{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:13:20Z","timestamp":1786979600522,"version":"build-2736575974"},"reference-count":47,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2024,1,15]],"date-time":"2024-01-15T00:00:00Z","timestamp":1705276800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,1,15]],"date-time":"2024-01-15T00:00:00Z","timestamp":1705276800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orofac Orthop"],"published-print":{"date-parts":[[2025,5]]},"DOI":"10.1007\/s00056-023-00508-9","type":"journal-article","created":{"date-parts":[[2024,1,15]],"date-time":"2024-01-15T07:02:16Z","timestamp":1705302136000},"page":"170-181","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Functionality testing of an innovative biomechanically optimized and surface-modified orthodontic mini-screw\u2014a comparative study","Funktionspr\u00fcfung einer innovativen biomechanisch optimierten und oberfl\u00e4chenmodifizierten kieferorthop\u00e4dischen Minischraube\u00a0\u2013 eine vergleichende Studie"],"prefix":"10.1007","volume":"86","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2401-6827","authenticated-orcid":false,"given":"Kathrin","family":"Duske","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Billan","family":"Turan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cornelia","family":"Prinz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8838-1164","authenticated-orcid":false,"given":"Jan Hendrik","family":"Lenz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9636-6087","authenticated-orcid":false,"given":"Franka","family":"Stahl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mareike","family":"Warkentin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,1,15]]},"reference":[{"issue":"1","key":"508_CR1","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.ortho.2019.01.006","volume":"17","author":"M Azeem","year":"2019","unstructured":"Azeem\u00a0M, Saleem\u00a0MM, Liaquat\u00a0A et\u00a0al (2019) Failure rates of mini-implants inserted in the retromolar area. Int Orthod 17(1):53\u201359. https:\/\/doi.org\/10.1016\/j.ortho.2019.01.006","journal-title":"Int Orthod"},{"issue":"3","key":"508_CR2","doi-asserted-by":"publisher","first-page":"193","DOI":"10.5500\/wjt.v7.i3.193","volume":"7","author":"C Bergemann","year":"2017","unstructured":"Bergemann\u00a0C, Zaatreh\u00a0S, Wegner\u00a0K et\u00a0al (2017) Copper as an alternative antimicrobial coating for implants\u2014an in vitro study. WJT 7(3):193\u2013202. https:\/\/doi.org\/10.5500\/wjt.v7.i3.193","journal-title":"WJT"},{"issue":"6","key":"508_CR3","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1302\/0301-620X.93B6.24986","volume":"93","author":"RHM ten Broeke","year":"2011","unstructured":"ten Broeke\u00a0RHM, Alves\u00a0A, Baumann\u00a0A et\u00a0al (2011) Bone reaction to a\u00a0biomimetic third-generation hydroxyapatite coating and new surface treatment for the symax hip stem. J\u00a0Bone Joint Surg Br 93(6):760\u2013768. https:\/\/doi.org\/10.1302\/0301-620X.93B6.24986","journal-title":"J Bone Joint Surg Br"},{"key":"508_CR4","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.biomaterials.2014.12.022","volume":"44","author":"I Burghardt","year":"2015","unstructured":"Burghardt\u00a0I, L\u00fcthen\u00a0F, Prinz\u00a0C et\u00a0al (2015) A dual function of copper in designing regenerative implants. Biomaterials 44:36\u201344. https:\/\/doi.org\/10.1016\/j.biomaterials.2014.12.022","journal-title":"Biomaterials"},{"issue":"3","key":"508_CR5","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1016\/j.ajodo.2011.09.008","volume":"141","author":"JZ-C Chang","year":"2012","unstructured":"Chang\u00a0JZ\u2011C, Chen\u00a0Y\u2011J, Tung\u00a0Y\u2011Y et\u00a0al (2012) Effects of thread depth, taper shape, and taper length on the mechanical properties of mini-implants. Am J Orthod Dentofacial Orthop 141(3):279\u2013288. https:\/\/doi.org\/10.1016\/j.ajodo.2011.09.008","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"508_CR6","first-page":"283","volume":"21","author":"Y-J