{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T06:46:16Z","timestamp":1794465976012,"version":"4.9.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,11,18]],"date-time":"2024-11-18T00:00:00Z","timestamp":1731888000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,11,18]],"date-time":"2024-11-18T00:00:00Z","timestamp":1731888000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Oper Orthop Traumatol"],"published-print":{"date-parts":[[2025,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>Presentation and description of percutaneous sacroiliac (SI) screw fixation with the use of a\u00a03D robot-assisted image-guided navigation system and the clinical outcome of this technique.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Indications<\/jats:title>\n            <jats:p>Pelvic fractures involving the posterior pelvis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Contraindications<\/jats:title>\n            <jats:p>Patients not suited for surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Surgical technique<\/jats:title>\n            <jats:p>Planning the screws on the diagnostic computer tomogram (CT). Matching with a\u00a0low-dose CT in the operating room. Lateral incision. Verify the guidewire position with the personalized inlet and outlet views. After correct positioning, place a\u00a0cannulated screw over the guidewire. For fragility fractures, augmentation is recommended. Finish the surgery with a\u00a0final 3D scan to confirm correct placement of the screws and cement.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Postoperative management<\/jats:title>\n            <jats:p>Direct postoperative mobilization with pain-adapted full weight-bearing.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Data of 141 patients between January 2018 and August 2022 were analyzed (average age\u00a082\u202f\u00b1\u200910\u00a0years, 89% female). Most of the fractures were type\u00a0II fragility fractures of the pelvis (FFP; 75%). The median hospital stay was 12\u202f\u00b1\u20097\u00a0days and the median surgery duration for a unilateral SI screw was 26\u202fmin. In total 221 S1\u00a0screws and 17\u00a0S2 screws were applied. No screws showed signs of loosening or migration. Of the five suboptimally placed screws, one screw was removed due to sensory impairment. All patients with cement leakage remained without symptoms.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The surgical technique with the use of a\u00a03D robot-assisted image-guided navigation system is a technique for safe fixation of dorsal fragility fractures of the pelvis and is associated with fewer complications.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s00064-024-00871-9","type":"journal-article","created":{"date-parts":[[2024,11,18]],"date-time":"2024-11-18T12:04:45Z","timestamp":1731931485000},"page":"3-13","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Percutaneous sacroiliac screw fixation with a\u00a03D robot-assisted image-guided navigation system","Perkutane sakroiliakale Schraubenfixation mit einem robotergest\u00fctzten bildgesteuerten 3D-Navigationssystem"],"prefix":"10.1007","volume":"37","author":[{"given":"Bj\u00f6rn-Christian","family":"Link","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. A.","family":"Haveman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B. J. M.","family":"Van de Wall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Baumg\u00e4rtner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Babst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F. J. P.","family":"Beeres","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. C.","family":"Haefeli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,11,18]]},"reference":[{"issue":"2","key":"871_CR1","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/s10195-012-0182-2","volume":"13","author":"M Alnaib","year":"2012","unstructured":"Alnaib\u00a0M, Waters\u00a0S, Shanshal\u00a0Y, Caplan\u00a0N, Jones\u00a0S, St Clair Gibson\u00a0A et\u00a0al (2012) Combined pubic rami and sacral osteoporotic fractures: a\u00a0prospective study. J\u00a0Orthop Traumatol 13(2):97\u2013103","journal-title":"J Orthop Traumatol"},{"issue":"6","key":"871_CR2","doi-asserted-by":"publisher","first-page":"4713","DOI":"10.1007\/s00068-022-01989-w","volume":"48","author":"G Beelen","year":"2022","unstructured":"Beelen\u00a0G, Loggers\u00a0SAI, de Wit\u00a0BWK, Schakenraad\u00a0D, Hofstee\u00a0DJ, Joosse\u00a0P et\u00a0al (2022) Additional clinical value of routine CT imaging in fragility fractures of the