{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T00:08:05Z","timestamp":1789949285696,"version":"4.0.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[1989,2,1]],"date-time":"1989-02-01T00:00:00Z","timestamp":602294400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[1989,2]]},"DOI":"10.1007\/bf03168013","type":"journal-article","created":{"date-parts":[[2009,10,26]],"date-time":"2009-10-26T03:44:36Z","timestamp":1256528676000},"page":"31-38","source":"Crossref","is-referenced-by-count":59,"title":["Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom"],"prefix":"10.1007","volume":"2","author":[{"given":"Scott D.","family":"Boden","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David J.","family":"Goodenough","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles D.","family":"Stockham","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eugene","family":"Jacobs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Dina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert M.","family":"Allman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"BF03168013_CR1","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1148\/radiology.160.2.3726129","volume":"160","author":"WD Reinbold","year":"1988","unstructured":"Reinbold WD, Genant HK, Reiser UJ, et al: Bone mineral content in early-postmenopausal and postmenopausal osteoporotic women: Comparison of measurement methods. Radiology 160:469\u2013478, 1988","journal-title":"Radiology"},{"key":"BF03168013_CR2","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/BF02555236","volume":"41","author":"HK Genant","year":"1987","unstructured":"Genant HK, Steiger P, Block JE, et al: Quantitative computed tomography: Update 1987. Calcif Tissue Int 41:179\u2013186, 1987","journal-title":"Calcif Tissue Int"},{"key":"BF03168013_CR3","doi-asserted-by":"crossref","first-page":"932","DOI":"10.7326\/0003-4819-107-6-932","volume":"107","author":"Health and Public Policy Committee, American College of Physicians","year":"1987","unstructured":"Health and Public Policy Committee, American College of Physicians: Bone mineral densitometry. Ann Intern Med 107:932\u2013936, 1987","journal-title":"Ann Intern Med"},{"key":"BF03168013_CR4","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1007\/BF02563789","volume":"41","author":"RB Mazess","year":"1987","unstructured":"Mazess RB: Bone density in diagnosis of osteoporosis: Thresholds and breakpoints. Calcif Tissue Int 41:117\u2013118, 1987","journal-title":"Calcif Tissue Int"},{"key":"BF03168013_CR5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/8756-3282(85)90399-0","volume":"6","author":"CE Cann","year":"1985","unstructured":"Cann CE, Genant HK, Kolb FO, et al: Quantitative computed tomography for prediction of vertebral fracture risk. Bone 6:1\u20137, 1985","journal-title":"Bone"},{"key":"BF03168013_CR6","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1097\/00004728-198008000-00018","volume":"4","author":"CE Cann","year":"1980","unstructured":"Cann CE, Genant HK: Precise measurement of vertebral mineral content using computed tomography. J Comput Assist Tomogr 4:493\u2013500, 1980","journal-title":"J Comput Assist Tomogr"},{"key":"BF03168013_CR7","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1097\/00004424-198703000-00005","volume":"22","author":"MM Goodsitt","year":"1987","unstructured":"Goodsitt MM, Rosenthal DI, Reinus WR, et al: Two postprocessing CT techniques for determining the composition of trabecular bone. Invest Radiol 22:209\u2013215, 1987","journal-title":"Invest Radiol"},{"key":"BF03168013_CR8","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1088\/0031-9155\/31\/1\/005","volume":"31","author":"RB Merritt","year":"1986","unstructured":"Merritt RB, Chernery SG: Quantitative CT measurements: The effect of scatter acceptance and filter characteristics on the EMI 7070. Phys Med Biol 31:55\u201363, 1986","journal-title":"Phys Med Biol"},{"key":"BF03168013_CR9","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1148\/124.1.99","volume":"124","author":"EC McCullough","year":"1977","unstructured":"McCullough EC: Factors affecting the use of quantitative information from a CT scanner. Radiology 124:99\u2013107, 1977","journal-title":"Radiology"},{"key":"BF03168013_CR10","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/BF00327253","volume":"11","author":"RA Rutherford","year":"1976","unstructured":"Rutherford RA, Pullan BR, Isherwood I: Measurement of effective atomic number and electron density using the EMI scanner. Neuroradiology 11:15\u201321, 1976","journal-title":"Neuroradiology"},{"key":"BF03168013_CR11","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1056\/NEJM198701223160410","volume":"316","author":"FM Hall","year":"1987","unstructured":"Hall FM, Davis MA, Baran DJ: Bone mineral screening for osteoporosis. N Engl J Med 316:212\u2013214, 1987","journal-title":"N Engl J Med"},{"key":"BF03168013_CR12","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1148\/radiology.164.2.3602380","volume":"164","author":"WA