Chen","year":"2006","unstructured":"Chen\u00a0Y\u2011J, Chen\u00a0Y\u2011H, Lin\u00a0L\u2011D et\u00a0al (2006) Removal torque of miniscrews used for orthodontic anchorage\u2014a preliminary report. Int J Oral Maxillofac Implants 21(2):283\u2013289","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"1","key":"508_CR7","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.ajodo.2008.01.027","volume":"137","author":"AG Crismani","year":"2010","unstructured":"Crismani\u00a0AG, Bertl\u00a0MH, Celar\u00a0AG et\u00a0al (2010) Miniscrews in orthodontic treatment: review and analysis of published clinical trials. Am J Orthod Dentofacial Orthop 137(1):108\u2013113. https:\/\/doi.org\/10.1016\/j.ajodo.2008.01.027","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"5","key":"508_CR8","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1007\/s00784-016-1770-y","volume":"20","author":"E Espinar-Escalona","year":"2016","unstructured":"Espinar-Escalona\u00a0E, Bravo-Gonzalez\u00a0L\u2011A, Pegueroles\u00a0M et\u00a0al (2016) Roughness and wettability effect on histological and mechanical response of self-drilling orthodontic mini-implants. Clin Oral Investig 20(5):1115\u20131120. https:\/\/doi.org\/10.1007\/s00784-016-1770-y","journal-title":"Clin Oral Investig"},{"issue":"5","key":"508_CR9","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1093\/ejo\/cjm062","volume":"29","author":"LG Favero","year":"2007","unstructured":"Favero\u00a0LG, Pisoni\u00a0A, Paganelli\u00a0C (2007) Removal torque of osseointegrated mini-implants: an in vivo evaluation. Eur J Orthod 29(5):443\u2013448. https:\/\/doi.org\/10.1093\/ejo\/cjm062","journal-title":"Eur J Orthod"},{"key":"508_CR10","doi-asserted-by":"publisher","first-page":"7520959","DOI":"10.1155\/2016\/7520959","volume":"2016","author":"O Gansukh","year":"2016","unstructured":"Gansukh\u00a0O, Jeong\u00a0J\u2011W, Kim\u00a0J\u2011W et\u00a0al (2016) Mechanical and histological effects of resorbable blasting media surface treatment on the initial stability of orthodontic mini-implants. Biomed Res Int 2016:7520959. https:\/\/doi.org\/10.1155\/2016\/7520959","journal-title":"Biomed Res Int"},{"issue":"1","key":"508_CR11","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1186\/s13568-018-0554-y","volume":"8","author":"H Gollwitzer","year":"2018","unstructured":"Gollwitzer\u00a0H, Haenle\u00a0M, Mittelmeier\u00a0W et\u00a0al (2018) A biocompatible sol-gel derived titania coating for medical implants with antibacterial modification by copper integration. AMB Expr 8(1):24. https:\/\/doi.org\/10.1186\/s13568-018-0554-y","journal-title":"AMB Expr"},{"issue":"1","key":"508_CR12","doi-asserted-by":"publisher","first-page":"25","DOI":"10.26650\/eor.20197993","volume":"53","author":"CA Hergel","year":"2019","unstructured":"Hergel\u00a0CA, Acar\u00a0YB, Ates\u00a0M et\u00a0al (2019) In-vitro evaluation of the effects of insertion and sterilization procedures on the mechanical and surface characteristics of mini screws. Eur Oral Res 53(1):25\u201331. https:\/\/doi.org\/10.26650\/eor.20197993","journal-title":"Eur Oral Res"},{"issue":"3","key":"508_CR13","doi-asserted-by":"publisher","first-page":"347","DOI":"10.2334\/josnusd.51.347","volume":"51","author":"M Inaba","year":"2009","unstructured":"Inaba\u00a0M (2009) Evaluation of primary stability of inclined orthodontic mini-implants. J\u00a0Oral Sci 51(3):347\u2013353. https:\/\/doi.org\/10.2334\/josnusd.51.347","journal-title":"J Oral Sci"},{"issue":"5","key":"508_CR14","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1097\/ID.0000000000000138","volume":"23","author":"M Inoue","year":"2014","unstructured":"Inoue\u00a0M, Kuroda\u00a0S, Yasue\u00a0A et\u00a0al (2014) Torque ratio as a\u00a0predictable factor on primary stability of orthodontic miniscrew implants. Implant Dent 23(5):576\u2013581. https:\/\/doi.org\/10.1097\/ID.0000000000000138","journal-title":"Implant Dent"},{"issue":"1","key":"508_CR15","first-page":"75","volume":"23","author":"KI