pelvis: a\u00a0prospective cohort study (ARTIFACT). Eur J Trauma Emerg Surg 48(6):4713\u20134718","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"1","key":"871_CR3","first-page":"309","volume":"18","author":"G Ciolli","year":"2021","unstructured":"Ciolli\u00a0G, Caviglia\u00a0D, Vitiello\u00a0C, Lucchesi\u00a0S, Pinelli\u00a0C, De Mauro\u00a0D et\u00a0al (2021) Navigated percutaneous screw fixation of the pelvis with O\u2011arm 2: two years\u2019 experience. Med Glas 18(1):309\u2013315","journal-title":"Med Glas"},{"key":"871_CR4","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1097\/BOT.0000000000000602","volume":"30","author":"CA Collinge","year":"2016","unstructured":"Collinge\u00a0CA, Crist\u00a0BD (2016) Combined percutaneous iliosacral screw fixation with sacroplasty using resorbable calcium phosphate cement for osteoporotic pelvic fractures requiring surgery. J\u00a0Orthop Trauma 30:217\u2013222","journal-title":"J Orthop Trauma"},{"issue":"4","key":"871_CR5","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1016\/j.rbo.2013.04.002","volume":"48","author":"HA Cruz","year":"2013","unstructured":"Cruz\u00a0HA, Angelis\u00a0GP (2013) Sacroiliac secure corridor: analysis for safe insertion of iliosacral screws. Rev Bras Ortop 48(4):348\u2013356","journal-title":"Rev Bras Ortop"},{"issue":"12","key":"871_CR6","doi-asserted-by":"publisher","first-page":"1710","DOI":"10.1016\/j.injury.2013.04.030","volume":"44","author":"I El-Daly","year":"2013","unstructured":"El-Daly\u00a0I, Reidy\u00a0J, Culpan\u00a0P, Bates\u00a0P (2013) Thromboprophylaxis in patients with pelvic and acetabular fractures: a\u00a0short review and recommendations. Injury 44(12):1710\u20131720","journal-title":"Injury"},{"issue":"5","key":"871_CR7","doi-asserted-by":"publisher","first-page":"3729","DOI":"10.1007\/s00068-021-01660-w","volume":"48","author":"L Gericke","year":"2022","unstructured":"Gericke\u00a0L, Fritz\u00a0A, Osterhoff\u00a0G, Josten\u00a0C, Pieroh\u00a0P, Hoch\u00a0A (2022) Percutaneous operative treatment of fragility fractures of the pelvis may not increase the general rate of complications compared to non-operative treatment. Eur J Trauma Emerg Surg 48(5):3729\u20133735","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"12","key":"871_CR8","doi-asserted-by":"publisher","first-page":"4062","DOI":"10.1016\/j.injury.2022.09.050","volume":"53","author":"RA Haveman","year":"2022","unstructured":"Haveman\u00a0RA, Baumlein\u00a0M, van Veelen\u00a0N, Oberkircher\u00a0L, Beeres\u00a0FJP, Babst\u00a0R et\u00a0al (2022) Percutaneous sacroiliac screw fixation in fragility fractures of the pelvis: comparison of two different augmentation techniques. Injury 53(12):4062\u20134066","journal-title":"Injury"},{"key":"871_CR9","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1055\/s-0044-100157","volume":"34","author":"H Keil","year":"2018","unstructured":"Keil\u00a0H, Gr\u00fctzner\u00a0PA, Franke\u00a0J (2018) Bildgebung in der Beckenchirurgie. OP-JOURNAL 34:5\u201316","journal-title":"OP-JOURNAL"},{"key":"871_CR10","doi-asserted-by":"crossref","unstructured":"Kress H, Klein R, Pohlemann T, Wolfl CG (2022) Sacroiliac screw placement with ease: CT-guided pelvic fracture Osteosynthesis in the elderly. Medicina 58(6)","DOI":"10.3390\/medicina58060809"},{"issue":"1","key":"871_CR11","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1007\/s00068-020-01439-5","volume":"47","author":"HH Lee","year":"2021","unstructured":"Lee\u00a0HH, Kim\u00a0WY, Lim\u00a0YW, Byun\u00a0YS, Lee\u00a0SW (2021) Is there a\u00a0correlation between fragility fractures of the pelvis (FFP) and the morphology of the true pelvis in geriatric patients? Eur J Trauma Emerg Surg 47(1):3\u201310","journal-title":"Eur J Trauma Emerg Surg"},{"key":"871_CR12","doi-asserted-by":"publisher","first-page":"656","DOI":"10.5435\/00124635-200611000-00009","volume":"14","author":"S Mehta","year":"2006","unstructured":"Mehta\u00a0S, Auerbach\u00a0JD, Born\u00a0CT, Chin\u00a0KR (2006) Sacral fractures. J\u00a0Am Acad Orthop Surg 14:656\u2013665","journal-title":"J Am Acad Orthop Surg"},{"issue":"11","key":"871_CR13","doi-asserted-by":"publisher","first-page":"2522","DOI":"10.1007\/s11999-016-4934-9","volume":"474","author":"G Osterhoff","year":"2016","unstructured":"Osterhoff\u00a0G, Dodd\u00a0AE, Unno\u00a0F, Wong\u00a0A, Amiri\u00a0S, Lefaivre\u00a0KA et\u00a0al (2016) Cement augmentation in sacroiliac screw fixation offers Modest biomechanical advantages in a\u00a0cadaver model. Clin Orthop Relat Res 474(11):2522\u20132530","journal-title":"Clin