{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T00:52:11Z","timestamp":1793407931292,"version":"4.5.0"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,9,6]],"date-time":"2021-09-06T00:00:00Z","timestamp":1630886400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,9,6]],"date-time":"2021-09-06T00:00:00Z","timestamp":1630886400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Trauma Emerg Surg"],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To compare the CFR-PEEK plates with conventional plates in fracture fixation with regards to clinical and radiological outcomes and complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A systematic literature search was conducted in four online databases independently by two reviewers using the Cochrane methodology for systematic reviews. The identified relevant studies were assessed against predetermined inclusion\/exclusion criteria. Independent data extraction and assessment of risk of bias and study quality was carried out.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Nine studies (patient\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009361) out of 6594 records were included for analysis: 2 RCTs (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200963), 3 prospective cohort studies (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009151), and 4 retrospective cohort studies (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009147). Studies were grouped per anatomic area of fixation. Four studies (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009200) examined fixation of proximal humerus fractures. Two studies (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200974) examined fixation of distal radius fractures. Two studies (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200953) assessed outcomes of fixation of distal femur fractures. One study (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200987) assessed the outcomes of fixation of ankle fractures. All nine studies reported very high union rates (from 91% in distal femur to 100% in upper limb) for the CFR-PEEK plate groups and low complication rates. There was no significant difference in clinical outcomes, and rate of complications as compared to the conventional plate groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>CFR-PEEK plates have high union rates in extremity fracture fixation similar to conventional plates with comparable good clinical outcomes and a very low and comparable rate of complications. Considering their advantages, CFR-PEEK plates seem to be valid alternative to conventional plating.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00068-021-01778-x","type":"journal-article","created":{"date-parts":[[2021,9,6]],"date-time":"2021-09-06T03:04:07Z","timestamp":1630897447000},"page":"2387-2406","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Fracture fixation in extremity trauma with carbon fiber-reinforced polyetheretherketone (CFR-PEEK) plates: evidence today"],"prefix":"10.1007","volume":"48","author":[{"given":"George D.","family":"Chloros","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Apostolos D.","family":"Prodromidis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jo","family":"Wilson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5205-7696","authenticated-orcid":false,"given":"Peter V.","family":"Giannoudis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,9,6]]},"reference":[{"issue":"1","key":"1778_CR1","doi-asserted-by":"publisher","first-page":"52","DOI":"10.13005\/msri\/140109","volume":"14","author":"P Bhatt","year":"2017","unstructured":"Bhatt P, Goe A. Carbon fibres: production, properties and potential use. Mater Sci Res India. 2017;14(1):52\u20137.","journal-title":"Mater Sci Res India"},{"issue":"1","key":"1778_CR2","first-page":"23","volume":"4","author":"R Hillock","year":"2014","unstructured":"Hillock R, Howard S. Utility of carbon fiber implants in orthopedic surgery: literature review. Reconstr Rev. 2014;4(1):23\u201332.","journal-title":"Reconstr Rev."