Janssen","year":"2008","unstructured":"Janssen\u00a0KI, Raghoebar\u00a0GM, Vissink\u00a0A et\u00a0al (2008) Skeletal anchorage in orthodontics\u2014a review of various systems in animal and human studies. Int J Oral Maxillofac Implants 23(1):75\u201388","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"508_CR16","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1093\/ejo\/cjv017","volume":"38","author":"H-K Kang","year":"2016","unstructured":"Kang\u00a0H\u2011K, Chu\u00a0T\u2011M, Dechow\u00a0P et\u00a0al (2016) Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis. Eur J Orthod 38(2):154\u2013162. https:\/\/doi.org\/10.1093\/ejo\/cjv017","journal-title":"Eur J Orthod"},{"issue":"4","key":"508_CR17","doi-asserted-by":"publisher","first-page":"559","DOI":"10.11607\/prd.2675","volume":"36","author":"J-W Kim","year":"2016","unstructured":"Kim\u00a0J\u2011W, Lee\u00a0N\u2011K, Sim\u00a0H\u2011Y et\u00a0al (2016) Failure of orthodontic mini-implants by patient age, sex, and arch; number of primary insertions; and frequency of reinsertions after failure: an analysis of the implant failure rate and patient failure rate. Int J Periodontics Restorative Dent 36(4):559\u2013565. https:\/\/doi.org\/10.11607\/prd.2675","journal-title":"Int J Periodontics Restorative Dent"},{"issue":"1","key":"508_CR18","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.ajodo.2006.07.038","volume":"134","author":"S-H Kim","year":"2008","unstructured":"Kim\u00a0S\u2011H, Cho\u00a0J\u2011H, Chung\u00a0K\u2011R et\u00a0al (2008) Removal torque values of surface-treated mini-implants after loading. Am J Orthod Dentofacial Orthop 134(1):36\u201343. https:\/\/doi.org\/10.1016\/j.ajodo.2006.07.038","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"5","key":"508_CR19","doi-asserted-by":"publisher","first-page":"899","DOI":"10.2319\/090608-466.1","volume":"79","author":"S-H Kim","year":"2009","unstructured":"Kim\u00a0S\u2011H, Lee\u00a0S\u2011J, Cho\u00a0I\u2011S et\u00a0al (2009) Rotational resistance of surface-treated mini-implants. Angle Orthod 79(5):899\u2013907. https:\/\/doi.org\/10.2319\/090608-466.1","journal-title":"Angle Orthod"},{"issue":"5","key":"508_CR20","doi-asserted-by":"publisher","first-page":"908","DOI":"10.2319\/071808-374.1","volume":"79","author":"Y-K Kim","year":"2009","unstructured":"Kim\u00a0Y\u2011K, Kim\u00a0Y\u2011J, Yun\u00a0P\u2011Y et\u00a0al (2009) Effects of the taper shape, dual-thread, and length on the mechanical properties of mini-implants. Angle Orthod 79(5):908\u2013914. https:\/\/doi.org\/10.2319\/071808-374.1","journal-title":"Angle Orthod"},{"issue":"2","key":"508_CR21","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1080\/17453674.2019.1709956","volume":"91","author":"DSMG Kruijntjens","year":"2020","unstructured":"Kruijntjens\u00a0DSMG, Koster\u00a0L, Kaptein\u00a0BL et\u00a0al (2020) Early stabilization of the uncemented Symax hip stem in a\u00a02-year RSA study. Acta Orthop 91(2):159\u2013164. https:\/\/doi.org\/10.1080\/17453674.2019.1709956","journal-title":"Acta Orthop"},{"issue":"2","key":"508_CR22","doi-asserted-by":"publisher","first-page":"234","DOI":"10.2319\/121206-507.1","volume":"78","author":"S-A Lim","year":"2008","unstructured":"Lim\u00a0S\u2011A, Cha\u00a0J\u2011Y, Hwang\u00a0C\u2011J (2008) Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length. Angle Orthod 78(2):234\u2013240. https:\/\/doi.org\/10.2319\/121206-507.1","journal-title":"Angle Orthod"},{"issue":"1","key":"508_CR23","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1034\/j.1600-0544.2000.030105.x","volume":"3","author":"B Melsen","year":"2000","unstructured":"Melsen\u00a0B, Costa\u00a0A (2000) Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res 3(1):23\u201328. https:\/\/doi.org\/10.1034\/j.1600-0544.2000.030105.x","journal-title":"Clin Orthod Res"},{"key":"508_CR24","unstructured":"Meredith N (1998) Assessment of implant stability as a\u00a0prognostic determinant. Int J Prosthodont (11):491\u2013501"},{"issue":"11","key":"508_CR25","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1177\/0954411913495986","volume":"227","author":"R Meursinge Reynders","year":"2013","unstructured":"Meursinge Reynders\u00a0R, Ronchi\u00a0L, Ladu\u00a0L et\u00a0al (2013) Insertion torque and orthodontic mini-implants: a\u00a0systematic review of the artificial bone literature. Proc Inst Mech Eng\u00a0H 227(11):1181\u20131202. https:\/\/doi.org\/10.1177\/0954411913495986","journal-title":"Proc Inst Mech Eng H"},{"issue":"1","key":"508_CR26","doi-asserted-by":"publisher","first-page":"123","DOI":"10.2319\/030309-123.1","volume":"80","author":"S-S Mo","year":"2010","unstructured":"Mo\u00a0S\u2011S, Kim\u00a0S\u2011H, Kook\u00a0Y\u2011A et\u00a0al (2010) Resistance to immediate orthodontic loading of surface-treated mini-implants. Angle Orthod 80(1):123\u2013129. https:\/\/doi.org\/10.2319\/030309-123.1","journal-title":"Angle Orthod"},{"issue":"1","key":"508_CR27","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s40510-020-00347-z","volume":"22","author":"SF Moghaddam","year":"2021","unstructured":"Moghaddam\u00a0SF, Mohammadi\u00a0A, Behroozian\u00a0A (2021) The effect of sandblasting and acid etching on survival rate of orthodontic miniscrews: a\u00a0split-mouth randomized controlled trial. Prog Orthod 22(1):2. https:\/\/doi.org\/10.1186\/s40510-020-00347-z","journal-title":"Prog Orthod"},{"issue":"1","key":"508_CR28","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1186\/s40510-018-0225-1","volume":"19","author":"H Mohammed","year":"2018","unstructured":"Mohammed\u00a0H, Wafaie\u00a0K, Rizk\u00a0MZ et\u00a0al (2018) Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a\u00a0systematic review and meta-analysis. Prog Orthod 19(1):36. https:\/\/doi.org\/10.1186\/s40510-018-0225-1","journal-title":"Prog Orthod"},{"issue":"1","key":"508_CR29","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1111\/j.1600-0501.2005.01211.x","volume":"17","author":"M Motoyoshi","year":"2006","unstructured":"Motoyoshi\u00a0M, Hirabayashi\u00a0M, Uemura\u00a0M et\u00a0al (2006) Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 17(1):109\u2013114. https:\/\/doi.org\/10.1111\/j.1600-0501.2005.01211.x","journal-title":"Clin Oral Implants Res"},{"issue":"8","key":"508_CR30","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1016\/j.ijom.2007.03.009","volume":"36","author":"M Motoyoshi","year":"2007","unstructured":"Motoyoshi\u00a0M, Matsuoka\u00a0M, Shimizu\u00a0N (2007) Application of orthodontic mini-implants in adolescents. Int J Oral Maxillofac Surg 36(8):695\u2013699. https:\/\/doi.org\/10.1016\/j.ijom.2007.03.009","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"1","key":"508_CR31","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1093\/ejo\/cjx026","volume":"40","author":"MV Nguyen","year":"2018","unstructured":"Nguyen\u00a0MV, Codrington\u00a0J, Fletcher\u00a0L et\u00a0al (2018) The influence of miniscrew insertion torque. Eur J Orthod 40(1):37\u201344. https:\/\/doi.org\/10.1093\/ejo\/cjx026","journal-title":"Eur J Orthod"},{"issue":"3","key":"508_CR32","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1007\/s11999-016-4713-7","volume":"475","author":"GA Norambuena","year":"2017","unstructured":"Norambuena\u00a0GA, Patel\u00a0R, Karau\u00a0M et\u00a0al (2017) Antibacterial and biocompatible titanium-copper oxide coating may be a\u00a0potential strategy to reduce periprosthetic infection: an In vitro study. Clin Orthop Relat Res 475(3):722\u2013732. https:\/\/doi.org\/10.1007\/s11999-016-4713-7","journal-title":"Clin Orthop Relat Res"},{"key":"508_CR33","doi-asserted-by":"publisher","first-page":"838356","DOI":"10.1155\/2014\/838356","volume":"2014","author":"N-H Oh","year":"2014","unstructured":"Oh\u00a0N\u2011H, Kim\u00a0E\u2011Y, Paek\u00a0J et\u00a0al (2014) Evaluation of stability of surface-treated mini-implants in diabetic rabbits. Int J Dent 2014:838356. https:\/\/doi.org\/10.1155\/2014\/838356","journal-title":"Int J Dent"},{"issue":"7","key":"508_CR34","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.ijom.2008.04.007","volume":"37","author":"J