{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T02:13:00Z","timestamp":1791943980649,"version":"4.3.4"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,8,31]],"date-time":"2021-08-31T00:00:00Z","timestamp":1630368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,8,31]],"date-time":"2021-08-31T00:00:00Z","timestamp":1630368000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>The aim of this systematic review was to provide an overview of current applications of 3D technologies in surgical management of tibial plateau fractures and to assess whether 3D-assisted surgery results in improved clinical outcome as compared to surgery based on conventional imaging modalities.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A literature search was performed in Pubmed and Embase for articles reporting on the use of 3D techniques in operative management of tibial plateau fractures. This systematic review was performed in concordance with the PRISMA-guidelines. Methodological quality and risk of bias was assessed according to the guidelines of the McMaster Critical Appraisal. Differences in terms of operation time, blood loss, fluoroscopy frequency, intra-operative revision rates and patient-reported outcomes between 3D-assisted and conventional surgery were assessed. Data were pooled using the inverse variance weighting method in RevMan.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Twenty articles evaluating 948 patients treated with 3D-assisted surgery and 126 patients with conventional surgery were included. Five different concepts of 3D-assisted surgery were identified: \u20183D virtual visualization\u2019, \u20183D printed hand-held fracture models\u2019, \u2018Pre-contouring of osteosynthesis plates\u2019, \u20183D printed surgical guides\u2019, and \u2018Intra-operative 3D imaging\u2019. 3D-assisted surgery resulted in reduced operation time (104.7 vs. 126.4\u00a0min; <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01), less blood loss (241\u00a0ml vs. 306\u00a0ml; <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01), decreased frequency of fluoroscopy (5.8 vs. 9.1 times; <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01). No differences in functional outcome was found (Hospital for Special Surgery Knee-Rating Scale: 88.6 vs. 82.8; <jats:italic>P<\/jats:italic>\u2009=\u20090.23).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Five concepts of 3D-assisted surgical management of tibial plateau fractures emerged over the last decade. These include 3D virtual fracture visualization, 3D-printed hand-held fracture models for surgical planning, 3D-printed models for pre-contouring of osteosynthesis plates, 3D-printed surgical guides, and intra-operative 3D imaging. 3D-assisted surgery may have a positive effect on operation time, blood loss, and fluoroscopy frequency.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00068-021-01773-2","type":"journal-article","created":{"date-parts":[[2021,8,31]],"date-time":"2021-08-31T10:02:49Z","timestamp":1630404169000},"page":"1737-1749","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":46,"title":["Does 3D-assisted surgery of tibial plateau fractures improve surgical and patient outcome? A systematic review of 1074 patients"],"prefix":"10.1007","volume":"48","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0034-6816","authenticated-orcid":false,"given":"Nick","family":"Assink","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Inge H. F.","family":"Reininga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaj","family":"ten Duis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Job N.","family":"Doornberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harm","family":"Hoekstra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joep","family":"Kraeima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Max J. H.","family":"Witjes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Paul P. M.","family":"de Vries","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank