{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T09:50:22Z","timestamp":1683107422154},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2009,11,16]],"date-time":"2009-11-16T00:00:00Z","timestamp":1258329600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur J Trauma"],"published-print":{"date-parts":[[2009,12]]},"DOI":"10.1007\/s00068-009-9176-z","type":"journal-article","created":{"date-parts":[[2009,11,16]],"date-time":"2009-11-16T03:52:27Z","timestamp":1258343547000},"page":"513-519","source":"Crossref","is-referenced-by-count":4,"title":["Treatment of Distal Lower Leg Fractures: Results with Fixed-Angle Plate Osteosynthesis"],"prefix":"10.1007","volume":"35","author":[{"given":"Maximilian","family":"Faschingbauer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benjamin","family":"Kienast","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arndt P.","family":"Schulz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rudolf","family":"Vukelic","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Meiners","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2009,11,16]]},"reference":[{"key":"9176_CR1","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1007\/s00402-007-0343-6","volume":"127","author":"H. Namazi","year":"2007","unstructured":"Namazi H, Mozaffarian K. Awful considerations with LCP instrumentation: a new pitfall. Arch Orthop Trauma Surg 2007;127:573\u2013575.","journal-title":"Arch Orthop Trauma Surg"},{"key":"9176_CR2","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1016\/j.injury.2003.08.015","volume":"35","author":"T. Borg","year":"2004","unstructured":"Borg T, Larsson S, Lindsj\u00f6 U. Percutaneous plating of distal tibial fractures. Preliminary results in 21 patients. Injury 2004;35:608\u2013614.","journal-title":"Injury"},{"key":"9176_CR3","doi-asserted-by":"crossref","first-page":"A42","DOI":"10.1016\/S0020-1383(97)90114-5","volume":"28","author":"D.L. Helfet","year":"1997","unstructured":"Helfet DL, Shonnard PY, Levine D, Borrelli J Jr. Minimally invasive plate osteosynthesis of distal fractures of the tibia. Injury 1997;28:A42\u2013A48.","journal-title":"Injury"},{"key":"9176_CR4","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1177\/107110070202300908","volume":"23","author":"A. Khoury","year":"2002","unstructured":"Khoury A, Liebergall M, London E, Mosheiff R. Percutaneous plating of distal tibial fractures. Foot Ankle Int 2002;23:818\u2013824.","journal-title":"Foot Ankle Int"},{"key":"9176_CR5","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1007\/s00402-004-0778-y","volume":"125","author":"T. Krackhardt","year":"2005","unstructured":"Krackhardt T, Dilger J, Flesch I, H\u00f6ntzsch D, Eingartner C, Weise K. Fractures of the distal tibia treated with closed reduction and minimally invasive plating. Arch Orthop Trauma Surg 2005;125:87\u201394.","journal-title":"Arch Orthop Trauma Surg"},{"key":"9176_CR6","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1007\/s00264-004-0541-6","volume":"28","author":"N. Maffulli","year":"2004","unstructured":"Maffulli N, Toms AD, McMurtie A, Oliva F. Percutaneous plating of distal tibial fractures. Int Orthop 2004;28:159\u2013162.","journal-title":"Int Orthop"},{"key":"9176_CR7","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1097\/00003086-200303000-00038","volume":"408","author":"C.W. Oh","year":"2003","unstructured":"Oh CW, Kyung HS, Park IH, Kim PT, Ihn JC. Distal tibia metaphyseal fractures treated by percutaneous plate osteosynthesis. Clin Orthop Relat Res 2003;408:286\u2013291.","journal-title":"Clin Orthop Relat Res"},{"key":"9176_CR8","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1016\/j.injury.2003.09.005","volume":"35","author":"D.J. Redfern","year":"2004","unstructured":"Redfern DJ, Syed SU, Davies SJ. Fractures of the distal tibia: minimally invasive plate osteosynthesis. Injury 2004;35:615\u2013620.","journal-title":"Injury"},{"key":"9176_CR9","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1097\/BOT.0b013e3180ca83c7","volume":"21","author":"C. Collinge","year":"2007","unstructured":"Collinge C, Kuper M, Larson K, Protzman R. Minimally invasive plating of high-energy metaphyseal distal tibia fractures. J Orthop Trauma 2007;21:355\u2013361.","journal-title":"J Orthop Trauma"},{"key":"9176_CR10","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1016\/j.injury.2006.06.002","volume":"37","author":"S. Hazarika","year":"2006","unstructured":"Hazarika S, Chakravarthy J, Cooper J. Minimally invasive locking plate osteosynthesis for fractures of the distal tibia \u2014 results in 20 patients. Injury 2006;37:877\u2013887.","journal-title":"Injury"},{"key":"9176_CR11","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1007\/s11999-008-0459-1","volume":"467","author":"H. Gao","year":"2009","unstructured":"Gao H, Zhang CQ, Luo CF, Zhou ZB, Zeng BF. Fractures of the distal tibia treated with polyaxial locking plating. Clin Orthop Relat Res 2009;467:831\u2013837.","journal-title":"Clin Orthop Relat Res"},{"key":"9176_CR12","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1007\/s00264-007-0384-z","volume":"32","author":"T.W. Lau","year":"2008","unstructured":"Lau TW, Leung F, Chan CF, Chow SP. Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures. Int Orthop 2008;32:697\u2013703.","journal-title":"Int Orthop"},{"key":"9176_CR13","first-page":"163","volume":"32","author":"Y.S. Lee","year":"2009","unstructured":"Lee YS, Chen SH, Lin JC, Chen YO, Huang CR, Cheng CY. Surgical treatment of distal tibia fractures: a comparison of medial and lateral plating. Orthopedics 2009;32:163.","journal-title":"Orthopedics"},{"key":"9176_CR14","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1007\/s00402-006-0278-3","volume":"127","author":"M.J. Manninen","year":"2007","unstructured":"Manninen MJ, Lindahl J, Kankare J, Hirvensalo E. Lateral approach for fixation of the fractures of the distal tibia. Outcome of 20 patients. Technical note. Arch Orthop Trauma Surg 2007;127:349\u2013353.","journal-title":"Arch Orthop Trauma Surg"},{"key":"9176_CR15","first-page":"45","volume":"51","author":"P.M. Morin","year":"2008","unstructured":"Morin PM, Reindl R, Harvey EJ, Beckman L, Steffen T. Fibular fixation as an adjuvant to tibial intramedullary nailing in the treatment of combined distal third tibia and fibula fractures: a biomechanical investigation. Can J Surg 2008;51:45\u201350.","journal-title":"Can J Surg"},{"key":"9176_CR16","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1097\/01.bot.0000199118.61229.70","volume":"20","author":"K.A. Egol","year":"2006","unstructured":"Egol KA, Weisz R, Hiebert R, Tejwani NC, Koval KJ, Sanders RW. Does fibular plating improve alignment after intramedullary nailing of distal metaphyseal tibia fractures? J Orthop Trauma 2006;20:94\u2013103.","journal-title":"J Orthop Trauma"},{"key":"9176_CR17","doi-asserted-by":"crossref","first-page":"604","DOI":"10.2106\/00004623-200304000-00003","volume":"85","author":"A. Kumar","year":"2003","unstructured":"Kumar A, Charlebois SJ, Cain EL, Smith RA, Daniels AU, Crates JM. Effect of fibular plate fixation on rotational stability of simulated distal tibial fractures treated with intramedullary nailing. J Bone Joint Surg Am 2003;85:604\u2013608.","journal-title":"J Bone Joint Surg Am"},{"key":"9176_CR18","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1097\/BOT.0b013e31816ed974","volume":"22","author":"H.A. Vallier","year":"2008","unstructured":"Vallier HA, Le TT, Bedi A. Radiographic and clinical comparisons of distal tibia shaft fractures (4 to 11 cm proximal to the plafond): plating versus intramedullary nailing. J Orthop Trauma 2008;22:307\u2013311.","journal-title":"J Orthop Trauma"},{"key":"9176_CR19","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1007\/s00264-006-0237-1","volume":"31","author":"K.W. Janssen","year":"2007","unstructured":"Janssen KW, Biert J, van Kampen A. Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients. Int Orthop 2007;31:709\u2013714.","journal-title":"Int Orthop"},{"key":"9176_CR20","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1097\/00005131-200211000-00002","volume":"16","author":"J. Borrelli Jr","year":"2002","unstructured":"Borrelli J Jr, Prickett W, Song E, Becker D, Ricci W. Extraosseous blood supply of the tibia and the effects of different plating techniques: a human cadaveric study. J Orthop Trauma 2002;16:691\u2013695.","journal-title":"J Orthop Trauma"},{"key":"9176_CR21","unstructured":"Vallier HA, Toan Le T, Bedi A, Srinivas R, Moore M. A comparison of plate versus intramedullary nail fixation for distal tibia fractures. Paper presented at: Annual Meeting of the Orthopaedic Trauma Association, 20\u201322 October 2005, Ottawa, Ontario, Canada."},{"key":"9176_CR22","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1097\/01.bot.0000202997.45274.a1","volume":"20","author":"B.A. Zelle","year":"2006","unstructured":"Zelle BA, Bhandari M, Espiritu M, Koval KJ, Zlowodzki M. Treatment of distal tibia fractures without articular involvement: a systematic review of 1125 fractures. J Orthop Trauma 2006;20:76\u201379.","journal-title":"J Orthop Trauma"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-009-9176-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00068-009-9176-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-009-9176-z","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,22]],"date-time":"2019-05-22T22:31:13Z","timestamp":1558564273000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00068-009-9176-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,11,16]]},"references-count":22,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["9176"],"URL":"https:\/\/doi.org\/10.1007\/s00068-009-9176-z","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,11,16]]}}}