{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,14]],"date-time":"2026-02-14T00:15:00Z","timestamp":1771028100572,"version":"3.50.1"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2021,4,23]],"date-time":"2021-04-23T00:00:00Z","timestamp":1619136000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,4,23]],"date-time":"2021-04-23T00:00:00Z","timestamp":1619136000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orofac Orthop"],"published-print":{"date-parts":[[2022,9]]},"DOI":"10.1007\/s00056-021-00295-1","type":"journal-article","created":{"date-parts":[[2021,4,25]],"date-time":"2021-04-25T03:00:40Z","timestamp":1619319640000},"page":"307-317","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Customized lingual brackets vs. conventional labial brackets for initial alignment","Individuell angepasste Lingualbrackets vs. konventionelle Labialbrackets zur Erstausrichtung"],"prefix":"10.1007","volume":"83","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4671-0695","authenticated-orcid":false,"given":"Murat","family":"Kapta\u00e7","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1455-9855","authenticated-orcid":false,"given":"Yazg\u0131","family":"Ay \u00dcn\u00fcvar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,4,23]]},"reference":[{"issue":"3","key":"295_CR1","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1016\/j.ajodo.2015.05.015","volume":"148","author":"D Wiechmann","year":"2015","unstructured":"Wiechmann\u00a0D, Klang\u00a0E, Helms\u00a0HJ, Kn\u00f6sel\u00a0M (2015) Lingual appliances reduce the incidence of white spot lesions during orthodontic multibracket treatment. Am J Orthod Dentofacial Orthop 148(3):414\u2013422. https:\/\/doi.org\/10.1016\/j.ajodo.2015.05.015","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"3","key":"295_CR2","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1016\/j.ajodo.2005.07.018","volume":"131","author":"NR Turnbull","year":"2007","unstructured":"Turnbull\u00a0NR, Birnie\u00a0DJ (2007) Treatment efficiency of conventional vs self-ligating brackets: effects of archwire size and material. Am J Orthod Dentofacial Orthop 131(3):395\u2013399. https:\/\/doi.org\/10.1016\/j.ajodo.2005.07.018","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"5","key":"295_CR3","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1007\/s00056-007-0714-1","volume":"68","author":"S Lovrov","year":"2007","unstructured":"Lovrov\u00a0S, Hertrich\u00a0K, Hirschelder\u00a0U (2007) Enamel demineralization during fixed orthodontic treatment-incidence and correlation to various oral-hygine parameters. J\u00a0Orofac Orthop 68(5):353\u2013363. https:\/\/doi.org\/10.1007\/s00056-007-0714-1","journal-title":"J Orofac Orthop"},{"issue":"4","key":"295_CR4","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1093\/ejo\/cji034","volume":"27","author":"T Stamm","year":"2005","unstructured":"Stamm\u00a0T, Hohoff\u00a0A, Ehmer\u00a0U (2005) A subjective comparison of two lingual bracket systems. Eur J Orthod 27(4):420\u2013426. https:\/\/doi.org\/10.1093\/ejo\/cji034","journal-title":"Eur J Orthod"},{"issue":"5","key":"295_CR5","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1007\/s00056-003-0325-4","volume":"64","author":"D Wiechmann","year":"2003","unstructured":"Wiechmann\u00a0D (2003) A new bracket system for lingual orthodontic treatment. Part 2: first clinical experiences and further development. J\u00a0Orofac Orthop 64(5):372\u2013388. https:\/\/doi.org\/10.1007\/s00056-003-0325-4","journal-title":"J Orofac Orthop"},{"issue":"3","key":"295_CR6","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1007\/s00056-002-0211-5","volume":"63","author":"D Wiechmann","year":"2002","unstructured":"Wiechmann\u00a0D (2002) A new bracket system for lingual orthodontic treatment. Part 1: theoretical background and