{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T03:42:20Z","timestamp":1740109340888,"version":"3.37.3"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2018,9,6]],"date-time":"2018-09-06T00:00:00Z","timestamp":1536192000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2018,9,6]],"date-time":"2018-09-06T00:00:00Z","timestamp":1536192000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Herz"],"published-print":{"date-parts":[[2020,6]]},"DOI":"10.1007\/s00059-018-4738-7","type":"journal-article","created":{"date-parts":[[2018,9,6]],"date-time":"2018-09-06T07:34:21Z","timestamp":1536219261000},"page":"369-374","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Optical coherence tomography-verified longer balloon inflation time may provide better stent apposition and optimal index parameters","Mittels optischer Koh\u00e4renztomographie \u00fcberpr\u00fcfte l\u00e4ngere Balloninsufflationszeit k\u00f6nnte eine bessere Stentapposition und optimale Indexparameter erm\u00f6glichen"],"prefix":"10.1007","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2030-3810","authenticated-orcid":false,"given":"O.","family":"Tasar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A. K.","family":"Karabay","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C. Y\u00fccel","family":"Karabay","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Kalkan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Cinier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I. H.","family":"Tanboga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A. I.","family":"Izgi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"K\u0131rma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,9,6]]},"reference":[{"key":"4738_CR1","doi-asserted-by":"publisher","first-page":"1428","DOI":"10.1016\/S0735-1097(97)00334-3","volume":"30","author":"A Kastrati","year":"1997","unstructured":"Kastrati A, Sch\u00f6mig A, Elezi S, Sch\u00fchlen H, Dirschinger J, Hadamitzky M, Wehinger A, Hausleiter J, Walter H, Neumann F\u2011J (1997) Predictive factors of restenosis after coronary stent placement. J\u00a0Am Coll Cardiol 30:1428\u20131436","journal-title":"J Am Coll Cardiol"},{"key":"4738_CR2","doi-asserted-by":"publisher","first-page":"1630","DOI":"10.1016\/S0735-1097(98)00404-5","volume":"32","author":"S Kasaoka","year":"1998","unstructured":"Kasaoka S, Tobis JM, Akiyama T, Reimers B, Di Mario C, Wong ND, Colombo A (1998) Angiographic and intravascular ultrasound predictors of in-stent restenosis. J\u00a0Am Coll Cardiol 32:1630\u20131635","journal-title":"J Am Coll Cardiol"},{"key":"4738_CR3","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1002\/ccd.24724","volume":"83","author":"JR Cook","year":"2014","unstructured":"Cook JR, Mhatre A, Wang FW, Uretsky BF (2014) Prolonged high-pressure is required for optimal stent deployment as assessed by optical coherence tomography. Catheter Cardiovasc Interv 83:521\u2013527","journal-title":"Catheter Cardiovasc Interv"},{"key":"4738_CR4","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1016\/j.amjcard.2004.06.029","volume":"94","author":"DJ Blackman","year":"2004","unstructured":"Blackman DJ, Porto I, Shirodaria C, Channon KM, Banning AP (2004) Usefulness of high-pressure post-dilatation to optimize deployment of drug-eluting stents for the treatment of diffuse in-stent coronary restenosis. Am J Cardiol 94:922\u2013925","journal-title":"Am J Cardiol"},{"key":"4738_CR5","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1002\/ccd.20350","volume":"65","author":"E Cheneau","year":"2005","unstructured":"Cheneau E, Satler LF, Escolar E, Suddath WO, Kent KM, Weissman NJ, Waksman R, Pichard AD (2005) Underexpansion of sirolimus-eluting stents: Incidence and relationship to delivery pressure. Catheter Cardiovasc Interv 65:222\u2013226","journal-title":"Catheter Cardiovasc Interv"},{"key":"4738_CR6","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1016\/j.carrev.2006.09.002","volume":"7","author":"A Javaid","year":"2006","unstructured":"Javaid A, Chu WW, Cheneau E, Clavijo LC, Satler LF, Kent KM, Weissman NJ, Pichard AD, Waksman R (2006) Comparison of paclitaxel-eluting stent and sirolimus-eluting stent expansion at incremental delivery pressures. Cardiovasc Revasc Med 7:208\u2013211","journal-title":"Cardiovasc Revasc Med"},{"key":"4738_CR7","doi-asserted-by":"publisher","first-page":"1913","DOI":"10.1136\/hrt.2009.172072","volume":"95","author":"N Gonzalo","year":"2009","unstructured":"Gonzalo N, Serruys PW, Okamura T, Shen ZJ, Onuma Y, Garcia-Garcia HM, Sarno G, Schultz C, van Geuns RJ, Ligthart J (2009) Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a\u00a0systematic quantitative approach. Heart 95:1913\u20131919","journal-title":"Heart"},{"key":"4738_CR8","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1016\/j.jjcc.2011.12.003","volume":"59","author":"Y Iwamoto","year":"2012","unstructured":"Iwamoto Y, Okamoto M, Hashimoto M, Fukuda Y, Iwamoto A, Iwasaki T, Kinoshita H, Kihara Y (2012) Better stent expansion by two-time inflation of stent balloon and its responsible mechanism. J\u00a0Cardiol 59:160\u2013166","journal-title":"J Cardiol"},{"key":"4738_CR9","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1111\/joic.12096","volume":"27","author":"SH Ann","year":"2014","unstructured":"Ann SH, Chung JW, De Jin C, Lee JH, Kim JM, Garg S, Sh\u0131n