},{"key":"1778_CR3","doi-asserted-by":"publisher","first-page":"33","DOI":"10.4137\/CMAMD.S20354","volume":"8","author":"CS Li","year":"2015","unstructured":"Li CS, Vannabouathong C, Sprague S, Bhandari M. The use of carbon-fiber-reinforced (CFR) PEEK material in orthopedic implants: a systematic review. Clin Med Insights Arthritis Musculoskelet Disord. 2015;8:33\u201345.","journal-title":"Clin Med Insights Arthritis Musculoskelet Disord"},{"issue":"1","key":"1778_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s12306-015-0371-2","volume":"99","author":"R Rotini","year":"2015","unstructured":"Rotini R, Cavaciocchi M, Fabbri D, Bettelli G, Catani F, Campochiaro G, et al. Proximal humeral fracture fixation: multicenter study with carbon fiber peek plate. Musculoskelet Surg. 2015;99(1):1\u20138.","journal-title":"Musculoskelet Surg"},{"issue":"12","key":"1778_CR5","doi-asserted-by":"publisher","first-page":"825","DOI":"10.3928\/01477447-20141124-05","volume":"37","author":"BGP Lindeque","year":"2014","unstructured":"Lindeque BGP, Hak DJ, Mauffrey C, Seligson D, Lindeque B. Use of carbon\u2013fiber-reinforced composite implants in orthopedic surgery. Orthopedics. 2014;37(12):825\u201330.","journal-title":"Orthopedics"},{"issue":"4","key":"1778_CR6","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s10195-014-0311-1","volume":"15","author":"L Tarallo","year":"2014","unstructured":"Tarallo L, Mugnai R, Adani R, Zambianchi F, Catani F. A new volar plate made of carbon\u2013fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases. J Orthop Traumatol. 2014;15(4):277\u201383.","journal-title":"J Orthop Traumatol"},{"issue":"3","key":"1778_CR7","doi-asserted-by":"publisher","first-page":"e2000041","DOI":"10.2106\/JBJS.CC.20.00041","volume":"10","author":"WA Goudriaan","year":"2020","unstructured":"Goudriaan WA, Tordoir RL, Broekhuis D, van der Wal RJP. Early failure of a carbon\u2013fiber-reinforced polyetheretherketone distal femur plate: a case report. JBJS Case Connect. 2020;10(3):e2000041.","journal-title":"JBJS Case Connect."},{"key":"1778_CR8","doi-asserted-by":"publisher","first-page":"S34","DOI":"10.1016\/S0020-1383(17)30655-1","volume":"48","author":"B Di Maggio","year":"2017","unstructured":"Di Maggio B, Sessa P, Mantelli P, Maniscalco P, Rivera F, Calori GM, et al. PEEK radiolucent plate for distal radius fractures: multicentre clinical results at 12 months follow up. Injury. 2017;48:S34\u20138.","journal-title":"Injury"},{"issue":"1","key":"1778_CR9","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1302\/0301-620X.64B1.7040407","volume":"64","author":"K Tayton","year":"1982","unstructured":"Tayton K, Johnson-Nurse C, McKibbin B, Bradley J, Hastings G. The use of semi-rigid carbon\u2013fibre-reinforced plastic plates for fixation of human fractures. Results of preliminary trials. J Bone Jt Surg Br. 1982;64(1):105\u201311.","journal-title":"J Bone Jt Surg Br."},{"issue":"12","key":"1778_CR10","doi-asserted-by":"publisher","first-page":"825","DOI":"10.3928\/01477447-20141124-05","volume":"37","author":"DJ Hak","year":"2014","unstructured":"Hak DJ, Mauffrey C, Seligson D, Lindeque B. Use of carbon\u2013fiber-reinforced composite implants in orthopedic surgery. Orthopedics. 2014;37(12):825\u201330.","journal-title":"Orthopedics"},{"key":"1778_CR11","unstructured":"Higgins JPTTJ, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (editors). Cochrane handbook for systematic reviews of interventions version 6.2 (updated February 2021). Cochrane: Cochrane; 2021. www.training.cochrane.org\/handbook."},{"key":"1778_CR12","doi-asserted-by":"publisher","first-page":"d5928","DOI":"10.1136\/bmj.d5928","volume":"343","author":"JP Higgins","year":"2011","unstructured":"Higgins JP, Altman DG, G\u00f8tzsche PC, J\u00fcni P, Moher D, Oxman AD, et al. The Cochrane Collaboration\u2019s tool for assessing risk of bias in randomised trials. BMJ. 2011;343:d5928.","journal-title":"BMJ"},{"key":"1778_CR13","unstructured":"Wells GASB, O\u2019Connell D, Peterson J, Welch V, Losos M, Tugwell P. The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses 2008: http:\/\/www.ohri.ca\/programs\/clinical_epidemiology\/oxford.asp."