{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T10:25:27Z","timestamp":1778840727636,"version":"3.51.4"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,9,28]],"date-time":"2018-09-28T00:00:00Z","timestamp":1538092800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1007\/s00068-018-1021-9","type":"journal-article","created":{"date-parts":[[2018,9,28]],"date-time":"2018-09-28T02:57:04Z","timestamp":1538103424000},"page":"187-195","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Comparison of thick- and thin-slice images in thoracoabdominal trauma CT: a retrospective analysis"],"prefix":"10.1007","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5521-5928","authenticated-orcid":false,"given":"Leon","family":"Guchlerner","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julian Lukas","family":"Wichmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patricia","family":"Tischendorf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Moritz","family":"Albrecht","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas Josef","family":"Vogl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Wutzler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hanns","family":"Ackermann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katrin","family":"Eichler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claudia","family":"Frellesen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,9,28]]},"reference":[{"key":"1021_CR1","unstructured":"Robert Koch-Institut Gesundheitsberichterstattung des Bundes: Gemeinsam getragen von RKI und DESTATIS Gesundheit in Deutschland. 2015. http:\/\/www.gbe-bund.de\/pdf\/GESBER2015.pdf . Accessed 17 Nov 2017."},{"issue":"5","key":"1021_CR2","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1007\/s00330-002-1385-3","volume":"12","author":"M Wintermark","year":"2002","unstructured":"Wintermark M, Poletti P-A, Becker CD, et al. Traumatic injuries: Organization and ergonomics of imaging in the emergency environment. Eur Radiol. 2002;12(5):959\u201368. https:\/\/doi.org\/10.1007\/s00330-002-1385-3 .","journal-title":"Eur Radiol"},{"issue":"4","key":"1021_CR3","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1016\/j.rcl.2015.02.006","volume":"53","author":"ML Gunn","year":"2015","unstructured":"Gunn ML, Kool DR, Lehnert BE. (2015) Improving outcomes in the patient with polytrauma: a review of the role of whole-body computed tomography. Radiol Clin N Am 53(4):639\u201356, vii. https:\/\/doi.org\/10.1016\/j.rcl.2015.02.006 .","journal-title":"Radiol Clin N Am"},{"issue":"7","key":"1021_CR4","doi-asserted-by":"publisher","first-page":"1728","DOI":"10.1007\/s00330-001-1225-x","volume":"12","author":"U Linsenmaier","year":"2002","unstructured":"Linsenmaier U, Kr\u00f6tz M, H\u00e4user H, et al. Whole-body computed tomography in polytrauma: techniques and management. Eur Radiol. 2002;12(7):1728\u201340. https:\/\/doi.org\/10.1007\/s00330-001-1225-x .","journal-title":"Eur Radiol"},{"issue":"9673","key":"1021_CR5","doi-asserted-by":"publisher","first-page":"1455","DOI":"10.1016\/S0140-6736(09)60232-4","volume":"373","author":"S Huber-Wagner","year":"2009","unstructured":"Huber-Wagner S, Lefering R, Qvick L-M, et al. Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study. Lancet. 2009;373(9673):1455\u201361. https:\/\/doi.org\/10.1016\/S0140-6736(09)60232-4 .","journal-title":"Lancet"},{"issue":"3","key":"1021_CR6","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1148\/radiol.12120354","volume":"265","author":"JA Soto","year":"2012","unstructured":"Soto JA, Anderson SW. Multidetector CT of blunt abdominal trauma. Radiology. 2012;265(3):678\u201393. https:\/\/doi.org\/10.1148\/radiol.12120354 .","journal-title":"Radiology"},{"issue":"3","key":"1021_CR7","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.ejrad.2007.09.023","volume":"65","author":"M Scaglione","year":"2008","unstructured":"Scaglione M, Pinto A, Pedrosa I, et al. Multi-detector row computed tomography and blunt chest trauma. Eur J Radiol. 2008;65(3):377\u201388. https:\/\/doi.org\/10.1016\/j.ejrad.2007.09.023 .","journal-title":"Eur J Radiol"},{"issue":"1","key":"1021_CR8","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.injury.2006.07.006","volume":"38","author":"M Traub","year":"2007","unstructured":"Traub M, Stevenson M, McEvoy S, et al. The use of chest computed tomography versus chest X-ray in patients with major blunt trauma. Injury. 