{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T23:25:41Z","timestamp":1769124341321,"version":"3.49.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[1999,7,1]],"date-time":"1999-07-01T00:00:00Z","timestamp":930787200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Med Klin"],"published-print":{"date-parts":[[1999,7]]},"DOI":"10.1007\/bf03044900","type":"journal-article","created":{"date-parts":[[2009,6,8]],"date-time":"2009-06-08T23:44:16Z","timestamp":1244504656000},"page":"367-370","source":"Crossref","is-referenced-by-count":26,"title":["Detektion eines offenen Foramen ovale","Transesophageal echocardiography and contrast-transcranial Doppler sonography yield a higher rate for the detection of patent foramen ovale than one method alone"],"prefix":"10.1007","volume":"94","author":[{"given":"Josef Georg","family":"Heckmann","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wolfgang","family":"Niedermeier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Magdalena","family":"Brandt-Pohlmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Max Josef","family":"Hilz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Hecht","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernhard","family":"Neund\u00f6rfer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"BF03044900_CR1","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1159\/000107875","volume":"5","author":"HP Adams","year":"1995","unstructured":"Adams HP, Love BB. Transesophageal echocardiography in the evaluation of young adults with ischemic stroke: promises and concerns. Cerebrovasc Dis 1995;5:323\u20137.","journal-title":"Cerebrovasc Dis"},{"key":"BF03044900_CR2","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1159\/000107851","volume":"5","author":"GP Anzola","year":"1995","unstructured":"Anzola GP, Renaldini E, Magoni M, et al. Validation of transcranial Doppler sonography in the assessment of patent foramen ovale. Cerbrovasc Dis 1995;5:194\u20138.","journal-title":"Cerbrovasc Dis"},{"key":"BF03044900_CR3","doi-asserted-by":"crossref","first-page":"1371","DOI":"10.1055\/s-2008-1047773","volume":"122","author":"F Berger","year":"1997","unstructured":"Berger F, Uhlemann F, N\u00fcrnberg JH, et al. Transkatheterverschlu\u00df des persistierenden Foramen ovale als M\u00f6glichkeit zur Vermeidung paradoxer Embolien. Dtsch Med Wochenschr 1997;122:1371\u20136.","journal-title":"Dtsch Med Wochenschr"},{"key":"BF03044900_CR4","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1007\/s004150050052","volume":"244","author":"J Bogousslavsky","year":"1997","unstructured":"Bogousslavsky J, Devuyst G, Nendaz M, et al. Prevention of stroke recurrence with presumed paradoxical embolism. J Neurol 1997;244:71\u20135.","journal-title":"J Neurol"},{"key":"BF03044900_CR5","doi-asserted-by":"crossref","first-page":"1844","DOI":"10.1161\/01.STR.27.10.1844","volume":"27","author":"M Daffertshofer","year":"1996","unstructured":"Daffertshofer M, Ries S, Schminke U, et al. High-intensity transient signals in patients with zerebral ischemia. Stroke 1996;27:1844\u20139.","journal-title":"Stroke"},{"key":"BF03044900_CR6","doi-asserted-by":"crossref","first-page":"1162","DOI":"10.1212\/WNL.47.5.1162","volume":"47","author":"G Devuyst","year":"1996","unstructured":"Devuyst G, Bougousslavsky J, Ruchat P, et al. Prognosis after stroke followed by surgical closure of patent foramen ovale: a prospective follow-up study with brain MRI and simultaneous transesophageal and transcranial Doppler ultrasound. Neurology (NY) 1996;47:1162\u20136.","journal-title":"Neurology (NY)"},{"key":"BF03044900_CR7","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1159\/000112897","volume":"38","author":"G Devuyst","year":"1997","unstructured":"Devuyst G, Despland PA, Bogousslavsky J, et al. Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. Eur Neurol 1997;38:21\u20135.","journal-title":"Eur Neurol"},{"key":"BF03044900_CR8","doi-asserted-by":"crossref","first-page":"461","DOI":"10.7326\/0003-4819-117-6-461","volume":"117","author":"M Tullio Di","year":"1992","unstructured":"Di Tullio M, Sacco RL, Gopal A, et al. Patent foramen ovale as a risk factor for cryptogenic stroke. Ann Intern Med 1992;117:461\u20135.","journal-title":"Ann Intern Med"},{"key":"BF03044900_CR9","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1161\/01.STR.24.7.1020","volume":"24","author":"M Tullio Di","year":"1993","unstructured":"Di Tullio M, Sacco RL, Venketasubramanian N, et al. Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients. Stroke 1993;24:1020\u20134.","journal-title":"Stroke"},{"key":"BF03044900_CR10","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/S0025-6196(12)60336-X","volume":"59","author":"P Hagen","year":"1984","unstructured":"Hagen P, Scholz DG, Edwards W. Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. Mayo Clin Proc 1984;59:17\u201320.","journal-title":"Mayo Clin Proc"},{"key":"BF03044900_CR11","doi-asserted-by":"crossref","first-page":"668","DOI":"10.1016\/0002-9149(92)90210-P","volume":"70","author":"D Hausmann","year":"1992","unstructured":"Hausmann D, M\u00fcgge A, Becht I, et al. Diagnosis of patent foramen ovale by transesophageal echocardiography and association with cerebral and peripheral embolic events. Am J Cardiol 1992;70:668\u201372.","journal-title":"Am J Cardiol"},{"key":"BF03044900_CR12","first-page":"458","volume":"17","author":"JH Heckmann","year":"1998","unstructured":"Heckmann JH, Hilz MJ, Brandt-Pohlmann M, et al. Aktueller Stand der Diagnostik des offenen Foramen ovale. Nervenheilkunde 1998;17:458\u201360.","journal-title":"Nervenheilkunde"},{"key":"BF03044900_CR13","doi-asserted-by":"crossref","first-page":"2376","DOI":"10.1161\/01.STR.28.12.2376","volume":"28","author":"S Homma","year":"1997","unstructured":"Homma S, Di Tullio MR, Sacco RL, et al. Surgical closure of patent foramen ovale in cryptogenic stroke patients. Stroke 1997;28:2376\u201381.","journal-title":"Stroke"},{"key":"BF03044900_CR14","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/0002-9149(94)90407-3","volume":"74","author":"FP Job","year":"1994","unstructured":"Job FP, Ringelstein EB, Grafen U, et al. Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. Am J Cardiol 1994;74:381\u20134.","journal-title":"Am J Cardiol"},{"key":"BF03044900_CR15","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1111\/j.1600-0404.1998.tb00643.x","volume":"97","author":"V Kartunnen","year":"1998","unstructured":"Kartunnen V, Ventil\u00e4 M, Hillbom M, et al. Dye dilution and oximetry for detection of patent foramen ovale. Acta Neurol Scand 1998;97:231\u20136.","journal-title":"Acta Neurol Scand"},{"key":"BF03044900_CR16","doi-asserted-by":"crossref","first-page":"1603","DOI":"10.1212\/WNL.44.9.1603","volume":"44","author":"C Kl\u00f6tzsch","year":"1994","unstructured":"Kl\u00f6tzsch C, Janssen G, Berlit P. Transesophageal echocardiography and contrast-TCD in the detection of patent foramen ovale: experience with 111 patients. Neurology (NY) 1994;44:1603\u20136.","journal-title":"Neurology (NY)"},{"key":"BF03044900_CR17","doi-asserted-by":"crossref","first-page":"1148","DOI":"10.1056\/NEJM198805053181802","volume":"318","author":"P Lechat","year":"1988","unstructured":"Lechat P, Mas JL, Lascault G, et al. Prevalence of patent foramen ovale in patients with stroke. N Engl J Med 1988;318:1148\u201352.","journal-title":"N Engl J Med"},{"key":"BF03044900_CR18","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1159\/000117442","volume":"37","author":"M Nendaz","year":"1997","unstructured":"Nendaz M, Sarasin FP, Bogousslavsky J. How to prevent stroke recurrence in patients with patent foramen ovale: anticoagulants, antiaggregants, foramen closure, or nothing? Eur Neurol 1997;37:199\u2013204.","journal-title":"Eur Neurol"},{"key":"BF03044900_CR19","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/0735-1097(91)90705-E","volume":"1","author":"AC Pearson","year":"1991","unstructured":"Pearson AC, Labovitz AJ, Tatineni S, et al. Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology. J Am Coll Cardiol 1991;1:66\u201372.","journal-title":"J Am Coll Cardiol"},{"key":"BF03044900_CR20","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1159\/000117443","volume":"37","author":"RL Sacco","year":"1997","unstructured":"Sacco RL, Di Tullio M, Homma S. Treatment of patent foramen ovale and stroke: to close or not to close, that is not yet the question. Eur Neurol 1997;37:205\u20136.","journal-title":"Eur Neurol"},{"key":"BF03044900_CR21","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1159\/000107838","volume":"5","author":"U Schminke","year":"1995","unstructured":"Schminke U, Ries S, Daffertshofer M, et al. Patent foramen ovale: a potential source of cerebral embolism? Cerebrovasc Dis 1995;5:133\u20138.","journal-title":"Cerebrovasc Dis"},{"key":"BF03044900_CR22","doi-asserted-by":"crossref","first-page":"1667","DOI":"10.1055\/s-2008-1055526","volume":"120","author":"U Sliwka","year":"1995","unstructured":"Sliwka U, Diehl RR, Noth J, Bedeutung sogenannter \u201eHigh-Intensity Transient Signals\u201d (HITS) w\u00e4brend der transkraniellen Dopplersonographie. Dtsch Med Wochenschr 1995;120:1667\u201370.","journal-title":"Dtsch Med Wochenschr"}],"container-title":["Medizinische Klinik"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03044900.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF03044900\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03044900","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,21]],"date-time":"2019-05-21T19:49:36Z","timestamp":1558468176000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF03044900"}},"subtitle":["Trans\u00f6sophageale Echokardiographie und transkranielle Dopplersonographie mit Ultraschallkontrastmittel sind \u201eerg\u00e4nzende, nicht konkurrierende Methoden\u201d"],"short-title":[],"issued":{"date-parts":[[1999,7]]},"references-count":22,"journal-issue":{"issue":"7","published-print":{"date-parts":[[1999,7]]}},"alternative-id":["BF03044900"],"URL":"https:\/\/doi.org\/10.1007\/bf03044900","relation":{},"ISSN":["0723-5003","1615-6722"],"issn-type":[{"value":"0723-5003","type":"print"},{"value":"1615-6722","type":"electronic"}],"subject":[],"published":{"date-parts":[[1999,7]]}}}