F. A.","family":"IJpma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,8,31]]},"reference":[{"key":"1773_CR1","doi-asserted-by":"publisher","DOI":"10.1177\/1457496914520854","author":"M Parkkinen","year":"2014","unstructured":"Parkkinen M, Madanat R, Mustonen A, Koskinen SK, Paavola M, Lindahl J. Factors predicting the development of early osteoarthritis following lateral tibial plateau fractures: mid-term clinical and radiographic outcomes of 73 operatively treated patients. Scand J Surg. 2014. https:\/\/doi.org\/10.1177\/1457496914520854.","journal-title":"Scand J Surg"},{"key":"1773_CR2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000000735","author":"B Meulenkamp","year":"2017","unstructured":"Meulenkamp B, Martin R, Desy NM, Duffy P, Korley R, Puloski S, et al. Incidence, risk factors, and location of articular malreductions of the Tibial Plateau. J Orthop Trauma. 2017. https:\/\/doi.org\/10.1097\/BOT.0000000000000735.","journal-title":"J Orthop Trauma"},{"key":"1773_CR3","doi-asserted-by":"publisher","DOI":"10.1007\/s12306-017-0514-8","author":"J Mthethwa","year":"2018","unstructured":"Mthethwa J, Chikate A. A review of the management of Tibial Plateau fractures. Musculoskelet Surg. 2018. https:\/\/doi.org\/10.1007\/s12306-017-0514-8.","journal-title":"Musculoskelet Surg"},{"key":"1773_CR4","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-50887-6","author":"N Assink","year":"2019","unstructured":"Assink N, Kraeima J, Slump CH, ten Duis K, de Vries JPPM, Meesters AML, et al. Quantitative 3D measurements of Tibial Plateau fractures. Sci Rep. 2019. https:\/\/doi.org\/10.1038\/s41598-019-50887-6.","journal-title":"Sci Rep"},{"key":"1773_CR5","doi-asserted-by":"publisher","DOI":"10.1136\/postgradmedj-2019-136482","author":"L Xiong","year":"2019","unstructured":"Xiong L, Li X, Li H, Chen Z, Xiao T. The efficacy of 3D printing-assisted surgery for traumatic fracture: a meta-analysis. Postgrad Med J. 2019. https:\/\/doi.org\/10.1136\/postgradmedj-2019-136482.","journal-title":"Postgrad Med J"},{"key":"1773_CR6","doi-asserted-by":"publisher","DOI":"10.5435\/JAAOSGlobal-D-20-00230","author":"CM Wixted","year":"2021","unstructured":"Wixted CM, Peterson JR, Kadakia RJ, Adams SB. Three-dimensional printing in orthopaedic surgery: current applications and future developments. J Am Acad Orthop Surg Glob Res Rev. 2021. https:\/\/doi.org\/10.5435\/JAAOSGlobal-D-20-00230.","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"key":"1773_CR7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcot.2018.07.022","author":"H Lal","year":"2018","unstructured":"Lal H, Patralekh MK. 3D printing and its applications in orthopaedic trauma: a technological marvel. J Clin Orthop Trauma. 2018. https:\/\/doi.org\/10.1016\/j.jcot.2018.07.022.","journal-title":"J Clin Orthop Trauma"},{"key":"1773_CR8","doi-asserted-by":"publisher","DOI":"10.1186\/s41205-016-0006-8","author":"N Bizzotto","year":"2016","unstructured":"Bizzotto N, Tami I, Santucci A, Adani R, Poggi P, Romani D, et al. 3D-printed replica of articular fractures for surgical planning and patient consent: a two years multi-centric experience. 3D Print Med. 2016. https:\/\/doi.org\/10.1186\/s41205-016-0006-8.","journal-title":"3D Print Med"},{"key":"1773_CR9","doi-asserted-by":"publisher","DOI":"10.1007\/s00113-019-0650-8","author":"S Weidert","year":"2019","unstructured":"Weidert S, Andress S, Suero E, Becker C, Hartel M, Behle M, et al. 3D-Druck in der unfallchirurgischen Fort- und Weiterbildung. Unfallchirurg. 2019. https:\/\/doi.org\/10.1007\/s00113-019-0650-8.","journal-title":"Unfallchirurg"},{"key":"1773_CR10","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1000097","author":"D Moher","year":"2009","unstructured":"Moher D, Liberati A, Tetzlaff J, Altman DG, Altman D, Antes G, et al. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009. https:\/\/doi.org\/10.1371\/journal.pmed.1000097.","journal-title":"PLoS Med"},{"key":"1773_CR11","doi-asserted-by":"publisher","DOI":"10.1186\/s13643-016-0384-4","author":"M Ouzzani","year":"2016","unstructured":"Ouzzani M, Hammady H, Fedorowicz Z, Elmagarmid A. Rayyan\u2014a web and mobile app for systematic reviews. Syst Rev. 2016. https:\/\/doi.org\/10.1186\/s13643-016-0384-4.","journal-title":"Syst Rev"},{"key":"1773_CR12","doi-asserted-by":"publisher","DOI":"10.1002\/9780470712184","author":"JP Higgins","year":"2008","unstructured":"Higgins JP, Green S. Cochrane handbook for systematic reviews of interventions. Cochrane Book Ser. 2008. https:\/\/doi.org\/10.1002\/9780470712184.","journal-title":"Cochrane Book Ser"},{"key":"1773_CR13","doi-asserted-by":"publisher","DOI":"10.1088\/1751-8113\/44\/8\/085201","author":"M Law","year":"1998","unstructured":"Law M, Stewart D, Pollock N, Letts L, Bosch J, Westmoreland M. Guidelines for critical review form\u2014quantitative studies. Quant Rev Form Guidel. 1998. https:\/\/doi.org\/10.1088\/1751-8113\/44\/8\/085201.","journal-title":"Quant Rev Form Guidel"},{"key":"1773_CR14","doi-asserted-by":"publisher","DOI":"10.1109\/ICCONS.2018.8662981","author":"N Jinsihan","year":"2018","unstructured":"Jinsihan N, Jin G. Recent developments of 3D-printing technique assisted surgery in the management of complex fractures. Int J Clin Exp Med. 2018. https:\/\/doi.org\/10.1109\/ICCONS.2018.8662981.","journal-title":"Int J Clin Exp Med"},{"key":"1773_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijsu.2018.07.012","author":"L Xie","year":"2018","unstructured":"Xie L, Chen C, Zhang Y, Zheng W, Chen H, Cai L. Three-dimensional printing assisted ORIF versus conventional ORIF for tibial plateau fractures: a systematic review and meta-analysis. Int J Surg. 2018. https:\/\/doi.org\/10.1016\/j.ijsu.2018.07.012.","journal-title":"Int J Surg"},{"key":"1773_CR16","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-019-1286-7","author":"N Beisemann","year":"2019","unstructured":"Beisemann N, Keil H, Swartman B, Schnetzke M, Franke J, Gr\u00fctzner PA, et al. Intraoperative 3D imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases. J Orthop Surg Res. 2019. https:\/\/doi.org\/10.1186\/s13018-019-1286-7.","journal-title":"J Orthop Surg Res"},{"key":"1773_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2010.04.007","author":"M Citak","year":"2011","unstructured":"Citak M, Citak M, Suero EM, O\u2019Loughlin PF, H\u00fcfner T, Krettek C. Navigated reconstruction of a tibial plateau compression fracture post-virtual reconstruction. A case report. Knee. 2011. https:\/\/doi.org\/10.1016\/j.knee.2010.04.007.","journal-title":"Knee"},{"key":"1773_CR18","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2020.02.011","author":"M Delcogliano","year":"2020","unstructured":"Delcogliano M, Marin R, Deabate L, Previtali D, Filardo G, Surace MF, et al. Arthroscopically assisted and three-dimensionally modeled minimally invasive rim plate osteosynthesis via modified anterolateral approach for posterolateral tibial plateau fractures. Knee. 2020. https:\/\/doi.org\/10.1016\/j.knee.2020.02.011.","journal-title":"Knee"},{"key":"1773_CR19","doi-asserted-by":"publisher","DOI":"10.1007\/s00113-016-0228-7","author":"J Franke","year":"2016","unstructured":"Franke J, Vetter SY, Beisemann N, Swartman B, Gr\u03cbtzner PA, Schnetzke M. 3-D-Sicherheit bei gelenknahen Osteosynthesen. Unfallchirurg. 2016. https:\/\/doi.org\/10.1007\/s00113-016-0228-7.","journal-title":"Unfallchirurg"},{"key":"1773_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2016.11.015","author":"S Giannetti","year":"2017","unstructured":"Giannetti S, Bizzotto N, Stancati A, Santucci A. Minimally invasive fixation in tibial plateau fractures using an pre-operative and intra-operative real size 3D printing. Injury. 2017. https:\/\/doi.org\/10.1016\/j.injury.2016.11.015.","journal-title":"Injury"},{"key":"1773_CR21","doi-asserted-by":"publisher","DOI":"10.4236\/ijcm.2019.103010","author":"C Guo","year":"2019","unstructured":"Guo C, Zhang Y, Yang L, Zhu Q, Zou S. The application and operation-effect analysis for complex tibial plateau fractures with 3D printing technique. Int J Clin Med. 2019. https:\/\/doi.org\/10.4236\/ijcm.2019.103010.","journal-title":"Int J Clin Med"},{"key":"1773_CR22","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000001708","author":"K Horas","year":"2020","unstructured":"Horas K, Hoffmann R, Faulenbach M, Heinz SM, Langheinrich A, Schweigkofler U. Advances in the preoperative planning of revision trauma surgery using 3D printing technology. J Orthop Trauma. 