{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T14:31:18Z","timestamp":1788877878722,"version":"build-2803163510"},"reference-count":10,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2022,5,5]],"date-time":"2022-05-05T00:00:00Z","timestamp":1651708800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,5,5]],"date-time":"2022-05-05T00:00:00Z","timestamp":1651708800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001652","name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100001652","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin Neuroradiol"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Artifacts from surrounding bony structures, especially from the petrous bones, regularly impair soft tissue computed tomography (CT) imaging of the middle and posterior fossa. This affects flat-panel CT in particular. Sinusoidal movement of the C\u2011arm during acquisition (i.e. craniocaudal tilting along with semicircular rotation) is supposed to reduce artifacts, thus enhancing soft tissue imaging quality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      In the work-up of ischemic stroke or subarachnoid hemorrhage 40\u00a0patients underwent multi-slice CT (MS-CT) and either plain circular (cFP-CT;\n                      <jats:italic>n<\/jats:italic>\n                      \u202f=\u200920) or sinusoidal (sFP-CT;\n                      <jats:italic>n<\/jats:italic>\n                      \u202f=\u200920) flat-panel CT within a\u00a0short interval. Two independent readers analyzed MS-CT and FP-CT datasets for recognizability of eight different brain structures and three typical types of artifacts according to a\u00a0predetermined score.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Interrater reliability was moderate for cFP-CT (\u03ba\u202f=\u20090.575) and good to very good for ratings of MS-CT and sFP-CT (\u03ba\u202f=\u20090.651 to \u03ba\u202f=\u20091). MS-CT was rated to be significantly better than cFP-CT and sFP-CT (\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&lt;\u20090.0001) in the overall score. Yet, sFP-CT was rated to be significantly superior to cFP-CT (overall\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&lt;\u20090.0001) regarding most anatomical regions and petrous bone artifacts.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Compared to a\u00a0standard circular protocol, sinusoidal C\u2011arm movement in cranial FP-CT can significantly reduce artifacts in the posterior fossa and, moreover, can improve visualization of most supratentorial and infratentorial anatomical structures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00062-022-01172-z","type":"journal-article","created":{"date-parts":[[2022,5,5]],"date-time":"2022-05-05T16:08:02Z","timestamp":1651766882000},"page":"1109-1115","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Change your Angle of View"],"prefix":"10.1007","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3935-0003","authenticated-orcid":false,"given":"Hannes","family":"Luecking","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip","family":"Hoelter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Lang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"Eisenhut","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arnd","family":"Doerfler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,5,5]]},"reference":[{"key":"1172_CR1","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1055\/s-0031-1281821","volume":"183","author":"KA Hausegger","year":"2011","unstructured":"Hausegger KA, F\u00fcrstner M, Hauser M, Smetana F, Kau T. Klinische Anwendung der Flachdetektor-CT im Angio-OP [Clinical application of flat-panel CT in the angio suite]. Rofo. 2011;183:1116-22.","journal-title":"Rofo"},{"key":"1172_CR2","first-page":"330","volume":"27","author":"NS Heran","year":"2006","unstructured":"Heran NS, Song JK, Namba K, Smith W, Niimi Y, Berenstein A. The utility of DynaCT in neuroendovascular procedures. AJNR Am J Neuroradiol. 2006;27:330-2.","journal-title":"AJNR Am J Neuroradiol"},{"key":"1172_CR3","first-page":"052115","volume":"8","author":"R Fahrig","year":"2021","unstructured":"Fahrig R, Jaffray DA, Sechopoulos I, Webster Stayman J. Flat-panel conebeam CT in the clinic: history and current state. J Med Imaging (Bellingham). 