{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,16]],"date-time":"2023-09-16T08:08:08Z","timestamp":1694851688840},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[1996,12,1]],"date-time":"1996-12-01T00:00:00Z","timestamp":849398400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ann Nucl Med"],"published-print":{"date-parts":[[1996,12]]},"DOI":"10.1007\/bf03164802","type":"journal-article","created":{"date-parts":[[2009,9,26]],"date-time":"2009-09-26T09:43:35Z","timestamp":1253958215000},"page":"409-417","source":"Crossref","is-referenced-by-count":9,"title":["Abdominal SPECT\/MRI fusion applied to the study of splenic and hepatic uptake of radiolabeled thrombocytes and colloids"],"prefix":"10.1007","volume":"10","author":[{"given":"Hanna K.","family":"Pohjonen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sauli E.","family":"Savolainen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P\u00e4ivi H.","family":"Nikkinen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Veli-Pekka O.","family":"Poutanen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E. Tapani","family":"Korppi-Tommola","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B. Kristian","family":"Liewendahl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"BF03164802_CR1","first-page":"731","volume":"4","author":"C Bohm","year":"1983","unstructured":"Bohm C, Creitz T, Kingsley D, Berggren BM, Olsson L. Adjustable computerized stereotaxic brain atlas for transmission and emission tomography.Am J Neuroradiol 4: 731\u2013733, 1983.","journal-title":"Am J Neuroradiol"},{"key":"BF03164802_CR2","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1007\/978-3-642-84211-5_15","volume-title":"NATO ASI Series, 3D imaging in medicine","author":"DJ Hawkes","year":"1990","unstructured":"Hawkes DJ, Hill DLG, Lehmann ED, Robinson GP, Maisey MN, Colchester ACF. Preliminary work on the interpretation of SPECT images with the aid of registered MR images and an MR derived 3D neuro-anatomical atlas.In NATO ASI Series, 3D imaging in medicine, KH Hohne, et al. (eds.), Berlin, Heidelberg, New York, Springer-Verlag, pp. 241\u2013251, 1990."},{"key":"BF03164802_CR3","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1097\/00004728-198102000-00027","volume":"5","author":"M Bergstr\u00f6m","year":"1981","unstructured":"Bergstr\u00f6m M, Bo\u00ebthius J, Eriksson L, Greitz T, Ribbe T, Wid\u00e9n L. Head fixation device for reproducible position alignment in transmission CT and positron emission tomography.J Comp Ass Tomog 5: 136\u2013141, 1981.","journal-title":"J Comp Ass Tomog"},{"key":"BF03164802_CR4","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1097\/00004728-198501000-00025","volume":"9","author":"FT Fox","year":"1985","unstructured":"Fox FT, Perlmutter JS, Raichle ME. A stereotactic method of anatomical localization for positron emission tomography.J Comp Ass Tomog 9: 141\u2013153, 1985.","journal-title":"J Comp Ass Tomog"},{"key":"BF03164802_CR5","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1097\/00004728-198208000-00043","volume":"6","author":"JC Mazziotta","year":"1982","unstructured":"Mazziotta JC, Phelps ME, Meadors AK, Ricci A, Winter J, Bentson JR. Anatomical localization schemes for use in positron computed tomography using a specially designed headholder.J Comp Ass Tomog 6: 848\u2013853, 1982.","journal-title":"J Comp Ass Tomog"},{"key":"BF03164802_CR6","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/00004728-198803000-00038","volume":"12","author":"S Miura","year":"1988","unstructured":"Miura S, Kanno I, Iida H, et al. Anatomical adjustments in brain positron emission tomography using CT images.J Comp Ass Tomog 12: 363\u2013367, 1988.","journal-title":"J Comp Ass Tomog"},{"key":"BF03164802_CR7","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1097\/00004728-198901000-00004","volume":"13","author":"CA Pelizzari","year":"1989","unstructured":"Pelizzari CA, Chen GTY, Speibring DR, Weichselbaum RR, Chen CT. Accurate three-dimensional registration of CT, PET, and\/or MR images of the brain.J Comp Ass Tomog 13: 20\u201326, 1989.","journal-title":"J Comp Ass Tomog"},{"key":"BF03164802_CR8","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1007\/978-3-642-52311-3_118","volume-title":"Proceedings of CAR\u201989 Computer Assisted Radiology","author":"C Schiers","year":"1989","unstructured":"Schiers C, Tiede U, H\u00f6hne KH. Interactive 3D registration of image volumes from different sources.In Proceedings of CAR\u201989 Computer Assisted Radiology, Lemke HU, Rhodes ML, Jaffe CC, Felix R (eds.), Berlin, Springer-Verlag, pp. 666\u2013670, 1989."