{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T16:24:16Z","timestamp":1778084656269,"version":"3.51.4"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2001,5,1]],"date-time":"2001-05-01T00:00:00Z","timestamp":988675200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Can J Anesth\/J Can Anesth"],"published-print":{"date-parts":[[2001,5]]},"DOI":"10.1007\/bf03028304","type":"journal-article","created":{"date-parts":[[2009,5,3]],"date-time":"2009-05-03T16:41:50Z","timestamp":1241368910000},"page":"435-438","source":"Crossref","is-referenced-by-count":9,"title":["Production of compound A under low-flow anesthesia is affected by type of anesthetic machine"],"prefix":"10.1007","volume":"48","author":[{"given":"Michiaki","family":"Yamakage","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akira","family":"Kimura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiangdong","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoki","family":"Tsujiguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuhiro","family":"Kamada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akiyoshi","family":"Namiki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"BF03028304_CR1","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1213\/00000539-197511000-00021","volume":"54","author":"RF Wallin","year":"1975","unstructured":"Wallin RF, Regan BM, Napoli MD, Stern IJ. Sevoflurane: a new inhalational anesthetic agent. Anesth Analg 1975; 54: 758\u201365.","journal-title":"Anesth Analg"},{"key":"BF03028304_CR2","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1097\/00000542-199403000-00013","volume":"80","author":"CT Gonsowski","year":"1994","unstructured":"Gonsowski CT, Laster MJ, Eger IIEI, Ferrell LD, Kerschmann RL. Toxicity of compound A in rats. Effect of increasing duration of administration. Anesthesiology 1994; 80: 566\u201373.","journal-title":"Anesthesiology"},{"key":"BF03028304_CR3","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1097\/00000542-199403000-00012","volume":"80","author":"CT Gonsowski","year":"1994","unstructured":"Gonsowski CT, Laster MJ, Eger IIEI, Ferrell LD, Kerschmann RL. Toxicity of compound A in rats. Effect of a 3-hour administration. Anesthesiology 1994; 80: 556\u201365.","journal-title":"Anesthesiology"},{"key":"BF03028304_CR4","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1097\/00000542-199706000-00003","volume":"86","author":"H Bito","year":"1997","unstructured":"Bito H, Ikeuchi Y, Ikeda K Effects of low-flow sevoflurane anesthesia on renal function. Comparison with high-flow sevoflurane anesthesia and low-flow isoflurane anesthesia. Anesthesiology 1997; 86: 1231\u20137.","journal-title":"Anesthesiology"},{"key":"BF03028304_CR5","doi-asserted-by":"crossref","first-page":"1238","DOI":"10.1097\/00000542-199706000-00004","volume":"86","author":"ED Kharasch","year":"1997","unstructured":"Kharasch ED, Frink EJ Jr, Zager R, Bowdle TA, Artru A, Nogami WM. Assessment of low-flow sevoflurane and isoflurane effects on renal function using sensitive markers of tubular toxicity. Anesthesiology 1997; 86: 1238\u201353.","journal-title":"Anesthesiology"},{"key":"BF03028304_CR6","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1097\/00000542-199706000-00001","volume":"86","author":"RJ Mazze","year":"1997","unstructured":"Mazze RJ, Jamison RL. Low-flow (11\/min) sevoflurane. Is it safe? (Editorial). Anesthesiology 1997; 86: 1225\u20137.","journal-title":"Anesthesiology"},{"key":"BF03028304_CR7","first-page":"564","volume":"81","author":"ZX Fang","year":"1995","unstructured":"Fang ZX, Eger IIEI. Factors affecting the concentration of compound A resulting from the degradation of sevoflurane by soda lime and Baralyme\u00ae in a standard anesthetic circuit. Anesth Analg 1995; 81: 564\u20138.","journal-title":"Anesth Analg"},{"key":"BF03028304_CR8","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1097\/00000542-199408000-00011","volume":"81","author":"H Bito","year":"1994","unstructured":"Bito H, Ikeda K. Long-duration, low-flow sevoflurane anesthesia using two carbon dioxide absorbents. Quantification of degradation products in the circuit. Anesthesiology 