},{"issue":"9","key":"1778_CR14","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1046\/j.1445-2197.2003.02748.x","volume":"73","author":"K Slim","year":"2003","unstructured":"Slim K, Nini E, Forestier D, Kwiatkowski F, Panis Y, Chipponi J. Methodological index for non-randomized studies (minors): development and validation of a new instrument. ANZ J Surg. 2003;73(9):712\u20136.","journal-title":"ANZ J Surg"},{"issue":"7650","key":"1778_CR15","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1136\/bmj.39489.470347.AD","volume":"336","author":"GH Guyatt","year":"2008","unstructured":"Guyatt GH, Oxman AD, Vist GE, Kunz R, Falck-Ytter Y, Alonso-Coello P, et al. GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ. 2008;336(7650):924\u20136.","journal-title":"BMJ"},{"issue":"7","key":"1778_CR16","doi-asserted-by":"publisher","first-page":"e1000097","DOI":"10.1371\/journal.pmed.1000097","volume":"6","author":"D Moher","year":"2009","unstructured":"Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6(7):e1000097.","journal-title":"PLoS Med"},{"issue":"1","key":"1778_CR17","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1186\/s12874-017-0391-8","volume":"17","author":"T Mathes","year":"2017","unstructured":"Mathes T, Pieper D. Clarifying the distinction between case series and cohort studies in systematic reviews of comparative studies: potential impact on body of evidence and workload. BMC Med Res Methodol. 2017;17(1):107.","journal-title":"BMC Med Res Methodol"},{"key":"1778_CR18","doi-asserted-by":"publisher","first-page":"S24","DOI":"10.1016\/S0020-1383(17)30653-8","volume":"48","author":"D Perugia","year":"2017","unstructured":"Perugia D, Guzzini M, Mazza D, Iorio C, Civitenga C, Ferretti A. Comparison between carbon-peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures. Injury. 2017;48:S24\u20139.","journal-title":"Injury"},{"issue":"45","key":"1778_CR19","first-page":"757","volume":"116","author":"P Ziegler","year":"2019","unstructured":"Ziegler P, Maier S, Stockle U, Guhring M, Stuby FM. The treatment of proximal humerus fracture using internal fixation with fixed-angle plates. Dtsch Arztebl Int. 2019;116(45):757\u201363.","journal-title":"Dtsch Arztebl Int"},{"issue":"6","key":"1778_CR20","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1016\/j.injury.2017.03.035","volume":"48","author":"M Guzzini","year":"2017","unstructured":"Guzzini M, Lanzetti RM, Lupariello D, Morelli F, Princi G, Perugia D, et al. Comparison between carbon-peek plate and conventional stainless steal plate in ankle fractures. A prospective study of two years follow up. Injury. 2017;48(6):1249\u201352.","journal-title":"Injury"},{"issue":"1S","key":"1778_CR21","first-page":"61","volume":"90","author":"M Guzzini","year":"2018","unstructured":"Guzzini M, Lupariello D, Lanzetti RM, Mazza D, Ferretti A. Preliminary experience with triangular CarboFix \u201cPiccolo\u201d distal radius plate in wrist fractures. Clinical and radiological results. Acta Biomed. 2018;90(1S):61\u20136.","journal-title":"Acta Biomed"},{"issue":"3","key":"1778_CR22","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1007\/s00590-016-1891-7","volume":"27","author":"JC Katthagen","year":"2017","unstructured":"Katthagen JC, Ellwein A, Lutz O, Voigt C, Lill H. Outcomes of proximal humeral fracture fixation with locked CFR-PEEK plating. Eur J Orthop Surg Traumatol. 2017;27(3):351\u20138.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"6","key":"1778_CR23","doi-asserted-by":"publisher","first-page":"1103","DOI":"10.1007\/s00590-020-02681-8","volume":"30","author":"SE Byun","year":"2020","unstructured":"Byun SE, Vintimilla DR, Bedeir YH, Dean CS, Parry JA, Hak DJ, et al. Evaluation of callus formation in distal femur fractures after carbon fiber composite versus stainless steel plate fixation. Eur J Orthop Surg Traumatol. 