ES (2014) Better Inflation Time of Stent Balloon for Second-Generation Drug-Eluting Stent Expansion and Apposition: An Optical Coherence Tomography Study. J\u00a0Interv Cardiol 27:171\u2013176","journal-title":"J Interv Cardiol"},{"key":"4738_CR10","first-page":"396","volume":"20","author":"IS Trindade","year":"2008","unstructured":"Trindade IS, Sarmento-Leite R, de Freitas SM, Gottschall C (2008) Determination of the minimum inflation time necessary for total stent expansion and apposition: an in vitro study. J\u00a0Invasive Cardiol 20:396\u2013398","journal-title":"J Invasive Cardiol"},{"key":"4738_CR11","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1002\/ccd.23343","volume":"81","author":"T Hovasse","year":"2013","unstructured":"Hovasse T, Mylotte D, Garot P, Salvatella N, Morice MC, Chevalier B, Pichard A, Lef\u00e8vre T (2013) Duration of balloon inflation for optimal stent deployment: Five Seconds Is Not Enough. Catheter Cardiovasc Interv 81:446\u2013453","journal-title":"Catheter Cardiovasc Interv"},{"key":"4738_CR12","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1161\/01.CIR.0000121327.67756.19","volume":"109","author":"K Fujii","year":"2004","unstructured":"Fujii K, Mintz GS, Kobayashi Y, Carlier SG, Takebayashi H, Yasuda T, Moussa I, Dangas G, Mehran R, Lansky AJ (2004) Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis. Circulation 109:1085\u20131088","journal-title":"Circulation"},{"key":"4738_CR13","doi-asserted-by":"publisher","first-page":"1959","DOI":"10.1016\/j.jacc.2004.01.044","volume":"43","author":"S Sonoda","year":"2004","unstructured":"Sonoda S, Morino Y, Ako J, Terashima M, Hassan AH, Bonneau HN, Leon MB, Moses JW, Yock PG, Honda Y (2004) Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation. J\u00a0Am Coll Cardiol 43:1959\u20131963","journal-title":"J Am Coll Cardiol"},{"key":"4738_CR14","volume-title":"CIRCINTERVENTIONS. 108.778647","author":"RJ Russo","year":"2009","unstructured":"Russo RJ, Silva PD, Teirstein PS, Attubato MJ, Davidson CJ, DeFranco AC, Fitzgerald PJ, Goldberg SL, Hermiller JB, Leon MB. A randomized controlled trial of angiography versus intravascular ultrasound-directed bare-metal coronary stent placement (the AVID Trial). Circ Cardiovasc Interv (2009) CIRCINTERVENTIONS. 108.778647"},{"key":"4738_CR15","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1016\/j.ahj.2007.06.017","volume":"154","author":"RJ Gil","year":"2007","unstructured":"Gil RJ, Paw\u0142owski T, Dudek D, Horszczaruk G, \u017bmudka K, Lesiak M, Witkowski A, Ocha\u0142a A, Kubica J, Trial IoDSvOA. (2007) Comparison of angiographically guided direct stenting technique with direct stenting and optimal balloon angioplasty guided with intravascular ultrasound. The multicenter, randomized trial results. Am Heart\u00a0J 154:669\u2013675","journal-title":"Am Heart J"},{"key":"4738_CR16","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1002\/ccd.21813","volume":"73","author":"T Kawasaki","year":"2009","unstructured":"Kawasaki T, Koga H, Serikawa T, Orita Y, Ikeda S, Mito T, Gotou Y, Shintani Y, Tanaka A, Tanaka H (2009) Impact of a\u00a0prolonged delivery inflation time for optimal drug-eluting stent expansion. Catheter Cardiovasc Interv 73:205\u2013211","journal-title":"Catheter Cardiovasc Interv"},{"key":"4738_CR17","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1007\/s00380-008-1130-1","volume":"24","author":"T Asano","year":"2009","unstructured":"Asano T, Kobayashi Y, Fukushima K, Iwata Y, Kitahara H, Ishio N, Nakayama T, Kuroda N, Komuro I (2009) Effect of balloon inflation time on expansion of sirolimus-eluting stent. Heart Vessels 24:335\u2013339","journal-title":"Heart Vessels"},{"issue":"5","key":"4738_CR18","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1007\/s00059-011-3487-7","volume":"36","author":"E Regar","year":"2011","unstructured":"Regar E, Ligthart J, Bruining N, van Soest G (2011) The diagnostic value of intracoronary optical coherence tomography. Herz 36(5):417\u2013429 (Aug)","journal-title":"Herz"}],"container-title":["Herz"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00059-018-4738-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00059-018-4738-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00059-018-4738-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,10]],"date-time":"2020-06-10T14:32:26Z","timestamp":1591799546000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00059-018-4738-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,6]]},"references-count":18,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020,6]]}},"alternative-id":["4738"],"URL":"https:\/\/doi.org\/10.1007\/s00059-018-4738-7","relation":{},"ISSN":["0340-9937","1615-6692"],"issn-type":[{"type":"print","value":"0340-9937"},{"type":"electronic","value":"1615-6692"}],"subject":[],"published":{"date-parts":[[2018,9,6]]},"assertion":[{"value":"27 May 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2018","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 July 2018","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 September 2018","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical guidelines"}},{"value":"O.\u00a0Tasar, A.K.\u00a0Karabay, C.Y.\u00a0Karabay, S.\u00a0Kalkan, G.\u00a0Cinier, I.H.\u00a0Tanboga, A.I.\u00a0Izgi and C.\u00a0K\u0131rma declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}