1994; 81: 340\u20135.","journal-title":"Anesthesiology"},{"key":"BF03028304_CR9","first-page":"775","volume":"82","author":"ZX Fang","year":"1996","unstructured":"Fang ZX, Kandel L, Laster MJ, Ionescu P, Eger IIEI. Factors affecting production of compound A from the interaction of sevoflurane with Baralyme\u00ae and soda lime. Anesth Analg 1996; 82: 775\u201381.","journal-title":"Anesth Analg"},{"key":"BF03028304_CR10","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1093\/bja\/74.6.667","volume":"74","author":"H Bito","year":"1995","unstructured":"Bito H, Ikeda K. Effect of total flow rate on the concentration of degradation products generated by reaction between sevoflurane and soda lime. Br J Anaesth 1995; 74: 667\u20139.","journal-title":"Br J Anaesth"},{"key":"BF03028304_CR11","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1097\/00000542-199407000-00030","volume":"81","author":"JA Ruzicka","year":"1994","unstructured":"Ruzicka JA, Hidalgo JC, Tinker JH, Baxter MT Inhibition of volatile sevoflurane degradation product formation in an anesthesia circuit by a reduction in soda lime temperature. Anesthesiology 1994; 81: 238\u201344.","journal-title":"Anesthesiology"},{"key":"BF03028304_CR12","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1007\/BF03015449","volume":"44","author":"AD Baxter","year":"1997","unstructured":"Baxter AD. Low and minimal flow inhalational anaesthesia. Can J Anaesth 1997; 44: 643\u201353.","journal-title":"Can J Anaesth"},{"key":"BF03028304_CR13","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1213\/00000539-199909000-00046","volume":"89","author":"MA Neumann","year":"1999","unstructured":"Neumann MA, Laster MJ, Weiskopf RB, et al. The elimination of sodium and potassium hydroxides from desiccated soda lime diminishes degradation of desflurane to carbon monoxide and sevoflurane to compound A but does not compromise carbon dioxide absorption. Anesth Analg 1999; 89: 768\u201373.","journal-title":"Anesth Analg"},{"key":"BF03028304_CR14","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1097\/00000542-199911000-00026","volume":"91","author":"JM Murray","year":"1999","unstructured":"Murray JM, Renfrew CW, Bedi A, et al. Amsorb. A new carbon dioxide absorbent for use in anesthetic breathing systems. Anesthesiology 1999; 91: 1342\u20138.","journal-title":"Anesthesiology"},{"key":"BF03028304_CR15","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1213\/00000539-200007000-00041","volume":"91","author":"M Yamakage","year":"2000","unstructured":"Yamakage M, Yamada S, Chen X, Iwasaki S, Tsujiguchi N, Namiki A. Carbon dioxide absorbents containing potassium hydroxide produce much larger concentrations of compound A from sevoflurane in clinical practice. Anesth Analg 2000; 91: 220\u20134.","journal-title":"Anesth Analg"},{"key":"BF03028304_CR16","first-page":"434","volume":"91","author":"H Higuchi","year":"2000","unstructured":"Higuchi H, Adachi Y, Arimura S, Kanno M, Satoh T. Compound A concentrations during low-flow sevoflurane anesthesia correlate directly with the concentrations of monovalent bases in carbon dioxide absorbents. Anesth Analg 2000; 91: 434\u20139.","journal-title":"Anesth Analg"}],"container-title":["Canadian Journal of Anesthesia\/Journal canadien d'anesth\u00e9sie"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03028304.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF03028304\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03028304","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,24]],"date-time":"2023-05-24T20:33:05Z","timestamp":1684960385000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF03028304"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,5]]},"references-count":16,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2001,5]]}},"alternative-id":["BF03028304"],"URL":"https:\/\/doi.org\/10.1007\/bf03028304","relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.721510285.793508684","asserted-by":"object"}]},"ISSN":["0832-610X","1496-8975"],"issn-type":[{"value":"0832-610X","type":"print"},{"value":"1496-8975","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,5]]}}}