Okazaki","year":"2008","unstructured":"Okazaki\u00a0J, Komasa\u00a0Y, Sakai\u00a0D et\u00a0al (2008) A torque removal study on the primary stability of orthodontic titanium screw mini-implants in the cortical bone of dog femurs. Int J Oral Maxillofac Surg 37(7):647\u2013650. https:\/\/doi.org\/10.1016\/j.ijom.2008.04.007","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"5","key":"508_CR35","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1016\/j.ajodo.2012.05.016","volume":"142","author":"SN Papageorgiou","year":"2012","unstructured":"Papageorgiou\u00a0SN, Zogakis\u00a0IP, Papadopoulos\u00a0MA (2012) Failure rates and associated risk factors of orthodontic miniscrew implants: a\u00a0meta-analysis. Am J Orthod Dentofacial Orthop 142(5):577\u2013595.e7. https:\/\/doi.org\/10.1016\/j.ajodo.2012.05.016","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"3","key":"508_CR36","doi-asserted-by":"publisher","first-page":"411","DOI":"10.2319\/031618-211.1","volume":"89","author":"H-J Park","year":"2019","unstructured":"Park\u00a0H\u2011J, Choi\u00a0S\u2011H, Choi\u00a0YJ et\u00a0al (2019) A prospective, split-mouth, clinical study of orthodontic titanium miniscrews with machined and acid-etched surfaces. Angle Orthod 89(3):411\u2013417. https:\/\/doi.org\/10.2319\/031618-211.1","journal-title":"Angle Orthod"},{"issue":"1","key":"508_CR37","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.ajodo.2004.11.032","volume":"130","author":"H-S Park","year":"2006","unstructured":"Park\u00a0H\u2011S, Jeong\u00a0S\u2011H, Kwon\u00a0O\u2011W (2006) Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 130(1):18\u201325. https:\/\/doi.org\/10.1016\/j.ajodo.2004.11.032","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"508_CR38","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1177\/0885328217713356","volume":"32","author":"C Prinz","year":"2017","unstructured":"Prinz\u00a0C, Elhensheri\u00a0M, Rychly\u00a0J et\u00a0al (2017) Antimicrobial and bone-forming activity of a\u00a0copper coated implant in a\u00a0rabbit model. J\u00a0Biomater Appl 32(2):139\u2013149. https:\/\/doi.org\/10.1177\/0885328217713356","journal-title":"J Biomater Appl"},{"issue":"2","key":"508_CR39","doi-asserted-by":"publisher","first-page":"85","DOI":"10.15171\/joddd.2019.013","volume":"13","author":"AH Sadr Haghighi","year":"2019","unstructured":"Sadr Haghighi\u00a0AH, Pouyafar\u00a0V, Navid\u00a0A et\u00a0al (2019) Investigation of the optimal design of orthodontic mini-implants based on the primary stability: A\u00a0finite element analysis. J\u00a0Dent Res Dent Clin Dent Prospects 13(2):85\u201389. https:\/\/doi.org\/10.15171\/joddd.2019.013","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"issue":"6","key":"508_CR40","first-page":"839","volume":"17","author":"H Simon","year":"2002","unstructured":"Simon\u00a0H, Caputo\u00a0AA (2002) Removal torque of immediately loaded transitional endosseous implants in human subjects. Int J Oral Maxillofac Implants 17(6):839\u2013845","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"6","key":"508_CR41","doi-asserted-by":"publisher","first-page":"979","DOI":"10.2319\/090606-363.1","volume":"77","author":"Y-Y Song","year":"2007","unstructured":"Song\u00a0Y\u2011Y, Cha\u00a0J\u2011Y, Hwang\u00a0C\u2011J (2007) Mechanical characteristics of various orthodontic mini-screws in relation to artificial cortical bone thickness. Angle Orthod 77(6):979\u2013985. https:\/\/doi.org\/10.2319\/090606-363.1","journal-title":"Angle Orthod"},{"issue":"5","key":"508_CR42","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1016\/j.ajodo.2010.11.017","volume":"139","author":"EY Suzuki","year":"2011","unstructured":"Suzuki\u00a0EY, Suzuki\u00a0B (2011) Placement and removal torque values of orthodontic miniscrew implants. Am J Orthod Dentofacial Orthop 139(5):669\u2013678. https:\/\/doi.org\/10.1016\/j.ajodo.2010.11.017","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"2","key":"508_CR43","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1016\/j.kjms.2016.11.001","volume":"33","author":"Y-C