{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,5,23]],"date-time":"2024-05-23T10:38:29Z","timestamp":1716460709537},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2011,1,19]],"date-time":"2011-01-19T00:00:00Z","timestamp":1295395200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"published-print":{"date-parts":[[2011,4]]},"DOI":"10.1007\/s00068-010-0069-y","type":"journal-article","created":{"date-parts":[[2011,1,18]],"date-time":"2011-01-18T07:25:03Z","timestamp":1295335503000},"page":"121-126","source":"Crossref","is-referenced-by-count":3,"title":["Accuracy of CT-assisted pedicle screw placement after CT-controlled, presurgical guide wire implantation in traumatic and pathological fractures in the thoracic spine"],"prefix":"10.1007","volume":"37","author":[{"given":"C.","family":"Ploss","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Maier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. G.","family":"Mack","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I.","family":"Marzi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2011,1,19]]},"reference":[{"key":"69_CR1","doi-asserted-by":"crossref","first-page":"591","DOI":"10.2106\/00004623-196244040-00001","volume":"44-A","author":"PR Harrington","year":"1962","unstructured":"Harrington PR. Treatment of scoliosis. Correction and internal fixation by spine instrumentation. J Bone Joint Surg Am. 1962;44-A:591\u2013610.","journal-title":"J Bone Joint Surg Am"},{"key":"69_CR2","doi-asserted-by":"crossref","unstructured":"Moe JH. Modern concepts of treatment of spinal deformities in children and adults. Clin Orthop Relat Res. 1980;(150):137\u201353.","DOI":"10.1097\/00003086-198007000-00024"},{"key":"69_CR3","first-page":"2","volume":"15","author":"R Roy-Camille","year":"1976","unstructured":"Roy-Camille R, Saillant G, Berteaux D, Salgado V. Osteosynthesis of thoraco-lumbar spine fractures with metal plates screwed through the vertebral pedicles. Reconstr Surg Traumatol. 1976;15:2\u201316.","journal-title":"Reconstr Surg Traumatol"},{"key":"69_CR4","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1097\/00007632-198711000-00009","volume":"12","author":"W Dick","year":"1987","unstructured":"Dick W. The \u201cfixateur interne\u201d as a versatile implant for spine surgery. Spine. 1987;12:882\u2013900.","journal-title":"Spine"},{"key":"69_CR5","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1002\/ca.20155","volume":"18","author":"AG Christodoulou","year":"2005","unstructured":"Christodoulou AG, Apostolou T, Ploumis A, Terzidis I, Hantzokos I, Pournaras J. Pedicle dimensions of the thoracic and lumbar vertebrae in the Greek population. Clin Anat. 2005;18:404\u20138.","journal-title":"Clin Anat"},{"key":"69_CR6","doi-asserted-by":"crossref","first-page":"2467","DOI":"10.1097\/00007632-200211150-00009","volume":"27","author":"RF McLain","year":"2002","unstructured":"McLain RF, Ferrara L, Kabins M. Pedicle morphometry in the upper thoracic spine: limits to safe screw placement in older patients. Spine. 2002;27:2467\u201371.","journal-title":"Spine"},{"key":"69_CR7","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/00007632-199602010-00002","volume":"21","author":"R Kothe","year":"1996","unstructured":"Kothe R, O\u2019Holleran JD, Liu W, Panjabi MM. Internal architecture of the thoracic pedicle. An anatomic study. Spine. 1996;21:264\u201370.","journal-title":"Spine"},{"key":"69_CR8","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1007\/s001320050367","volume":"28","author":"H Graichen","year":"1999","unstructured":"Graichen H, Putz R. Anatomical and functional aspects of the thoracic and lumbar spine. Orthopade. 1999;28:424\u201331.","journal-title":"Orthopade"},{"key":"69_CR9","doi-asserted-by":"crossref","first-page":"1076","DOI":"10.1007\/s001130170023","volume":"104","author":"M Arand","year":"2001","unstructured":"Arand M, Hartwig E, Hebold D, Kinzl L, Gebhard F. Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study. Unfallchirurg. 2001;104:1076\u201381.","journal-title":"Unfallchirurg"},{"key":"69_CR10","doi-asserted-by":"crossref","first-page":"2340","DOI":"10.1097\/00007632-200111010-00010","volume":"26","author":"PJ Belmont Jr","year":"2001","unstructured":"Belmont PJ Jr, Klemme WR, Dhawan A, Polly DW Jr. In vivo accuracy of thoracic pedicle screws. Spine. 2001;26:2340\u20136.","journal-title":"Spine"},{"key":"69_CR11","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/00007632-199001000-00004","volume":"15","author":"SD Gertzbein","year":"1990","unstructured":"Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine. 1990;15:11\u20134.","journal-title":"Spine"},{"key":"69_CR12","doi-asserted-by":"crossref","first-page":"E326","DOI":"10.1097\/01.brs.0000166621.98354.1d","volume":"30","author":"RA Hart","year":"2005","unstructured":"Hart RA, Hansen BL, Shea M, Hsu F, Anderson GJ. Pedicle screw placement in the thoracic spine: a comparison of image-guided and manual techniques in cadavers. Spine. 2005;30:E326\u201331.","journal-title":"Spine"},{"key":"69_CR13","doi-asserted-by":"crossref","first-page":"2324","DOI":"10.1097\/01.BRS.0000085361.32600.63","volume":"28","author":"DS Husted","year":"2003","unstructured":"Husted DS, Yue JJ, Fairchild TA, Haims AH. An extrapedicular approach to the placement of screws in the thoracic spine: an anatomic and radiographic assessment. Spine. 