{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,15]],"date-time":"2025-11-15T00:05:14Z","timestamp":1763165114127},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2012,2,1]],"date-time":"2012-02-01T00:00:00Z","timestamp":1328054400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Oper Orthop Traumatol"],"published-print":{"date-parts":[[2012,2]]},"DOI":"10.1007\/s00064-011-0098-7","type":"journal-article","created":{"date-parts":[[2012,2,1]],"date-time":"2012-02-01T11:02:02Z","timestamp":1328094122000},"page":"4-12","source":"Crossref","is-referenced-by-count":20,"title":["Die Behandlung osteoporotischer Wirbelk\u00f6rperfrakturen mit augmentierter Instrumentation"],"prefix":"10.1007","volume":"24","author":[{"given":"D.","family":"Krappinger","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.J.","family":"Kastenberger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Schmid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2012,2,3]]},"reference":[{"key":"98_CR1","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1007\/s001320050401","volume":"28","author":"Bastian","year":"1999","unstructured":"Bastian L, Knop C, Lange U et al (1999) Effect of a crosslink or cerclage on the mechanical stability of an internal fixator. Orthopade 28:714\u2013722","journal-title":"Orthopade"},{"key":"98_CR2","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1007\/s00586-008-0769-8","volume":"17","author":"Becker","year":"2008","unstructured":"Becker S, Chavanne A, Spitaler R et al (2008) Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J 17:1462\u20131469","journal-title":"Eur Spine J"},{"key":"98_CR3","doi-asserted-by":"crossref","unstructured":"Blauth M, Knop C, Bastian L (1998) Brust- und Lendenwirbels\u00e4ule. Tscherne Unfallchirurgie \u2013 Wirbels\u00e4ule Springer, S\u00a0241\u2013372","DOI":"10.1007\/978-3-642-58840-2_4"},{"key":"98_CR4","doi-asserted-by":"crossref","first-page":"E932","DOI":"10.1097\/BRS.0b013e3181c6ec60","volume":"35","author":"Bullmann","year":"2010","unstructured":"Bullmann V, Schmoelz W, Richter M et al (2010) Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers. Spine 35:E932\u2013939","journal-title":"Spine"},{"key":"98_CR5","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1097\/01.brs.0000261566.38422.40","volume":"32","author":"Burval","year":"2007","unstructured":"Burval DJ, Mclain RF, Milks R et al (2007) Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Spine 32:1077\u20131083","journal-title":"Spine"},{"key":"98_CR6","doi-asserted-by":"crossref","unstructured":"Castro WH, Halm H, Jerosch J et al (1996) Accuracy of pedicle screw placement in lumbar vertebrae. Spine (Phila Pa 1976) 21:1320\u20131324","DOI":"10.1097\/00007632-199606010-00008"},{"key":"98_CR7","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1097\/BSD.0b013e3181981843","volume":"23","author":"Chen","year":"2010","unstructured":"Chen WJ, Kao YH, Yang SC et al (2010) Impact of cement leakage into disks on the development of adjacent vertebral compression fractures. J Spinal Disord Tech 23:35\u201339","journal-title":"J Spinal Disord Tech"},{"key":"98_CR8","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1097\/BSD.0b013e3181f605d0","volume":"24","author":"Cho","year":"2010","unstructured":"Cho W, Wu C, Zheng X et al (2010) Is it safe to back out pedicle screws after augmentation with polymethyl methacrylate or calcium phosphate cement? A biomechanical study. J Spinal Disord Tech 24(4):276\u2013279","journal-title":"J Spinal Disord Tech"},{"key":"98_CR9","doi-asserted-by":"crossref","unstructured":"Choma TJ, Frevert WF, Carson WI et al (2010) Biomechanical analysis of pedicle screws in osteoporotic bone with bioactive cement augmentation using simulated in vivo multicomponent loading. Spine","DOI":"10.1097\/BRS.0b013e3181d449ec"},{"key":"98_CR10","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1227\/01.NEU.0000290899.15567.68","volume":"61","author":"Frankel","year":"2007","unstructured":"Frankel BM, Jones T, Wang C (2007) Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery 61:531\u2013537, (discussion 537\u2013538)","journal-title":"Neurosurgery"},{"key":"98_CR11","doi-asserted-by":"crossref","unstructured":"George DC, Krag MH, Johnson CC et al (1991) Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae. Spine (Phila Pa 1976) 16:181\u2013184","DOI":"10.1097\/00007632-199116020-00015"},{"key":"98_CR12","doi-asserted-by":"crossref","unstructured":"Hirano T, Hasegawa K, Takahashi HE et al (1997) Structural characteristics of the pedicle and its role in screw stability. Spine (Phila Pa 1976) 22:2504\u20132509, (discussion 