2007;38(1):43\u20137. https:\/\/doi.org\/10.1016\/j.injury.2006.07.006 .","journal-title":"Injury"},{"issue":"3","key":"1021_CR9","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1148\/radiol.2353040037","volume":"235","author":"TG Flohr","year":"2005","unstructured":"Flohr TG, Schaller S, Stierstorfer K, et al. Multi-detector row CT systems and image-reconstruction techniques. Radiology. 2005;235(3):756\u201373. https:\/\/doi.org\/10.1148\/radiol.2353040037 .","journal-title":"Radiology"},{"issue":"2","key":"1021_CR10","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1007\/s10140-013-1166-0","volume":"21","author":"MM Hammer","year":"2014","unstructured":"Hammer MM, Flagg E, Mellnick VM, et al. Computed tomography of blunt and penetrating diaphragmatic injury: sensitivity and inter-observer agreement of CT signs. Emerg Radiol. 2014;21(2):143\u20139. https:\/\/doi.org\/10.1007\/s10140-013-1166-0 .","journal-title":"Emerg Radiol"},{"key":"1021_CR11","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1186\/1471-227X-8-10","volume":"8","author":"TP Saltzherr","year":"2008","unstructured":"Saltzherr TP, Fung Kon Jin PHP, Bakker FC, et al. An evaluation of a Shockroom located CT scanner: a randomized study of early assessment by CT scanning in trauma patients in the bi-located trauma center North-West Netherlands (REACT trial). BMC Emerg Med. 2008;8:10. https:\/\/doi.org\/10.1186\/1471-227X-8-10 .","journal-title":"BMC Emerg Med"},{"issue":"2","key":"1021_CR12","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1016\/j.injury.2004.07.027","volume":"36","author":"PJ Richards","year":"2005","unstructured":"Richards PJ. (2005) Cervical spine clearance: a review. Injury 36(2):248\u201369. https:\/\/doi.org\/10.1016\/j.injury.2004.07.027 (discussion 270).","journal-title":"Injury"},{"issue":"8","key":"1021_CR13","doi-asserted-by":"publisher","first-page":"1446","DOI":"10.3174\/ajnr.A1152","volume":"29","author":"PM Phal","year":"2008","unstructured":"Phal PM, Riccelli LP, Wang P, et al. Fracture detection in the cervical spine with multidetector CT: 1-mm versus 3-mm axial images. AJNR Am J Neuroradiol. 2008;29(8):1446\u20139. https:\/\/doi.org\/10.3174\/ajnr.A1152 .","journal-title":"AJNR Am J Neuroradiol"},{"issue":"10","key":"1021_CR14","doi-asserted-by":"publisher","first-page":"1751","DOI":"10.1007\/s00330-004-2424-z","volume":"14","author":"C Herzog","year":"2004","unstructured":"Herzog C, Ahle H, Mack MG, et al. Traumatic injuries of the pelvis and thoracic and lumbar spine: does thin-slice multidetector-row CT increase diagnostic accuracy? Eur Radiol. 2004;14(10):1751\u201360. https:\/\/doi.org\/10.1007\/s00330-004-2424-z .","journal-title":"Eur Radiol"},{"issue":"3","key":"1021_CR15","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1097\/TA.0b013e31822dd93b","volume":"72","author":"R Vugt van","year":"2012","unstructured":"van Vugt R, Kool DR, Deunk J, et al. Effects on mortality, treatment, and time management as a result of routine use of total body computed tomography in blunt high-energy trauma patients. J Trauma Acute Care Surg. 2012;72(3):553\u20139. https:\/\/doi.org\/10.1097\/TA.0b013e31822dd93b .","journal-title":"J Trauma Acute Care Surg"},{"issue":"1","key":"1021_CR16","doi-asserted-by":"publisher","first-page":"70","DOI":"10.6092\/1590-8577\/2901","volume":"16","author":"H Ishioka","year":"2015","unstructured":"Ishioka H, Sata N, Ishiguro Y, et al. Early-phase thin-slice CT in the diagnosis of small insulinomas. JOP. 2015;16(1):70\u20133. https:\/\/doi.org\/10.6092\/1590-8577\/2901 .","journal-title":"JOP"},{"key":"1021_CR17","doi-asserted-by":"publisher","DOI":"10.1155\/2016\/5781790","author":"K Maetani","year":"2016","unstructured":"Maetani K, Namiki J, Matsumoto S, et al. Routine head computed tomography for patients in the emergency room with trauma requires both thick- and thin-slice images. Emerg Med Int. 2016. https:\/\/doi.org\/10.1155\/2016\/5781790 .","journal-title":"Emerg Med Int"},{"issue":"2","key":"1021_CR18","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.wneu.2012.12.033","volume":"79","author":"SL Zuckerman","year":"2013","unstructured":"Zuckerman SL, Mocco J. Use of thin-slice computed tomography in acute ischemic stroke. World Neurosurg. 