2003;28:2324\u201330.","journal-title":"Spine"},{"key":"69_CR14","doi-asserted-by":"crossref","first-page":"E355","DOI":"10.1097\/01.brs.0000219394.48091.d6","volume":"31","author":"KK White","year":"2006","unstructured":"White KK, Oka R, Mahar AT, Lowry A, Garfin SR. Pullout strength of thoracic pedicle screw instrumentation: comparison of the transpedicular and extrapedicular techniques. Spine. 2006;31:E355\u20138.","journal-title":"Spine"},{"key":"69_CR15","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1097\/00007632-199901150-00003","volume":"24","author":"G Cinotti","year":"1999","unstructured":"Cinotti G, Gumina S, Ripani M, Postacchini F. Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine. 1999;24:114\u20139.","journal-title":"Spine"},{"key":"69_CR16","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.2106\/00004623-199508000-00008","volume":"77","author":"AR Vaccaro","year":"1995","unstructured":"Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA, Cotler JM. Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am. 1995;77:1193\u20139.","journal-title":"J Bone Joint Surg Am"},{"key":"69_CR17","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1097\/00007632-199805010-00021","volume":"23","author":"R Xu","year":"1998","unstructured":"Xu R, Ebraheim NA, Ou Y, Yeasting RA. Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique. Spine. 1998;23:1065\u20138.","journal-title":"Spine"},{"key":"69_CR18","doi-asserted-by":"crossref","first-page":"1399","DOI":"10.1097\/00007632-199506020-00012","volume":"20","author":"SI Suk","year":"1995","unstructured":"Suk SI, Lee CK, Kim WJ, Chung YJ, Park YB. Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine. 1995;20:1399\u2013405.","journal-title":"Spine"},{"key":"69_CR19","doi-asserted-by":"crossref","first-page":"2049","DOI":"10.1097\/00007632-200109150-00022","volume":"26","author":"SI Suk","year":"2001","unstructured":"Suk SI, Kim WJ, Lee SM, Kim JH, Chung ER. Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine. 2001;26:2049\u201357.","journal-title":"Spine"},{"key":"69_CR20","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1097\/00007632-200102150-00011","volume":"26","author":"KD Kim","year":"2001","unstructured":"Kim KD, Patrick Johnson J, Bloch BS O, Masciopinto JE. Computer-assisted thoracic pedicle screw placement: an in vitro feasibility study. Spine. 2001;26:360\u20134.","journal-title":"Spine"},{"key":"69_CR21","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1097\/01.BRS.0000109983.12113.9B","volume":"29","author":"YJ Kim","year":"2004","unstructured":"Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD. Free hand pedicle screw placement in the thoracic spine: is it safe? Spine. 2004;29:333\u201342.","journal-title":"Spine"},{"key":"69_CR22","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1097\/00007632-199606010-00008","volume":"21","author":"WH Castro","year":"1996","unstructured":"Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S. Accuracy of pedicle screw placement in lumbar vertebrae. Spine. 1996;21:1320\u20134.","journal-title":"Spine"},{"key":"69_CR23","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1097\/00007632-199702010-00001","volume":"22","author":"NA Ebraheim","year":"1997","unstructured":"Ebraheim NA, Xu R, Ahmad M, Yeasting RA. Projection of the thoracic pedicle and its morphometric analysis. Spine. 1997;22:233\u20138.","journal-title":"Spine"},{"key":"69_CR24","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1007\/BF01676570","volume":"6","author":"MM Panjabi","year":"1997","unstructured":"Panjabi MM, O\u2019Holleran JD, Crisco JJ III, Kothe R. Complexity of the thoracic spine pedicle anatomy. Eur Spine J. 1997;6:19\u201324.","journal-title":"Eur Spine J"},{"issue":"6","key":"69_CR25","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/S0090-3019(97)00296-6","volume":"48","author":"SA Shapiro","year":"1997","unstructured":"Shapiro SA, Snyder W. Spinal instrumentation with a low complication rate. Surg Neurol. 1997;48(6):566\u201374.","journal-title":"Surg Neurol"},{"key":"69_CR26","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1038\/sc.1969.30","volume":"7","author":"HL Frankel","year":"1969","unstructured":"Frankel HL, Hancock DO, Hyslop G, Melzak J, Michaelis LS, Ungar GH, Vernon JD, Walsh JJ. The value of postural reduction in the initial management of closed injuries of the spine with paraplegia and tetraplegia. I. Paraplegia. 1969;7:179\u201392.","journal-title":"Paraplegia"},{"key":"69_CR27","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1038\/sc.1991.85","volume":"29","author":"RL Waters","year":"1991","unstructured":"Waters RL, Adkins RH, Yakura JS. Definition of complete spinal cord injury. Paraplegia. 1991;29:573\u201381.","journal-title":"Paraplegia"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-010-0069-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00068-010-0069-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-010-0069-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,7]],"date-time":"2019-06-07T19:20:57Z","timestamp":1559935257000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00068-010-0069-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1,19]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2011,4]]}},"alternative-id":["69"],"URL":"https:\/\/doi.org\/10.1007\/s00068-010-0069-y","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,1,19]]}}}