development. J\u00a0Orofac Orthop 63(3):234\u2013245. https:\/\/doi.org\/10.1007\/s00056-002-0211-5","journal-title":"J Orofac Orthop"},{"issue":"3","key":"295_CR7","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1053\/j.sodo.2006.05.005","volume":"12","author":"R Romano","year":"2006","unstructured":"Romano\u00a0R (2006) Concepts on control of the anterior teeth using the lingual appliance. Semin Orthod 12(3):178\u2013185. https:\/\/doi.org\/10.1053\/j.sodo.2006.05.005","journal-title":"Semin Orthod"},{"issue":"2","key":"295_CR8","first-page":"195","volume":"74","author":"S Geron","year":"2004","unstructured":"Geron\u00a0S, Romano\u00a0R, Brosh\u00a0T (2004) Vertical forces in labial and lingual orthodontics applied on maxillary incisors\u23afa theoretical approach. Angle Orthod 74(2):195\u2013201. https:\/\/doi.org\/10.1043\/0003-3219(2004)074\u30080195:vfilal\u30092.0.co;2","journal-title":"Angle Orthod"},{"issue":"S1","key":"295_CR9","doi-asserted-by":"publisher","first-page":"S27","DOI":"10.1179\/1465313313y.0000000073","volume":"40","author":"A Auluck","year":"2013","unstructured":"Auluck\u00a0A (2013) Lingual orthodontic treatment: what is the current evidence base? J\u00a0Orthod 40(S1):S27\u2013S33. https:\/\/doi.org\/10.1179\/1465313313y.0000000073","journal-title":"J Orthod"},{"issue":"4","key":"295_CR10","doi-asserted-by":"publisher","first-page":"470.e1","DOI":"10.1016\/j.ajodo.2008.04.018","volume":"134","author":"P Scott","year":"2008","unstructured":"Scott\u00a0P, DiBiase\u00a0AT, Sherriff\u00a0M, Cobourne\u00a0MT (2008) Alignment efficiency of Damon3 self-ligating and conventional orthodontic bracket systems: a\u00a0randomized clinical trial. Am J Orthod Dentofacial Orthop 134(4):470.e1\u2013470.e8. https:\/\/doi.org\/10.1016\/j.ajodo.2008.04.018","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"6","key":"295_CR11","doi-asserted-by":"publisher","first-page":"738","DOI":"10.1016\/j.ajodo.2009.06.023","volume":"137","author":"PS Fleming","year":"2010","unstructured":"Fleming\u00a0PS, DiBiase\u00a0AT, Lee\u00a0RT (2010) Randomized clinical trial of orthodontic treatment efficiency with self-ligating and conventional fixed orthodontic appliances. Am J Orthod Dentofacial Orthop 137(6):738\u2013742. https:\/\/doi.org\/10.1016\/j.ajodo.2009.06.023","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"6","key":"295_CR12","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1093\/ejo\/cjy005","volume":"40","author":"A Alobeid","year":"2018","unstructured":"Alobeid\u00a0A, El-Bialy\u00a0T, Reimann\u00a0S, Keilig\u00a0L, Cornelius\u00a0D, J\u00e4ger\u00a0A, Bourauel\u00a0C (2018) Comparison of the efficacy of tooth alignment among lingual and labial brackets: an in vitro study. Eur J Orthod 40(6):660\u2013665. https:\/\/doi.org\/10.1093\/ejo\/cjy005","journal-title":"Eur J Orthod"},{"issue":"5","key":"295_CR13","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1016\/0002-9416(75)90086-x","volume":"68","author":"RM Little","year":"1975","unstructured":"Little\u00a0RM (1975) The irregularity index: a quantitative score of mandibular anterior alignment. Am J Orthod Dentofacial Orthop 68(5):554\u2013563. https:\/\/doi.org\/10.1016\/0002-9416(75)90086-x","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"3","key":"295_CR14","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1093\/ejo\/cjs029","volume":"35","author":"I Sifakakis","year":"2013","unstructured":"Sifakakis\u00a0I, Pandis\u00a0N, Makou\u00a0M, Eliades\u00a0T, Katsaros\u00a0C, Bourauel\u00a0C (2013) A comparative assessment of torque generated by lingual and conventional brackets. Eur J Orthod 35(3):375\u2013380. https:\/\/doi.org\/10.1093\/ejo\/cjs029","journal-title":"Eur J Orthod"},{"issue":"1","key":"295_CR15","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1093\/ejo\/cjr048","volume":"35","author":"I