},{"key":"BF03164802_CR9","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1259\/0007-1285-64-767-1030","volume":"64","author":"DLG Hill","year":"1991","unstructured":"Hill DLG, Hawkes DJ, Crossman JE, et al. Registration of MR and CT images for skull base surgery using point-like anatomical features.Brit J Radiol 64: 1030\u20131035, 1991.","journal-title":"Brit J Radiol"},{"key":"BF03164802_CR10","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1109\/38.180113","volume":"13","author":"PG Spetsieris","year":"1993","unstructured":"Spetsieris PG, Dhawan V, Takikawa S, Margouleff D, Eidelberg D. Imaging cerebral function.IEEE Comput Graph Appl 13: 15\u201326, 1993.","journal-title":"IEEE Comput Graph Appl"},{"key":"BF03164802_CR11","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1007\/BF00604791","volume":"38","author":"H Pohjonen","year":"1996","unstructured":"Pohjonen H, Nikkinen P, Sipil\u00e4 O, et al. Registration and display of brain SPECT and MRI using external markers.Neuroradiology 38: 108\u2013114, 1996.","journal-title":"Neuroradiology"},{"key":"BF03164802_CR12","first-page":"1595","volume":"34","author":"G Sgouros","year":"1993","unstructured":"Sgouros G, Chiu S, Pentlow KS, et al. Three-dimensional dosimetry for radioimmunotherapy treatment planning.J Nucl Med 34: 1595\u20131601, 1993.","journal-title":"J Nucl Med"},{"key":"BF03164802_CR13","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1148\/radiology.172.3.2788895","volume":"172","author":"E Kramer","year":"1989","unstructured":"Kramer E, Noz ME, Sanger JJ, Megibow AJ, Maguire GQ. CT-SPECT fusion to correlate radiolabeled monoclonal antibody uptake with abdominal CT findings.Radiology 172: 861\u2013865, 1989.","journal-title":"Radiology"},{"key":"BF03164802_CR14","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1148\/radiology.181.2.1924790","volume":"181","author":"BA Birnbaum","year":"1991","unstructured":"Birnbaum BA, Noz ME, Chapnick J, et al. Hepatic hemangiomas: diagnosis with fusion of MR, CT, and Tc-99m-labeled red blood cell SPECT images.Radiology 181: 469\u2013474, 1991.","journal-title":"Radiology"},{"key":"BF03164802_CR15","first-page":"1714","volume":"35","author":"KF Koral","year":"1994","unstructured":"Koral KF, Zasadny KR, Kessler ML, et al. CT-SPECT fusion plus conjugate views for determining dosimetry in iodine-131-monoclonal antibody therapy of lymphoma patients.J Nucl Med 35: 1714\u20131720, 1994.","journal-title":"J Nucl Med"},{"key":"BF03164802_CR16","first-page":"1407","volume":"35","author":"JG Tjuvajev","year":"1994","unstructured":"Tjuvajev JG, Homer AM, Daghighian F, et al. Imaging of brain tumor proliferative activity with iodine-131-iododeoxyuridine.J Nucl Med 35: 1407\u20131417, 1994.","journal-title":"J Nucl Med"},{"key":"BF03164802_CR17","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1118\/1.597047","volume":"20","author":"S-E Strand","year":"1993","unstructured":"Strand S-E, Zanzonico P, Johnson TK. Pharmacokinetic modeling.Med Phys 20: 515\u2013527, 1993.","journal-title":"Med Phys"},{"issue":"2","key":"BF03164802_CR18","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1118\/1.597051","volume":"20","author":"PK Leichner","year":"1993","unstructured":"Leichner PK, Koral KF, Jaszczak RJ, Green AJ, Chen GTY, Roeske JC. An overview of imaging techniques and physical aspects of treatment planning in radioimmunotherapy.Med Phys 20 (2): 569\u2013578, 1993.","journal-title":"Med Phys"},{"key":"BF03164802_CR19","first-page":"1546","volume":"30","author":"MT Syrj\u00e4l\u00e4","year":"1989","unstructured":"Syrj\u00e4l\u00e4 MT, Savolainen S, Nieminen U, Gripenberg J, Liewendahl K, Ikkala E. Splenic dynamics of indium-111 labeled platelets in idiopathic thrombocytopenic purpura.J Nucl Med 30: 1546\u20131549, 1989.","journal-title":"J Nucl Med"},{"key":"BF03164802_CR20","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1002\/ajh.2830300404","volume":"30","author":"RS Siegel","year":"1989","unstructured":"Siegel RS, Rae JL, Barth S, et al. Platelet survival and turnover: important factors in predicting response to splenectomy in immune thrombocytopenic purpura.Am J Hematol 30: 206\u2013212, 1989.","journal-title":"Am J Hematol"},{"key":"BF03164802_CR21","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1111\/j.1365-2141.1971.tb03425.x","volume":"21","author":"Y Najean","year":"1971","unstructured":"Najean