2021;8:052115.","journal-title":"J Med Imaging (Bellingham)"},{"key":"1172_CR4","doi-asserted-by":"publisher","first-page":"901","DOI":"10.3171\/2010.2.JNS091054","volume":"113","author":"T Struffert","year":"2010","unstructured":"Struffert T, Eyupoglu IY, Huttner HB, Engelhorn T, Doelken M, Saake M, Ganslandt O, Doerfler A. Clinical evaluation of flat-panel detector compared with multislice computed tomography in 65 patients with acute intracranial hemorrhage: initial results. Clinical article. J Neurosurg. 2010;113:901-7.","journal-title":"J Neurosurg."},{"issue":"Suppl 2","key":"1172_CR5","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1007\/s00062-015-0423-x","volume":"25","author":"A Doerfler","year":"2015","unstructured":"Doerfler A, G\u00f6litz P, Engelhorn T, Kloska S, Struffert T. Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute Stroke. Clin Neuroradiol. 2015;25 Suppl 2:291-7.","journal-title":"Clin Neuroradiol."},{"key":"1172_CR6","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1177\/1747493019895655","volume":"16","author":"M Bouslama","year":"2021","unstructured":"Bouslama M, Haussen DC, Grossberg JA, Barreira CM, Bom IMJV, Nijnatten FV, Gr\u00fcnhagen T, Moyer L, Frankel MR, Nogueira RG. Flat-panel detector CT assessment in stroke to reduce times to intra-arterial treatment: A study of multiphase computed tomography angiography in the angiography suite to bypass conventional imaging. Int J Stroke. 2021;16:63-72.","journal-title":"Int J Stroke"},{"key":"1172_CR7","doi-asserted-by":"publisher","first-page":"2630","DOI":"10.1161\/STROKEAHA.120.029905","volume":"51","author":"JAR Pfaff","year":"2020","unstructured":"Pfaff JAR, Sch\u00f6nenberger S, Herweh C, Ulfert C, Nagel S, Ringleb PA, Bendszus M, M\u00f6hlenbruch MA. Direct Transfer to Angio-Suite Versus Computed Tomography-Transit in Patients Receiving Mechanical Thrombectomy: A Randomized Trial. Stroke. 2020;51:2630-8. Erratum in: Stroke. 2020;51:e346.","journal-title":"Stroke"},{"key":"1172_CR8","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1007\/s00117-015-2815-y","volume":"55","author":"T Struffert","year":"2015","unstructured":"Struffert T, Lang S, Scholz R, Hauer M, D\u00f6rfler A. Strahlendosis bei zerebraler Angiographie und Flachdetektor-CT-Applikationen in der Neuroradiologie [Radiation dose in cerebral angiography and flat detector CT applications in neuroradiology]. Radiologe. 2015;55:654-62.","journal-title":"Radiologe"},{"key":"1172_CR9","doi-asserted-by":"publisher","first-page":"1930","DOI":"10.3174\/ajnr.A1237","volume":"29","author":"Y Kyriakou","year":"2008","unstructured":"Kyriakou Y, Richter G, D\u00f6rfler A, Kalender WA. Neuroradiologic applications with routine C-arm flat panel detector CT: evaluation of patient dose measurements. AJNR Am J Neuroradiol. 2008;29:1930-6.","journal-title":"AJNR Am J Neuroradiol"},{"key":"1172_CR10","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1007\/s00330-014-3136-7","volume":"24","author":"T Struffert","year":"2014","unstructured":"Struffert T, Hauer M, Banckwitz R, K\u00f6hler C, Royalty K, Doerfler A. Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology. Eur Radiol. 2014;24:1257-65.","journal-title":"Eur Radiol"}],"container-title":["Clinical Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00062-022-01172-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00062-022-01172-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00062-022-01172-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,12]],"date-time":"2022-12-12T03:08:24Z","timestamp":1670814504000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00062-022-01172-z"}},"subtitle":["Sinusoidal C-Arm Movement in Cranial Flat-panel CT to Improve Image Quality"],"short-title":[],"issued":{"date-parts":[[2022,5,5]]},"references-count":10,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["1172"],"URL":"https:\/\/doi.org\/10.1007\/s00062-022-01172-z","relation":{},"ISSN":["1869-1439","1869-1447"],"issn-type":[{"value":"1869-1439","type":"print"},{"value":"1869-1447","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,5]]},"assertion":[{"value":"31 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 May 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"H.\u00a0Luecking, P.\u00a0Hoelter, S.\u00a0Lang, M.\u00a0Schmidt, F.\u00a0Eisenhut and A.\u00a0Doerfler declare that they have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}