2020. https:\/\/doi.org\/10.1097\/BOT.0000000000001708.","journal-title":"J Orthop Trauma"},{"key":"1773_CR23","doi-asserted-by":"publisher","DOI":"10.1007\/s13246-015-0330-0","author":"H Huang","year":"2015","unstructured":"Huang H, Hsieh MF, Zhang G, Ouyang H, Zeng C, Yan B, et al. Improved accuracy of 3D-printed navigational template during complicated tibial plateau fracture surgery. Australas Phys Eng Sci Med. 2015. https:\/\/doi.org\/10.1007\/s13246-015-0330-0.","journal-title":"Australas Phys Eng Sci Med"},{"key":"1773_CR24","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-017-3445-y","author":"Y Lou","year":"2017","unstructured":"Lou Y, Cai L, Wang C, Tang Q, Pan T, Guo X, et al. Comparison of traditional surgery and surgery assisted by three dimensional printing technology in the treatment of tibial plateau fractures. Int Orthop. 2017. https:\/\/doi.org\/10.1007\/s00264-017-3445-y.","journal-title":"Int Orthop"},{"key":"1773_CR25","doi-asserted-by":"publisher","DOI":"10.1016\/j.cjtee.2019.07.006","author":"A Mishra","year":"2019","unstructured":"Mishra A, Verma T, Vaish A, Vaish R, Vaishya R, Maini L. Virtual preoperative planning and 3D printing are valuable for the management of complex orthopaedic trauma. Chin J Traumatol Engl Ed. 2019. https:\/\/doi.org\/10.1016\/j.cjtee.2019.07.006.","journal-title":"Chin J Traumatol Engl Ed"},{"key":"1773_CR26","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2018.12.019","author":"W Nie","year":"2019","unstructured":"Nie W, Gu F, Wang Z, Wu R, Yue Y, Shao A. Preliminary application of three-dimension printing technology in surgical management of bicondylar tibial plateau fractures. Injury. 2019. https:\/\/doi.org\/10.1016\/j.injury.2018.12.019.","journal-title":"Injury"},{"key":"1773_CR27","doi-asserted-by":"publisher","DOI":"10.1007\/s00068-020-01378-1","author":"AM Ozturk","year":"2020","unstructured":"Ozturk AM, Suer O, Derin O, Ozer MA, Govsa F, Aktuglu K. Surgical advantages of using 3D patient-specific models in high-energy tibial plateau fractures. Eur J Trauma Emerg Surg. 2020. https:\/\/doi.org\/10.1007\/s00068-020-01378-1.","journal-title":"Eur J Trauma Emerg Surg"},{"key":"1773_CR28","doi-asserted-by":"publisher","DOI":"10.3233\/THC-2011-0613","author":"Z Ruan","year":"2011","unstructured":"Ruan Z, Luo C, Feng D, Zhang C, Zeng B. Intraoperative three-dimensional imaging in tibial plateau fractures with complex depressions. Technol Heal Care. 2011. https:\/\/doi.org\/10.3233\/THC-2011-0613.","journal-title":"Technol Heal Care"},{"key":"1773_CR29","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-63219-w","author":"S Shen","year":"2020","unstructured":"Shen S, Wang PZ, Li XY, Han X, Tan HL. Pre-operative simulation using a three-dimensional printing model for surgical treatment of old and complex tibial plateau fractures. Sci Rep. 2020. https:\/\/doi.org\/10.1038\/s41598-020-63219-w.","journal-title":"Sci Rep"},{"key":"1773_CR30","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2009.10.053","author":"EM Suero","year":"2010","unstructured":"Suero EM, H\u00fcfner T, St\u00fcbig T, Krettek C, Citak M. Use of a virtual 3D software for planning of tibial plateau fracture reconstruction. Injury. 2010. https:\/\/doi.org\/10.1016\/j.injury.2009.10.053.","journal-title":"Injury"},{"key":"1773_CR31","doi-asserted-by":"publisher","DOI":"10.1055\/s-0037-1605563","author":"H Wang","year":"2018","unstructured":"Wang H, Newman S, Wang J, Wang Q, Wang Q. Corrective osteotomies for complex intra-articular tibial plateau malunions using three-dimensional virtual planning and novel patient-specific guides. J Knee Surg. 2018. https:\/\/doi.org\/10.1055\/s-0037-1605563.","journal-title":"J Knee Surg"},{"key":"1773_CR32","doi-asserted-by":"publisher","DOI":"10.1111\/os.12466","author":"W Wu","year":"2019","unstructured":"Wu W, yong, Xu W guo, Wan C you, Fang M, . Preoperative plan with 3D printing in internal and external fixation for complex tibial plateau fractures. Orthop Surg. 2019. https:\/\/doi.org\/10.1111\/os.12466.","journal-title":"Orthop Surg"},{"key":"1773_CR33","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2016.09.025","author":"P Yang","year":"2016","unstructured":"Yang P, Du D, Zhou Z, Lu N, Fu Q, Ma J, et al. 3D printing-assisted osteotomy treatment for the malunion of lateral tibial plateau fracture. Injury. 