2013;79(2):213\u20136. https:\/\/doi.org\/10.1016\/j.wneu.2012.12.033 .","journal-title":"World Neurosurg"},{"issue":"12","key":"1021_CR19","doi-asserted-by":"publisher","first-page":"1137","DOI":"10.1016\/j.compbiomed.2009.10.005","volume":"39","author":"A Retico","year":"2009","unstructured":"Retico A, Fantacci ME, Gori I, et al. Pleural nodule identification in low-dose and thin-slice lung computed tomography. Comput Biol Med. 2009;39(12):1137\u201344. https:\/\/doi.org\/10.1016\/j.compbiomed.2009.10.005 .","journal-title":"Comput Biol Med"},{"issue":"1","key":"1021_CR20","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.clinimag.2014.09.011","volume":"39","author":"K Eichler","year":"2015","unstructured":"Eichler K, Marzi I, Wyen H, et al. Multidetector computed tomography (MDCT): simple CT protocol for trauma patient. Clin Imaging. 2015;39(1):110\u20135. https:\/\/doi.org\/10.1016\/j.clinimag.2014.09.011 .","journal-title":"Clin Imaging"},{"issue":"7","key":"1021_CR21","doi-asserted-by":"publisher","first-page":"1725","DOI":"10.1007\/s00330-014-3197-7","volume":"24","author":"C Frellesen","year":"2014","unstructured":"Frellesen C, Stock W, Kerl JM, et al. Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT\u2014a comparison to fixed kV with mAs modulation alone. Eur Radiol. 2014;24(7):1725\u201334. https:\/\/doi.org\/10.1007\/s00330-014-3197-7 .","journal-title":"Eur Radiol"},{"issue":"5","key":"1021_CR22","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1007\/s10140-007-0651-8","volume":"14","author":"GP Sangster","year":"2007","unstructured":"Sangster GP, Gonz\u00e1lez-Beicos A, Carbo AI, et al. Blunt traumatic injuries of the lung parenchyma, pleura, thoracic wall, and intrathoracic airways: multidetector computer tomography imaging findings. Emerg Radiol. 2007;14(5):297\u2013310. https:\/\/doi.org\/10.1007\/s10140-007-0651-8 .","journal-title":"Emerg Radiol"},{"issue":"2","key":"1021_CR23","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/S0720-048X(00)00270-9","volume":"36","author":"GD Rubin","year":"2000","unstructured":"Rubin GD. Data explosion: the challenge of multidetector-row CT. Eur J Radiol. 2000;36(2):74\u201380.","journal-title":"Eur J Radiol"},{"issue":"3","key":"1021_CR24","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.crad.2009.10.009","volume":"65","author":"G Soo","year":"2010","unstructured":"Soo G, Lau KK, Yik T, et al. Optimal reconstructed section thickness for the detection of liver lesions with multidetector CT. Clin Radiol. 2010;65(3):193\u20137. https:\/\/doi.org\/10.1016\/j.crad.2009.10.009 .","journal-title":"Clin Radiol"},{"issue":"9","key":"1021_CR25","doi-asserted-by":"publisher","first-page":"1881","DOI":"10.1007\/s00330-005-2741-x","volume":"15","author":"A Abdelmoumene","year":"2005","unstructured":"Abdelmoumene A, Chevallier P, Chalaron M, et al. Detection of liver metastases under 2 cm: comparison of different acquisition protocols in four row multidetector-CT (MDCT). Eur Radiol. 2005;15(9):1881\u20137. https:\/\/doi.org\/10.1007\/s00330-005-2741-x .","journal-title":"Eur Radiol"},{"issue":"4","key":"1021_CR26","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1177\/000313481007600414","volume":"76","author":"DS Plurad","year":"2010","unstructured":"Plurad DS, Nielsen JS, Hancock J, et al. Concomitant rib fractures and minor liver or spleen injuries in blunt trauma: what is the potential for missed diaphragmatic injuries? Am Surg. 2010;76(4):380\u20134.","journal-title":"Am Surg"},{"key":"1021_CR27","doi-asserted-by":"publisher","DOI":"10.1080\/09638288.2017.1358771","author":"J Claydon","year":"2017","unstructured":"Claydon J, Maniatopoulos G, Robinson L, et al. Challenges experienced during rehabilitation after traumatic multiple rib fractures: a qualitative study. Disabil Rehabil. 2017. https:\/\/doi.org\/10.1080\/09638288.2017.1358771 .","journal-title":"Disabil Rehabil"},{"issue":"3","key":"1021_CR28","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1136\/emj.2002.004176","volume":"21","author":"CU Dussa","year":"2004","unstructured":"Dussa CU, Soni BM. A hidden injury. Emerg Med J. 2004;21(3):390\u20131.","journal-title":"Emerg Med J"},{"issue":"3","key":"1021_CR29","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1097\/00002517-199109000-00001","volume":"4","author":"H J\u00f3nsson","year":"1991","unstructured":"J\u00f3nsson H, Bring G, Rauschning W, et al. Hidden cervical spine injuries in traffic accident victims with skull fractures. J Spinal Disord. 