Tseng","year":"2017","unstructured":"Tseng\u00a0Y\u2011C, Wu\u00a0J\u2011H, Ting\u00a0C\u2011C et\u00a0al (2017) Evaluation of mechanical strengths of three types of mini-implants in artificial bones. Kaohsiung J Med Sci 33(2):96\u2013101. https:\/\/doi.org\/10.1016\/j.kjms.2016.11.001","journal-title":"Kaohsiung J Med Sci"},{"issue":"2","key":"508_CR44","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1002\/(SICI)1097-4636(199602)30:2","volume":"30","author":"A Wennerberg","year":"1996","unstructured":"Wennerberg\u00a0A, Albrektsson\u00a0T, Lausmaa\u00a0J (1996) Torque and histomorphometric evaluation of c.\u202fp. titanium screws blasted with 25- and 75-microns-sized particles of Al2O3. J\u00a0Biomed Mater Res 30(2):251\u2013260. https:\/\/doi.org\/10.1002\/(SICI)1097-4636(199602)30:2","journal-title":"J Biomed Mater Res"},{"issue":"1","key":"508_CR45","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1007\/s00056-008-0727-4","volume":"69","author":"B Wilmes","year":"2008","unstructured":"Wilmes\u00a0B, Ottenstreuer\u00a0S, Su\u00a0Y\u2011Y et\u00a0al (2008) Impact of implant design on primary stability of orthodontic mini-implants. J\u00a0Orofac Orthop 69(1):42\u201350. https:\/\/doi.org\/10.1007\/s00056-008-0727-4","journal-title":"J Orofac Orthop"},{"issue":"3","key":"508_CR46","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1007\/s00056-006-0611-z","volume":"67","author":"B Wilmes","year":"2006","unstructured":"Wilmes\u00a0B, Rademacher\u00a0C, Olthoff\u00a0G et\u00a0al (2006) Parameters affecting primary stability of orthodontic mini-implants. J\u00a0Orofac Orthop 67(3):162\u2013174. https:\/\/doi.org\/10.1007\/s00056-006-0611-z","journal-title":"J Orofac Orthop"},{"issue":"8","key":"508_CR47","doi-asserted-by":"publisher","first-page":"1595","DOI":"10.1016\/j.joms.2009.04.015","volume":"67","author":"T-Y Wu","year":"2009","unstructured":"Wu\u00a0T\u2011Y, Kuang\u00a0S\u2011H, Wu\u00a0C\u2011H (2009) Factors associated with the stability of mini-implants for orthodontic anchorage: a\u00a0study of 414 samples in Taiwan. J\u00a0Oral Maxillofac Surg 67(8):1595\u20131599. https:\/\/doi.org\/10.1016\/j.joms.2009.04.015","journal-title":"J Oral Maxillofac Surg"}],"container-title":["Journal of Orofacial Orthopedics \/ Fortschritte der Kieferorthop\u00e4die"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00056-023-00508-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00056-023-00508-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00056-023-00508-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,6]],"date-time":"2025-05-06T04:31:14Z","timestamp":1746505874000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00056-023-00508-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,15]]},"references-count":47,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["508"],"URL":"https:\/\/doi.org\/10.1007\/s00056-023-00508-9","relation":{},"ISSN":["1434-5293","1615-6714"],"issn-type":[{"value":"1434-5293","type":"print"},{"value":"1615-6714","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,15]]},"assertion":[{"value":"17 April 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 October 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 January 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"C.\u00a0Prinz is an employee of the company DOT GmbH. K.\u00a0Duske, B.\u00a0Turan, J.H.\u00a0Lenz, F.\u00a0Stahl and M.\u00a0Warkentin declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study was performed in accordance with the national guidelines. It was approved by the State Office for Agriculture, Food Safety and Fisheries of the federal state of Mecklenburg-Pomerania (Rostock, Germany, number 7221.3\u20111.1\u2011106\/12). It was in accordance with the Animal Research: Reporting of In Vivo Experiments (ARRIVE) guidelines for animal research.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical standards"}}]}}