Orthop Relat Res"},{"key":"871_CR14","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/S0002-9378(15)33150-1","volume":"27","author":"T Pohlemann","year":"1996","unstructured":"Pohlemann\u00a0T, G\u00e4nsslen\u00a0A, Schellwald\u00a0O, Culemann\u00a0U, Tscherne\u00a0H (1996) Outcome after pelvic ring injuries. Injury 27:31\u201338","journal-title":"Injury"},{"issue":"2","key":"871_CR15","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1016\/j.injury.2015.11.023","volume":"47","author":"PH Richter","year":"2016","unstructured":"Richter\u00a0PH, Gebhard\u00a0F, Dehner\u00a0C, Scola\u00a0A (2016) Accuracy of computer-assisted iliosacral screw placement using a\u00a0hybrid operating room. Injury 47(2):402\u2013407","journal-title":"Injury"},{"issue":"12","key":"871_CR16","doi-asserted-by":"publisher","first-page":"1733","DOI":"10.1016\/j.injury.2013.06.023","volume":"44","author":"PM Rommens","year":"2013","unstructured":"Rommens\u00a0PM, Hofmann\u00a0A (2013) Comprehensive classification of fragility fractures of the pelvic ring: Recommendations for surgical treatment. Injury 44(12):1733\u20131744","journal-title":"Injury"},{"issue":"4","key":"871_CR17","doi-asserted-by":"publisher","first-page":"2881","DOI":"10.1007\/s00068-021-01799-6","volume":"48","author":"PM Rommens","year":"2022","unstructured":"Rommens\u00a0PM, Hofmann\u00a0A, Kraemer\u00a0S, Kisilak\u00a0M, Boudissa\u00a0M, Wagner\u00a0D (2022) Operative treatment of fragility fractures of the pelvis: a\u00a0critical analysis of 140 patients. Eur J Trauma Emerg Surg 48(4):2881\u20132896","journal-title":"Eur J Trauma Emerg Surg"},{"key":"871_CR18","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1097\/00005131-199711000-00007","volume":"11","author":"ML Routt","year":"1997","unstructured":"Routt\u00a0ML, Simonian\u00a0PT, Mills\u00a0WJ (1997) Iliosacral screw fixation: early complications of the percutaneous technique. J\u00a0Orthop Trauma 11:584\u2013589","journal-title":"J Orthop Trauma"},{"issue":"1","key":"871_CR19","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1097\/BOT.0b013e31802ea951","volume":"21","author":"W Smith","year":"2007","unstructured":"Smith\u00a0W, Williams\u00a0A, Agudelo\u00a0J, Shannon\u00a0M, Morgan\u00a0S, Stahel\u00a0P et\u00a0al (2007) Early predictors of mortality in hemodynamically unstable pelvis fractures. J\u00a0Orthop Trauma 21(1):31\u201337","journal-title":"J Orthop Trauma"},{"issue":"1","key":"871_CR20","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1007\/s11548-016-1465-5","volume":"12","author":"SC Thakkar","year":"2017","unstructured":"Thakkar\u00a0SC, Thakkar\u00a0RS, Sirisreetreerux\u00a0N, Carrino\u00a0JA, Shafiq\u00a0B, Hasenboehler\u00a0EA (2017) 2D versus 3D fluoroscopy-based navigation in posterior pelvic fixation: review of the literature on current technology. Int J Comput Assist Radiol Surg 12(1):69\u201376","journal-title":"Int J Comput Assist Radiol Surg"}],"container-title":["Operative Orthop\u00e4die und Traumatologie"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00064-024-00871-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00064-024-00871-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00064-024-00871-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,3]],"date-time":"2025-02-03T08:34:07Z","timestamp":1738571647000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00064-024-00871-9"}},"subtitle":["Technical solutions","Technische L\u00f6sungen"],"short-title":[],"issued":{"date-parts":[[2024,11,18]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,2]]}},"alternative-id":["871"],"URL":"https:\/\/doi.org\/10.1007\/s00064-024-00871-9","relation":{},"ISSN":["0934-6694","1439-0981"],"issn-type":[{"value":"0934-6694","type":"print"},{"value":"1439-0981","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,18]]},"assertion":[{"value":"2 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 May 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 June 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 November 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"B.-C.\u00a0Link is a consultant for Siemens. R.A.\u00a0Haveman, B.\u00a0Van de Wall, R.\u00a0Baumg\u00e4rtner, R.\u00a0Babst, F.J.P.\u00a0Beeres and P.\u00a0Haefeli declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"For this article no studies with human participants or animals were performed by any of the authors. All studies mentioned were in accordance with the ethical standards indicated in each case.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}