1991;4(3):251\u201363.","journal-title":"J Spinal Disord"},{"key":"1021_CR30","unstructured":"Deutsche Gesellschaft f\u00fcr Unfallchirurgie AWMF Kurzversion der S3\u2014Leitlinie Polytrauma\/Schwerverletzten\u2014Behandlung. http:\/\/www.awmf.org\/uploads\/tx_szleitlinien\/012-019k_S3_Polytrauma_Schwerverletzten-Behandlung_2017-03.pdf . Accessed 15 Nov 2017."},{"issue":"1","key":"1021_CR31","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1002\/acm2.12005","volume":"18","author":"P Monnin","year":"2017","unstructured":"Monnin P, Sfameni N, Gianoli A, et al. Optimal slice thickness for object detection with longitudinal partial volume effects in computed tomography. J Appl Clin Med Phys. 2017;18(1):251\u20139. https:\/\/doi.org\/10.1002\/acm2.12005 .","journal-title":"J Appl Clin Med Phys"},{"issue":"10","key":"1021_CR32","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1007\/s00113-009-1606-1","volume":"112","author":"V Bogner","year":"2009","unstructured":"Bogner V, Mutschler W, Biberthaler P. Der Faktor \u201cZeit\u201d. Seine Bedeutung in der Pathophysiologie und Therapie des Polytraumas (The \u201ctime\u201d factor. Its impact in pathophysiology and therapy of multiple trauma). Unfallchirurg. 2009;112(10):838\u201345. https:\/\/doi.org\/10.1007\/s00113-009-1606-1 .","journal-title":"Unfallchirurg"},{"issue":"2","key":"1021_CR33","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1148\/radiol.2332040563","volume":"233","author":"D Gur","year":"2004","unstructured":"Gur D. Imaging technology and practice assessments: diagnostic performance, clinical relevance, and generalizability in a changing environment. Radiology. 2004;233(2):309\u201312. https:\/\/doi.org\/10.1148\/radiol.2332040563 .","journal-title":"Radiology"},{"issue":"1","key":"1021_CR34","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.acra.2006.10.003","volume":"14","author":"D Gur","year":"2007","unstructured":"Gur D, Bandos AI, Fuhrman CR, et al. The prevalence effect in a laboratory environment: changing the confidence ratings. Acad Radiol. 2007;14(1):49\u201353. https:\/\/doi.org\/10.1016\/j.acra.2006.10.003 .","journal-title":"Acad Radiol"},{"issue":"6","key":"1021_CR35","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1016\/j.acra.2007.02.016","volume":"14","author":"KS Berbaum","year":"2007","unstructured":"Berbaum KS, El-Khoury GY, Ohashi K, et al. Satisfaction of search in multitrauma patients: severity of detected fractures. Acad Radiol. 2007;14(6):711\u201322. https:\/\/doi.org\/10.1016\/j.acra.2007.02.016 .","journal-title":"Acad Radiol"},{"issue":"1","key":"1021_CR36","doi-asserted-by":"publisher","first-page":"252","DOI":"10.2214\/ajr.177.1.1770252c","volume":"177","author":"KS Berbaum","year":"2001","unstructured":"Berbaum KS. Satisfaction of search in osteoradiology. AJR Am J Roentgenol. 2001;177(1):252\u20133. https:\/\/doi.org\/10.2214\/ajr.177.1.1770252c .","journal-title":"AJR Am J Roentgenol"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-018-1021-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00068-018-1021-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-018-1021-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,11]],"date-time":"2020-11-11T06:59:05Z","timestamp":1605077945000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00068-018-1021-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,28]]},"references-count":36,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["1021"],"URL":"https:\/\/doi.org\/10.1007\/s00068-018-1021-9","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,28]]},"assertion":[{"value":"1 May 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 September 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 September 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Julian L. Wichmann received speakers\u2019 fees from GE Healthcare and Siemens Healthcare. Moritz H. Albrecht received speakers\u2019 fees from Siemens Healthcare. The other authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"For this type of study, formal consent is not required. This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Research involving human participants and\/or animals"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}