Kalender","year":"1987","unstructured":"Kalender WA, Klotz E, Suess C: Vertebral bone mineral analysis: An integrated approach with CT. Radiology 164:419\u2013423, 1987","journal-title":"Radiology"},{"key":"BF03168013_CR13","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1148\/radiology.138.1.7470214","volume":"138","author":"K Imamura","year":"1981","unstructured":"Imamura K, Masamichi F: Empirical beam hardening correction in the measurement of vertebral bone mineral content by computed tomography. Radiology 138:223\u2013226, 1981","journal-title":"Radiology"},{"key":"BF03168013_CR14","unstructured":"Meagher JM, Mote CD, Skinner HB: CT image correction for beam hardening using simulated projection data. Transactions of the 34th Annual Meeting of the Orthopaedic Research Society, Atlanta, 1988"},{"key":"BF03168013_CR15","first-page":"490","volume":"10","author":"A Hemmingsson","year":"1986","unstructured":"Hemmingsson A, Jung B, Ytterbergh C: Dual energy computed tomography: Simulated monoenergetic and material-selective imaging. J Comput Assist Tomogr 10:490\u2013499, 1986","journal-title":"J Comput Assist Tomogr"},{"key":"BF03168013_CR16","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1148\/radiology.162.1.3786773","volume":"162","author":"CE Cann","year":"1987","unstructured":"Cann CE: Quantitative CT applications: Comparison of current scanners. Radiology 162:257\u2013261, 1987","journal-title":"Radiology"},{"key":"BF03168013_CR17","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1097\/00004424-198710000-00006","volume":"22","author":"MM Goodsitt","year":"1987","unstructured":"Goodsitt MM, Rosenthal DI: Quantitative computed tomography scanning for measurement of bone and bone marrow fat content: A comparison of single- and dual-energy techniques using a solid synthetic phantom. Invest Radiol 22:799\u2013810, 1987","journal-title":"Invest Radiol"},{"key":"BF03168013_CR18","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1118\/1.594456","volume":"5","author":"DR White","year":"1978","unstructured":"White DR: Tissue substitutes in experimental radiation physics. Med Phys 5:467\u2013479, 1978","journal-title":"Med Phys"},{"key":"BF03168013_CR19","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1118\/1.594678","volume":"7","author":"GH Glover","year":"1980","unstructured":"Glover GH, Pelc NJ: Nonlinear partial volume artifacts in x-ray computed tomography. Med Phys 7:238\u2013248, 1980","journal-title":"Med Phys"},{"key":"BF03168013_CR20","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1259\/0007-1285-56-665-299","volume":"56","author":"E Breatnach","year":"1983","unstructured":"Breatnach E, Robinson PJ: Repositioning errors in measurement of vertebral attenuation values by computed tomography. Br J Radiol 56:299\u2013305, 1983","journal-title":"Br J Radiol"},{"key":"BF03168013_CR21","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1148\/radiology.166.2.3275985","volume":"166","author":"CE Cann","year":"1988","unstructured":"Cann CE: Quantitative CT for determination of bone mineral density: A review. Radiology 166:509\u2013522, 1988","journal-title":"Radiology"},{"key":"BF03168013_CR22","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1148\/radiology.159.2.3961178","volume":"159","author":"AM Laval-Jeantet","year":"1986","unstructured":"Laval-Jeantet AM, Roger B, Bouysse S, et al: Influence of vertebral fat content on quantitative CT density. Radiology 159:463\u2013466, 1986","journal-title":"Radiology"},{"key":"BF03168013_CR23","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1007\/BF02405022","volume":"35","author":"RB Mazess","year":"1983","unstructured":"Mazess RB Errors in measuring trabecular bone by computed tomography due to marrow and bone composition. Calcif Tissue Int 35:148\u2013152, 1983","journal-title":"Calcif Tissue Int"},{"key":"BF03168013_CR24","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/00004424-198505000-00014","volume":"20","author":"DI Rosenthal","year":"1985","unstructured":"Rosenthal DI, Ganott MA, Wyshak G, et al: Quantitative computed tomography for spinal density measurement: Factors affecting precision. Invest Radiol 20:306\u2013310, 1985","journal-title":"Invest Radiol"}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03168013.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/BF03168013\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BF03168013","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,21]],"date-time":"2019-05-21T22:56:40Z","timestamp":1558479400000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BF03168013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1989,2]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1989,2]]}},"alternative-id":["BF03168013"],"URL":"https:\/\/doi.org\/10.1007\/bf03168013","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"value":"0897-1889","type":"print"},{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[1989,2]]}}}