351\u20133.","journal-title":"Anesth Analg"},{"key":"BF03021063_CR18","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.1097\/00000539-200005000-00042","volume":"90","author":"V Doerges","year":"2000","unstructured":"Doerges V, Ocker H, Wenzel V, Schmucker P. The laryngeal tube: a new simple airway device. Anesth Analg 2000; 90: 1220\u20132.","journal-title":"Anesth Analg"},{"key":"BF03021063_CR19","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1097\/00000542-199403000-00011","volume":"80","author":"JH Devitt","year":"1994","unstructured":"Devitt JH, Wenstone R, Noel AG, O\u2019Donnell MP. The laryngeal mask airway and positive-pressure ventilation. Anesthesiology 1994; 80: 550\u20135.","journal-title":"Anesthesiology"},{"key":"BF03021063_CR20","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1213\/00000539-199705000-00013","volume":"84","author":"N Weiler","year":"1997","unstructured":"Weiler N, Latorre F, Eberle B, Goedecke R, Heinrichs W. Respiratory mechanics, gastric insufflation pressure, and air leakage of the laryngeal mask airway. Anesth Analg 1997; 84: 1025\u20138.","journal-title":"Anesth Analg"},{"key":"BF03021063_CR21","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.1007\/BF03013203","volume":"46","author":"J Hrimacombe","year":"1999","unstructured":"Hrimacombe J, Keller C. Water flow between the upper esophagus and pharynx for the LMA and COPA in fresh cadavers. Can J Anesth 1999; 46: 1064\u20136.","journal-title":"Can J Anesth"},{"key":"BF03021063_CR22","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1097\/00000542-199601000-00019","volume":"84","author":"C Reali-Forster","year":"1996","unstructured":"Reali-Forster C, Kolobow T, Giacomini M, Hayashi T, Horiba K, Ferraris VJ. New ultrathin-walled endotracheal tube with a novel laryngeal seal design. Longterm evaluation in sheep. Anesthesiology 1996; 84: 162\u201372.","journal-title":"Anesthesiology"},{"key":"BF03021063_CR23","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1034\/j.1399-6576.2000.440818.x","volume":"44","author":"V Dimitriou","year":"2000","unstructured":"Dimitriou V, Voyagis GS. Light-guided intubation via the intubating laryngeal mask using a prototype illuminated flexible catheter: clinical experience in 400 patients. Acta Anaesthesiol Scand 2000; 44: 1002\u20136.","journal-title":"Acta Anaesthesiol Scand"},{"key":"BF03021063_CR24","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1097\/00000542-199705000-00006","volume":"86","author":"P Krafft","year":"1997","unstructured":"Krafft P, Roggla M, Fridrich P, Locker GJ, Frass M, Benumof JL. Bronchoscopy via a redesigned Combitube in the esophageal position. A clinical evaluation. Anesthesiology 1997; 86: 1041\u20135.","journal-title":"Anesthesiology"},{"key":"BF03021063_CR25","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1213\/00000539-199901000-00036","volume":"88","author":"LA Gaitini","year":"1999","unstructured":"Gaitini LA, Vaida SJ, Somri M, Fradis M, Ben-David B. Fiberoptic-guided airway exchange of the esophageal-tracheal Combitube\u00ae in spontaneously breathing versus mechanically ventilated patients. Anesth Analg 1999; 88: 193\u20136.","journal-title":"Anesth Analg"},{"key":"BF03021063_CR26","doi-asserted-by":"crossref","first-page":"1661","DOI":"10.1097\/00000542-199912000-00018","volume":"91","author":"J Brimacombe","year":"1999","unstructured":"Brimacombe J, Keller C, Puhringer F. Pharyngeal mucosal pressure and perfusion. A fiberoptic evaluation of the posterior pharynx in anesthetized adult patients with a modified cuffed oropharyngeal airway. Anesthesiology 1999; 91: 1661\u20135.","journal-title":"Anesthesiology"},{"key":"BF03021063_CR27","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1046\/j.1365-2044.2000.01324.x","volume":"55","author":"S Kihara","year":"2000","unstructured":"Kihara S, Watanabe S, Taguchi N, Suga A, Brimacombe JR. A comparison of blind and lightwand-guided tracheal intubation through the intubating laryngeal mask. Anaesthesia 2000; 55: 427\u201331.","journal-title":"Anaesthesia"}],"container-title":["Canadian Journal of Anesthesia\/Journal canadien d'anesth\u00e9sie"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03021063.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF03021063\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03021063","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,4]],"date-time":"2021-10-04T21:18:06Z","timestamp":1633382286000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF03021063"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,5]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2003,5]]}},"alternative-id":["BF03021063"],"URL":"https:\/\/doi.org\/10.1007\/bf03021063","relation":{},"ISSN":["0832-610X","1496-8975"],"issn-type":[{"value":"0832-610X","type":"print"},{"value":"1496-8975","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,5]]}}}