Y, Ardaillou N. The sequestration site of platelets in idiopathic thrombocytopenic purpura: its correlation with the results of splenectomy.Br J Haematol 21: 153\u2013164, 1971.","journal-title":"Br J Haematol"},{"key":"BF03164802_CR22","first-page":"620","volume":"30","author":"JR Stratton","year":"1989","unstructured":"Stratton JR, Ballem PJ, Gernsheimer T, Cerqueira M, Slichter SJ. Platelet destruction in autoimmune thrombocytopenic purpura: kinetics and clearance of111In-labelled autologous platelets.J Nucl Med 30: 620\u2013637, 1989.","journal-title":"J Nucl Med"},{"key":"BF03164802_CR23","first-page":"81","volume":"55","author":"S Savolainen","year":"1992","unstructured":"Savolainen S, Liewendahl K, Syrj\u00e4l\u00e4 MT, Gripenberg J. Platelet splenic transit times in idiopathic thrombocytopenic purpura: Compartmental vs. non-compartmental model.Int J Hematol 55: 81\u201387, 1992.","journal-title":"Int J Hematol"},{"key":"BF03164802_CR24","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1097\/00006231-199210000-00009","volume":"13","author":"S Savolainen","year":"1992","unstructured":"Savolainen S. SPECT versus planar scintigraphy for quantification of splenic sequestration of111In-labelled platelets.Nucl Med Commun 13: 757\u2013763, 1992.","journal-title":"Nucl Med Commun"},{"key":"BF03164802_CR25","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1097\/00006231-199505000-00009","volume":"16","author":"S Savolainen","year":"1995","unstructured":"Savolainen S, Pohjonen H, Sipil\u00e4 O, Liewendahl K. Segmentation methods for volume determination with111In\/99Tcm SPET.Nucl Med Commun 16: 370\u2013377, 1995.","journal-title":"Nucl Med Commun"},{"key":"BF03164802_CR26","unstructured":"Larsson SA. Gamma camera emission tomography.Acta Radiol Suppl. No. 363, 1980."},{"key":"BF03164802_CR27","unstructured":"Picker Nuclear Medical Imaging Systems. Odyssey VP Operator\u2019s guide, Ohio, Picker International, Inc., Ohio Imaging Division, Bedford Heights, 1995."},{"key":"BF03164802_CR28","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1109\/TPAMI.1987.4767965","volume":"9","author":"KS Arun","year":"1987","unstructured":"Arun KS, Huang TS, Biostein SD: Least-squares fitting of two 3-D point sets.IEEE Trans Patt Anal Mach Intell PAMI-9: 698\u2013700, 1987.","journal-title":"IEEE Trans Patt Anal Mach Intell PAMI"},{"key":"BF03164802_CR29","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1007\/BF00251649","volume":"7","author":"O Reenen van","year":"1982","unstructured":"van Reenen O, L\u00f6tter MG, Heyns A du P, et al. Quantification of the distribution of111In-labelled platelets in organs.Eur J Nucl Med 7: 80\u201384, 1982.","journal-title":"Eur J Nucl Med"},{"key":"BF03164802_CR30","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1097\/00006231-198904000-00007","volume":"10","author":"ST Chandler","year":"1989","unstructured":"Chandler ST. A comparison of liver-spleen ratios and uptakes obtained using planar and tomographic techniques.Nucl Med Commun 10: 297\u2013307, 1989.","journal-title":"Nucl Med Commun"},{"issue":"2","key":"BF03164802_CR31","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1118\/1.596837","volume":"19","author":"DT Long","year":"1992","unstructured":"Long DT, King MA, Sheehan J. Comparative evaluation of image segmentation methods for volume quantitation in SPECT.Med Phys 19 (2): 483\u2013489, 1992.","journal-title":"Med Phys"},{"issue":"2","key":"BF03164802_CR32","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/BF03165014","volume":"8","author":"SE Savolainen","year":"1994","unstructured":"Savolainen SE, Liewendahl BK. Analysis of scintigrams by singular value decomposition (SVD) technique.Ann Nucl Med 8 (2): 101\u2013108, 1994.","journal-title":"Ann Nucl Med"},{"key":"BF03164802_CR33","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1172\/JCI105380","volume":"45","author":"RH Aster","year":"1966","unstructured":"Aster RH. Pooling of platelets in the spleen: role in the pathogenesis of \u201chypersplenic\u201d thrombocytopenia.J Clin Invest 45: 645\u2013657, 1966.","journal-title":"J Clin Invest"},{"key":"BF03164802_CR34","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1182\/blood.V55.5.730.730","volume":"55","author":"LM Kernoff","year":"1980","unstructured":"Kernoff LM, Blake KCH, Shackleton D. Influence of the amount of platelet-bound IgG on platelet survival and site of sequestration in autoimmune thrombocytopenia.Blood 55: 730\u2013733, 