2016. https:\/\/doi.org\/10.1016\/j.injury.2016.09.025.","journal-title":"Injury"},{"key":"1773_CR34","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/231820","author":"H Zhang","year":"2015","unstructured":"Zhang H, Li Z, Xu Q, Zhang Y, Xu K, Ma X. Analysis for clinical effect of virtual windowing and poking reduction treatment for Schatzker III tibial plateau fracture based on 3D CT data. Biomed Res Int. 2015. https:\/\/doi.org\/10.1155\/2015\/231820.","journal-title":"Biomed Res Int"},{"key":"1773_CR35","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198911000-00004","author":"JN Insall","year":"1989","unstructured":"Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of The Knee Society clinical rating system. Clin Orthop Relat Res. 1989. https:\/\/doi.org\/10.1097\/00003086-198911000-00004.","journal-title":"Clin Orthop Relat Res"},{"key":"1773_CR36","doi-asserted-by":"publisher","unstructured":"Spek RWA, Schoolmeesters BJA, Oosterhoff JHF, Doornberg JN, van den Bekerom MPJ, Jaarsma RL, Eygendaal D, IJpma F; Traumaplatform 3D Consortium. 3D-printed handheld models do not improve recognition of specific characteristics and patterns of three-part and four-part proximal humerus fractures. Clin Orthop Relat Res. 2021. https:\/\/doi.org\/10.1097\/CORR.0000000000001921. Online ahead of print. PMID: 34427569","DOI":"10.1097\/CORR.0000000000001921"},{"key":"1773_CR37","doi-asserted-by":"publisher","DOI":"10.1097\/CM9.0000000000000649","author":"JH Huang","year":"2020","unstructured":"Huang JH, Liao H, Tan XY, Xing WR, Zhou Q, Zheng YS, et al. Surgical treatment for both-column acetabular fractures using pre-operative virtual simulation and three-dimensional printing techniques. Chin Med J (Engl). 2020. https:\/\/doi.org\/10.1097\/CM9.0000000000000649.","journal-title":"Chin Med J (Engl)"},{"key":"1773_CR38","doi-asserted-by":"publisher","DOI":"10.1186\/s12938-016-0236-4","author":"P Tack","year":"2016","unstructured":"Tack P, Victor J, Gemmel P, Annemans L. 3D-printing techniques in a medical setting: a systematic literature review. Biomed Eng Online. 2016. https:\/\/doi.org\/10.1186\/s12938-016-0236-4.","journal-title":"Biomed Eng Online"},{"key":"1773_CR39","doi-asserted-by":"publisher","DOI":"10.1097\/brs.0000000000003747","author":"PAJ Pijpker","year":"2021","unstructured":"Pijpker PAJ, Kraeima J, Witjes MJH, Oterdoom DLM, Vergeer RA, Coppes MH, et al. Accuracy of patient-specific 3D-printed drill guides for pedicle and lateral mass screw insertion. Spine (Phila Pa 1976). 2021. https:\/\/doi.org\/10.1097\/brs.0000000000003747.","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-021-01773-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-021-01773-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-021-01773-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,13]],"date-time":"2022-06-13T18:19:17Z","timestamp":1655144357000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-021-01773-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,31]]},"references-count":39,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,6]]}},"alternative-id":["1773"],"URL":"https:\/\/doi.org\/10.1007\/s00068-021-01773-2","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,31]]},"assertion":[{"value":"29 April 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 August 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 August 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Availability of data and material"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Code availability"}}]}}