2020;30(6):1103\u20137.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"8","key":"1778_CR24","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1097\/BOT.0000000000001223","volume":"32","author":"PM Mitchell","year":"2018","unstructured":"Mitchell PM, Lee AK, Collinge CA, Ziran BH, Hartley KG, Jahangir AA. Early comparative outcomes of carbon fiber-reinforced polymer plate in the fixation of distal femur fractures. J Orthop Trauma. 2018;32(8):386\u201390.","journal-title":"J Orthop Trauma"},{"issue":"Suppl 1","key":"1778_CR25","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1007\/s12306-018-0562-8","volume":"102","author":"A Padolino","year":"2018","unstructured":"Padolino A, Porcellini G, Guollo B, Fabbri E, Kiran Kumar GN, Paladini P, et al. Comparison of CFR-PEEK and conventional titanium locking plates for proximal humeral fractures: a retrospective controlled study of patient outcomes. Musculoskelet Surg. 2018;102(Suppl 1):49\u201356.","journal-title":"Musculoskelet Surg"},{"issue":"8","key":"1778_CR26","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1016\/j.jse.2014.12.028","volume":"24","author":"B Schliemann","year":"2015","unstructured":"Schliemann B, Hartensuer R, Koch T, Theisen C, Raschke MJ, Kosters C, et al. Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate. J Shoulder Elbow Surg. 2015;24(8):1282\u20138.","journal-title":"J Shoulder Elbow Surg"},{"issue":"6","key":"1778_CR27","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.2106\/00004623-197052060-00001","volume":"52","author":"CS Neer 2nd","year":"1970","unstructured":"Neer CS 2nd. Displaced proximal humeral fractures. I. Classification and evaluation. J Bone Jt Surg Am. 1970;52(6):1077\u201389.","journal-title":"J Bone Jt Surg Am."},{"issue":"3","key":"1778_CR28","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1054\/arth.2002.30291","volume":"17","author":"AK Al-Shawi","year":"2002","unstructured":"Al-Shawi AK, Smith SP, Anderson GH. The use of a carbon fiber plate for periprosthetic supracondylar femoral fractures. J Arthroplasty. 2002;17(3):320\u20134.","journal-title":"J Arthroplasty"},{"key":"1778_CR29","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s13037-019-0210-8","volume":"13","author":"F Allemann","year":"2019","unstructured":"Allemann F, Halvachizadeh S, Rauer T, Pape HC. Clinical outcomes after carbon-plate osteosynthesis in patients with distal radius fractures. Patient Saf Surg. 2019;13:30.","journal-title":"Patient Saf Surg"},{"issue":"6","key":"1778_CR30","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1016\/j.injury.2003.10.014","volume":"35","author":"D Baker","year":"2004","unstructured":"Baker D, Kadambande SS, Alderman PM. Carbon fibre plates in the treatment of femoral periprosthetic fractures. Injury. 2004;35(6):596\u20138.","journal-title":"Injury"},{"issue":"Suppl 6","key":"1778_CR31","doi-asserted-by":"publisher","first-page":"S36","DOI":"10.1016\/j.injury.2014.10.020","volume":"45","author":"M Caforio","year":"2014","unstructured":"Caforio M, Perugia D, Colombo M, Calori GM, Maniscalco P. Preliminary experience with Piccolo Composite, a radiolucent distal fibula plate, in ankle fractures. Injury. 2014;45(Suppl 6):S36\u20138.","journal-title":"Injury"},{"issue":"5","key":"1778_CR32","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/0020-1383(94)90244-5","volume":"25","author":"DJ Pemberton","year":"1994","unstructured":"Pemberton DJ, Evans PD, Grant A, McKibbin B. Fractures of the distal femur in the elderly treated with a carbon fibre supracondylar plate. Injury. 