Sifakakis","year":"2013","unstructured":"Sifakakis\u00a0I, Pandis\u00a0N, Makou\u00a0M, Katsaros\u00a0C, Eliades\u00a0T, Bourauel\u00a0C (2013) A comparative assessment of forces and moments generated by lingual and conventional brackets. Eur J Orthod 35(1):82\u201386. https:\/\/doi.org\/10.1093\/ejo\/cjr048","journal-title":"Eur J Orthod"},{"issue":"5","key":"295_CR16","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1016\/s0889-5406(94)70069-9","volume":"106","author":"PK Shivapuja","year":"1994","unstructured":"Shivapuja\u00a0PK, Berger\u00a0J (1994) A comparative study of conventional ligation and self\u2013ligation bracket systems. Am J Orthod Dentofacial Orthop 106(5):472\u2013480. https:\/\/doi.org\/10.1016\/s0889-5406(94)70069-9","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"3","key":"295_CR17","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1067\/mod.2002.126156","volume":"122","author":"GA Thorstenson","year":"2002","unstructured":"Thorstenson\u00a0GA, Kusy\u00a0RP (2002) Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry state. Am J Orthod Dentofacial Orthop 122(3):295\u2013305. https:\/\/doi.org\/10.1067\/mod.2002.126156","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"6","key":"295_CR18","first-page":"1041","volume":"75","author":"S Tecco","year":"2005","unstructured":"Tecco\u00a0S, Festa\u00a0F, Caputi\u00a0S, Traini\u00a0T, Di lorio\u00a0D, D\u2019Attilio\u00a0M (2005) Friction of conventional and self-ligating brackets using a\u00a010 bracket model. Angle Orthod 75(6):1041\u20131045. https:\/\/doi.org\/10.1043\/0003-3219(2005)75[1041:focasb]2.0.co;2","journal-title":"Angle Orthod"},{"issue":"1","key":"295_CR19","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1111\/ocr.12057","volume":"18","author":"MA Montasser","year":"2015","unstructured":"Montasser\u00a0MA, Keilig\u00a0L, Bourauel\u00a0C (2015) An in vitro study into the efficacy of complex tooth alignment with conventional and self-ligating brackets. Orthod Craniofac Res 18(1):33\u201342. https:\/\/doi.org\/10.1111\/ocr.12057","journal-title":"Orthod Craniofac Res"},{"issue":"3","key":"295_CR20","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/j.ajodo.2007.08.030","volume":"136","author":"PS Fleming","year":"2009","unstructured":"Fleming\u00a0PS, DiBiase\u00a0AT, Sarri\u00a0G, Lee\u00a0RT (2009) Comparison of mandibular arch changes during alignment and levelling with 2 preadjusted edgewise appliances. Am J Orthod Dentofacial Orthop 136(3):340\u2013347. https:\/\/doi.org\/10.1016\/j.ajodo.2007.08.030","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"295_CR21","doi-asserted-by":"publisher","first-page":"138.e1","DOI":"10.1016\/j.ajodo.2010.03.020","volume":"138","author":"E Ong","year":"2010","unstructured":"Ong\u00a0E, McCallum\u00a0H, Griffin\u00a0MP, Ho\u00a0C (2010) Efficiency of self-ligating vs conventionally ligated brackets during initial alignment. Am J Orthod Dentofacial Orthop 138(2):138.e1\u2013138.e7. https:\/\/doi.org\/10.1016\/j.ajodo.2010.03.020","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"5","key":"295_CR22","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1007\/s00056-005-0442-3","volume":"66","author":"LM Fuck","year":"2005","unstructured":"Fuck\u00a0LM, Wiechmann\u00a0D, Drescher\u00a0D (2005) Comparison of the initial orthodontic force systems produced by a\u00a0new lingual bracket system and a\u00a0straight-wire appliance. J\u00a0Orofac Orthop 66(5):363\u2013376. https:\/\/doi.org\/10.1007\/s00056-005-0442-3","journal-title":"J Orofac Orthop"},{"issue":"1","key":"295_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13005-020-00221-7","volume":"16","author":"D Wiechmann","year":"2020","unstructured":"Wiechmann\u00a0D, Bantleon\u00a0HP, Melsen\u00a0B, Zachrisson\u00a0B, H\u00e4gg\u00a0U, Canal\u00a0P