1980.","journal-title":"Blood"},{"key":"BF03164802_CR35","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1111\/j.1365-2141.1982.tb03860.x","volume":"52","author":"C Mueller-Eckhardt","year":"1982","unstructured":"Mueller-Eckhardt C, Mueller-Eckhardt G, Kayser W, Voss RM, Wagner J, Kuenzelen E. Platelet associated IgG, platelet survival, and platelet sequestration in thrombocytopenic states.Br J Haematol 52: 49\u201358, 1982.","journal-title":"Br J Haematol"},{"key":"BF03164802_CR36","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1111\/j.1365-2362.1982.tb00992.x","volume":"12","author":"AM Peters","year":"1982","unstructured":"Peters AM, Lavender JP. Factors controlling the intrasplenic transit of platelets.Eur J Clin Invest 12: 191\u2013195, 1982.","journal-title":"Eur J Clin Invest"},{"key":"BF03164802_CR37","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1097\/00006231-198803000-00006","volume":"9","author":"B Luikens","year":"1988","unstructured":"Luikens B, Forstrom LA, Johnson T, Johnson G. Indium-111 platelet kinetics in patients with diabetes mellitus.Nucl Med Commun 9: 223\u2013234, 1988.","journal-title":"Nucl Med Commun"},{"key":"BF03164802_CR38","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1088\/0031-9155\/24\/1\/017","volume":"24","author":"JS Fleming","year":"1979","unstructured":"Fleming JS. A technique for the absolute measurement of activity using a gamma camera and computer.Phys Med Biol 24: 176\u2013180, 1979.","journal-title":"Phys Med Biol"},{"key":"BF03164802_CR39","first-page":"81","volume":"25","author":"LG Strauss","year":"1984","unstructured":"Strauss LG, Clorius JH, Frank T, van Kaick G. Single photon emission computerized tomography (SPECT) for estimates of liver and spleen volume.J Nucl Med 25: 81\u201385, 1984.","journal-title":"J Nucl Med"},{"key":"BF03164802_CR40","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1118\/1.596288","volume":"15","author":"AJ Rensburg van","year":"1988","unstructured":"van Rensburg AJ, L\u00f6tter MG, Heyns A du P, Minnaar PC. An evaluation of four methods of111In planar image quantification.Med Phys 15: 853\u2013861, 1988.","journal-title":"Med Phys"},{"key":"BF03164802_CR41","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1118\/1.596453","volume":"17","author":"JC Yanch","year":"1990","unstructured":"Yanch JC, Flower MA, Webb S. Improved quantification of radionuclide uptake using deconvolution and windowed subtraction techniques for scatter compensation in single photon emission computed tomography.Med Phys 17: 1011\u20131022, 1990.","journal-title":"Med Phys"},{"key":"BF03164802_CR42","volume-title":"Development and evaluation of attenuation and scatter correction techniques for SPECT using the Monte Carlo method","author":"M Ljungberg","year":"1990","unstructured":"Ljungberg M. Development and evaluation of attenuation and scatter correction techniques for SPECT using the Monte Carlo method. Doctoral Dissertation, Department of Radiation Physics, University of Lund, Klippan, Sweden, Ljungbergs Tryckeri AB, 1990."},{"key":"BF03164802_CR43","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1118\/1.595623","volume":"11","author":"CC Harris","year":"1984","unstructured":"Harris CC, Greer KL, Jaszczak RJ, Floyd CE Jr, Fearnow EC, Coleman RE. Tc-99m attenuation coefficient in waterfilled phantoms determined with gamma cameras.Med Phys 11: 681\u2013685, 1984.","journal-title":"Med Phys"},{"key":"BF03164802_CR44","unstructured":"Sipil\u00e4 O, Nikkinen P, Pohjonen H, Poutanen V-P, Karp P, Liewendahl K. Evaluation of registration error in 99mTc-HM-PAO brain SPET and MRI.In European Association of Nuclear Medicine Congress, Brussels, Belgium, 1995.Eur J Nucl Med 22: 767 (Abstract 169), 1995."}],"container-title":["Annals of Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03164802.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF03164802\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03164802","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T14:14:56Z","timestamp":1590156896000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF03164802"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,12]]},"references-count":44,"journal-issue":{"issue":"4","published-print":{"date-parts":[[1996,12]]}},"alternative-id":["BF03164802"],"URL":"https:\/\/doi.org\/10.1007\/bf03164802","relation":{},"ISSN":["0914-7187","1864-6433"],"issn-type":[{"value":"0914-7187","type":"print"},{"value":"1864-6433","type":"electronic"}],"subject":[],"published":{"date-parts":[[1996,12]]}}}