1994;25(5):317\u201321.","journal-title":"Injury"},{"issue":"3","key":"1778_CR33","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1177\/1938640017718343","volume":"11","author":"ZW Pinter","year":"2018","unstructured":"Pinter ZW, Smith KS, Hudson PW, Jones CW, Hadden R, Elattar O, et al. A retrospective case series of carbon fiber plate fixation of ankle fractures. Foot Ankle Spec. 2018;11(3):223\u20139.","journal-title":"Foot Ankle Spec"},{"issue":"7","key":"1778_CR34","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.1007\/s00590-020-02701-7","volume":"30","author":"L Tarallo","year":"2020","unstructured":"Tarallo L, Giorgini A, Novi M, Zambianchi F, Porcellini G, Catani F. Volar PEEK plate for distal radius fracture: analysis of adverse events. Eur J Orthop Surg Traumatol. 2020;30(7):1293\u20138.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"4","key":"1778_CR35","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1016\/j.injury.2010.11.058","volume":"42","author":"RC Sproul","year":"2011","unstructured":"Sproul RC, Iyengar JJ, Devcic Z, Feeley BT. A systematic review of locking plate fixation of proximal humerus fractures. Injury. 2011;42(4):408\u201313.","journal-title":"Injury"},{"issue":"6","key":"1778_CR36","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1016\/j.jse.2009.06.004","volume":"18","author":"C Thanasas","year":"2009","unstructured":"Thanasas C, Kontakis G, Angoules A, Limb D, Giannoudis P. Treatment of proximal humerus fractures with locking plates: a systematic review. J Shoulder Elbow Surg. 2009;18(6):837\u201344.","journal-title":"J Shoulder Elbow Surg"},{"issue":"10","key":"1778_CR37","doi-asserted-by":"publisher","first-page":"e401","DOI":"10.1097\/BOT.0000000000000333","volume":"29","author":"JB Lowe","year":"2015","unstructured":"Lowe JB, Monazzam S, Walton B, Nelson E, Wolinsky PR. How to use fluoroscopic imaging to prevent intraarticular screw perforation during locked plating of proximal humerus fractures: a cadaveric study. J Orthop Trauma. 2015;29(10):e401\u20137.","journal-title":"J Orthop Trauma"},{"issue":"6","key":"1778_CR38","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1016\/j.otsr.2018.05.002","volume":"104","author":"R Mugnai","year":"2018","unstructured":"Mugnai R, Tarallo L, Capra F, Catani F. Biomechanical comparison between stainless steel, titanium and carbon\u2013fiber reinforced polyetheretherketone volar locking plates for distal radius fractures. Orthop Traumatol Surg Res. 2018;104(6):877\u201382.","journal-title":"Orthop Traumatol Surg Res"},{"issue":"3","key":"1778_CR39","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.arthro.2007.10.006","volume":"24","author":"GD Chloros","year":"2008","unstructured":"Chloros GD, Wiesler ER, Poehling GG. Current concepts in wrist arthroscopy. Arthroscopy. 2008;24(3):343\u201354.","journal-title":"Arthroscopy"},{"issue":"2","key":"1778_CR40","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1097\/BOT.0b013e31829e6dd0","volume":"28","author":"WM Ricci","year":"2014","unstructured":"Ricci WM, Streubel PN, Morshed S, Collinge CA, Nork SE, Gardner MJ. Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases. J Orthop Trauma. 2014;28(2):83\u20139.","journal-title":"J Orthop Trauma"}],"container-title":["European Journal of Trauma and Emergency Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-021-01778-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00068-021-01778-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00068-021-01778-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,13]],"date-time":"2022-06-13T14:19:51Z","timestamp":1655129991000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00068-021-01778-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,6]]},"references-count":40,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,6]]}},"alternative-id":["1778"],"URL":"https:\/\/doi.org\/10.1007\/s00068-021-01778-x","relation":{},"ISSN":["1863-9933","1863-9941"],"issn-type":[{"value":"1863-9933","type":"print"},{"value":"1863-9941","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,6]]},"assertion":[{"value":"29 June 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 August 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 September 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"No conflicts of interest to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}