et\u00a0al (2020) Incorrect measurements and misleading conclusions in the article \u201cComparison of the efficacy of tooth alignment among lingual and labial brackets: an in vitro study\u201d. Head Face Med 16(1):1\u20135. https:\/\/doi.org\/10.1186\/s13005-020-00221-7","journal-title":"Head Face Med"},{"issue":"5","key":"295_CR24","doi-asserted-by":"publisher","first-page":"561","DOI":"10.5005\/jp-journals-10024-1579","volume":"15","author":"TZ Khattab","year":"2014","unstructured":"Khattab\u00a0TZ, Hajeer\u00a0MY, Farah\u00a0H, Al-Sabbagh\u00a0R (2014) Maxillary dental arch changes following the leveling and alignment stage with lingual and labial orthodontic appliances: a\u00a0preliminary report of a\u00a0randomized controlled trial. J\u00a0Contemp Dent Pract 15(5):561\u2013566. https:\/\/doi.org\/10.5005\/jp-journals-10024-1579","journal-title":"J Contemp Dent Pract"},{"issue":"4","key":"295_CR25","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/j.ortho.2013.09.005","volume":"11","author":"L Lombardo","year":"2013","unstructured":"Lombardo\u00a0L, Fattori\u00a0L, Molinari\u00a0C, Mirabella\u00a0D, Siciliani\u00a0G (2013) Dental and alveolar arch forms in a\u00a0Caucasian population compared with commercially available archwires. Int Orthod 11(4):389\u2013421. https:\/\/doi.org\/10.1016\/j.ortho.2013.09.005","journal-title":"Int Orthod"},{"issue":"2","key":"295_CR26","doi-asserted-by":"publisher","first-page":"89","DOI":"10.4041\/kjod.2015.45.2.89","volume":"45","author":"M Celikoglu","year":"2015","unstructured":"Celikoglu\u00a0M, Bayram\u00a0M, Nur\u00a0M, Kilkis\u00a0D (2015) Mandibular changes during initial alignment with SmartClip self-ligating and conventional brackets: A single-center prospective randomized controlled clinical trial. Korean J Orthod 45(2):89\u201394. https:\/\/doi.org\/10.4041\/kjod.2015.45.2.89","journal-title":"Korean J Orthod"}],"container-title":["Journal of Orofacial Orthopedics \/ Fortschritte der Kieferorthop\u00e4die"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00056-021-00295-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00056-021-00295-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00056-021-00295-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,22]],"date-time":"2022-08-22T15:07:16Z","timestamp":1661180836000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00056-021-00295-1"}},"subtitle":["A\u00a0randomized clinical trial","Eine randomisierte klinische Studie"],"short-title":[],"issued":{"date-parts":[[2021,4,23]]},"references-count":26,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,9]]}},"alternative-id":["295"],"URL":"https:\/\/doi.org\/10.1007\/s00056-021-00295-1","relation":{},"ISSN":["1434-5293","1615-6714"],"issn-type":[{"value":"1434-5293","type":"print"},{"value":"1615-6714","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,23]]},"assertion":[{"value":"18 September 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 March 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"M.\u00a0Kapta\u00e7 and Y.\u00a0Ay \u00dcn\u00fcvar declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee (the ethics committee of Ayd\u0131n Adnan Menderes University, Medicine School [2016\/897]) and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. All patients and legal guardians gave written informed consent before participation. This trial is registered at ClinicalTrials.gov (NCT04357067). Written informed consent was obtained from the patients for publication of this research and accompanying images.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical standards"}},{"value":"NCT04357067 retrospectively registered at ClinicalTrials.gov on 21\u00a0April\u00a02020.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Trial registration number"}}]}}