2510)","DOI":"10.1097\/00007632-199711010-00007"},{"key":"98_CR13","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1056\/NEJMoa0900563","volume":"361","author":"Kallmes","year":"2009","unstructured":"Kallmes DF, Comstock BA, Heagerty PJ et al (2009) A randomized trial of vertebroplasty for osteoporotic spinal fractures. N Engl J Med 361:569\u2013579","journal-title":"N Engl J Med"},{"key":"98_CR14","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s00064-005-1132-4","volume":"17","author":"Knop","year":"2005","unstructured":"Knop C, Lange U, Reinhold M et al (2005) Vertebral body replacement with Synex in combined posteroanterior surgery for treatment of thoracolumbar injuries. Oper Orthop Traumatol 17:249\u2013280","journal-title":"Oper Orthop Traumatol"},{"key":"98_CR15","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1007\/s00586-009-1073-y","volume":"18","author":"Krueger","year":"2009","unstructured":"Krueger A, Bliemel C, Zettl R et al (2009) Management of pulmonary cement embolism after percutaneous vertebroplasty and kyphoplasty: a systematic review of the literature. Eur Spine J 18:1257\u20131265","journal-title":"Eur Spine J"},{"key":"98_CR16","first-page":"1","volume":"J","author":"Kr\u00fcger","year":"2010","unstructured":"Kr\u00fcger A, Zettl R, Ziring E et al (2010) Kyphoplasty for the treatment of incomplete osteoporotic burst fractures. Eur Spine J:1\u20138","journal-title":"Eur Spine"},{"key":"98_CR17","doi-asserted-by":"crossref","unstructured":"Lee BJ, Lee SR, Yoo TY (2002) Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: a case report. Spine (Phila Pa 1976) 27:E419\u2013422","DOI":"10.1097\/00007632-200210010-00022"},{"key":"98_CR18","first-page":"175","volume":"25","author":"Lin","year":"2004","unstructured":"Lin EP, Ekholm S, Hiwatashi A et al (2004) Vertebroplasty: cement leakage into the disc increases the risk of new fracture of adjacent vertebral body. AJNR Am J Neuroradiol 25:175\u2013180","journal-title":"AJNR Am J Neuroradiol"},{"key":"98_CR19","doi-asserted-by":"crossref","first-page":"305","DOI":"10.3340\/jkns.2009.46.4.305","volume":"46","author":"Moon","year":"2009","unstructured":"Moon BJ, Cho BY, Choi EY et al (2009) Polymethylmethacrylate-augmented screw fixation for stabilization of the osteoporotic spine: a three-year follow-up of 37\u00a0patients. J Korean Neurosurg Soc 46:305\u2013311","journal-title":"J Korean Neurosurg Soc"},{"key":"98_CR20","doi-asserted-by":"crossref","first-page":"E212","DOI":"10.1097\/00007632-200406010-00020","volume":"29","author":"Renner","year":"2004","unstructured":"Renner SM, Lim T-H, Kim WJ et al (2004) Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine 29:E212\u2013216","journal-title":"Spine"},{"key":"98_CR21","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1097\/01.brs.0000253645.24141.21","volume":"32","author":"Tan","year":"2007","unstructured":"Tan JS, Bailey CS, Dvorak MF et al (2007) Cement augmentation of vertebral screws enhances the interface strength between interbody device and vertebral body. Spine 32:334\u2013341","journal-title":"Spine"},{"key":"98_CR22","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1016\/S0140-6736(09)60010-6","volume":"373","author":"Wardlaw","year":"2009","unstructured":"Wardlaw D, Cummings SR, Van Meirhaeghe J et al (2009) Efficacy and safety of balloon kyphoplasty compared with non-surgical care for vertebral compression fracture (FREE): a randomised controlled trial. Lancet 373:1016\u20131024","journal-title":"Lancet"},{"key":"98_CR23","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.injury.2009.09.033","volume":"41","author":"Zou","year":"2010","unstructured":"Zou J, Mei X, Gan M et al (2010) Is kyphoplasty reliable for osteoporotic vertebral compression fracture with vertebral wall deficiency? Injury 41:360\u2013364","journal-title":"Injury"}],"container-title":["Operative Orthop\u00e4die und Traumatologie"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00064-011-0098-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00064-011-0098-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00064-011-0098-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,23]],"date-time":"2019-06-23T00:05:40Z","timestamp":1561248340000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00064-011-0098-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,2]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2012,2]]}},"alternative-id":["98"],"URL":"https:\/\/doi.org\/10.1007\/s00064-011-0098-7","relation":{},"ISSN":["0934-6694","1439-0981"],"issn-type":[{"value":"0934-6694","type":"print"},{"value":"1439-0981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,2]]}}}